Introduction Magnetic resonance (MR) imaging is recognised as offering potential benefits in the delineation of target volumes for radiotherapy (RT). For.

Slides:



Advertisements
Similar presentations
Unwarping.
Advertisements

Assessment of tumoural ADC’s in rectal Tumours using Burst: New methodological Developments SJ Doran 1, ASK Dzik-Jurasz 2, J Wolber 2, C Domenig 1, MO.
In Chan Song, Ph.D. Seoul National University Hospital
Digital Image Processing
Introduction Radiostereometry (RSA) is well established research method for assessing movement of orthopaedic implants, bone fractures, and.
Spinal Posture Analysis technique using Diagnostic Imaging
Comparative Analysis of Continuous Table and Fixed table Acquisition Methods: Effects on Fat Suppression and Time Efficiency for Single-Shot T2-weighted.
Functional Brain Signal Processing: EEG & fMRI Lesson 12 Kaushik Majumdar Indian Statistical Institute Bangalore Center M.Tech.
Terry M. Button, Ph.D. Principals of Magnetic Resonance Image Formation.
Crystal Structural Behavior of CoCu₂O₃ at High Temperatures April Jeffries*, Ravhi Kumar, and Andrew Cornelius *Department of Physics, State University.
Introduction Radiosensitive polyacrylamide gels (PAG) provide a method of mapping dose distributions in 3D with sub-millimetre resolution [1]. Largely.
Realigning and Unwarping MfD
Introduction Three-dimensional gel dosimetry is a novel method for radiation measurement motivated by the need to verify experimentally the doses produced.
Lotte Verbunt Investigation of leaf positioning accuracy of two types of Siemens MLCs making use of an EPID.
EPI – Echo Planar Imaging Joakim Rydell
2D-CSI in a fraction of the time using multiple receiver coils Simon J. Doran 1, Adam J. Schwarz 2 and Martin O. Leach 2 1 Department of Physics, University.
McDaniels – Feb 29, Outline Patient 6 question Patient 11 ADC results Abstract for AAPM conference.
An algorithm for metal streaking artifact reduction in cone beam CT M. Bazalova 1,2, G. Landry 1, L. Beaulieu 3, F. Verhaegen 1,4 1-McGill University,
tomos = slice, graphein = to write
Magnetic Resonance Imaging Basic principles of MRI This lecture was taken from “Simply Physics” Click here to link to this site.
Introduction The effect of air-cavities within the human body, for example in the head and neck regions, present possible sources of error when calculating.
Trevor Thang Department of Medical Biophysics, Western University QUALITY ASSURANCE OF MRI FOR ADAPTIVE RADIOTHERAPY: PRELIMINARY INVESTIGATIONS Six Week.
Automated Image Analysis Software for Quality Assurance of a Radiotherapy CT Simulator Andrew J Reilly Imaging Physicist Oncology Physics Edinburgh Cancer.
M. D. A NDERSON Cancer Center Magnetic Resonance Imaging: 4.7 T, 40 cm Bruker Biospec James A Bankson, Ph.D. and John D Hazle, Ph.D. Small Animal Cancer.
Hg lamp Cylindrical lens, pinhole and filter  pseudo point-source Lens  parallel beam Scanning tank with matching medium Exposed gel Unexposed gel Diffuser.
MRI Guided Radiation Therapy: Brachytherapy
DIGITAL HIGH-RESOLUTION HEART PHANTOMS Abstract Background:X-ray based imaging modalities employ ionizing radiation with the potential for causing harmful.
Jason P. Stockmann 1 and R. Todd Constable 1,2 Yale University, Department of Biomedical Engineering 1, Department of Diagnostic Radiology 2, New Haven,
Software Development For Correction of Gradient- Nonlinearity Distortions in MR Images T.S. Lee, K.E. Schubert Computer Science CSUSB R.W. Schulte Radiation.
CTOS Soft Tissue Sarcoma of the Extremity Comparison of Conformal Post-operative Radiotherapy (CRT) and Intensity Modulated Radiotherapy (IMRT)
Healthcare research in the Physics Department Dr S J Doran Lecturer in Magnetic Resonance Imaging Department of Physics School of Electronics and Physical.
MRI SIMULATION FOR CONFORMAL RADIATION THERAPY OF PROSTATE CANCER Pasquier D 1-3, Palos G 3, Castelain B 1, Lartigau E 1,2, Rousseau J 2,3 1 Department.
BREAST MRI IN RADIATION THERAPY PLANNING MARSHA HALEY, M.D. ASSISTANT PROFESSOR UNIVERSITY OF PITTSBURGH CANCER INSTITUTE PITTSBURGH, PENNSYLVANIA, USA.
Introduction Since 1996 [1], it has been clear that optical computed tomography (CT) represents a viable alternative to MRI scanning of dosimeter gels.
Correcting for Center Frequency Variations in MRSI Data Using the Partially Suppressed Water Signal Lawrence P Panych, Ph.D., Joseph R Roebuck, Ph.D.,
CSci 6971: Image Registration Lecture 3: Images and Transformations March 1, 2005 Prof. Charlene Tsai.
Mitglied der Helmholtz-Gemeinschaft EPIK for TRIMAGE Seong Dae Yun 1 and N. Jon Shah 1,2 1 Institute of Neuroscience and Medicine 4 Forschungszentrum Jülich.
In Burst experiments, the read gradient is much larger then the other imaging gradients, hence, only translation along this gradient direction will cause.
MR Scanner Transmit Gain as an Indicator For Lead Heating November, 2006.
1 The induced field distribution in materials which inherently possess large internal magnetic fields, or in materials which get magnetized when placed.
Fig. 3 shows how a dose distribution that is initially relatively sharp becomes blurred with time, until after 16 hours, virtually no useful information.
A CCELERATED V ARIABLE F LIP A NGLE T 1 M APPING VIA V IEW S HARING OF P SEUDO -R ANDOM S AMPLED H IGHER O RDER K-S PACE J.Su 1, M.Saranathan 1, and B.K.Rutt.
Pelvic MR scans for radiotherapy planning: Correction of system- and patient-induced distortions Simon J Doran 1, Liz Moore 2, Martin O Leach 2 1 Department.
Results Fig. 4a shows the raw, noise-free, simulation data for a sample with T 1 = 1 s and T 2 = 100 ms. A clear difference is seen between the cases where.
Intravoxel Incoherent Motion Imaging in Locally Advanced Rectal Tumours Dr S J Doran Department of Physics University of Surrey S 1 Department of Physics,
The production of X-Rays X-Rays are produced whenever charged particles are slowed down or stopped. X-rays are generated via interactions of the accelerated.
Digital imaging By : Alanoud Al Saleh. History: It started in 1960 by the National Aeronautics and Space Administration (NASA). The technology of digital.
Conclusions Despite being able to acquire successfully high resolution images of radiation dose, image quality is limited by hardware problems. Upgrading.
Part No...., Module No....Lesson No
Conclusions Simulated fMRI phantoms with real motion and realistic susceptibility artifacts have been generated and tested using SPM2. Image distortion.
1 The induced field distribution in materials which inherently possess large internal magnetic fields, or in materials which get magnetized when placed.
MRI Physics: Spatial Encoding Anna Beaumont FRCR Part I Physics.
Real time shimming (RTS) for compensation of respiratory induced field changes P van Gelderen, JA de Zwart, P Starewicz, RS Hinks, JH Duyn Introduction.
A CCELERATED V ARIABLE F LIP A NGLE T 1 M APPING VIA V IEW S HARING OF P SEUDO -R ANDOM S AMPLED H IGHER O RDER K-S PACE J.Su 1, M.Saranathan 1, and B.K.Rutt.
Cone Beam CT at the Ghent University Hospital: first clinical results and evaluation of the selected workflow. G. Pittomvils 1,,M. Coghe 1, A. Impens 1,
Date of download: 7/8/2016 Copyright © ASME. All rights reserved. From: Measurement of the Dynamic Shear Modulus of Mouse Brain Tissue In Vivo by Magnetic.
References : [1] Hurkmans CW, et al Set-up verification using portal imaging; review of current clinical practice. Radiother. Oncol. 2001;58: [2]
A comparison between soft tissue and bone registration techniques for prostate radiotherapy Richard Small, Paul Bartley, Audrey Ogilvie, Nick West and.
IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.
CT Scan vs MRI.
Accuracy of RT Structure Set: An Inter-comparison of Four Treatment Planning Systems. Richa Sharma1, Kamlesh Passi2, PS Negi1, Sandhya Sood2, RK Grover1,
Excitation based cone-beam X-ray luminescence tomography of nanophosphors with different concentrations Peng Gao*, Huangsheng Pu*, Junyan Rong, Wenli Zhang,
Sunday Case of the Day Physics
CT-based surrogates of pulmonary ventilation in lung cancer:
Sunday Case of the Day Category Physics Question:
Parallel Imaging Artifacts in Body Magnetic Resonance Imaging
Sunday Case of the Day Physics (Case 1: MR)
Quantitative analysis
Volume 11, Issue 2, Pages (April 2016)
MRI basics for radiation oncologists
Presentation transcript:

Introduction Magnetic resonance (MR) imaging is recognised as offering potential benefits in the delineation of target volumes for radiotherapy (RT). For many soft tissue sites MR is able to provide significantly enhanced visualisation of the lesion, thereby improving target definition 1. A major concern regarding the use of MR for RT planning, however, is that the images are prone to both geometrical and intensity distortions. These distortions are a consequence both of system distortion (arising from main magnetic field inhomogeneity and non-linearities in the applied magnetic field gradients) and of effects arising from the patient being imaged, namely susceptibility and chemical shift variations. Gradient performance is known to vary with time and in particular can be altered during servicing 2. This abstract describes a method for removing both system and patient-induced distortions from MR scans to provide MR scans of the pelvis suitable for RT planning. Methods Quantification of System Distortion: A phantom system described previously 3 comprising an interlocking flat-topped couch insert, a reference frame and a linearity test object (LTO) is scanned using an acquisition sequence employing forward and reverse gradients. Susceptibility induced distortions arising from the test object itself can therefore be corrected using a simplified form of Chang and Fitzpatrick’s method 4. The phantom system then undergoes a computed tomography (CT) scan. Any differences between spot positions as visualised on MR images corrected for object induced distortion and those seen on an equivalently positioned CT image are associated with non-linearities of the gradients. The discrete set of measured distortions is fitted with a 2-D polynomial leading to an estimated distortion for every pixel in the image volume. Preliminary results indicate that gradient induced distortions may be as large as 20 mm towards the edge of the field of view. The reference frame and couch insert contain rows of water filled marker tubes which, when imaged, give a pattern of spots the locations of which uniquely define the position of the slice. Any significant change of these patterns between imaging the phantom and imaging the patient indicates a change in the factors contributing to MR distortion and therefore the previously determined gradient induced corrections cannot be employed. Results Results obtained using each stage of the method described above on a patient volunteer are depicted below. Maps, detailing the difference between Chang corrected images and the images acquired using forward and reverse gradients illustrate the contribution to distortion from magnetic field inhomogenities and chemical shift effects. The final difference map shows the degree of distortion arising from gradient non-linearities on a MR image previously corrected for object induced distortion. To demonstrate the impact of such non-linearities we show difference maps from two different parts of the body, the legs (situated a distance of about 15 cm from the isocentre) and the prostate (situated near the isocentre). Note that all images acquired using a reversed gradient have undergone an initial left-right reversal such that they can be subtracted from the Chang corrected image. S Pelvic MR scans for radiotherapy planning : correction of system and patient induced distortions L. Moore 1, S.J. Doran 2 and M.O. Leach 1 1 CRC Clinical Magnetic Resonance Research Group, Institute of Cancer Research, Sutton, SM2 5PT, UK 2 Department of Physics, University of Surrey, Guildford, GU2 7XH, UK forward read gradient (fwdgrad) reverse read gradient (revgrad) Chang corrected Chang - fwdgrad (difference map) Chang - revgrad (difference map) CT of LTO Chang image now corrected for gradient induced distortion* Effects of gradient of induced distortion (not that great near isocentre) (Difference map) forward read gradient (fwdgrad) reverse read gradient (revgrad) Chang corrected image Chang - fwdgrad largest differences at fat/air interface (Difference map) Chang - revgrad differences at interfaces in opposite directions forward read gradient (fwdgrad) CT of LTO +1 0 Distortion (mm) Phase encode Frequency Encode reverse read gradient (revgrad) Chang- corrected LTO gradient induced distortion (read) gradient induced distortion (phase) Chang image now corrected for gradient induced distortion* Effects of gradient of induced distortion - note large differences towards the edge of the FoV (Difference Map) Discussion and further work To date in vivo results obtained using our distortion correction system compare well with what is expected. The largest patient induced distortions are apparent at the fat/air interface and the largest gradient induced distortion appear towards the edge of the field of view. The accuracy of our system will be tested further by comparing fully corrected MR images with equivalent CT images; the patient having been reproducibly positioned in both examinations. The next version of the software will perform a full 3-D analysis, correcting for distortions in slice profiles. References 1. Khoo VS et al.[1997] Radiother. Oncology. 42 : Lemieux L, Barker G [1998] Med. Phys. 25 (6) : Finnigan DF [2000] ISMRM 2000 : Chang H, Fitzpatrick JM [1992] IEEE Trans. Med. Imaging. 11 : Acknowledgement The authors gratefully acknowledge the financial support of the Cancer Research Campaign Distortion (mm) Phase Direction Frequency Direction Phase Direction Frequency Direction Distortion (mm) +1 0 Distortion (mm) Phase direction Read Direction gradient induced distortion (read) 10 0 Distortion (mm) Phase Direction Read Direction gradient induced distortion (phase) Phase Direction 10 0 Phase Direction Read Direction Distortion (mm) * At present, we correct only inside the portion of the image spanned by the regular grid points of the LTO. forward read gradient (fwdgrad) Chang corrected LTO reverse read gradient (revgrad)