 COMSOFT GmbH | NetTEST II | July 2005 | Page 1 NetTEST II PROFIBUS Analysis Tool Professional Test Tool for PROFIBUS-DP-Networks.

Slides:



Advertisements
Similar presentations
Network II.5 simulator ..
Advertisements

Yokogawa Network Solutions Presents:
Smart.IC II project Forklift truck connection Forklift truck connection, outside of the connector Automatic data download through GPRS and anlaysis of.
COMSOFT GmbH | NetTEST II | June 2009 | Page 1 Professional Test Tool for PROFIBUS DP Networks NetTEST II PROFIBUS Analysis and Test Tool.
5387 Avion Park Drive Highland Heights, Ohio INTUNE v4.4 Demonstration.
DeviceNet 2400, 2500, 26/2700.
Basic Jens Neigaard.
easyEmission - 1st Steps & Overview
/// MELSEC Safety /// QS001CPU /// QS0J61BT12 /// QS0J65BTB2-12DT /// MELSEC Safety /// Mitsubishi Electric - MELSEC Safety - Training Documentation -
MLC Connectivity to SLC 500 via DeviceNet
Troubleshooting Training Course.  Visual and General Test  Perform System Test (Mode  Perform System Test)  Identify The Error  If you need Technical.
LogTag Training January 2015
Protocol Configuration in Horner OCS
1/1/ / faculty of Electrical Engineering eindhoven university of technology Architectures of Digital Information Systems Part 1: Interrupts and DMA dr.ir.
Modbus Slave & Modbus Master in S7
 COMSOFT GmbH | LabVIEW PROFIBUS VISA Driver | March 2009 LabVIEW PROFIBUS VISA Driver.
June 2010 At A Glance The Room Alert Adapter software in conjunction with AVTECH Room Alert™ devices assists in monitoring computer room environments as.
Advanced Workgroup System. Printer Admin Utility Monitors printers over IP networks Views Sharp and non-Sharp SNMP Devices Provided Standard with Sharp.
Slide 1 Industrial Automation - Customer View - Training PhW - CANopen_en 02/ 2002 CANopen QUIZ CANopen QUIZ.
Active Stations PC PLC PROFIBUS Passive Stations (Field Devices)
SMART. ON Battery monitor Measured instantaneous data: V, I, T, and A Storage and analysis of history data Statistics analyses Programming of charging.
Chapter 19: Network Management Business Data Communications, 4e.
Network+ Guide to Networks, Fourth Edition
AS-i, The Simplest Automation Networking Solution Dated: 10/30/2008.
Moeller GmbH BU Circuit Breaker Protective note to rule DIN ISO is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner Aug 03,
Setup Guide - Profibus communication AC141x with Step 7 V5.5 English
Notes: For the installation of a PB network, you can use shielded twisted pair copper cable, glass or plastic FO and infrared components. And you can mix.
1  Module Type Overview  Construction  Characteristics  Installation principles  Details PD 600-Series.
Slide 1 / 20 Industrial Automation - Custumer View - Services PhW - Modbus_en 06/ 2002 Modbus training.
Graphical Alarm Management System
Connecting LANs, Backbone Networks, and Virtual LANs
HiVision SNMP Software.
This is the way an organisation distributes the data across its network. It uses different types of networks to communicate the information across it.
SCADA and Telemetry Presented By:.
1. 2 How do I verify that my plant network is OK? Manually: Watch link lights and traffic indicators… Electronically: Purchase a SNMP management software.
USART Communication using the RS standard ETEC6416.
0 RS-485 MODBUS COMM. D. Digital Trip Relay 6. IO (Input-Output) Port Profibus -DP COMM. Digital Trip Relay - P and S type are equipped with RS- 485 communication.
technical basics The PROFIBUS protocols Wiring
PROFIBUS PA Date 09/19/00, Page 1 PROFIBUS PA s  PROFIBUS PA = PROFIBUS for Process Automation PA is based on the DP and DP Extended protocol DP Master.
Booting in Windows XP Presented and Designed By: Luke Ladd.
Hands-On Microsoft Windows Server 2008
Diagnostic & Troubleshooting Date 06/09/00, Page 1 Diagnostic & Troubleshooting s.
PROFIBUS wiring/installation can be done with:
Technology Date 10/17/00, Page 1 Technology s PROFIBUS Technology Chips - Modules - Development Kits.
Welcomes you ! To a Gateway for Total Project Planning, Review, Cost Monitoring & Reports
Area Of Study 2 Information And Communications Technology(ICT)
1 © 2003, Cisco Systems, Inc. All rights reserved. CCNA 2 Module 9 Basic Router Troubleshooting.
I/O Example: Disk Drives To access data: — seek: position head over the proper track (8 to 20 ms. avg.) — rotational latency: wait for desired sector (.5.
SunGuide® Software Development Project Release 4.3 Express Lanes Enhancements Design Review December 15, 2009 December 15, 20091R4.3 Design Review.
PROFIBUS Bus Monitor Monitor Features
1 Network Monitoring Mi-Jung Choi Dept. of Computer Science KNU
CCNA 2 Week 1 Routers and WANs. Copyright © 2005 University of Bolton Welcome Back! CCNA 2 deals with routed networks You will learn how to configure.
Date: File:PRO1_12E.1 SIMATIC S7 Siemens AG All rights reserved. Information and Training Center Knowledge for Automation Troubleshooting.
All rights reserved, property and © CAD Computer GmbH & Co.KG 2009 Cover Page.
Computer Networks. A computer network is defined as the interconnection of 2 or more independent computers or/and peripherals. Computer Network.
Chapter 2 Basic Principle of PLC PLC Configuration &Function   Basic Configuration  CPU  Memory  Programming Interface  Communication.
11 INSTALLING AND MANAGING HARDWARE Chapter 6. Chapter 6: Installing and Managing Hardware2 INSTALLING AND MANAGING HARDWARE  Install hardware in a Microsoft.
McGraw-Hill©The McGraw-Hill Companies, Inc., 2004 Connecting Devices CORPORATE INSTITUTE OF SCIENCE & TECHNOLOGY, BHOPAL Department of Electronics and.
NETWORKING FUNDAMENTALS. Network+ Guide to Networks, 4e2.
Network Troubleshooting
Profibus. PLC PROFIBUS active stations, master devices DriveActuatorTransmitter passive stations, slave devices Sensor Drive logical token ring between.
Install, configure and test ICT Networks
CMV-NET Chigo VRF Network Centralized Control System
Quick help for fault location and reliable detection of defects
Professional Test Tool for PROFIBUS DP Networks
Siemens Step 7 Project with Controllere in 7 Steps: Step 1
NetTEST II PROFIBUS Analysis Tool
Professional Test Tool for PROFIBUS DP Networks
Training Module Introduction to the TB9100/P25 CG/P25 TAG Customer Service Software (CSS) Describes Release 3.95 for Trunked TB9100 and P25 TAG Release.
Quick help for fault location and reliable detection of defects
Presentation transcript:

 COMSOFT GmbH | NetTEST II | July 2005 | Page 1 NetTEST II PROFIBUS Analysis Tool Professional Test Tool for PROFIBUS-DP-Networks

 COMSOFT GmbH | NetTEST II | July 2005 | Page 2 NetTEST II – available in 3 versions NetTEST II with Online-Function for the use with operational Profibus networks NetTEST II with Online-Function for the use with operational Profibus networks NetTEST II with DP-Mono-Master function for DP-Slave configuration NetTEST II with DP-Mono-Master function for DP-Slave configuration NetTEST II Basis System for performing physical measurements NetTEST II Basis System for performing physical measurements

 COMSOFT GmbH | NetTEST II | July 2005 | Page 3 NetTEST II – thoroughly checks your PROFIBUS DP-Network   95% of all problems in PROFIBUS DP-Networks are caused by incorrect installations. Installation errors increase interference susceptibility enormously, whether it is a missing terminator or a broken shield. This results in sporadic non-reproducible errors, which can be caused for example by an increased EMC-load. Trouble shooting can cost days or even weeks.   NetTEST II checks your PROFIBUS DP-Networks in detail and detects most typical installation problems.   Find out for yourself that NetTEST II proves to be a powerful tool for eliminating PROFIBUS problems. Costs Stop of delay Interruption Standstill of Delays

 COMSOFT GmbH | NetTEST II | July 2005 | Page 4 NetTEST II – a flexible system for mobile operation   Graphical 128 x 64 Pixels LCD- Display with background illumination   Power supply via a rechargeable battery pack   Battery capacity for approximately 4 hours of operation   9-pole SUB-D – gender changer for connection to PC and PROFIBUS   6 x 4 - Keyboard   Complete transport case with international battery charging set incl. power supply, additional battery, power supply adapter, Profibus-Configurator and various adapter cables for PC and PROFIBUS

 COMSOFT GmbH | NetTEST II | July 2005 | Page 5 NetTEST II – performs detailed measurements on physical level of the PROFIBUS line Determines the Impedance Cable Length as well as the of the connected PROFIBUS line

 COMSOFT GmbH | NetTEST II | July 2005 | Page 6 NetTEST II – discovers most of the typical installation problems   Disruption of strand A, strand B and shield (with distance measured in m)   Correct terminating resistor (number and value) V   Non-powered terminating resistors   Branches (with distance measured in m)   Inhomogeneous line segments (with distance measured in m)   Short circuits (with distance measured in m)   Switched pairs of strands

 COMSOFT GmbH | NetTEST II | July 2005 | Page 7 NetTEST II – contains helpful analysis functions for superior error detection   Display of Live List of DP-Slaves   Display of Ident-Numbers of DP-Slaves   Signal Quality of DP-Slaves   Baud Rate Detection und Signal Quality at Running Systems

 COMSOFT GmbH | NetTEST II | July 2005 | Page 8 NetTEST II – logs & archives your measurements   Generation, display and storage of up to 20 test reports   Management and archiving of the test reports via connected PC or notebook   Communication from PC to NetTEST II via COM-interface und standard-terminal-software (e.g.Hyperterminal). No special software is required.

 COMSOFT GmbH | NetTEST II | July 2005 | Page 9 NetTEST II Measurement report Analysis of the tested PROFIBUS segment at one glance. All requirements of modern quality systems are met:   Evidence of Functionality   Archiving   Traceability   Reproducibility ************************************************ Resulting protocol for PROFIBUS Network ************************************************ SW V /21 Test company Name : COMSOFT GmbH Str. : Wachhaustr. 5a City : Karlsruhe Phone: 0721/ Mail : http/ User name : Kurpat ************************************************ Customer Name : COMSOFT GmbH Str. : Wachhausstr. 5a City : Karlsruhe Phone: 0721/ Mail : *********************************************** Unit : Area 1 Name: Segment 1 Own profibus address: 001 Number of 12Mbit/s-conns in seg. : 000 Number of profibus-devices in seg. : 002 Baud rate: 1.5 Mbaud Slot time: Date: 15/11/01 Time: 17:03:57 *********************************************** Analysation result for Test with no term. Analyzation result : No fault! ***************************************** Irregularity A B not detectable Irregularity B Shield not detectable Irregularity A Shield not detectable capacitive load junction or Impedance changes not detectable Broken line not detectable Cabling ok Impedance app 133 ohms Cable length 26m ********************************************************* Analysation result for Test with 1 term. Analyzation result : No fault! **************************************** Irregularity B Shield not detectable Irregularity A Shield not detectable Correct termination Number of retries: 3 ********************************************************* Analysation result for Test with 2 term. Analyzation result : No fault! **************************************** Irregularity B Shield not detectable Irregularity A Shield not detectable Correct termination Number of retries: 1 ********************************************************* Detected slaves in segment PB addr.: Level: Status: Ident.: [Name:] V Reflections 0x V Reflections 0x9510 -> XPS9510 Expected value for level measure : 2.5v<x<7.2v ******

 COMSOFT GmbH | NetTEST II | July 2005 | Page 10 Performing the measurement

 COMSOFT GmbH | NetTEST II | July 2005 | Page 11 Strand A * Terminating resistor 1 * Strand B * Terminating resistor 2 * Shield * DP-Master and DP-Slaves * 0 V +5 V Terminating Resistor 0 V +5 V Terminating Resistor Shield A A typical Profibus-DP-RS485 segment consists of: B DrivesGateways Field Device Master

 COMSOFT GmbH | NetTEST II | July 2005 | Page 12 0 V +5 V Terminating Resistor NetTEST II is connected instead of the DP-Master at either one of the two bus ends 0 V +5 V Terminating Resistor Shield Connection with the PROFIBUS DP-Slaves can be left connected to the bus in online mode B A DrivesGateways Field Device Master

 COMSOFT GmbH | NetTEST II | July 2005 | Page without terminating resistors 2. with one terminating resistors 3. with both terminating resistors 0 V +5 V Terminating Resistor 0 V +5 V Terminating Resistor A Shield Performing a 3- stage test B Drives GatewaysField Device During the measurement procedure NetTEST II requests the user to switch on and off the respective terminating resistors

 COMSOFT GmbH | NetTEST II | July 2005 | Page 14 Simple & quick adaptation to the DP segment subject of measurement   PROFIBUS address   System Baud rate   Slot time   Number of 12 MBit plugs used   Number of devices connected to the bus

 COMSOFT GmbH | NetTEST II | July 2005 | Page 15 Useful information for physical measurements   The physical measurement of the PROFIBUS line is only carried out within electrical segments, without including repeaters.   The minimum length of line to be measured is 10 m. The shorter the line lengths, the more inexactly the measurement may become.   Only active stations (masters) have to be disconnected from the bus, slaves may stay connected.   NetTEST II is designed for standard PROFIBUS-Cable type A (150 Ohm surge impedance, core cross section >0,34 mm²). Different types of cables, e.g. obsolete cable type B (100 Ohm surge impedance) are not to be used and are recognized as faulty by NetTEST II. Start

 COMSOFT GmbH | NetTEST II | July 2005 | Page 16 NetTEST II with DP-Master function for mobile setting into operation   Setting into operation of DP-Slaves without time- consuming implementation of an SPS   Configuration of DP-Slaves via comfortable PC tool on the basis of GSD file and integrated download function   Comfortable access to the I/O-Data of DP-Slaves via freely definable tags   Display and Coding of DP-Slave diagnostic data

 COMSOFT GmbH | NetTEST II | July 2005 | Page 17 The COMSOFT PROFIBUS-Configurator supplies NetTEST II with the DP-Slave configuration NetTEST II – Trouble-free & comfortable

 COMSOFT GmbH | NetTEST II | July 2005 | Page 18 NetTEST II – Multi-Talent as DP-Master   Changing all DP-Slave parameters   Execution of single PROFIBUS-DP services   Simple DP-Slave start-up – not just for PROFIBUS experts   Direct access to selective I/O-Data, e.g. digital outputs Start

 COMSOFT GmbH | NetTEST II | July 2005 | Page 19 NetTEST II with Online Function up to 12 Mbit/s anotherhighlight NetTEST II with Online Function up to 12 Mbit/s – another highlight   NetTEST II was enhanced by very powerful online measurement functions which even on the operative Profibus give detailed information about existing installation problems.

 COMSOFT GmbH | NetTEST II | July 2005 | Page 20 Measurements on the operative Bus DrivesGatewaysField Devices Master

 COMSOFT GmbH | NetTEST II | July 2005 | Page 21 Measurements with PLC   Baud rate detection   Generate live list   Rotation time   Signal level measurement   Signal level summary list   Event log   Event count   Diagnostic event The following measurements can be conducted in online mode:

 COMSOFT GmbH | NetTEST II | July 2005 | Page 22 Baud rate detection   During this Baud rate scan the overall signal quality at the Profibus is measured and a status is indicated.

 COMSOFT GmbH | NetTEST II | July 2005 | Page 23 Generating a Live List Current Slave Live List   NetTEST II analyses the bus traffic and generates a Live List of all active and passive bus subscribers broken down by Masters and Slaves. Current Master Live List

 COMSOFT GmbH | NetTEST II | July 2005 | Page 24 Rotation Time   NetTEST II determines the time the DP-Master needs in order to poll all configured DP-Slaves.   The minimum and maximum values are stored and indicated. Rotation time is an explicit indicator for performance problems, e.g. in a sporadically disfunctional Profibus network

 COMSOFT GmbH | NetTEST II | July 2005 | Page 25 Level measurement   NetTEST II measures the signal quality of each DP-Slave and visualises the value in a bar graph. Discrepancies of the measured signal levels from the allowed range point to specific errors of the Profibus network, e.g. signal levels above the allowed maximum are typical for reflexions in the profibus network.

 COMSOFT GmbH | NetTEST II | July 2005 | Page 26 Signal level sum list   In the signal level sum list, the result of the signal level measurement is indicated in form of a table: -ADD – Participant address -COUNT – Number of measurements (excl. Time-outs) -MIN – Minimum Values -AV – Average Values -MAX – Maximum Values

 COMSOFT GmbH | NetTEST II | July 2005 | Page 27 Event log   NetTEST II analyses the data traffic between DP- Master and DP-Slaves and triggers upon communication status changes. The event log is represented in form of a table: - ADD – DP-Slave address - DATA OK – DP-Slave is in status of data exchange - NR – No Response, DP-Slave is not responding - TRY – DP-Slave responds only after multiple retries by DP Master - CFG – DP-Slave was parameterised or configured - DIA – Diagnostic messages pending at DP-Slave

 COMSOFT GmbH | NetTEST II | July 2005 | Page 28 Event count   Should a singular DP-Slave show communication problems in the event protocol, it can be analysed in detail by the event counting.   The event count shows the communication statistic for a single DP-Slave in detail. Also retries and communication errors are counted.

 COMSOFT GmbH | NetTEST II | July 2005 | Page 29 Diagnostic event   The diagnostic event is an extended function of the event counting and serves the detailed analysis of an event.   NetTEST II offers the choice between 6 events that may be triggered, e.g. diagnostic data or input/output data can be analysed.   Should the selected event occur, all relevant data are displayed along with it.

 COMSOFT GmbH | NetTEST II | July 2005 | Page 30 Are you interested in more information ? Then contact our French Distributor : RESoluCOM SARL 264 rue Jean Monnet EVREUX Tel: Fax: Web: Start