© H. Heck 2008Section 2.61 Module 2:Transmission Line Basics Topic 6:Measurement Equipment OGI EE564 Howard Heck.

Slides:



Advertisements
Similar presentations
Copyright 2001, Agrawal & BushnellVLSI Test: Lecture 181 Lecture 18 DSP-Based Analog Circuit Testing  Definitions  Unit Test Period (UTP)  Correlation.
Advertisements

Lecture 17: Analog to Digital Converters Lecturers: Professor John Devlin Mr Robert Ross.
Chapter 2Test Specification Process. n Device Specification Sheet – Purpose n Design Specification – Determine functionality of design n Test List Generation.
Multiplexed vs. Simultaneous Data Acquisition Using USB Devices Presented by: Rene Messier Company: Data Translation Company: Data Translation.
Module 5:. Advanced Transmission Lines Topic 5:
Lock-in amplifiers Signals and noise Frequency dependence of noise Low frequency ~ 1 / f –example: temperature (0.1 Hz), pressure.
Chi-Cheng Lin, Winona State University CS412 Introduction to Computer Networking & Telecommunication Theoretical Basis of Data Communication.
This lesson covers the following outcomes Unit 54 P1, P7, P8 Unit 6 P10, P11.
Lecture 9: D/A and A/D Converters
TRANSMISSION FUNDAMENTALS Review
© H. Heck 2008Section 2.51 Module 2:Transmission Line Basics Topic 5: Modeling & Simulation OGI ECE564 Howard Heck.
IT-101 Section 001 Lecture #8 Introduction to Information Technology.
Analogue to Digital Conversion
Storey: Electrical & Electronic Systems © Pearson Education Limited 2004 OHT 26.1 Data Acquisition and Conversion  Introduction  Sampling  Signal Reconstruction.
MICHAEL CHIANG EECS /05/2013 Presenting: Capacitors.
Module 2: Transmission Lines Topic 1: Theory
© H. Heck 2008Section 4.11 Module 4:Metrics & Methodology Topic 1: Synchronous Timing OGI EE564 Howard Heck.
Smith Chart.
Department of Electronic Engineering City University of Hong Kong EE3900 Computer Networks Data Transmission Slide 1 Continuous & Discrete Signals.
JF 12/04111 BSC Data Acquisition and Control Data Representation Computers use base 2, instead of base 10: Internally, information is represented by binary.
Fiber-Optic Communications
William Stallings Data and Computer Communications 7th Edition (Selected slides used for lectures at Bina Nusantara University) Data, Signal.
Module 3.0: Data Transmission
1 Lab Equipment. 2 TopicSlides DC Power Supply3-4 Digital Multimeter5-8 Function Generator9-12 Scope – basic controls13-20 Scope – cursors21-24 Scope.
EKT343 –Principle of Communication Engineering
© H. Heck 2008Section 4.31 Module 4:Metrics & Methodology Topic 3: Source Synchronous Timing OGI EE564 Howard Heck.
Harbin Institute of Technology (Weihai) 1 Chapter 2 Channel Measurement and simulation  2.1 Introduction  Experimental and simulation techniques  The.
The Oscilloscope: Basic Features & Functions  Source –Determines which signal is compared to the trigger settings.  Level –Determines where on the edge.
A Company Selling Technology and not just a Product.
Worst-Case Timing Jitter and Amplitude Noise in Differential Signaling Wei Yao, Yiyu Shi, Lei He, Sudhakar Pamarti, and Yu Hu Electrical Engineering Dept.,
The Oscilloscope shows voltage, Waveforms, & Phase shifts
1 High-Speed Digital Test & Measurement Chris Allen Course website URL people.eecs.ku.edu/~callen/713/EECS713.htm.
October 10, USB 2.0 Test Modes and Their Application Jon Lueker Intel Corporation.
May 16, USB 2.0 Test Modes and Their Application Jon Lueker Intel Corporation.
Numerical algorithms for power system protection Prof. dr. sc. Ante Marušić, doc. dr. sc. Juraj Havelka University of Zagreb Faculty of Electrical Engineering.
Lecture 1 Signals in the Time and Frequency Domains
Module 4: Metrics & Methodology Topic 2: Signal Quality
Technion – Israel Institute of Technology Department of Electrical Engineering Winter 2009 Instructor Amit Berman Students Evgeny Hahamovich Yaakov Aharon.
© H. Heck 2008Section 2.41 Module 2:Transmission Lines Topic 4: Parasitic Discontinuities OGI EE564 Howard Heck.
© H. Heck 2008Section 4.41 Module 4:Metrics & Methodology Topic 4: Recovered Clock Timing OGI EE564 Howard Heck.
Module 5: Advanced Transmission Lines Topic 3: Crosstalk
© H. Heck 2008Section 6.11 Module 6:Advanced Issues Topic 1:Projections, Limits, Barriers OGI EE564 Howard Heck.
1HSSPG Georgia Tech High Speed Image Acquisition System for Focal-Plane-Arrays Doctoral Dissertation Presentation by Youngjoong Joo School of Electrical.
© H. Heck 2008Section 1.11 Module 1Introduction Topic 1Overview OGI EE564 Howard Heck I1I1 V1V1 I2I2 V2V2 dz.
© H. Heck 2008Section 5.41 Module 5:Advanced Transmission Lines Topic 4: Frequency Domain Analysis OGI ECE564 Howard Heck.
© H. Heck 2008Section 2.31 Module 2:Transmission Lines Topic 3: Reflections OGI ECE564 Howard Heck.
Transmission Line “Definition” General transmission line: a closed system in which power is transmitted from a source to a destination Our class: only.
TDS8000 and TDR Considerations to Help Solve Signal Integrity Issues.
© H. Heck 2008Section 3.21 Module 3:Analysis Techniques Topic 2: Bergeron Diagrams OGI EE564 Howard Heck.
ECE 4710: Lecture #6 1 Bandlimited Signals  Bandlimited waveforms have non-zero spectral components only within a finite frequency range  Waveform is.
EEE2243 Digital System Design Chapter 7: Advanced Design Considerations by Muhazam Mustapha, extracted from Intel Training Slides, April 2012.
An Unobtrusive Debugging Methodology for Actel AX and RTAX-S FPGAs Jonathan Alexander Applications Consulting Manager Actel Corporation MAPLD 2004.
© H. Heck 2008Section 2.71 Module 2:Measurement Topic 7:Time Domain Reflectometry OGI EE564 Howard Heck.
© H. Heck 2008Section 3.11 Module 3:Analysis Techniques Topic 1: Lattice Diagrams OGI EE564 Howard Heck.
The Probe: Measurement Accuracy Begins at the Tip  Attenuation –The ratio of the probe’s input signal amplitude to the output signal amplitude..  Bandwidth.
© H. Heck 2008Section 5.21 Module 5:Advanced Transmission Lines Topic 2: Intersymbol Interference OGI EE564 Howard Heck.
The Interconnect Modeling Company™ High-Speed Interconnect Measurements and Modeling Dima Smolyansky TDA Systems, Inc.
ECE 4371, Fall, 2015 Introduction to Telecommunication Engineering/Telecommunication Laboratory Zhu Han Department of Electrical and Computer Engineering.
Digital to Analog Converter (DAC)
Interconnect II – Class 17
EKT 314/4 WEEK 5 : CHAPTER 3 SIGNAL CONDITIONING ELECTRONIC INSTRUMENTATION.
1 John McCloskey NASA/GSFC Chief EMC Engineer Code 565 Building 23, room E Fundamentals of EMC Transmission Lines.
A function generator is usually a piece of electronic test equipment or software used to generate different types of electrical waveforms over a wide.
Digitization at Feed Through R&D (2) Digitizer Performance Evaluation Student: John Odeghe ; SC State, Fermi Lab Intern Supervisor: JinYuan Wu; Fermi Lab.
FUNCTION GENERATOR.
The Search for Accurate CDM Waveforms
An Unobtrusive Debugging Methodology for Actel AX and RTAX-S FPGAs
High Speed Signal Integrity Analysis
Aliasing and Anti-aliasing Filters TIPL 4304 TI Precision Labs – ADCs
Analog and Digital Instruments
Presentation transcript:

© H. Heck 2008Section 2.61 Module 2:Transmission Line Basics Topic 6:Measurement Equipment OGI EE564 Howard Heck

Measurement Equipment EE 564 © H. Heck 2008 Section 2.62 Where Are We? 1.Introduction 2.Transmission Line Basics 1.Transmission Line Theory 2.Basic I/O Circuits 3.Reflections 4.Parasitic Discontinuities 5.Modeling, Simulation, & Spice 6.Measurement: Basic Equipment 7.Measurement: Time Domain Reflectometry 3.Analysis Tools 4.Metrics & Methodology 5.Advanced Transmission Lines 6.Multi-Gb/s Signaling 7.Special Topics

Measurement Equipment EE 564 © H. Heck 2008 Section 2.63 Contents Why Measure? Basic Measurement Equipment List Pulse Generators Oscilloscopes  Bandwidth  Sampling & Nyquist’s Theorem Probes:  Bandwidth  Loading  Attenuation  Types  Grounding System Validation & Margin Testing Summary References

Measurement Equipment EE 564 © H. Heck 2008 Section 2.64 Why Measure? How do we prove to ourselves that our design works?  We simulate the design, but simulators have limitations.  Our models may not be accurate (garbage in, garbage out). Measurement gives us confidence in our design.  By determining system margin (timing, noise). Measure under environmental conditions (temperature, voltage, etc.), and vary reference and termination voltages. Limitation: can’t measure worst case extremes.  By characterizing the pieces of the system – I/O buffers, packages, PCBs, connectors, etc. Build confidence in our models by correlating to measurement. Use the models to extrapolate behavior to worst case conditions (or to project defect rates, i.e. statistical design). Another reason to measure: debug.  May be necessary to find errors in protocol or with I/O circuits.  Measurement is the only way to prove to someone else that your design is NOT the cause when a problem exists.

Measurement Equipment EE 564 © H. Heck 2008 Section 2.65 Equipment Needs Equipment list for a modern signal integrity lab: High speed digitizing oscilloscope with pulse generator  Measure system signals & use for TDR (time domain reflectometry) and TDT (time domain transmission) High performance probes Calibration standards Vector Network Analyzer (VNA)

Measurement Equipment EE 564 © H. Heck 2008 Section 2.66 Pulse Generator Function: generate waveforms for characterizing our design. Allows control over:  Wave shape (sine, ramp, arbitrary)  Rise time  Output voltage  Bit pattern Example: Tektronics AWG 610 Arbitrary Waveform Generator

Measurement Equipment EE 564 © H. Heck 2008 Section 2.67 Oscilloscopes Function: capture signals for viewing and analysis. Key Parameters: Bandwidth & Sampling Rate If your scope has inadequate bandwidth, high frequency components of the signal being measured will be filtered out, and key timing and/or noise information may be inaccurate. If your scope has inadequate sampling rate, edges cannot be located precisely enough and high frequency noise components will be missed.

Measurement Equipment EE 564 © H. Heck 2008 Section 2.68 Oscilloscope Bandwidth Rule of Thumb: The minimum scope bandwidth should be at least 5 times the highest frequency component being sampled. [2.6.1] [2.6.2] In general, the greater the scope bandwidth, the smaller the errors in measuring time intervals. Rule of thumb: scope rise time should be < 1/3 of the time interval to be measured. Input Pulse Waveform seen on oscilloscope

Measurement Equipment EE 564 © H. Heck 2008 Section 2.69 Oscilloscope Bandwidth Example A 17.5 ps signal edge measured with… 700 MHz scope 2 GHz scope 1 GHz scope Insufficient bandwidth degrades the measured rise time and filters out noise.

Measurement Equipment EE 564 © H. Heck 2008 Section Oscilloscope Sampling – Types of Sampling Real Time: “Single shot”, on the fly acquisition. All data acquired in one cycle After many samples, scope reconstructs signal. Requires repetitive signal. Sequential: One sample digitized per trigger. Each successive trigger delays sampling further. Random Repetitive: Signal is constantly sampled & digitized at rate determined by scope’s sample rate. Requires repetitive signal.

Measurement Equipment EE 564 © H. Heck 2008 Section Oscilloscope Sampling Rate Affect on timing measurements: Higher: good characterization of edge. Too Low: edge cannot be located precisely. Glitch detection: Higher: better chance of detection. Too Low: can miss glitch.

Measurement Equipment EE 564 © H. Heck 2008 Section Sampling Rate: Nyquist’s Theorem Nyquist’s Theorem: If a signal is sampled at a frequency 2 f, there is no information in the samples about the components of the signal at frequencies above f. The effect on time domain measurement uncertainty of a sample rate 2 f is equivalent to a band-limiting filter with a sharp cut-off at frequency = f. Nyquist’s Theorem provides an upper limit. In practice the sampling rate should be higher.

Measurement Equipment EE 564 © H. Heck 2008 Section Sampling Rate: Nyquist’s Theorem As the sampling rate nears the Nyquist limit, the measurement depends strongly on the signal reconstruction algorithm and where the signal is sampled. 1/10f Rule of thumb: sampling rate  10 f max. 1/2f 1/f

Measurement Equipment EE 564 © H. Heck 2008 Section Probes: Bandwidth Probe bandwidth is the maximum –3dB frequency a user can expect with a scope/probe system, where. [2.6.3]

Measurement Equipment EE 564 © H. Heck 2008 Section Probes: Loading Input resistance and capacitance determine the loading effect of a probe. Probe loading is frequency dependent.  At DC and low frequencies, resistive loading is most important.  As f increases ( t r  ), capacitive loading becomes dominant.

Measurement Equipment EE 564 © H. Heck 2008 Section Probes: Loading #2 Loading causes probes to affect the measured rise time and delay. The time required to charge the capacitance from 10% to 90% of the signal level is [2.6.4] Probe w/ highest impedance (lowest C probe ) gives the least circuit loading.

Measurement Equipment EE 564 © H. Heck 2008 Section Probes: Loading #3 Which we can use to determine the actual signal rise time: [2.6.5] [2.6.6] Probe rise time is determined when the probe is driven from a terminated 50  source. Use it to calculate the rise time of the probe/scope system:

Measurement Equipment EE 564 © H. Heck 2008 Section Probes: Attenuation Attenuation = ratio of output signal to input signal. Goal is to maintain constant attenuation over a wide range of frequencies, limiting it to 3dB as the frequency increases to the rated bandwidth. [2.6.7]

Measurement Equipment EE 564 © H. Heck 2008 Section Probe Types: Hand Held Easiest, most common. Use for quick checks. Lacking for accuracy & repeatability. Common problem: large ground loops.

Measurement Equipment EE 564 © H. Heck 2008 Section Probe Types: SMA Connectors Better repeatability than handheld. Adds cost due to soldering of SMA. Still adds noticeable discontinuity at fast edge rates.

Measurement Equipment EE 564 © H. Heck 2008 Section Probe Types: Microprobes Most accurate – the only one suitable for measuring small variations. Expensive & time consuming to use.

Measurement Equipment EE 564 © H. Heck 2008 Section Probe Types: Signal Quality & Edge Rate Effects Ringing: SMA vs. Handheld Edge Rate: SMA vs. Microprobe

Measurement Equipment EE 564 © H. Heck 2008 Section Probe Selection Guidelines Be sure the probe will match the input resistance and capacitance of the scope being used.  i.e. 50  scope inputs require 50  probes. Select a probe with adequate rise time and bandwidth for the oscilloscope and DUT. Minimize probe loading effects by selecting low impedance test points. Remember that probe impedance varies inversely with frequency.  e.g. probe with 50 MHz bandwidth and Z i = 10 M  at DC has a Z i = 1.5 k  at 50 MHz.  Choose a probe with lowest possible C i and highest R i for best overall signal fidelity.

Measurement Equipment EE 564 © H. Heck 2008 Section Probe Grounding Inductance in the ground leads causes ringing: [2.6.7] Signal GND PCB Signal GND PCB Large Ground Loop SmallGroundLoop

Measurement Equipment EE 564 © H. Heck 2008 Section System Validation & Margin Testing Use oscilloscope & probes to measure signals in your design. Probe clock and data to measure setup and hold margin.  Under extreme temperature and voltage.  With “skewed” hardware: e.g. slow/fast Si process, low/high Z 0 PCB.  For selected signals: e.g. worst case lengths and/or spacing. Characterize noise margins by varying R TT and/or V REF. Sometimes we can vary line lengths to find out where the system fails.  e.g. Pentium® II Processor FSB with “riser cards” of various lengths.

Measurement Equipment EE 564 © H. Heck 2008 Section Summary Measurements are necessary to prove that your design works and are required to build and correlate accurate models. Bandwidth and sampling rate are the key metrics for characterizing oscilloscope performance. Probes have strong impacts on measurement accuracy. Bandwidth, loading, and attenuation are key parameters for describing probe performance. Probing techniques (handheld, SMA, microprobe, as well as ground loops) also have strong influence on the fidelity of measurements.

Measurement Equipment EE 564 © H. Heck 2008 Section References General S. Hall, G. Hall, and J. McCall, High Speed Digital System Design, John Wiley & Sons, Inc. (Wiley Interscience), 2000, 1 st edition. W. Dally and J. Poulton, Digital Systems Engineering, Chapters 4.3 & 11, Cambridge University Press, H. Johnson and M. Graham, High Speed Digital Design: A Handbook of Black Magic, PTR Prentice Hall, R. Poon, Computer Circuits Electrical Design, Prentice Hall, 1 st edition, 1995.

Measurement Equipment EE 564 © H. Heck 2008 Section References Oscilloscopes Tektronix, Inc., “Effects of Bandwidth on Transient Information,” Application Note 55W , April Tektronix, Inc., “Sampling Oscilloscope Techniques,” Application Note 47W , October Hewlett Packard Corp., “Bandwidth and Sampling Rate in Digitizing Oscilloscopes,” Application Note 344, April Lecroy, “DSO Applications in High Speed Electronics,” Lecroy, “Troubleshooting High-Speed Digital Signals with DSOs,” Lecroy, “Debug and Characterization of High-Speed Digital Electronics,” sp. sp

Measurement Equipment EE 564 © H. Heck 2008 Section References Probes Tektronix, Inc., “High Speed Probing,” Application Note 55W , June Tektronix, Inc., “Primer: ABCs of Probes,” Application Note 60W , July Lecroy, “Probes and Probing,” Cascade Microtech, “High Speed Digital Microprobing: Principles and Applications,” Application Note HSDM-391, Cascade Microtech, “Microprobing with the HP 5412T Oscilloscope,” D. Carlton, et. al., “Accurate Measurement of High-Speed Package and Interconnect Parasitics,” Journal of Microwave Technology, July 1988, pp