PREVENTION, CONTROL AND/OR EXTINGUISHMENT OF COAL SEAM FIRES USING CELLULAR GROUT LAKEWOOD, COLORADO
GOODSON CELLULAR CONCRETE PRODUCTS Thermocell Foamcell Permacell Flowcell
THERMOCELL CHARACTERISTICS Environmentally Safe High Heat/Shock Resistant Low Thermal Conductivity Pumpable/Self Leveling Waste Fly Ash Up to 90%
COAL FIRE PREVENTION Underground –Entryway/Ventilation Seals –Closure Seals on Adits and Shafts Strip Pits Spray Seam During Mining –Spray All Exposed Seams at Pit Completion
BASIC FIRE CONTROL Grout Surface Features –Seal Exposed Fire Areas –Seal Cracks/Crevasses –Seal Mine Openings – Adits/Shafts Construct Incombustible Seal
ADVANCED FIRE CONTROL Basic Control Exploratory Drilling/Thermocouples Isolation Trenches and Barriers Construct Incombustible Seal Monitoring
FIRE EXTINGUISHMENT Advanced Control Direct Drill/Grout into Fire Areas Potential Isolation Barriers Monitoring of Cooling Stage
COST FACTORS/EQUIPMENT Location Material Availability Size/Depth of Fire Portable Equipment
WEBSITE Goodson & Associates, Inc West Colfax Avenue Lakewood, Colorado Office: (303) Fax: (303)