Technology & Engineering Division 1 DAQ for BNL 15 T Pulsed Magnet DATA ACQUISITION FOR PRE-OPERATIONAL TESTING OF BNL-E951 15T PUSLED MAGNET Chen-yu Gung.

Slides:



Advertisements
Similar presentations
Lecture 4: Signal Conditioning
Advertisements

Chapter 5 – Series dc Circuits
ECE 265 – LECTURE 14 Analog Signal Acquisition The A/D converters 5/14/ ECE265.
EML 2023 – Motor Control Lecture 4 – DAQ and Motor Controller.
Instrumentation - Introduction 10/9/2013Ohio University - Dr. Cyders1 Engineering measurements are usually taken by some form of transducer. A transducer.
Explain the introduction to ADC, ADC characteristics, Programming ADC using PIC18, Introduction to DAC and DAC interfacing with PIC18.
Data Acquisition Systems ACES Presentation Brad Ellison March 11, 2003.
Kirsten Hacker Triggering and Measurement Devices for LCLS 10/14/04 1 Triggering and Measurement Devices for the LCLS Undulator.
Interactive Engineering Workshop Eng. Mageda Al-Moubarak Eng. Fadia El-ssa.
Special Diodes. Describe and analyze the function and applications of:  Zener Diodes.
ESE Lab Computer based Temperature Control Sid Deliwala, ESE Labs.
ME 322: Instrumentation Lecture 19
Lecture – 7 Basic input and output
Chapter 5 – Series dc Circuits Introductory Circuit Analysis Robert L. Boylestad.
Linear Regulator Fundamentals 2.1 Types of Linear Regulators.
We are Group5 Weatherstation The team Members are : Saran Jackson Robert Howard Robert Garvey Gene Fitzgerald Steven Dowling.
PH4705/ET4305: A/D: Analogue to Digital Conversion Typical Devices: Data sheets are on the web site for A/D 8 bit parallel AD7819 and serial ADC0831 And.
Computer Based Data Acquisition Basics. Outline Basics of data acquisition Analog to Digital Conversion –Quantization –Aliasing.
Engineering 1040: Mechanisms & Electric Circuits Winter 2015 Analog & Digital Signals Analog to Digital Conversion (ADC)
DATA ACQUISITION Today’s Topics Define DAQ and DAQ systems Signals (digital and analogue types) Transducers Signal Conditioning - Importance of grounding.
Sensors and Electricity. What is a Sensor? A sensor is a device that: A sensor is a device that: 1) Measures a physical quantity 2) Converts this measurement.
Servo Motor Control Demonstration.
Servo Motor Control Demonstration. EML 2023 Department of Mechanical and Aerospace Engineering motor with gear reducer flex coupling incremental optical.
Electric Current Remember: Copper atoms are much bigger than electrons and are packed together in the wire October 2015.
HL-LHC/LARP, QXF Test Facility Workshop– R. Carcagno QXF Test Requirements Ruben Carcagno BNL Workshop December 17, 2013.
Instrumentation (AMME2700) 1 Instrumentation Dr. Xiaofeng Wu.
MERIT Hg System Final Design Review Hg Target System Controls V.B. Graves P.T. Spampinato T.A. Gabriel MERIT Collaboration Meeting MIT Plasma Science &
1 HD SIGNAL CONDITIONER SERIES POWER DISTRIBUTOR TRANSMITTER MODEL HD-IPC MODEL & SUFFIX CODE SELECTION HD-IPC MODEL ■ Input signal ■ Output1 signal ■
Circuit Theorems. Quiz 1. The source resistance from a 1.50 V D-cell is 1.5 . The voltage that appears across a 75  load will be a V b V.
Engineering Science EAB_S_127 Electricity Chapter 2.
Electronic Noise Noise phenomena Device noise models
1 HD SIGNAL CONDITIONER SERIES SAMPLE HOLD TRANSMITTER MODEL HD-SHC MODEL & SUFFIX CODE SELECTION HD-SHC MODEL ■ Output2 signal Availability as Output1.
RAL, 17-May-2007Vladimir Rajović / Birmingham MAPS TEST PCB SCHEMATICS REVIEW.
Lecture 4: Signal Conditioning
BME 353 – BIOMEDICAL MEASUREMENTS AND INSTRUMENTATION MEASUREMENT PRINCIPLES.
1 HD SIGNAL CONDITIONER SERIES LIMITER TRANSMITTER MODEL HD-LIM MODEL & SUFFIX CODE SELECTION HD-LIM MODEL ■ Output1 signal ■ Output2 signal Availability.
Engineering Science EAB_S_127 Electricity Chapter 3.
Voltage Divider Circuits Input transducers Input transducers are devices that convert a change in physical conditions (for example, temperature) into a.
Advances in High Current and Resistance Measurements to 11,000 Amps and Higher Guildline Instruments Limited.
Done by: Khalid Hijjawi Mohammad Massad.  Is an electrical instrument that measures electrical resistance, the opposition to an electric current. The.
Introduction and usage of Digital Multimeter for measurement of different electrical quantities such as voltage, current, resistance and diode.. By: Engr.Irshad.
Lecture Notes / PPT UNIT III
1 Summary Lecture: Part 1 Sensor Readout Electronics and Data Conversion Discovering Sensor Networks: Applications in Structural Health Monitoring.
TF Joint Testing Data Acquisition Special Test Equipment Hans Schneider with Robert Marsala (609) Engineering Operations April.
Zener Diode.
Analog dc ammeter اعداد فراس محمود الحجه عبد الرحمن علان.
Electrical Configuration and System Protection
MECH 373 Instrumentation and Measurements
SIGNAL CONDITIONING Signal conditioning is stage of instrumentation system used for modifying the transduced signal into a usable format for the final.
Intro to USB-6009 DAQ.
PULSE MODULATION.
(3) Signal Conditioning
ABB i-bus® EIB / KNX Analogue Input AE/S 4.2
ProtoDUNE SP – Slow control temperature readout setup test
EPFL-SPC, 5232 Villigen PSI, Switzerland
Operating a Amp – Volt – Ohm Meter
Chapter E –Transistors and H-Bridges
Potential Divider Aims What is a potential divider
HD SIGNAL CONDITIONER SERIES ISOLATED SIGNAL TRANSMITTER
Ohm’s Law The relationship between voltage, current and resistance is known as Ohm’s Law: V = IR Voltage (V) = Current (I) x Resistance (R) Volts.
Figure 12.2 The signal voltage from a throttle position increases as the throttle is opened because the wiper arm is closer to the 5-volt reference.
ADC and DAC Data Converter
Series 5300 Lithium Cell Formation System
Sensors EE 5351 Lecture 7.
724 Temperature Calibrator
Data Acquisition Electronics Unit – Lecture 6
Sensors ME 4135.
Types of Movement & Constructional Details
TOPIC- Load cell A load cell is a transducer that is used to create an electrical signal whose magnitude is directly proportional to the force being.
Presentation transcript:

Technology & Engineering Division 1 DAQ for BNL 15 T Pulsed Magnet DATA ACQUISITION FOR PRE-OPERATIONAL TESTING OF BNL-E951 15T PUSLED MAGNET Chen-yu Gung Mercury Target Collaboration Meeting MIT Plasma Science and Fusion Center October 17 – 19, 2005

Technology & Engineering Division 2 DAQ for BNL 15 T Pulsed Magnet Instrumentation and Signal Level Instrumentation NameNumber of Signals Signal Level Power Supply2 (V magnet & V shunt resistor ) 0 – 10 V AMI LN level sensor20 – 10 V CERNOX11Varies with temperature Discrete level sensor diode10Unknown Others, such as TC’s, Hall probe, etc. TBD

Technology & Engineering Division 3 DAQ for BNL 15 T Pulsed Magnet SIGNALS AND DATA ACQUISITION FOR PULSED MAGNET TEST

Technology & Engineering Division 4 DAQ for BNL 15 T Pulsed Magnet Data Acquisition System Use 2 National Instrument NB-MIO-16XL-18 in one Macintosh computer. DA is programmed in Labview. — Thing to do – modify existing program. Precision at 16 bit for bipolar DA between ± 10 V: ~ 0.3 mV. Maximum (damaging) input voltage: ± 35 V. Max. sampling rate for single channel DA: 55 Ksamples/sec. Max. sampling rate for multi-channel DA: 20 Ksamples/sec.

Technology & Engineering Division 5 DAQ for BNL 15 T Pulsed Magnet CERNOX Temperature Sensor Ref: Courts, S.S and Swinehart, P.R., ‘Stability of Cernox Resistance Temperature Sensors’, Adv. in Cryogenic Eng., Vol. 45, ~ 400 Ohm ~ 40 Ohm Typical resistances of CERNOX are between 40 Ohm and 400 Ohm at respective temperatures of 120 K and 80K. The sensor voltage signals are between 0.4 V and 4 V if an excitation of 10 mA is used.

Technology & Engineering Division 6 DAQ for BNL 15 T Pulsed Magnet Excitation Source for CERNOX Each current source will be used to drive 4-5 CERNOX’s connected in series with an excitation current set at 10 mA. Connections of the current leads will be made outside the magnet vessel. Four lead measurement will be used. The voltage leads will be tapped to the current leads outside the magnet vessel. The voltage drop along the lead wires needs be corrected. The same type of current source will be used to drive the discrete LN level sensor diodes. Connection: TBD. Lake Shore Model 120CS Current Source Output Current 1  A to 100 mA Accuracy0.1% on fixed ranges StabilityBetter than ± 0.01% Compliance Voltage11 Volts up to 50 mA

Technology & Engineering Division 7 DAQ for BNL 15 T Pulsed Magnet Data Acquisition During Cool-down and After Pulsing During cool-down and before pulsing the magnet, including purging out LN, record — LN level — Temperature — DAQ sampling interval: 2 minutes (tentative) After pulsing the magnet, record — Temperature — DAQ sampling interval: 30 seconds (tentative)

Technology & Engineering Division 8 DAQ for BNL 15 T Pulsed Magnet Data Acquisition During a Pulse (Optional) Will attempt to record the power supply voltage and current, and the temperature variation during a pulse. But, it is dictated by the inductive voltage picked up by the DAQ system (noise and voltage limit). Need ~ 13 channels.; zero LN level signals will not be recorded. A typical pulse duration is ~ 15 seconds. The sampling interval can be set to 5 ms.

Technology & Engineering Division 9 DAQ for BNL 15 T Pulsed Magnet Summary Record temperature and LN level signals with existing equipment before and after pulsing the magnet is straightforward. — TBD: Excitation and signal level of discrete level sensor diode. Recording temperature signal during a pulse (optional) is dictated by the inductive voltages picked up by the DAQ.