Figure 2 gives an overview of the hardware components of the upgraded Main Injector BPM system. The figure shows 2 signal channels which produce one position.

Slides:



Advertisements
Similar presentations
1 Proton Upgrades at Fermilab Robert Zwaska Fermilab March 12, 2007 Midwest Accelerator Physics Collaboration Meeting Indiana University Cyclotron Facility.
Advertisements

Managed by UT-Battelle for the Department of Energy Status and Implementation of Wideband Feedback System for e-p Instabilities in SNS Craig Deibele, Z.
Update of EXT Stripline BPM Electronics with LCLS-style Digital BPM Processors Glen White, with slides by Steve Smith 15 December 2009 ATF2.
Re-commissioning the Recycler Storage Ring at Fermilab Martin Murphy, Fermilab Presented August 10, 2012 at SLAC National Laboratory for the Workshop on.
Paul Derwent 30 Nov 00 1 The Fermilab Accelerator Complex o Series of presentations  Overview of FNAL Accelerator Complex  Antiprotons: Stochastic Cooling.
Tevatron BPM Upgrade Project Manager Overview Stephen Wolbers Tev BPM Technology Choice Review December 16, 2003.
F Tevatron Software Digital Receiver Beam Line Tuner Vic Scarpine Instrumentation Instrumentation Meeting July 13, 2005.
ATF2 Q-BPM System 19 Dec Fifth ATF2 Project Meeting J. May, D. McCormick, T. Smith (SLAC) S. Boogert (RH) B. Meller (Cornell) Y. Honda (KEK)
3/7/05A. Semenov Batch-by-Batch Intensity Monitor 1 Two-Channel Batch by Batch Intensity Monitor for Main Injector BBI.
1 NuMI BEAM POSITION MONITOR via MAIN INJECTOR, and RECYCLER Brajesh Choudhary, 06.Mar.2003 MINOS Collaboration Meeting University of South Carolina, Columbia.
DLS Digital Controller Tony Dobbing Head of Power Supplies Group.
Craig Drennan Linac and Booster Beam Diagnostics Proton Source Workshop December 7 and 8, 2010.
Proton Plans at Fermilab Robert Zwaska - Fermilab Science and Engineering at Henderson- DUSEL Capstone Workshop Stony Brook University May 5, 2006 Outline.
F MI High Power Operation and Future Plans Ioanis Kourbanis (presented by Bruce Brown) HB2008 August 25, 2008.
Antiproton Source Capabilities and Issues Keith Gollwitzer & Valeri Lebedev Accelerator Division Fermilab 1.
Digital Signal Processing and Generation for a DC Current Transformer for Particle Accelerators Silvia Zorzetti.
1 FermiLab Recycler Ring BPM Upgrade Based on Digital Receiver Technology R. Webber, J. Crisp, P. Prieto, D. Voy, C. Breigel, C. McClure, M. Mengel, S.
INTRODUCTION  RECYCLER BPM – Original system not adequate to measure beam position precisely. It is being upgraded to meet the required physics precision.
Tevatron BPM System Upgrade Technical Update Bob Webber Run II Luminosity Upgrade Review February 2004.
F Antiproton Source Apertures Steve Werkema DOE Tevatron Operations Review March 22, 2006.
Horz V1 H1 H2 V2 Pbars in Recycler Ring Stripline Kickers Split Plate Pickups A-B Vertical Digital Damper Vert Recycler Transverse Damper System Similar.
Recent RF Development at Fermilab Weiren Chou and Akira Takagi Fermilab, U.S.A. July 7, 2003 Presentation to the FFAG03 Workshop July 7-12, 2003, KEK.
Initial Performance Results of the APS P0 (Transverse Bunch-to-Bunch) Feedback System N. DiMonte#, C.-Y. Yao, Argonne National Laboratory, Argonne, IL.
January 19, 2006PEP TFB R.Akre PEP II Transverse Feedback System Ron Akre William Colocho Anatoly Krasnykh Vojtech Pacak Dmitry Teytelman Uli Wienands.
Current (recycler) timing/trigger system appears to be sufficient for TeV BPMs - add injection event to beam sync - TSG FPGAs nearly full, but dropping.
The Main Injector Beam Position Monitor Front-End Software Luciano Piccoli, Stephen Foulkes, Margaret Votava and Charles Briegel Fermi National Accelerator.
6 Oct 2003Vince Pavlicek1 Make a BPM out of a Damper?
An Investigation of Crosstalk on the Rapid Transfer BPM Analog Transition Module PC Board August 23, 2006 David Peterson Antiproton Source Department Fermi.
The ATF Damping Ring BPM Upgrade Nathan Eddy, Eliana Gianfelice-Wendt Fermilab for the ATF Damping Ring BPM Team.
BPM Upgrade Projects Status & Technical Update Bob Webber DOE Review of Tevatron Operations March 2005.
F Beam Line Tuners Vic Scarpine Instrumentation DoE Review Oct 28-31, 2002.
Fast feedback, studies and possible collaborations Alessandro Drago INFN-LNF ILCDR07 Damping Rings R&D Meeting 5-7 March 2007.
F Fermilab July 6, 2005Recycler Damper Stability1 Recycler Damper High Frequency Stability Jim Crisp
Accelerator Issues Fermilab Antiproton Experiment Keith Gollwitzer Antiproton Source Department Accelerator Division Fermilab.
Beam Line BPM Filter Module Nathan Eddy May 31, 2005.
Present Uses of the Fermilab Digital Signal Receiver VXI Module Brian Chase,Paul Joireman, Philip Varghese RF Embedded Systems (LLRF) Group.
BEPCII Transverse Feedback System Yue Junhui Beam Instrumentation Group IHEP , Beijing.
Tevatron BPM Upgrade Stephen Wolbers CD Accelerator Coordination Meeting August 3, 2004.
Status of the ATF Damping Ring BPM Upgrade Project Manfred Wendt for the ATF DR BPM collaboration.
18 December 2007 ATF Damping Ring BPM System Upgrade Joe Frisch, Justin May, Doug McCormick, Janice Nelson, Tonee Smith, Mark Woodley (SLAC) Charlie Briegel,
Fermilab February 17, 2003Recycler BPM Front-end1 Duane C. Voy
Tevatron BPM Upgrade Stephen Wolbers DOE Review February 25, 2004.
Tevatron BPM Upgrade Stephen Wolbers CD Accelerator Coordination Meeting September 21, 2004.
Updated Overview of Run II Upgrade Plan Beam Instrumentation Bob Webber Run II Luminosity Upgrade Review February 2004.
Simultaneous Position Measurements of Protons and Anti-Protons in the Tevatron R. K. Kutschke †, J. Steimel, R.Webber, S. Wolbers, Fermilab*, Batavia,
TeV BPM Review 12/16/2003 Summary Status, Motivation, and Directions.
 A model of beam line built with G4Beamline (scripting tool for GEANT4)  Simulated performance downstream of the AC Dipole for core of beam using  x.
Craig Drennan Linac and Booster Beam Diagnostics Proton Source Workshop December 7 and 8, 2010.
Specifications of Tevatron BPM Upgrade Jim Steimel.
Main Injector Beam Position Monitor Upgrade: Status and Plans Rob Kutschke All Experimenters’ Meeting April 3, 2006 Beams-doc-2217-v3.
Anatomy of Accelerators Marty Peters Summer 2006.
ATF DR BPM Upgrade Janice Nelson, Doug McCormick, Justin May, Andrei Seryi, Tonee Smith, Mark Woodley.
9/2/2003Tev BPM requirements1 Tevatron BPM and BLM requirements Mike Martens.
F Record luminosities at the Tevatron & Future potentiality Steve Werkema Fermi National Accelerator Laboratory Batavia, Illinois USA Asian Particle Accelerator.
F Possible Proton Capabilities at Fermilab Dave McGinnis April 16, 2007.
Robert R. Wilson Prize Talk John Peoples April APS Meeting: February 14,
Beam time structures 1 At any particular instance of time there will be only one kind of beam in the MI. It will be either protons or anti-protons. The.
12/16/03Tev BPM requirements1 Tevatron BPM requirements Mike Martens.
NuFACT06 Muon Source at Fermilab David Neuffer Fermilab.
The LHC Beam Position System Ad-hoc Working Group on LHC Experiment-Machine Parameter and Signal Exchange 26 th March 2002 Rhodri Jones (SL/BI)
Tevatron Beam Position Monitor Upgrade Stephen Wolbers (for the Tevatron BPM Upgrade Project) PAC05, Knoxville, TN May 16-20, 2005.
F Project X: Recycler 8.9 GeV/c Extraction D. Johnson, E. Prebys, M. Martens, J. Johnstone Fermilab Accelerator Advisory Committee August 8, 2007 D. Johnson.
Beam Diagnostics Seminar, Nov.05, 2009 Das Tune-Meßverfahren für das neue POSI am SIS-18 U. Rauch GSI - Strahldiagnose.
8/10/04N. Michelotti1 Study of Main Injector BLT.
Tevatron BPM Upgrade Project Review Summary Stephen Wolbers December 19, 2003 Tevatron Department Meeting.
A Survey of the Capabilities of the Upgraded TeV BPMs Rob Kutschke, CD/EXP Run II Meeting March 24, 2005 Beams-doc-1752-v2.
Bunch by bunch feedback systems for KEKB Makoto Tobiyama KEK Accelerator Laboratory.
Jorge Sánchez-Quesada BE-RF-FB
Beam Current Monitoring with ICT and BPM Electronics
Report on ATF2 Third Project Meeting ATF2 Magnet Movers ATF2 Q-BPM Electronics Is SLAC ILC Instrumentation Group a good name?
Presentation transcript:

Figure 2 gives an overview of the hardware components of the upgraded Main Injector BPM system. The figure shows 2 signal channels which produce one position channel. All 201 stripline BPM pickups and their tunnel cabling remain unchanged. Upgraded components are the Combiner Boxes, located in the accelerator tunnel and all read-out electronics hardware, concentrated in 7 locations around the ring. The analog electronics – several 8- channel so-called Transition Modules and a Controller Module - are located in a 6U high crate frame, supplied by an external, linear power supply. A core component of the BPM system is the commercial Echotek GC814 digital signal receiver. Several 8-channel modules, together with a processor module (Motorola MVME5500) and an in- house developed Timing & Fan-out Generator (TFG-II) are arranged in a VME crate. All the cabling within a rack and between crates is new. Analog Analog signal processing occurs in both the Combiner Boxes and the Transition Modules. The Combiner Boxes accept beam signals from the four stripline electrodes, pass them through a low-pass filter (fc ≈ 100 MHz) and combine them to form either a vertical measuring or a horizontal measuring signal pair. The analog Transition Modules interface the signals from the Combiner Boxes to the Echotek digital receiver, adapting signal levels and further filtering frequency content. Digital Eight-channel EchoTek ECDR-GC814-FV2 VME64X digital receiver boards are used for beam signal digitization and frequency conversion. Each GC814 channel is comprised of a 14 bit ADC (AD6645), a four-channel digital down DDC (GC- 4016), an FPGA accumulator, and 128K x 32 dual- ported RAM. These boards shift the information content of the beam signal from a RF analog form to a stream of digital, baseband I and Q data pairs. The position, P, and intensity, I, are given by: Fermilab Main Injector Beam Position Monitor Upgrade B. Banerjee, W. Barker, S. Bledsoe, T. Boes, C. Briegel, D. Capista, G. Deuerling, R. Dysert, R. Forster, S. Foulkes, W. Haynes, B. Hendricks, T. Kasza, R. Kutschke, A. Marchionni, M. Olson, V. Pavlicek, L. Piccoli, P. Prieto, S. Rapisarda, A. Saewert, J. Van Bogaert, M. Votava, R. Webber, M. Wendt, N. Wilcer, S. Wolbers Fermi National Accelerator Laboratory, P.O. Box 500, Batavia, IL, USA Introduction A project to upgrade the readout electronics of the Fermilab Main Injector (MI) Beam Position Monitors (BPMs) was begun in This project is one of many improvements to the Fermilab accelerator complex aimed at providing increased luminosity and reliability for the Run 2 collider physics program. The design builds upon many of the technologies and techniques used to upgrade the BPM electronics in the Fermilab Recycler Ring, the Fermilab Tevatron, as well as some of the transfer lines. Operational Requirements The Fermilab Main Injector (MI) is designed to accelerate either protons or antiprotons with an injection energy of 8 GeV and an extraction energy as high as 150 GeV. At any time, however, only one of the two beam species may be present. The time structure of the beam may be one of the following: This work was supported by Fermi National Accelerator Laboratory, operated by Universities Research Association Inc. under contract No. DE-AC02-76CH03000 with the United States Department of Energy Performance Figure 2: Overview of the Main Injector BPM hardware. The results presented below were obtained using a pre-production system installed for 11 BPM locations. Figure 3 illustrates, for one BPM, the closed-orbit capability at 53 MHz for a simple MI cycle. Figure 4 illustrates the closed-orbit response to a more complex MI cycle; both vertical and horizontal measurements are shown. Figure 5 summarizes the closed-orbit resolutions at 53 MHz obtained for the 11 BPMs, using the method described in Figure 3. Figure 5 illustrates the turn-by-turn capability of the system, using anti-protons injected from the Recycler. Figure 6: Turn-by-turn 2.5 MHz data for injection of anti-protons from the Recycler. Figure 3: Closed-orbit proton data, 53 MHz band. Figure 5: RMS resolution for different BPM locations. where the coefficients a i were determined bench test measurements. Figure 4: Closed orbit proton data, 53 MHz band. Anti-proton and NuMI neutrino production. For further details see the paper WPMP01046 contributed to this conference, and references therein. 53 MHz Protons: From 1 bunch up to a full batch of 84 bunches in successive 53 MHz buckets. Up to 6 batches, each one of 84 bunches, can be loaded in the MI. 53 MHz Anti-protons. Four consecutive groups of antiprotons, spaced by 396 ns, of typically 5 (up to 9) 53 MHz bunches, are present in the MI. 2.5 MHz - Protons or anti- protons. Four bunches in successive 2.5 MHz RF buckets (396 ns spacing). The supported measurement types are: Closed-orbit: A narrowband measurement averaging over all bunches for about 40 turns; resolution bandwidth 1 kHz. Turn-by-turn: A wideband measurement averaging over all bunches in 1/14 of the circumference (1/28 for 2.5 MHz); resolution bandwidth 500 kHz ( 250 kHz for 2.5 MHz ).