CALOR2000 Conference Annecy,France Oct 2000 1 Leslie Groer Columbia UniversityDØ Calorimeter Electronics Upgrade Columbia University New York DØ Calorimeter.

Slides:



Advertisements
Similar presentations
Sci-Fi tracker for IT replacement 1 Lausanne 9. December 2010.
Advertisements

ATLAS Tile Calorimeter Performance Henric Wilkens (CERN), on behalf of the ATLAS collaboration.
An SiPM Based Readout for the sPHENIX Calorimeters Eric J. Mannel IEEE NSS/MIC October 30, 2013.
Digital Filtering Performance in the ATLAS Level-1 Calorimeter Trigger David Hadley on behalf of the ATLAS Collaboration.
TileCal Electronics A Status Report J. Pilcher 17-Sept-1998.
Status of Eric Kajfasz CPPM/Fermilab GDR-Susy, Lyon - 26 novembre 2001.
February 2002, D0 meetingAuguste Besson1 Argon purity measurement of the calorimeter Argon Test Cell (A.T.C.) –measures the equivalent O 2 pollution with.
How to Build a Neutrino Oscillations Detector - Why MINOS is like it is! Alfons Weber March 2005.
FPCP 2002, 05/16-18/2002 p. 1 Richard E. Hughes, The Ohio State UniversityCDF Run II Status Status of CDF and Prospects Flavor Physics and CP Violation.
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
Ionization. Measuring Ions A beam of charged particles will ionize gas. –Particle energy E –Chamber area A An applied field will cause ions and electrons.
The Design of MINER  A Howard Budd University of Rochester August, 2004.
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
Mainz: Contributions to the LArg-Calorimeter Purity monitoring of the liquid argon and temperature measurement in the three cryostats - Old electronics.
Workshop on Quarkonium, November 8-10, 2002 at CERN Heriberto Castilla DØ at Run IIa as the new B-Physics/charmonium player Heriberto Castilla Cinvestav-IPN.
Measurement of Inclusive Jet cross section Miroslav Kop á l University of Oklahoma on behalf of the D Ø collaboration DIS 2004, Štrbské pleso, Slovakia.
EPS 2003, July 19, 2003David Buchholz, Northwestern University Performance of the D0 Experiment in Run II Detector Commissioning and Performance Accelerator,
Calor 2002, march 2002Auguste Besson1 Argon purity measurement of the D0 calorimeter Auguste Besson (ISN - Grenoble) for the D0 collaboration 10.
Calibration of the ZEUS calorimeter for electrons Alex Tapper Imperial College, London for the ZEUS Collaboration Workshop on Energy Calibration of the.
Simulation Calor 2002, March. 27, 2002M. Wielers, TRIUMF1 Performance of Jets and missing ET in ATLAS Monika Wielers TRIUMF, Vancouver on behalf.
Figure 1: ICD Single Channel Block Diagram Schematic PMT High Voltage Supply (see Figure 4 & 4a) LED Pulser PMT Calibration (see Figure 6) ICD Scintillator.
1 Online Calibration of Calorimeter Mrinmoy Bhattacharjee SUNY, Stony Brook Thanks to: D. Schamberger, L. Groer, U. Bassler, B. Olivier, M. Thioye Institutions:
ATLAS Liquid Argon Calorimeter Monitoring & Data Quality Jessica Levêque Centre de Physique des Particules de Marseille ATLAS Liquid Argon Calorimeter.
The CMS Electromagnetic Calorimeter Roger Rusack The University of Minnesota On behalf of the CMS ECAL collaboration.
A. Gibson, Toronto; Villa Olmo 2009; ATLAS LAr Commissioning October 5, 2009 Commissioning of the ATLAS Liquid Argon Calorimeter Adam Gibson University.
Installation and Commissioning of the ATLAS LAr Readout Electronics
DPF 2002, Colonial Williamsburg, VA May 25, Leslie Groer Columbia UniversityJet and Electron Identification in the Run 2 DØ Detector 1 Leslie Groer.
08-June-2006 / Mayda M. VelascoCALOR Chicago1 Initial Calibration for the CMS Hadronic Calorimeter Barrel Mayda M. Velasco Northwestern University.
The Electromagnetic Calorimeter – 2005 Operation J. Sowinski for the Collaboration and the Builders Indiana Univ. Michigan State Univ. ANL MIT BNL Penn.
D0 Status: 01/14-01/28 u Integrated luminosity s delivered luminosity –week of 01/ pb-1 –week of 01/ pb-1 –luminosity to tape: 40% s major.
Ursula Bassler, LPNHE Paris1Collaboration Meeting - 13 Sept Calorimeter: Status & Plans Preamp/ Driver Trig. sum Filter/ Shaper x1 x8 SCA (48 deep)
Results from particle beam tests of the ATLAS liquid argon endcap calorimeters Beam test setup Signal reconstruction Response to electrons  Electromagnetic.
All Experimenters MeetingDmitri Denisov Week of July 7 to July 15 Summary  Delivered luminosity and operating efficiency u Delivered: 1.4pb -1 u Recorded:
D0 PMG 6/15/00 PMG Agenda June 15, 2000  Overview (Tuts) u Detector status u Reportable milestones u Financial status u Summary  Response to DOE review.
Nirmalya Parua March 17, 2003 The RunII Calorimeter Nirmalya Parua (For the Calorimeter Group) Shifter’s Tutorial March 17, 2003  Overview Of the D0 Calorimeter.
Aurelio Juste (Fermilab) Rencontres de Moriond, March OUTLINE Tevatron Run 2 The upgraded DØ Detector Status Performance First Physics Results Outlook.
CALOR April Algorithms for the DØ Calorimeter Sophie Trincaz-Duvoid LPNHE – PARIS VI for the DØ collaboration  Calorimeter short description.
R.S. Orr 2009 TRIUMF Summer Institute
Levan BabukhadiaICHEP02 – 31 st International Conference on High Energy Physics, Amsterdam, 24 – 31 July, 2002 CHEP02 – 31 st International Conference.
April 5, 2003Gregory A. Davis1 Jet Cross Sections From DØ Run II American Physical Society Division of Particles and Fields Philadelphia, PA April 5, 2003.
Nirmalya Parua March 25-29, 2002 The RunII D0 Calorimeter Electronics Upgrade & Its Performance Nirmalya Parua State University of New York Stony Brook.
LHCf Detectors Sampling Calorimeter W 44 r.l, 1.6λ I Scintilator x 16 Layers Position Detector Scifi x 4 (Arm#1) Scilicon Tracker x 4(Arm#2) Detector size.
Susan Burke DØ/University of Arizona DPF 2006 Measurement of the top pair production cross section at DØ using dilepton and lepton + track events Susan.
2000 IEEE NSS Lyon,France Oct Hervé Lebbolo LPNHE ParisDØ Calorimeter Electronics Upgrade DØ Calorimeter Electronics Upgrade for Tevatron Run II.
Penny Kasper Fermilab Heavy Quarkonium Workshop 21 June Upsilon production DØ Penny Kasper Fermilab (DØ collaboration) 29 June 2006 Heavy Quarkonium.
Test Beam Results on the ATLAS Electromagnetic Calorimeters Lucia Di Ciaccio – LAPP Annecy (on behalf of the ATLAS LAr Group) OUTLINE Description of the.
DØ Beauty Physics in Run II Rick Jesik Imperial College BEACH 2002 V International Conference on Hyperons, Charm and Beauty Hadrons Vancouver, BC, June.
DØ Collaboration Workshop NIU, DeKalb, IL June Leslie Groer Columbia UniversityCalorimeter Electronics Upgrade Columbia University New York Calorimeter.
1 Experimental Particle Physics PHYS6011 Fergus Wilson, RAL 1.Introduction & Accelerators 2.Particle Interactions and Detectors (2) 3.Collider Experiments.
Robert R. Wilson Prize Talk John Peoples April APS Meeting: February 14,
Régis Lefèvre (LPC Clermont-Ferrand - France)ATLAS Physics Workshop - Lund - September 2001 In situ jet energy calibration General considerations The different.
LHC Symposium 2003 Fermilab 01/05/2003 Ph. Schwemling, LPNHE-Paris for the ATLAS collaboration Electromagnetic Calorimetry and Electron/Photon performance.
Run 2 Jets at the Tevatron Iain Bertram Lancaster University/DØ Experiment PIC2003  Inclusive Cross Section  Dijet Mass  Structure.
The ICD Project Alan L. Stone Louisiana Tech University All D0 Meeting - 7 September 2001.
A Brand new neutrino detector 「 SciBar 」 (2) Y. Takubo (Osaka) - Readout Electronics - Introduction Readout electronics Cosmic ray trigger modules Conclusion.
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
Krisztian PetersPrecision Calibration of the DØ HCAL in Run II1 Krisztian Peters University of Manchester For the DØ Calorimeter Algorithm Group June.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
PP December 7, 2004 The RunII Calorimeter Pierre Pétroff and Norm Buchanan (For the Calorimeter Group) (taken largely from N. Parua’s tutorial) Cal-Muo.
 13 Readout Electronics A First Look 28-Jan-2004.
Calorimeter Status Electronics Installation and Commissioning
The DØ Calorimeter Upgrade
DØ Upgrade Run II Introduction Physics Goals Tevatron Upgrade
A First Look J. Pilcher 12-Mar-2004
BESIII EMC electronics
Experimental Particle Physics PHYS6011 Putting it all together Lecture 4 6th May 2009 Fergus Wilson, RAL.
Experimental Particle Physics PHYS6011 Putting it all together Lecture 4 28th April 2008 Fergus Wilson. RAL.
- Calorimeter Calibration
Calorimeter Upgrade The Tevatron and Dzero Upgrades
Susan Burke, University of Arizona
Presentation transcript:

CALOR2000 Conference Annecy,France Oct Leslie Groer Columbia UniversityDØ Calorimeter Electronics Upgrade Columbia University New York DØ Calorimeter Electronics Upgrade for Tevatron Run II Leslie Groer October 11, 2000 CALOR2000 IX International Conference on Calorimetry in Particle Physics Annecy, France October 9-14, 2000

CALOR2000 Conference Annecy,France Oct Leslie Groer Columbia UniversityDØ Calorimeter Electronics Upgrade 2 Tevatron Run I ( )  Very successful Run I  p-pbar collisions at √s = 1.8 TeV   L dt ~ 120 pb -1 delivered to DØ and CDF  Peak luminosity ~ 1.6 x cm -2 s -1  Many exciting studies, including  Top discovery –M t =  5.2 (stat.)  4.9 (syst.) GeV/c 2 –  tt = 5.9  1.7 pb (DØ combined)  W mass measurement –M W = ± GeV (DØ combined)  Limits on anomolous gauge couplings  Limits on SUSY, LQ, compositeness, other exotica  Tests of QCD + Electroweak  b-quark physics  100+ published papers  60+ PhD theses

CALOR2000 Conference Annecy,France Oct Leslie Groer Columbia UniversityDØ Calorimeter Electronics Upgrade 3 Fermilab Accelerator Upgrade  Two new machines at FNAL for Run II:  Main Injector  150 GeV conventional proton accelerator  Supports luminosity upgrade for the collider, future 120 GeV fixed-target program, and neutrino production for NUMI  Recycler  8 GeV permanent magnet (monoenergetic) storage ring  permits antiproton recycling from the collider  Tevatron Status and Schedule  DØ and CDF roll in – January 2001  Run II start – March 2001  1.8 Tev  2 TeV  Goal:  L dt = 2 fb -1 by fb -1 + by 2006?  Very first p-pbar collisions seen (August 2000)

CALOR2000 Conference Annecy,France Oct Leslie Groer Columbia UniversityDØ Calorimeter Electronics Upgrade 4 Run II Parameters 0% 10% 20% 30% 40% ns 132 ns Run II Bunch Spacing # of Ints. / Crossing % Crossings

CALOR2000 Conference Annecy,France Oct Leslie Groer Columbia UniversityDØ Calorimeter Electronics Upgrade Run II DØ Upgrade New Solenoid, Tracking System SMT, SciFi, Preshowers Shielding Forward Mini-Drift Tubes Forward Scintillator (muon trigger) Central Scintillator (muon trigger) + New Electronics, Trig, DAQ Pseudorapidity  = —ln tan (  /2)

CALOR2000 Conference Annecy,France Oct Leslie Groer Columbia UniversityDØ Calorimeter Electronics Upgrade 6 Inner Detectors Forward Preshower Silicon Microstrip Tracker Fiber Tracker Solenoid Central Preshower 1.4 m Intercryostat Detector Superconducting solenoid (2T) 840k channel silicon vertex detector 77k channel scintillating fiber tracker Scintillating strip preshower in central and forward regions. (6k and 16k channels) Intercryostat detector (scintillator tiles)

CALOR2000 Conference Annecy,France Oct Leslie Groer Columbia UniversityDØ Calorimeter Electronics Upgrade 7 Preshower Detectors  Central mounted on solenoid (|  | < 1.2)  Forward on calorimeter endcaps (1.4 < |  | < 2.5)  Extruded triangular scintillator strips with embedded WLS fibers and Pb absorber  Trigger on low-p T EM showers  Reduce overall electron trigger rate by x3-5  VLPC and SVX II readout

CALOR2000 Conference Annecy,France Oct Leslie Groer Columbia UniversityDØ Calorimeter Electronics Upgrade 8 Intercryostat Detector (ICD) FPS ICD  Design  Scintillator based with phototube readout similar to Run I design. Re-use existing PMT’s (Hamamatsu R647).  16 supertile modules per cryostat with a total of 384 scintillator tiles  WLS fiber readout of scintillator tiles  Clear fiber light piping to region of low field ~40-50% signal loss over 5-6m fiber.  Readout/calibration scheme for electronics same as for L. Ar. Calorimeter but with adapted electronics and pulser shapes  LED pulsers used for PMT calibration  Relative yields measured > 20 p.e./m.i.p.  Objectives  Maintain performance in presence of a magnetic field and additional material from solenoid  Improve coverage for the region 1.1 < |  | < 1.4  Improves jet E T and E T / LaTech UT, Arlington

CALOR2000 Conference Annecy,France Oct Leslie Groer Columbia UniversityDØ Calorimeter Electronics Upgrade 9 DØ Calorimeters (1) Z y x   p  Liquid argon sampling  Stable, uniform response, rad. hard, fine spatial seg.  LAr purity important  Uranium absorber (Cu or Steel for coarse hadronic)  Compensating e/   1, dense  compact  Uniform, hermetic with full coverage   < 4.2 (   2 o ),  int  total)  Energy Resolution  e:  E / E = 15% /  E  + 0.3% (e.g. 20 GeV)   :  E / E = 45% /  E + 4% (e.g. 20 GeV) p _ L. Ar in gap 2.3 mm Ur absorber 3, 4 or 6 mm Cu pad readout on 4.6 mm G10 with resistive coat epoxy

CALOR2000 Conference Annecy,France Oct Leslie Groer Columbia UniversityDØ Calorimeter Electronics Upgrade 10 DØ Calorimeters (2) Intercryostat Detector (ICD)  Arranged in semi-projective towers  Readout cells ganged in layers  Readout segmented into   for charge detection  Transverse segmentation  x  x   At shower max. (EM3)  x  x   +2.5 kV (E = 11 kV/cm) gives drift time ~ 450 ns LayerCCEC EM1,2,3,4X O : 2,2,7,10 3mm Ur X O : (0.3),3,8,9 (1.4mm Fe) 4mm Ur FH1,2,3,(4) O : 1.3,1.0,0.9 6mm Ur O : 1.3,1.2,1.2,1.2 6mm Ur CH1,(2,3) O : mm Cu O : 3.0, (3.0, 3.0) 46.5mm Fe EM FH CH OH MH IH EM Massless Gap (no absorber)

CALOR2000 Conference Annecy,France Oct Leslie Groer Columbia UniversityDØ Calorimeter Electronics Upgrade 11 Timing 3.56us 4.36us 2.64us superbunchgap 396ns gap used to form trigger and sample baselines this gap is too small to form trigger and sample baseline  Bunch structure Run I 6x6 Run II 36x36  Design all the electronics, triggers and DAQ to handle bunch structure with a minimum of 132ns between bunches and higher luminosity  Maintain detector performance

CALOR2000 Conference Annecy,France Oct Leslie Groer Columbia UniversityDØ Calorimeter Electronics Upgrade 12 Calorimeter Readout Electronics  Objectives  Accommodate reduced minimum bunch spacing from 3.5  s to 396 ns or 132 ns and L ~ 2 x cm -2 s -1  Storage of analog signal for 4  s for L1 trigger formation  Generate trigger signals for calorimeter L1 trigger  Maintain present level of noise performance and pile-up performance  Methods  Replace preamplifiers  Replace shapers  Add analog storage  Replace calibration system  Replace timing and control system  Keep Run I ADCs, crates and most cabling to minimize cost and time LAr det. preamp shaper + BLS ADC analog buffer storage L1+L2 trigger

CALOR2000 Conference Annecy,France Oct Leslie Groer Columbia UniversityDØ Calorimeter Electronics Upgrade 13 Calorimeter Electronics Upgrade 55K readout channels  Replace signal cables from cryostat to preamps (110   30  for impedance match)  Replacement of preamps, shapers, baseline subtraction circuitry (BLS)  Addition of analog storage (48-element deep Switched Capacitor Array (SCA))  New Timing and Control  New calibration pulser + current cables Preamp/ Driver Trig. sum Filter/ Shaper x1 x8 SCA (48 deep) BLS Output Buffer Detc. Bank 0 Bank 1 Replace cables for impedence match new low noise preamp & driver Shorter shaping ~400ns SCA analog storage >4  sec, alternate Additional buffering for L2 & L3 SCA new calibrated pulse injection BLS Card

CALOR2000 Conference Annecy,France Oct Leslie Groer Columbia UniversityDØ Calorimeter Electronics Upgrade 14 Preamplifier 2” FET driverpreamp similar to Run 1 version except Dual FET frontend Compensation for detector capacitance Faster recovery time New output driver for terminated signal transmission out in Preamplifier New calorimeter preamp  Hybrid on ceramic  48 preamps on a motherboard  New low-noise switching power supplies in steel box

CALOR2000 Conference Annecy,France Oct Leslie Groer Columbia UniversityDØ Calorimeter Electronics Upgrade 15 Preamp Species  14+1 (ICD) species of preamp  Feedback provide compensation for RC from detector capacitance and cable impedance  Readout in towers of up to 12 layers  0:EM1, 1:EM2, 2-5:EM3, 6:EM4, 7-10:FH, 11:CH  4 towers per preamp motherboard provides trigger tower (EM+ HAD) of  x  0.2 x 0.2 Preamp species Avg. Detector cap. (nF) Layer readout Feedback cap (pF) RC (ns) Total preamps A EM1,2, HAD B HAD C HAD D HAD E CC EM F EC EM3, G CC EM4, EC EM3, Ha-Hg2- 4 EC EM3, I— ICD

CALOR2000 Conference Annecy,France Oct Leslie Groer Columbia UniversityDØ Calorimeter Electronics Upgrade 16 L1 SCAs (2+2) L2 SCA Array of 48 capacitors to pipeline calorimeter signals BLS Card BLS motherboard v2.2 BLS daughterboard Shapers (12)  Use 2 L1 SCA chips for each x1/x8 gain - alternate read/write for each superbunch  Readout time ~ 6  s (< length SCA buffer)  L2 SCA buffers readout for transfer to ADC after L2 trigger decision  No dead time for 10KHz L1 trigger rate  Trigger tower formation (0.2 x 0.2) for L1  Rework existing power supplies  New T&C signals to handle SCA requirements and interface to L1/L2 trigger system( use FPGAs and FIFOs) Output circuit Trigger pickoff/summers ~ 1 inch shaper

CALOR2000 Conference Annecy,France Oct Leslie Groer Columbia UniversityDØ Calorimeter Electronics Upgrade 17 SCA  Designed by LBL, FNAL, SUNY Stony Brook (25k in system)  Not designed for simultaneous read and write operations  two SCA banks alternate reading and writing  12 bit dynamic range (1/4000)  low and high gain path for each readout channel (X8/X1)  maintain 15 bit dynamic range cap ref input 1” 12 channels 48 deep packaged

CALOR2000 Conference Annecy,France Oct Leslie Groer Columbia UniversityDØ Calorimeter Electronics Upgrade 18 Preamp signal shape  return to zero by about 1.2  s  Sample at 320ns  Mostly insensitive to 396 ns or 132 ns running  BLS-Finite time difference is measured  Uses three samples earlier  Pile-up  Preamp output is integral of detector signal  rise time > 430ns  recovery time 15  s  To minimize the effects of pileup, only use 2/3 of the charge in the detector  Shaped signal sampled every seven RF buckets (132ns)  peak at about 300ns After shaper Signal from preamp ns amplitude 320 ns Detector signal

CALOR2000 Conference Annecy,France Oct Leslie Groer Columbia UniversityDØ Calorimeter Electronics Upgrade 19 Noise Contributions  Design for  400ns shaping  lower noise – 2 FET input  luminosity of 2x10 32 cm –2 s -1  Re-optimized three contributions  Electronics noise:  x 1.6   shaping time (2  s  400ns) (~  t)   lower noise preamp (2 FET) (~ 1/  2)  Uranium noise:  x 2.3   shorter shaping time (~  t)  Pile-up noise:  x 1.3   luminosity (~  L)   shorter shaping times (~  t)  Comparable noise performance at with new electronics as with old electronics at  Simulations of the W mass “bench- mark” confirm that pile-up will not limit our W mass at Run II.

CALOR2000 Conference Annecy,France Oct Leslie Groer Columbia UniversityDØ Calorimeter Electronics Upgrade 20 Cell Capacitance Electronic noise Total 3.5 MeV U noise Estimates of Noise Contributions EM3 layer per cell  nF GeV

CALOR2000 Conference Annecy,France Oct Leslie Groer Columbia UniversityDØ Calorimeter Electronics Upgrade 21 Electronics Calibration Goals  Calibrate electronics to better than 1%  Measure pedestals due to electronics and Ur noise  Determine zero suppression limits  Determine gains (x1,x8) from pulsed channels  Study channel-to-channel response; linearity  Commissioning  Bad channels  Trigger verification  Check channel mapping  Monitoring tool  Oracle Database for storage  Database used to download pedestals and zero-suppression limits to ADC boards

CALOR2000 Conference Annecy,France Oct Leslie Groer Columbia UniversityDØ Calorimeter Electronics Upgrade 22 Preamp Box 2 Fanouts (2x3x16 switches ) switch Electronics Calibration System Pulser Trigger Power Supply PIB 6 commands (3x2) 96 currents Pulser Interface Board: VME interface automated calibration procedure Active Fanout with Switches: pulse shaping and distribution Open switch when receive command signal Pulser: DC current and command generator: DC current set by 18-bit DAC 96 enable registers 6-programmable 8-bit delays for command signals with 2ns step size LPNHE-Paris LAL-Orsay

CALOR2000 Conference Annecy,France Oct Leslie Groer Columbia UniversityDØ Calorimeter Electronics Upgrade 23 Calibration Pulser Response  Linear response for DAC pulse height (0-65k)  Fully saturate ADC (at DAC= 90k)  Linearity of calibration and calorimeter electronics better than 0.2% (for DAC < 65k)  Cross-talk in neighboring channels < 1.5%  Uniformity of pulser modules better than 1%  No significant noise added from the calibration system  Correction factors need to be determined  mean Deviation from linearity Single channel (ADC vs. DAC) better than 0.2%

CALOR2000 Conference Annecy,France Oct Leslie Groer Columbia UniversityDØ Calorimeter Electronics Upgrade 24 Pulser Signal Shapes Calorimeter Signal at Preamp Input Calibration Signal at Preamp Input Calorimeter Signal after Preamp and Shaper Calibration Signal after Preamp and Shaper 400ns  Response of calorimeter signal w.r.t. calibration signal < 1% at max. signal for variation of different parameters (cable length, Z preamp, Z cable,…)  No test beam running  absolute energy scale will have to be established from the data  Maximum response time for EM and hadronic channels differ due to different preamp types. Use delays and modeling to accommodate these  Correct pulser response for different timings and shape  Use initial “guess” based on Monte-Carlo sampling weights and Spice models of the electronics. Signal reflection

CALOR2000 Conference Annecy,France Oct Leslie Groer Columbia UniversityDØ Calorimeter Electronics Upgrade 25  EM Scale  Z  ee (100k) sets the absolute EM scale  Check with   0  ,  J/  or  (1S)  ee  Use W  e  sample (1.6M) to check symmetry in   Jet Energy Scale   + jet data  possibly also Z + jet, (Z  ee/  )  very low backgrounds and harder Et spectrum but low statistics  We have E/p this time! Determining EM/Jet Energy Scale Z  ee J/   ee   ee

CALOR2000 Conference Annecy,France Oct Leslie Groer Columbia UniversityDØ Calorimeter Electronics Upgrade 26 Effect of added material  New solenoid and preshower detectors increased the radiation length  Degrades both energy response and resolution  Introduces non- uniformity in  response 50 GeV electron  X0X0 central forward

CALOR2000 Conference Annecy,France Oct Leslie Groer Columbia UniversityDØ Calorimeter Electronics Upgrade 27 Optimization of Calorimeter Response  Minimize  (E true -  a i E i ) 2  a i = layer weighting  E i = layer Energy  Utilizing these energy correlations improves energy uniformity and resolution by ~10% 50 GeV  50 GeV e   E/E

CALOR2000 Conference Annecy,France Oct Leslie Groer Columbia UniversityDØ Calorimeter Electronics Upgrade 28 Liquid Argon Monitoring  Each cryostat has four cells  241 Am sources – 5 MeV , 0.1  Ci  gives about 4 fC in Lar gap with 500Hz trigger rate  Check LAr response (constant to < 0.5% in Run I)  106 Ru (< 3.5 MeV , 1yr half-life)  one stronger source (~ Ci) should give about 0.3Hz triggers (about 2 fC)  Check LAr purity (< 1% in Run I)  Mainz group design (based on ATLAS)  Separate HV, preamplifier and trigger system  Preamplifier and differential driver give gain of about 50  gives signals of about 0.1V  Shaping and ADC on receiver boards (FPGA)  On board collection and storage of histogram information  Extract data over CAN-bus

CALOR2000 Conference Annecy,France Oct Leslie Groer Columbia UniversityDØ Calorimeter Electronics Upgrade 29 Conclusions  Dzero is upgrading its detector  L.Argon calorimeter untouched  Harder machine conditions and new environment (solenoid) –New Calorimeter Electronics –Improved ICD –New Central and Forward Preshower  Similar performance with 20x more data  Run II start in 6 months watch this space!!!