Brookhaven EBIS program: operation and development

Slides:



Advertisements
Similar presentations
Plasma Window Options and Opportunities for Inertial Fusion Applications Leslie Bromberg Ady Herskovitch* MIT Plasma Science and Fusion Center ARIES meeting.
Advertisements

What is the ISOLDE cooler RFQ CB - ISCOOL H. Frånberg.
Polarized 3He ++ ion source development for RHIC. Check the Bjorken Spin Sum Rule (the difference between the 1st moments of the proton and neutron spin.
Preinjector Group Collider-Accelerator Department
Technical studies for the HIE- ISOLDE Frontend upgrade Jacobo Montaño Marie Curie Fellow; CATHI Project * The research project has been supported by a.
05/20/ High-Current Polarized Source Developments Evgeni Tsentalovich MIT.
Simulations of Neutralized Drift Compression D. R. Welch, D. V. Rose Mission Research Corporation Albuquerque, NM S. S. Yu Lawrence Berkeley National.
E. Beebe LEBT & Ion Injection EBIS Project Technical Review 1/27/2005 LEBT and External Ion Injection Ed Beebe Preinjector Group Collider-Accelerator Department.
PST 2007 BNL 1 Development of High- performance Polarized e- source at Nagoya University. Nagoya University M.Yamamoto, S.Okumi, T.Konomi N.Yamamoto, A.Mano,
NON-EQUILIBRIUM HEAVY GASES PLASMA MHD-STABILIZATION IN AXISYMMETRIC MIRROR MAGNETIC TRAP A.V. Sidorov 2, P.A. Bagryansky 1, A.D. Beklemishev 1, I.V. Izotov.
Proposed injection of polarized He3+ ions into EBIS trap with slanted electrostatic mirror* A.Pikin, A. Zelenski, A. Kponou, J. Alessi, E. Beebe, K. Prelec,
HYBRIS: R. Keller Page 1 A Hybrid Ion Source Concept for a Proton Driver Front-End R. Keller, P. Luft, M. Regis, J. Wallig M. Monroy, A. Ratti, and.
September 12, 2013 PSTP 2013 G. Atoian a *, V. Klenov b, J. Ritter a, D. Steski a, A. Zelenski a, V. Zubets b a Brookhaven National Laboratory, Upton,
COULOMB ’05 Experiments with Cooled Beams at COSY A.Lehrach, H.J.Stein, J. Dietrich, H.Stockhorst, R.Maier, D.Prasuhn, V.Kamerdjiev, COSY, Juelich, I.Meshkov,
E. Beebe Test EBIS Results EBIS Project Technical Review 1/27/2005 An EBIS-based RHIC Preinjector - Test EBIS Results Ed Beebe Preinjector Group Collider-Accelerator.
Ion Source Update. We now have 2 running sources Source B has been running since the first part of June Both sources have been modified extensively since.
Design and Technical Challenges of the ILC Small Angle Interaction Regions October 19 th, 2006J. Borburgh, CERN, AB/BT Electrostatic separator limits With.
09/13/20111 Status of high intensity polarized electron gun project at MIT-Bates Evgeni Tsentalovich MIT.
FETS H - Ion Source Experiments and Installation Scott Lawrie, Dan Faircloth, Alan Letchford, Christoph Gabor, Phil Wise, Mark Whitehead, Trevor Wood,
October 4-5, Electron Lens Overall Design Alexander Pikin October 4, 2010 Electron Lens.
High Current Electron Source for Cooling Jefferson Lab Internal MEIC Accelerator Design Review January 17, 2014 Riad Suleiman.
Ion Heating and Cooling in an EBIT or EBIS Ross Marrs Lawrence Livermore National Laboratory LLNL-PRES HIE-EBIS Workshop CERN October 2012.
J. Alessi Overview EBIS Project Technical Review 1/27/05 An EBIS-based RHIC Preinjector - Overview Jim Alessi Preinjector Group Collider-Accelerator Department.
E. Pozdeyev1 Ion Back-Bombardment in RF Guns Eduard Pozdeyev BNL with contributions from D. Kayran, V. Litvinenko, I. Ben-Zvi.
REFERENCES [1] C.Y. Tan, FNAL Beams-doc-3646-v16, 2011 [2] V.N. Aseev, TRACK, the beam dynamics code, PAC05 [3] S. Kurennoy, LA-UR TRANSMISSION.
LBNL 88'' cyclotron operations Status of the 88-Inch Cyclotron High-Voltage upgrade project December 14, 2009 Ken Yoshiki Franzen.
1 Flux concentrator for SuperKEKB Kamitani Takuya IWLC October.20.
Calculation of the beam dynamics of RIKEN AVF Cyclotron E.E. Perepelkin JINR, Dubna 4 March 2008.
Operated by Los Alamos National Security, LLC for the U.S. Department of Energy’s NNSA U N C L A S S I F I E D Slide 1 Dynamic Electron Injection for Improved.
Jürgen Florenkowski GSI, Darmstadt Agenda Annual Report Meeting EU construction ( CNI ) contract "DIRAC-PHASE-1" for the FAIR project September 26, 2006.
J. Alessi Implementation Plan EBIS Project Technical Review 1/28/05 Implementation Plan WBS exists Working on a “bottoms up” cost estimate The following.
CLIC Project meting #16. June 2014 I. Syratchev High efficiency power sources I. Syratchev, CERN.
May 4, 2010 EBIS ARR Jim Alessi May 4- 7, 2010 Pre-commissioning and Commissioning.
EBIS ARR Jim Alessi May 4- 7, 2010 Technical Overview.
PHYSICAL PROJECT OF BOOSTER FOR NICA ACCELERATOR COMPLEX Alexey Tuzikov, Nikolay Agapov, Andrey Butenko, Alexey Eliseev, Viktor Karpinsky, Hamlet Khodzhibagiyan,
Polarized proton projections Wolfram Fischer 11 May 2012 RHIC Spin Collaboration Meeting BNL.
Polarized source upgrade. Source upgrade project Main component delivery: Atomic Beam Source- August 2011 Superconducting solenoid- March-2012.
Design Optimization of MEIC Ion Linac & Pre-Booster B. Mustapha, Z. Conway, B. Erdelyi and P. Ostroumov ANL & NIU MEIC Collaboration Meeting JLab, October.
X-ray absorption spectroscopy (XAS)
The Heavy Ion Fusion Virtual National Laboratory Neutralized Transport Experiment (NTX) P. K. Roy, S. S. Yu, S. Eylon, E. Henestroza, A. Anders, F. M.
High Intensity Polarized Electron Gun Studies at MIT-Bates 10/01/2008 PESP Evgeni Tsentalovich MIT.
Designing a Magnetron Injection Gun and magnetic field to confine the electron beam. Jayakrishnan A. Karakkad, Brian L.Beaudoin, Thomas M.Antonsen Jr.
September 19-20, 2007 E. Beebe EBIS & LEBT Tests Edward Beebe September 19-20, 2007 DOE Annual Review.
Polarized source upgrade RSC, January 11, OPPIS LINAC Booster AGS RHIC ( ) ∙10 11 p/bunch 0.6mA x 300us→11∙10 11 polarized H - /pulse. ( )
September 13, 2007 J. Alessi EBIS Project and EBIS as an ionizer for polarized He-3 ? Jim Alessi Work of E. Beebe, A. Pikin, A. Zelenski, A. Kponou, …
MeRHIC Internal Cost Review October, Dmitry Kayran for injector group MeRHIC Internal Cost Review October 7-8, 2009 MeRHIC: Injection System Gun.
Low-contamination Rare and Exotic Beams (at CARIBU) Sergey Kondrashev October 16, 2012.
Studies on 2.45 GHz microwave ion sources Abhishek Nag IISER, KOLKATA Presented By: G.O. Rodrigues IUAC, New Delhi Supervised By:
FEASIBILITY ANALYS OF AN MHD INDUCTIVE GENERATOR COUPLED WITH A THERMO - ACOUSTIC ENERGY CONVERSION SYSTEM S. Carcangiu 1, R. Forcinetti 1, A. Montisci.
RF System and EBIS of RAON
PS-ESS and LEBT State of the art Lorenzo Neri Istituto Nazionale di Fisica Nucleare Laboratori Nazionali del Sud.
PXIE absorber test bench A. Shemyakin, C. Baffes, K. Carlson, B. Hanna, L. Prost, J. Walton November 6, 2012 Project X meeting Test bench description Difficulties:
Two beam instabilities in low emittance rings Lotta Mether, G.Rumolo, G.Iadarola, H.Bartosik Low Emittance Rings Workshop INFN-LNF, Frascati September.
SPES Target Group Data…… INFN-CISAS-CNR collaboration The Ablation Ion Source for refractory metal ion beams A preliminary design.
REXEBIS In the Electron Beam Ion Source (EBIS) the 1+ ions are charge bred. The positive ions are trapped in an electron beam which knocks out electrons.
S.M. Polozov & Ko., NRNU MEPhI
Prospects for high-efficiency klystrons
Development of X-band 50MW klystron in BVERI
by P. Musumeci and F.Tazzioli
Adriana Rossi, Sergey Sadovich
How to run ions in the future?
High Compression and High Current Guns
Production of Magnetized Electron Beam from a DC High Voltage Photogun
R. Suleiman and M. Poelker October 12, 2018
November 14, 2008 The meeting on RIKEN AVF Cyclotron Upgrade Progress report on activity plan Sergey Vorozhtsov.
November 7, 2008 The meeting on RIKEN AVF Cyclotron Upgrade Progress report on activity plan Sergey Vorozhtsov.
Physics Design on Injector I
Status of the charge breeder upgrade
Multi-Ion Injector Linac Design – Progress Summary
Plans for future electron cooling needs PS BD/AC
Presentation transcript:

Brookhaven EBIS program: operation and development Alexander Pikin, James G. Alessi, Edward N. Beebe, Andrey Shornikov, Robert Mertzig, Fredrik Wenander and Richard Scrivens Brookhaven National Laboratory CERN BNL: Project funded by US Department of Energy and the National Aeronautics and Space Administration

Ion trap Electron collector Electron gun RHIC EBIS: overview 188cm RHIC EBIS parameters: Iel = (7 – 10) A Eel = (20 – 24) kV jel = (300 – 500) A/cm2 Ltrap = 1880 mm (increased from initial 1500mm, ΔB/B=20%) Btrap = 5 T Qtrap_max =220 nC (for 10A, 20 kV)

Optical system of RHIC EBIS RHIC EBIS magnetic and electrostatic structures are based on its prototype: Test EBIS. Separate magnetic control of ionization region, electron gun and electron collector regions. It provides good vacuum conductance from pumps to the central region in a conventional (“warm”) vacuum system and a good voltage hold-off for high-voltage leads. Immersed electron beam: the cathode of the gun is in a strong magnetic field (1.4 kGs), the electrons propagate along magnetic field lines, the magnetic flux is conserved within the beam cross-section.

Simulated trajectories Iel=10A, Pµ=2.6, Bcath=1.4 kGs Electron gun simulations Electrostatic model: Simulated trajectories Iel=10A, Pµ=2.6, Bcath=1.4 kGs Simulated emission current density distribution. Iel = 10 A.

Electron gun in its chamber Electron gun design Gun assembly Electron gun in its chamber IrCe cathode Cathode unit We replace cathodes once a year during maintenance works as a precaution

Maximum electron beam power to the collector: 300 kW (20Ax15 kV) Electron collector Maximum electron beam power to the collector: 300 kW (20Ax15 kV) Previous version of the electron collector Present version of the electron collector The purpose of modification was to eliminate the heating of the internal electrode inside the electron collector. Relatively small change of optics practically preserved the ion beam transmission and the effect on its emittance.

Ion optics 16-pole adaptor-deflector Structure of RHIC EBIS ion optics Electrostatic field distribution Inside 16-pole adaptor-deflector

Au32+ Iel = 15.0 A, Iion = 3.0 mA Entrance into RFQ Ion extraction simulations Au32+ Iel = 15.0 A, Iion = 3.0 mA Entrance into RFQ

The abundance of Au32+ drops from 18% to 12%. Ion charge state distribution The width of the ion charge state distribution depends on the degree of neutralization of the electron beam in the trap. For the neutralization higher than 25% it is broader than predicted by the model of successive ionization (SUK, CBSIM). The abundance of Au32+ drops from 18% to 12%.

Schematic of ion optics for external ion injection 3 external ion sources allow us to switch ion species in 0.2 seconds using electrostatic ion optics. The laser Ion source came in line this year and proved to be a versatile and reliable primary ion source. Schematic of ion optics for external ion injection

The main users are RHIC and NASA Research Laboratory (NSRL). RHIC EBIS commissioning After its commissioning in September of 2010 RHIC EBIS routinely supplies multicharged ions to RHIC accelerating facility. The main users are RHIC and NASA Research Laboratory (NSRL). While RHIC takes ion beams from EBIS only during its run, NSRL uses beams from EBIS most of the time.

He-3 2+ AGS He-4 1+, 2+ RHIC & NSRL C 5+ NSRL O 6+ NSRL Ne 5+ NSRL Ion beams from RHIC EBIS to users He-3   2+   AGS He-4   1+, 2+   RHIC & NSRL C 5+ NSRL O 6+ NSRL Ne   5+     NSRL Si 11+ NSRL Ar   11+         NRSL Ti   18+   NSRL Fe   20+   NSRL Cu   11+   RHIC Kr   18+         NSRL Xe   27+       NSRL Ta   38+   NSRL   Au   32+   RHIC  &  NSRL Pb 34+ AGS U   39+   RHIC Gas injection To date ions of 16 elements, 18 ion species have been delivered to accelerator for users 2.3E9 ions/pulse from EBIS

Two regimes of RHIC EBIS operation: Cu-Au run: beam intensity traces Two regimes of RHIC EBIS operation: For RHIC run EBIS produces 8 pulses with frequency 5 Hz in each supercycle (4-5 s)during the rings fill. Between fills RHIC EBIS either runs for NSRL (1 pulse per supercycle) or runs for itself with 1 pulse per supercycle, just to keep EBIS ready for fills. Au Cu

Vital EBIS data Total extracted ion charge from EBIS is typically > 100 nC/pulse (6.25E11 el. charges). Only the gun cathode requires regular replacement (once a year, just as a precaution). Liquid Helium refill in Superconducting solenoid is done every 25 days and takes approx. 1.5 hours. Small maintenance works (cryo-pump regeneration, flushing the Ti sublimation pumps) are usually done during RHIC stores and do not affect the RHIC schedule. The most frequent stops were due to the electron collector and RFQ power supplies trips. RHIC EBIS operation is fully automated. Even for runs with He - Au collisions, involving both He gas and Au ion injection and when substantial modification of vacuum system was necessary for each species, EBIS was running practically without operator interference. The availability of the ion beam from EBIS during the RHIC run was 99.8%.

Both BNL and CERN are interested in developing of EBIS Motivations of the electron gun development (Brillouin gun) Both BNL and CERN are interested in developing of EBIS with high-current density electron beam: Increase the ion charge state and therefore the ion energy after the BNL Booster for NSRL experiments. Reduce the confinement time and therefore the contamination of the ion beam. Reduce the power consumption and improve the vacuum conditions. Possible reduction of the ion beam emittance due to a smaller electron beam radius . Possibility of generating very high ion charge states for ISOLDE even for heavy elements.

The experiments with the new electron gun are done on BNL Test EBIS Test EBIS layout The experiments with the new electron gun are done on BNL Test EBIS Pulsed coil This is essentially the original structure of the Test EBIS with few new elements: A new Brillouin electron gun. A new ceramic break replaced a gate valve between the gun and the rest of Test EBIS to isolate the gun chamber from the ground. Degraded superconducting solenoid has B= 3.5 T instead of 4.6 T.

Electron gun design

Magnetic field distribution within the gun

Electron beam with optimum magnetic field Gun simulations Radial oscillations at fixed magnetic field and different electron current Electron beam with optimum magnetic field Iel=8.0A, Uan =41.8 kV, B=2.2 kGs

Experimental conditions: Experiments with electron beam transmission Experimental conditions: We used a HeatWave dispenser cathode with diameter 20 mm. Vacuum with hot cathode: Pgun_chamber=(2·10-8 – 1.4·10-7) Torr, Pgun-transition =(1·10-8 – 3·10-8)Torr Wehnelt electrode is internally connected to the cathode. Cathode heating current: (7.5 – 8.8) A (maximum of 72 watt). Magnetic field of the main solenoid is B=3.5 T The cathode of the gun is connected to the gun chamber: Ucath= Ugun_chamber=-10 kV

Trace of the electron beam current on a collector CT (0.5 A/div) Results of experiments with electron beam transmission Trace of the electron beam current on a collector CT (0.5 A/div) Iel=1.7 A, Uan=15.6 kV, Pbeam=0.87E-6A/V1.5 Maximum electron current transmitted to the electron collector is 1.7 A With higher electron current the beam loss on anode reaches 20 mA, which is a current limit for TREK 20/20. It seems such load is manageable and outgassing from the anode can be reduced by training. Which means that a power supply with higher acceptable load can be used for the anode. With sufficient heating power the perveance of the electron gun is Pexp =0.93E-6 A/V1.5 (simulated value Psim = 0.934E-6 A/V1.5)

Experiment with electron beam transmission (continue) Observations: Best electron beam transmission requires maximum available voltage on drift tubes inside the superconducting solenoid (DT4-DT9) (up to 20 kV): requires highest electron energy. Strong dependence of the beam transmission on the gun coil current with the best coil current close to the simulated optimum for a running electron beam current (1.3 kGs). Both potentials on the transition drift tubes (between the gun and SC the central drift tubes) and the current on a pulsed magnet coil in this transition region affect the electron beam transmission. Our preliminary attempts to detect RF generation by the electron beam so far did not show any excitation in a range of (10 – 100) MHz (axial oscillations of the electron beam in the gun-transition region).

Transmission cone: (for Iel=1 A) Possible interpretation of the results Our experimental results and observations give reason to believe, that the current load on the anode of the gun is caused primarily by reflecting of some primary electrons from the magnetic mirror at the entrance into the superconducting solenoid on their way to the trap: Transmission cone: (for Iel=1 A) The electrons with larger angles are reflected back. The most susceptible for reflection are the peripheral electrons with the largest angles.

Possible reasons of electron beam quality degradation in our case: Interpretation of results (continue) Possible reasons of electron beam quality degradation in our case: Axial movement of the gun parts due to thermal expansion (up to 1.5 mm). It can result in a not optimum position of the cathode with respect to the anode and magnetic shim, causing increase of radial oscillation. Cathode edge aberrational effect with relatively large radial gap between the cathode and the Wehnelt electrode (0.4 mm). Emission from the side of the cathode produces a beam component with large aberration and with current reaching several percents of the total beam: Wehnelt Simulation for the existing conditions: UCath = UWehnelt Cathode With existing magnetic and vacuum structures in Test EBIS the best way to increase current of the transmitted electron beam can be improving the electron beam quality – reducing the amplitude of radial oscillation.

Future plans with Brillouin gun Modify the electron gun: make the axial cathode position adjustable from outside to optimize the electron beam launch. Disconnect the Wehnelt electrode from the cathode and have it energized independently. Eliminate electron emission from the cathode periphery and increase the distance from the emission edge to the cathode-Wehnelt gap (make a sleeve on the cathode periphery). Energize a pulsed coil in the gun-transition area with higher current, to be able to control the phase of the reflected electrons coming back to the anode. Substantially Increase the injecting magnetic field on the gun (with accordingly higher electrostatic compression) to reduce the magnetic mirror.

Summary A Brillouin electron gun has been tested and electron beam up to 1.5 A has been transmitted to the electron collector. The anode load was the only beam loss component after EBIS tuning. Based on our experimental data we can suggest, that the reason of the anode load is reflection of primary electrons from the magnetic mirror, caused by a combination of poor beam quality and high magnetic mirror ratio (16 – 27). Modification of Test EBIS with a goal to increase the current of the transmitted electron beam according to our understanding of its physics is in progress. The test of isolated gun vacuum chamber was a success. This method of suppressing the magnetron discharge by eliminating the radial electric field will be implemented in RHIC EBIS. Experiments with ions from the residual gas started and confirmed a proper operation of the EBIS trap.