Integration of Aberrometry and Topography with the i Trace System

Slides:



Advertisements
Similar presentations
Evaluation of Higher Order Aberrations in Eyes with Dohlman/Boston Keratoprosthesis and Comparison with Penetrating Keratoplasty and Normal Eyes K.Stasi.
Advertisements

Aberrometry and the Tear Film — Understanding new methods —
MYOPIA, ASTIGMATISM, HYPEROPIA… PERSONALIZED TREATMENT Bernard Mathys, MD Secretary-general of the Belgian Society of Cataract & Refractive Surgery.
VisTor The new Toric IOL by Hanita Lenses
Refractive Surgery Challenges and their most modern approach D. Alexopoulos MD,DO
RAY TRACING & WAVEFRONT ANALYSIS USING THE TRACEY SYSTEM Donald R. Sanders, M.D., Ph.D. Center For Clinical Research.
IN THE NAME OF GOD.
Dr H. Razmjoo Isfahan University of Medical Sciences Multifocal IOLs
Introduction to Refractive Error and Prescription Writing Walter Huang, OD Yuanpei University Department of Optometry.
Quality Control in Refractive Surgery
Optical Aberrations and Aberrometry F. Karimian, MD 2002
Intracorneal Inlays for Presbyopia Moderator Ioannis Pallikaris Instructors Stephen Slade John Vukich Dimitrios Bouzoukis Insructional Course 59 19/9/2011.
LIGHT AND THE RETINAL IMAGE: KEY POINTS Light travels in (more or less) straight lines: the pinhole camera’s inverted image Enlarging the pinhole leads.
Wavefront-Guided Laser Surgery. 2 How the eye works Light rays enter the eye through the clear cornea, pupil and lens. These light rays are focused directly.
Thin Lens Equation Distances of virtual images are negative & distances of real images are positive. Heights are positive if upright (above P.A.) and negative.
Optical Instruments Chapter 25.
Comparison of Early Outcomes of Topo-Guided PRK With Two Refractive Lasers WCC 2015 San Diego, California Simon P. Holland MB. FRCSC,FRCS,MRCP 1, 2, A,
Aspheric IOL’s: clinical benefits and customizing cataract surgery Bojan Pajic, MD, PhD, FEBO Swiss Eye Research Foundation, ORASIS, Reinach, Switzerland.
By Kelsey Matthews. History  LASIK stands for laser in situ keratomileusis  Developed in 1991 by a greek doctor Ioannis Pallikaris  Purpose to correct.
Walter Huang, OD Yuanpei University Department of Optometry
Laser Vision Correction for Myopia, Myopic Astigmatism, Hyperopia and Hyperopic Astigmatism with CustomVis Solid State Laser (213nm) THE ROYAL AUSTRALIAN.
Hyperopia Walter Huang, OD Yuanpei University Department of Optometry.
Mitchell A Jackson MD Founder/Director, Jacksoneye Lake Villa, IL USA
Alex P. Lange The author has no financial interest to disclose.
Refractive Errors & methods of correction M. F. Al Fayez, MD, FRCS.
26/11/04 BSCRS Aberrometry in daily practice Bernard Mathys, MD.
Repeatability of Anterior and Posterior Corneal Higher- Order Aberrations in 4 mm, 6 mm and 8 mm diameters measured by Pentacam System Jadwiga Wojtowicz.
Wavefront Sensing of the Human Eye
Optical Instruments, Camera A single lens camera consists basically of an opaque box, converging lens and film. Focusing depends on the object distance.
Fundamental of Optical Engineering Lecture 3.  Aberration happens when the rays do not converge to a point where it should be. We may distinguish the.
Wavefront by Method of Ray Tracing: Because the Eye is Not a Telescope
A diffraction grating with 10,000 lines/cm will exhibit the first order maximum for light of wavelength 510 nm at what angle? (1 nm = 10-9 m) 0.51° 0.62°
Accommodative Arching Eyeonics Briefing 2 February 2005 Kevin L. Waltz, OD, MD Eye Surgeons of Indiana Indianapolis, IN.
For Accommodative Lenses Deepak Chitkara, M.B., ChB. D.O.
Professor Ioannis Pallikaris MD, PhD.  Different mediums (Nd:YAG Crystals vs ArF Gas)  Less optics for the shaping of the pulse  No use of toxic gasses.
Characterization of Higher Order Ocular Aberrations (HOA) In ‘Normal’ Versus Myopic Eyes To Study The Effect Of Myopia On Higher Order Aberrations Amit.
A Fellow Eye Comparison of Aberrations, Modulation Transfer Function and Contrast Sensitivity After AcrySof IQ and AcrySof Natural IOL Implantation. Mayank.
ASCRS 08 Changes Of Higher Order Aberrations After Excimer Laser Treatment For Moderate Myopia by Means of Preoperative Wavefront Aberration Levels using.
A New Definition of Refraction: Basics and Beyond Austin Roorda, Ph.D. Unversity of Houston College of Optometry.
Elias F. Jarade, MD, FICS. Corneal and Refractive Surgery Service, The Dubai Mall Medical Center, Dubai- U.A.E. Tel: ; Mob
Corneal Topography using Orbscan : Basics and interpretation
March 2011 Bascom Palmer Eye Institute University of Miami Elaine Wu, M.D. Ana Paula Canto, M.D. William Culbertson, M.D. Sonia Yoo, M.D. Financial disclosure:
Tracey Technologies AAO 2004 Advisors Group Breakfast Tom Padrick, PhD Director of Engineering.
Evaluation of refractive error measurements obtained by three different aberrometers Radha Ram, BA Li Wang, MD, PhD Mitchell P. Weikert, MD, MS Disclosure:
Evaluation Of The Tetraflex and Crystalens Accommodative IOLs Using the iTrace Aberrometer Donald R. Sanders, M.D., PhD. David C. Brown M.D. Deepak Chitkara,
LADARVision4000 Vs VISX CustomVue LADARVision4000 Vs VISX CustomVue CustomCornea CustomCornea A Comparison of Wavefront Guided Refractive Surgery outcomes.
Refractive Accuracy of LASIK Using the IntraLase and Zyoptix BACKGROUND Wavefront guided customized lasik procedures are designed to correct both lower.
Unwrapping Hartman-Shack Images from Highly Aberrated Eyes Using an Iterative B-spline Based Extrapolation Method Linda Lundstrom & Peter Unsbo Royal Institute.
Analysis of Ocular Wavefront Aberrations in Post Penetrating Keratoplasty Eyes with Two Different Hartmann-Shack Aberrometers Adriana S. Forseto 1, MD;
Correlation of Len Aberrations with Incipient Cataracts Using the Tracey iTrace Visual Function Analyzer by Dr. Paulo Pedri Brazil.
Ocular functional optical zone following hyperopic LASIK/PRK: Analysis based on polychromatic retinal image quality Mitchell P. Weikert, MD Li Wang, MD,
Financial Disclosure: Medical Director–Galilei R&D Consultant, Ziemer Group AG, Port, Switzerland Consultant & Territory Manager for.
Variations in refractive analysis with different diffractive multifocal intraocular lenses using different wavefront analyzers Mami Yoshino, Hiroko Bissen-Miyajima,
iTrace Dynamic Laser Refraction: Clinical Application
Types of refraction Clinical classification of myopia.
Management of Astigmatism - An overview
Warren Hill, MD, FACS East Valley Ophthalmology 5620 E. Broadway Road
Omni-Focal Treatment for Correction of Presbyopia in Hyperopes: 1 Year Results Efekan Coskunseven, Baha Toygar, Serife Atun, Haluk Talu, Ebru Arslan Dunya.
Examples of Accommodation Evaluation with the Tracey 3-D Difference Maps Tracey Technologies, Corp.
CATz for Highly Irregular Corneas after Keratorefractive Surgery Hamed M. Anwar, MD, FRCS Alaa El-Danasoury, MD, FRCS 1 Institutional affiliation: Magrabi.
Optical Instruments II Instruments for Imaging the Retina.
July © Chuck DiMarzio, Northeastern University ECEG105/ECEU646 Optics for Engineers Course Notes Part 4: Apertures, Aberrations Prof.
Measurements of Multifocal Intraocular Lenses Using a Fluid-Filled Model Eye Charles Campbell This presentation is the result of work done with the assistance.
Asociación Para Evitar La Ceguera En México
Comparison of vision with an accommodating IOL versus a multifocal IOL
Pharmacological Correction of Presbyopia: A preliminary Study
Conventional LASIK V/S Zyoptix LASIK
Examination Techniques for Accuracy and Efficiency
Mohamed Abdelrahman Awadalla,FRCS Magrabi Eye Hospital Cairo - Egypt
*Center for Excellence in Eyecare
Presentation transcript:

Integration of Aberrometry and Topography with the i Trace System July 2005 Joe S. Wakil, MD - Tracey Technologies, LLC EyeSys Vision, Inc.

Founding Technology Developers: Vasyl Molebny, DSc Kiev, Ukraine Ioannis Pallikaris, MD Crete, Greece Canadian & Swedish Governments

Why Aberroscopy? Current Laser Technology Permits One to Go Beyond Correction of Sphere and Astigmatism You Can Now Address Your Patient’s Quality of Vision High Order Aberrations Define Quality of Vision

Why Ray Tracing? Because… the Eye is NOT a Telescope! Pupil Size: Accommodation: Tear Film: Effects Refraction (ex. Night Myopia) Refraction is NOT a FIXED Number! Effects Refraction (Instrument Myopia) Effects Quality of Vision (Aberrations) Where are the Sources of Aberrations? How do they change with Surgery? Cornea: Lens: Astigmatism (Irreg.), Sph & other HOA Astigmatism, Coma & other HOA

The Eye is NOT a Telescope Off-Axis design No magnification Variable aperture Variable detector res. Accommodation Changing fixation Brain image processing Nature-made TELESCOPE On-Axis design High magnification Fixed aperture Constant detector res. No accommodation Fixed alignment Digital image processing Man-made

Significant Higher Order Aberrations Trefoil Coma Spherical Aberration

Aberrometer/Wavefront Technologies Hartmann-Shack Lenslet Array Tscherning Aberrometer Differential Skiascopy Ray Tracing Features: -Rapid, point by point, IR measurement - no data confusion -Pupillometry with auto-tracking/capture -Programmable sampling (256 pts.) in any pupil up to 8mm -Open Field Fixation – avoid instrument myopia and measure Accommodation -Corneal Topography integration – able to measure Lens Aberrations

Hartmann Shack

Hartmann Shack

Hartmann-Shack Wavefront Sensor H/S Photo of patient with tight eye lid courtesy David Williams

Tscherning

Disadvantages of H-S and Tscherning Measures All Points at Once - Data Confusion, Compromised Resolution Limited Dynamic Range – Cannot Measure Highly Irregular Eyes Highly Sensitive to Noise – Slow, Requires Multiple Scans Expensive Components – High Cost to Purchase and Repair H-S Measures Reverse Aberrations – Not Physiologic with Real Vision especially for High Orders in Accomodation Tscherning Needs 2-D Imaging of Retina - Additional noise and errors

Differential Skiascopy

Disadvantages of Differential Skiascopy Does NOT Measure Skew Aberrations – Inaccurate WaveFront especially for Trefoil, Quadrafoil, etc. Measures Multiple Points at Once (slit) and only in Perpendicular Direction - Limited WF measurement (axial bias) No Open Field Fixation – Problem of instrument myopia in young patients

Total Ocular Aberrations Internal Optics Aberrations Corneal Aberrations Total Ocular Aberrations *Measuring Corneal Aberration without Lens or Total Aberration is of Questionable Value

The iTrace

Principles of Tracey Programmable thin beam ray tracing measuring forward aberrations of the eye Rapid sequential measurement of data points over entire entrance pupil (<50ms) Localization of each reflected retinal spot Integration of individual retinal spots to form Point Spread Function (PSF) Analysis of PSF for higher order aberrations and other data formats

Programmable Data Sample Points

Multiplying the Number of Sites

Higher Local Density of Sites

Overlay of Two Sets of Site Configuration

Refractive Error Measurements Myopia Hyperopia

Retinal Spot Diagram/Point Spread Function

Data Displays Retinal Spot Diagram Refraction Map Ablation Map X, µm 20 10 -10 -20 Y, µm 40 30 Refraction Map Retinal Spot Diagram Wavefront Map Ablation Map

Tracey’s Key Advantage: NO COMPROMISES! Rapid, point-by-point analysis of 256 data points avoids data confusion associated with simultaneous data measurements, therefore, all eyes (highly irregular) can be measured. All points in any pupil size (2-8mm) each with full dynamic range (+/- 15 D). NO COMPROMISES!

Baylor Clinical Study (100 eyes) by Doug Koch, MD

Validation Studies Three independent studies of Tracey vs. Manifest Refraction Koch et al - 100 eyes Slade et al - 42 eyes Schalhorn et al - 106 eyes Results Accuracy to manifest <0.12 D Reproducibility <0.12 D

The iTrace

Normal Eye

Irregular Eye

UCVA vs BCVA

Post LASIK

Full Corneal Topography

Full Corneal Topography

Keratoconus

Normal

iTrace Measures Accommodation Mechanism

Very Spherical Accommodation

Variations in Mapping Accommodative Power in the Natural Crystalline Lens as Measured by iTrace Horizontal Cyl Sphere Vertical Cyl Coma

Crystalens Accommodative Arching 73 Year Old Male Overall Refraction change is 0.5D but Central Cylinder 2.5 D adds Depth of Field to Enhance Accommodative Effect

MultiFocal IOL Analysis with i Trace PSF Analysis Modulation Transfer Function (MTF)obust Aberrometer Pupil Dependent Analysis Multi-Zone Refraction Analysis Retinal Spot Diagram Conoid of Sturm Dynamic Analysis Complete Corneal Topography Analysis Separates Corneal from Total Aberrations Resulting in Lenticular (internal ocular) Aberrations Measures Accommodation

Multifocal Acrylic IOL Alcon ReStor Lens

Monofocal Acrylic IOL Alcon SA-60

Normal Eye +0.5 D Hyperope

iTrace Summary Robust Aberrometer Measures Spatially Resolved Refraction and Aberrations for ALL eyes – including highly irregular Measurement Zone from 2.0 to 8.0 mm (Flexible) Multi-Zone Refraction Analysis Can do Over-Refraction with Contact Lenses or Spectacles Measures Psuedophakic eyes Complete Corneal Topography Analysis Separates Corneal from Total Aberrations Resulting in Lenticular (internal ocular) Aberrations Measures Accommodation Accurate Pupil Size Measurement

Thank you for your attention.