A Comparison of the Original vs. Modified Continuous Glucose Monitoring System (CGMS™) Sensor During Hypoglycemia in the Diabetes Research in Children.

Slides:



Advertisements
Similar presentations
Down Alert Function of the GlucoWatch® G2 TM Biographer (GW2B) During Insulin- induced Hypoglycemia in Children Eva Tsalikian 1, Craig Kollman 2, Rosanna.
Advertisements

Continuous Glucose Monitoring Thomas Repas D.O. Diabetes, Endocrinology and Nutrition Center, Affinity Medical Group, Neenah, Wisconsin Member, Inpatient.
INTRODUCTION TO CONTINUOUS GLUCOSE MONITORS
Diabetes Self-Management Profile- Revised for Conventional and Flexible Insulin Regimens Wysocki, T. 1, Xing, D. 2, Fiallo-Scharer, R. 3, Doyle, E. 4,
Area 4 SHARP Face-to-Face Conference Phenotyping Team – Centerphase Project Assessing the Value of Phenotyping Algorithms June 30, 2011.
Continuous Glucose Monitoring. Diabetes Management Evolution Insulin Delivery Glucose Monitoring 2000 First CGM system 2006 Paradigm REAL- Time, combining.
1 GLUCOWATCH ® G2™ BIOGRAPHER H. PETER CHASE, MD I)INTRODUCTION II)ACCURACY DATA III) HOME PILOT TRIAL IV) DIRECNET STUDY GROUP V) SUMMARY.
Ambulatory Blood Pressure Profiles in Adolescents with Type 1 Diabetes Andrew J. Ellis 1,2, B.A.; David M. Maahs 2, M.D. Ph.D.; Franziska K. Bishop 2,
Copyright restrictions may apply JAMA Pediatrics Journal Club Slides: Decreasing Hospital LOS for Bronchiolitis Sandweiss DR, Mundorff MB, Hill T, et al.
DAVID C KLONOFF, MD Medical Director Dorothy L. and James E. Frank Diabetes Research Institute of Mills-Peninsula Health Services Clinical Professor of.
Diabetes Update: Living Life after Lente
1 INTRODUCTION TO CONTINUOUS GLUCOSE MONITORS H. Peter Chase, MD Vicky Gage, RN, CDE Laurel Messer, RN, CDE Susie Owen, RN, CDE Sally Sullivan, RN, CDE.
OLSON, M.L., ET AL Vitamin D Deficiency in Obese Children an Its Relationship to Glucose Homeostasis J CLIN ENDOCRINOL METAB, 97, , 2012.
1 Progress Towards an Artificial Pancreas for T1D WILLIAM TAMBORLANE, MD Chief of Pediatric Endocrinology, Yale University, Deputy Director, Yale Center.
Suhyla Alam (Eastern Virginia Medical School), Amy West, Maura Downey, Jane EB Reusch, Kristen Nadeau University of Colorado Denver and Children’s Hospital.
Accuracy of the FreeStyle Navigator ™ Continuous Glucose Monitor Diabetes Research in Children Network Larry Fox, 1 Roy Beck, 2 Stuart Weinzimer, 3 Katrina.
Diabetes Research in Children Network (DirecNet) Outpatient Pilot Study to Evaluate the GlucoWatch® G2 TM Biographer in the Management of Type 1 Diabetes.
Accuracy of the A1cNow ® in Children with T1D. Diabetes Research in Children Network Larry Fox, 1 Dongyuan Xing, 2 Katrina Ruedy, 2 Roy Beck, 2 Craig Kollman,
Limitations of Statistical Measures of Error in Assessing the Accuracy of Glucose Sensors Craig Kollman1, Darrell Wilson2, Tim Wysocki3, Rosanna Fiallo-Scharer4,
Practical Aspects of Continuous Glucose Monitoring 2008 Rosanna Fiallo-Scharer, MD Laurel Messer, RN, BSN, CDE Barbara Davis Center for Childhood Diabetes.
Can Bright Futures Be Implemented in a Busy Clinical Setting? Lessons Learned from the Preventive Services Improvement Project: A National Collaborative.
Diabetes Research in Children Network (DirecNet) Outpatient Pilot Study to Evaluate the Feasibility of Computer-Based Data Acquisition and Transmission.
A 5-center CRC-based Study of the Accuracy of the GlucoWatch® G2 TM Biographer in Children and Adolescents with Type 1 Diabetes Darrell Wilson 1, Bruce.
Inhaled Human Insulin Treatment in Patients with Type 2 Diabetes Mellitus Matthew Faiman.
Mealtime Glycemic Excursions in Pediatric Subjects with Type 1 Diabetes: Results of the Diabetes Research in Children (DirecNet) Accuracy Study Study Group.
Chronic Diabetes Case F Gestational Diabetes Mellitus (GDM) Clinical Pathology B Hoa Nguyen Tuan Anh Tran Thi Thuy Duong Trang.
Closed-Loop Insulin Delivery in Children
Figure 2. The efficiency with the different optimizations compared to the standard design. 100 % effeciency indicates no improvement compared to the standard.
Abstract Background: As part of a study to evaluate the accuracy of the GlucoWatch ® G2 TM Biographer and the Continuous Glucose Monitoring System (CGMS.
© Copyright 2009 by the American Association for Clinical Chemistry Glucose Meter Performance Criteria for Tight Glycemic Control Estimated by Simulation.
Effects of Pediatric Asthma Education on Hospitalizations and Emergency Department Visits: A Meta-Analysis June 3, 2007 Janet M. Coffman, PhD, Michael.
Diabetes Control and Complications Trial (DCCT) Results indicate that most youth with T1DM should be treated intensively in order to reduce the risk of.
Background: DirecNet Diabetes Research in Children Network NIH funded collaborative study group 5 clinical centers, central laboratory, coordinating center,
Diabetes Research in Children Network Pilot Study of the Navigator TM Continuous Glucose Monitoring System in Children with Type 1 Diabetes: Safety, Tolerability,
Marta Alves, Celestino Neves, Ana Varela, Cristina Arteiro, Luís Miguel Pereira, Davide Carvalho, José Luís Medina. Endocrinology Service, S. João Hospital,
Journal Club 埼玉医科大学 総合医療センター 内分泌・糖尿病内科 Department of Endocrinology and Diabetes, Saitama Medical Center, Saitama Medical University 松田 昌文 Matsuda, Masafumi.
OLSON, M.L., ET AL Vitamin D Deficiency in Obese Children an Its Relationship to Glucose Homeostasis J Clin Endocrinol Metab, 97, , 2012.
Event-Based Assessments of Sensor Accuracy during Exercise-Induced Reductions in Glucose in Children with Type 1 Diabetes Craig Kollman, 1 Darrell Wilson,
Impact of Exercise on Overnight Glycemic Control in Children with Type 1 Diabetes (T1DM) Eva Tsalikian 1 ; Roy Beck 2 ; Peter Chase 3 ; Tim Wysocki 4 ;
Tips for Researchers on Completing the Data Analysis Section of the IRB Application Don Allensworth-Davies, MSc Statistical Manager, Data Coordinating.
Internet-based pilot study comparing low fat with high fat evening snacks in children and adolescents with Type 1 Diabetes using continuous glucose monitoring.
Use of The FreeStyle Navigator TM Continuous Glucose Monitoring System in Children on Glargine- based Multiple Daily Injection Therapy Stuart Weinzimer.
Use of the FreeStyle Navigator ™ Continuous Glucose Monitoring System in Children with Type 1 Diabetes Diabetes Research in Children Network L. A. Fox,
Lack of Effectiveness of the GlucoWatch Biographer (GW2B) in Altering Glycemic Control in Children with Type 1 Diabetes H. Peter Chase 1, Roy Beck 2, William.
Utility of CGMS as a Measure of Glycemic Control in Children with Type 1 Diabetes (T1DM) Rosanna Fiallo-Scharer, MD for.
Reliability of two indices of the biologic variability in glycosylation among children and adolescents with T1DM Darrell M Wilson 1, Rosanna Fiallo-Scharer.
Comparison of Modified ETDRS and Mild Macular Grid Laser Photocoagulation Strategies for Diabetic Macular Edema Sponsored by the National Eye Institute,
Effectiveness of Early Intensive Therapy On β-Cell Preservation in Type 1 Diabetes Featured Article: Bruce Buckingham, M.D., Roy W. Beck, M.D., P.H.D.,
Healthcare Across Borders - September 2003 Head-To-Head Comparison Of The Two Currently Available Continuous Monitors North County Endocrine 700 West El.
APPLICATION OF INDIVIDUALIZED BAYESIAN UREA KINETIC MODELING TO PEDIATRIC HEMODIALYSIS Olivera Marsenic, Athena Zuppa, Jeffrey S. Barrett, Marc Pfister.
OLSON, M.L., ET AL Vitamin D Deficiency in Obese Children an Its Relationship to Glucose Homeostasis J Clin Endocrinol Metab, 97, , 2012.
Evaluation of Factors Affecting CGMS Calibration Bruce Buckingham, 1 Craig Kollman, 2 Roy W Beck, 2 Andrea Kalajian, 2 Rosanna Fiallo-Scharer, 3 Michael.
Accuracy Study of the Medtronic Minimed Continuous Glucose Monitoring System (CGMS) and GlucoWatch® G2TM Biographer (GW2B) in Children with Type 1 Diabetes.
Overnight Closed-Loop Insulin Delivery in Young People With Type 1 Diabetes: A Free- Living, Randomized Clinical Trial Featured Article: Roman Hovorka,
Alterations in White Matter Structure in Young Children With Type 1 Diabetes Featured Article: Naama Barnea-Goraly, Mira Raman, Paul Mazaika, Matthew Marzelli,
Performance of the DCA 2000 ® + Analyzer for Measurement of Hemoglobin A1 c Levels in Children with T1DM in a DirecNet Outpatient Clinical Trial.
Multidisciplinary Diabetes Team Activities in a 196 Bed Community Hospital Robin Southwood, Pharm.D, CDE and Beth Melvin, RD, MS, CDE.
DirecNet Study of the Accuracy of the Navigator Continuous Glucose Monitoring System in Children and Adolescents with Type 1 Diabetes Darrell Wilson 1,
The Physiological Variations of Plasma Glucose Concentrations in Healthy, Non-Diabetic Children: Use of Continuous Glucose Sensors Nelly Mauras, Roy Beck,
1 INTRODUCTION Nearly 25% of diabetes patients use insulin Many practitioners: –Are uncomfortable with insulin dosing –Base dosing decisions on empiric.
Gerti Tashko, M.D. DM Journal Club 12/16/2010. The use of exenatide with insulin is not FDA approved. The study was designed to evaluate if exenatide.
TEMPLATE DESIGN © CONTINUOUS GLUCOSE MONITORING, ORAL GLUCOSE TOLERANCE, AND INSULIN – GLUCOSE PARAMETERS IN ADOLESCENTS.
Date of download: 6/24/2016 From: Comparative Effectiveness and Safety of Methods of Insulin Delivery and Glucose Monitoring for Diabetes Mellitus: A Systematic.
Daniel A. Baur, Fernanda S. Vargas, Jordan A. Garvey, Christopher W. Bach, and Michael J Ormsbee, FACSM Institute of Sports Sciences and Medicine, Department.
1 Establishment of Blood Glucose Monitoring System Using the Internet Diabetes Care 27:478–483, 2004 Long-Term effect of the Internet-Based Glucose Monitoring.
Date of download: 6/26/2016 From: Comparative Effectiveness and Safety of Methods of Insulin Delivery and Glucose Monitoring for Diabetes Mellitus: A Systematic.
The Effect of NAVA on Parameters of Ventilation in the Pediatric Intensive Care Unit Cynthia C. White, BA, RRT-NPS, AE-C, FAARC; Brandy Seger, BS, RRT-NPS;
Copyright © 2004 American Medical Association. All rights reserved.
17-alpha Hydroxyprogesterone caproate did not reduce the rate of recurrent preterm birth in a prospective cohort study David B. Nelson, MD; Donald D. McIntire,
Intranasal Glucagon Investigators
Presentation transcript:

A Comparison of the Original vs. Modified Continuous Glucose Monitoring System (CGMS™) Sensor During Hypoglycemia in the Diabetes Research in Children Network (DirecNet) Accuracy Study Michael Tansey 1, Roy Beck 2, Bruce Buckingham 3, Nelly Mauras 4, Rosanna Fiallo-Scharer 5, Dongyuan Xing 2, William Tamborlane 6, Katrina Ruedy 2, and the Diabetes Research in Children Network (DirecNet) Study Group. 1 Department of Pediatrics, University of Iowa, Carver College of Medicine, Iowa City, IA; 2 Jaeb Center for Health Research, Tampa, FL; 3 Division of Pediatric Endocrinology and Diabetes, Stanford University, Stanford, CA; 4 Nemours Children’s Clinic, Jacksonville, FL; 5 Barbara Davis Center for Childhood Diabetes, University of Colorado, Denver, CO; 6 Department of Pediatrics, Yale University School of Medicine, New Haven, CT.

The CGMS has been used to follow glucose trends in patients with type1 diabetes, however the accuracy of this device to document hypoglycemia has not been completely evaluated. Recently, the manufacturer of CGMS(Medtronic MiniMed, Northridge, CA) developed a modified glucose sensor using a new fabrication process. To study the accuracy of these sensors, the DirecNet study group examined 91 patients, 3-17 years of age with type 1 diabetes. CGMS glucose values were compared with simultaneous reference venous glucose values, sampled every minutes for 24 hours and every 5 minutes for up to 90 minutes during an insulin-induced hypoglycemia test. When all sensor values were analyzed, the 25 CGMSs using modified sensors were substantially more accurate than the 115 CGMSs using original sensors in median error (11% versus 19%, P 100 mg/dL. Only 8 of 26 overnight hypoglycemic episodes detected by original sensors were RG confirmed, whereas all 3 detected by modified sensors were RG confirmed. Conclusion: Recent modifications to the CGMS sensor have resulted in substantially better accuracy. However, even the modified sensors differ substantially from RG glucose values in the hypoglycemic range. ABSTRACT

Background Continuous Glucose Monitoring System (CGMS™) was the first glucose sensor to be approved by the FDA CGMS is capable of measuring interstitial fluid glucose every 5 minutes for up to 72 hours In November, 2002 Medtronic MiniMed changed the manufacturing process of the sensor that had been in place since 1999 by modifying the sensor fabrication process To evaluate the accuracy of the original and modified CGMS sensors in children and adolescents with type 1 diabetes mellitus, by comparing sensor values to reference glucose levels Objective

Methods Data pooled from three studies: Inpatient Accuracy Study –91 patients admitted to a CRC for hours to evaluate accuracy of the CGMS –One or two CGMS sensors inserted in each patient –Blood samples collected every 60 min during the day, every 30 min overnight, and every 5 minutes for up to 90 minutes during an IV insulin induced hypoglycemia test Outpatient Pilot Study –15 patient pilot study designed to evaluate the feasibility of electronic data collection from a computer used in the patients’ homes –CGMS used by 10 patients prior to 3-month visit for hours –On 2 days of CGMS use, 8-point blood glucose testing performed with Ultra Outpatient Randomized Trial (RCT) –Ongoing study of 200 patients –All patients provided with home computer and UltraSmart meter –CGMS used by all patients for hours at Baseline, 3 and 6 months –On 2 days of CGMS use, 8-point blood glucose testing performed with UltraSmart –Data available from Baseline on 103 patients

Demographics

Data Analysis CGMS glucose measurements were matched to reference measurements within 2.5 min of each other –Inpatient Study reference values: IV blood samples measured in a central laboratory –Pilot Study and RCT reference values: home glucose meter CGMS time was adjusted by 2.5 min to account for averaging of glucose levels made over the previous 5 min When comparing CGMS monitors simultaneously, sensor values were matched within 2.5 min of each other

Sensory Accuracy for Reference Glucose Values <60 mg/dL * Absolute value of sensor glucose minus reference glucose.

Sensor Accuracy Inpatient Study Pilot and RCT Studies Original Sensors N=4643 Paired Values Modified Sensors N=999 Paired Values Modified Sensors N=1262 Paired Values Relative Absolute Difference Median (25 th, 75 th percentiles) 19% (9%, 34%) 11% (5%, 23%) 12% (5%, 23%) ISO Criteria Met According to Reference Glucose Level ≤70 mg/dL37%44%67% mg/dL44%64%65% mg/dL52%71% mg/dL60%77%75% >240 mg/dL59%80%77% All Values54%72%

Effect of Glucose Concentration on Accuracy Assessed by Median RAD% Original CGMS (Inpatient) Modified CGMS (Inpatient) Modified CGMS (Pilot / RCT)

Conclusions The modified CGMS sensor offers improved accuracy compared to the original sensor at all glucose ranges that were measured There is decreased accuracy of both sensors in the hypoglycemic ranges when compared to the reference glucose

Barbara Davis Center –H. Peter Chase –Rosanna Fiallo-Scharer –Jennifer Fisher –Barbara Tallant University of Iowa –Eva Tsalikian –Michael Tansey –Linda Larson –Julie Coffey –Amy Sheehan Nemours Children’s Clinic –Tim Wysocki –Nelly Mauras –Keisha Bird –Kelly Lofton Stanford University –Bruce Buckingham –Darrell Wilson –Jennifer Block –Paula Clinton Yale University –William Tamborlane –Stuart Weinzimer –Elizabeth Boland –Kristen Sikes –Amy Steffen Jaeb Center for Health Research –Roy Beck –Katrina Ruedy –Craig Kollman –Dongyuan Xing –Cynthia Silvester