Development of Surface EMG Sensor Network and its Application System GRRC Int. Workshop 2008 Youngjin Choi Hanyang University.

Slides:



Advertisements
Similar presentations
BIOPOTENTIAL AMPLIFIERS
Advertisements

Sensors Interfacing.
EMG Lab Data Collection Toru Tanaka, Miguel Narvaez, Adam Bruenger, and members of the Spring Semester KIN 831 Course.
1 Electrical and Computer Engineering Team E-μ Advised by Professor Baird Soules Midway Design Review – November 2014.
Announcements Assignment 8 posted –Due Friday Dec 2 nd. A bit longer than others. Project progress? Dates –Thursday 12/1 review lecture –Tuesday 12/6 project.
Prof. Anthony Petrella Musculoskeletal Modeling & Inverse Dynamics MEGN 536 – Computational Biomechanics.
Digital Signal Processing (DSP) Fundamentals. Overview What is DSP? Converting Analog into Digital –Electronically –Computationally How Does It Work?
Department of Computer Science San Diego State University
Vital Signs Monitor UConn BME 4900 Vital Signs Monitor Purpose As the population ages, many people are required by their doctors to take vital signs.
Why prefer CMOS over CCD? CMOS detector is radiation resistant Fast switching cycle Low power dissipation Light weight with high device density Issues:
Guitar Effects Processor Critical Design Review October, 07, 2003 Groups Members: Adam Bernstein Hosam Ghaith Jasenko Alagic Matthew Iyer Yousef Alyousef.
EE 198 B Senior Design Project. Spectrum Analyzer.
DESIGN OF WIRELESS PROSTHETIC HAND.  Introduction  Why Wireless robotic arm  System Description  Block Diagram  System Operation  Conclusion  References.
TECHNOLOGY DEMONSTRATOR OF 7-CHANNEL DIGITAL FLIGHT DATA RECORDER AS AVIONICS TEACHING AID USING STATIC MODEL AIRCRAFT Authors 1. Wg Cdr Nikhil Verma,
Some Test Result about Current Sensor
Numerical algorithms for power system protection Prof. dr. sc. Ante Marušić, doc. dr. sc. Juraj Havelka University of Zagreb Faculty of Electrical Engineering.
© The McGraw-Hill Companies, Inc McGraw-Hill 1 PRINCIPLES AND APPLICATIONS OF ELECTRICAL ENGINEERING THIRD EDITION G I O R G I O R I Z Z O N I 15.
Background   Who does this project addresses to?   Handicapped.   Amputated limbs.   Paralyzed.   Motivation Statistics.
Chapter 19 Electronics Fundamentals Circuits, Devices and Applications - Floyd © Copyright 2007 Prentice-Hall Chapter 19.
ELECTROMYOGRAM Amit Sethi Pre-doc Rehab Sciences, MS OTR/L.
IIT Bombay AIM , IIT Bombay, 27 June ’03 1 Online Monitoring of Dissipation Factor Dayashankar Dubey (MTech) Suhas P. Solanki,
ACOE2551 Microprocessors Data Converters Analog to Digital Converters (ADC) –Convert an analog quantity (voltage, current) into a digital code Digital.
By Grégory Brillant Background calibration techniques for multistage pipelined ADCs with digital redundancy.
Analog to Digital conversion. Introduction  The process of converting an analog signal into an equivalent digital signal is known as Analog to Digital.
Module 4 Operational Amplifier
Biomedical Instrumentation I
Beam phase and intensity measurement Grzegorz Kasprowicz Richard Jacobsson.
Vital Signs Monitor UConn BME 4900 Vital Signs Monitor Purpose As the population ages, many people are required by their doctors to take vital signs.
Eeng Chapter 4 Bandpass Circuits   Limiters   Mixers, Upconverters and Downconverters   Detectors, Envelope Detector, Product Detector  
Moulali.P Central Scientific Instruments Organization (CSIO), Council for Scientific and Industrial Research (CSIR), Chandigarh, India.
ECG Monitor Objective o Provide users an economical ECG monitoring device o Raise awareness to the importance of a healthy heart and living o Allow doctors.
Investigation for Various ECG Acquisitions Prepared by Dr. Syed Sahal Nazli Alhady Dr. Harsa Amylia bt. Mat Sakim School of Electrical & Electronic Engineering.
What is an Amplifier…? An Amplifier is a device which takes small voltage at the input, amplifies it and produce higher voltage at the output. The gain.
Mixed Signal Chip Design Lab Cubic Function Generator Design Boram Lee, Jaehyun Lim Department of Computer Science and Engineering The Pennsylvania State.
CARE / ELAN / EUROTeV Feedback Loop on a large scale quadrupole prototype Laurent Brunetti* Jacques Lottin**
Introduction to MicroElectronics
Design of Electrocardiogram (ECG) System
PREPARED BY V.SANDHIYA LECT/ ECE UNIT- 3 APPLICATIONS OF OP-AMP 1.
IEEE JOURNAL OF SOLID-STATE CIRCUITS, VOL. 50, NO. 3, MARCH 2015 Woojae Lee, Member, IEEE, and SeongHwan Cho, Senior Member, IEEE Chairman: Dr.Shih-Chung.
Non-invasive fetal electrocardiogram measurements Adviser :蔡亮宙 Student ;蔡政宏.
Chapter 8 Operational Amplifiers Tai-Cheng Lee Electrical Engineering/GIEE 1.
Signal Analyzers. Introduction In the first 14 chapters we discussed measurement techniques in the time domain, that is, measurement of parameters that.
Portable Real Time ECG Design
PROSTHETIC LEG PRESENTED BY:-AWAIS IJAZ HASNAT AHMED KHAN.
Variable-Frequency Response Analysis Network performance as function of frequency. Transfer function Sinusoidal Frequency Analysis Bode plots to display.
ASIC Development for Vertex Detector ’07 6/14 Y. Takubo (Tohoku university)
Guide Presented by Mr.M Cheenya V.Abhinav Kumar 11E31A0422 Asst.Professor K.Shiva Kumar 11E31A0423 K.Rajashekhar 11E31A0424 K.Chaithanya Sree 11E31A0428.
1. 2 The electrocardiograph (ECG) is an instrument, which records the electrical activity of the heart. Electrical signal from the heart characteristically.
Sampling. Introduction  Sampling refers to the process of converting a continuous, analog signal to discrete digital numbers.
The Equations of Motion Euler angle rate equations:
Microprocessors Data Converters Analog to Digital Converters (ADC)
Physiologic signals Lecture (2).
SIGNAL CONDITIONING Signal conditioning is stage of instrumentation system used for modifying the transduced signal into a usable format for the final.
Quiz: Calculating the total noise for ADC systems TIPL 4204 TI Precision Labs – ADCs Created by Art Kay.
EMG-HUMAN MACHINE INTERFACE SYSTEM
Operational Amplifier
Motion control of a robotic prosthetics with skin surface EMG signals Md Assad-Uz-Zaman, Md Rasedul Islam, Brahim Brahmi1, Miguel Garcia, Mohammad.
Optical PLL for homodyne detection
Data Acquisition System
KRB proposal (Read Board of Kyiv group)
FINAL YEAR PROJECT 1 WPB49804 Development of arm gesture device
EPS Sensors & Hand Tracking/Gesture Recognition
Hyonyoung Han, Min-Joon Kim, and Jung Kim
Lesson 8: Analog Signal Conversion
Amplifiers: A Bio amplifier is an electrophysiological device, a variation of the instrumentation amplifier, used to gather and increase the signal integrity.
Electrical traditional Chinese Instrument - Xun
MagneticSystem Using Discretize Low Pass Filter
EMG activity analysis in performing activity of daily living
Dayashankar Dubey (MTech)
Portable Digital Blood Pressure Monitor
Presentation transcript:

Development of Surface EMG Sensor Network and its Application System GRRC Int. Workshop 2008 Youngjin Choi Hanyang University

Contents Introduction Development of EMG Sensor Arm Motion Tracking Algorithm Experimental Results Conclusion Future Works

What is EMG EMG(ElectroMyoGram) EMG(ElectroMyoGram) - is one of various bioelectrical signals generated from the human body such as ECG, EEG, EOG, ENG. - has been actively studied for the human muscle analysis, motion imitation, etc. - is one of the best basis signals to develop the bio-mechanical system by transferring the robotics technologies to the rehabilitation engineering Application research filed Application research filed - diagnosis in the medical science - sports science - rehabilitation engineering

Literature Surveys Existing studies about the EMG Existing studies about the EMG - using the learning method (D. Nishikawa, “EMG Prosthetic Hand Controller Using Real-Time Learning Method”) - using the AR model (J. Zhao, “ Levenberg-MarQuardt based neural network control for a five-fingered prosthetic hand”) - using the Hill model (E. Cavallaro, “Hill-based model as a myoprocessor for a neural controlled powered exoskeleton arm-parameters optimization”) - using the pattern recognition for the motion generation of real hand (Y. Su,“Towards and EMG-Controlled Prosthetic Hand Using a 3-D Electromagnetic Positioning System”) - using the ARMAX model for the tele-operation (P. K. Artemiadis, “EMG-based Teleoperation of a Robot Arm in Planar Catching Movements using ARMAX Model and Trajectory Monitoring Techniques”)

Development of EMG Sensor I Signal Input 1000 times Amplifier High Pass Filter for DC voltage rejection Low Pass Filter for noise rejection Voltage Adder for AD conversion Analog Switch for op-amp drift prevention - Circuit design for signal acquisition

Development of EMG Sensor II Characteristics -4 Channel EMG Measurement -Fast Microprocessor -150M[Hz] -High Resolution -12bit ADC -EMG Sensor Network

Surface-EMG Waveforms The electrodes are for the acquisition of biceps and deltoideus EMG muscle signals. The biceps muscle signal is used for the elbow joint angle extraction. The deltoideus muscle signal is used for the shoulder forward directional angle extraction The maximum amplitude level is about 300[uV]. The EMG signals are amplified by about 1000 times for the signal processing.

Range of Motion (ROM) Biceps brachiiBiceps brachii ROM of an elbow jointROM of an elbow joint 0~145 degrees0~145 degrees DeltoideusDeltoideus ROM of a shoulder jointROM of a shoulder joint 0~180 degrees0~180 degrees

Motion Tracking Algorithm I Taking RMS values Taking RMS values - take the RMS value for EMG[k] grouped by 64 samples

Motion Tracking Algorithm II Taking LPF Taking LPF - filter out the signal by using the 1[Hz] low-pass filter

Motion Tracking Algorithm III Scaling function Scaling function -LPF signals are not proportional to the flexion and extension angles of elbow and shoulder joints -So, we make use of the curve-fitting method -For this, we assume the 3 rd order scaling function for 4-point curve-fitting

Motion Tracking Algorithm IV  Pre-angle Process - Taking RMS - Taking LPF - Applying scaling function

Motion Tracking Algorithm V Optimization ProcessOptimization Process Finally, the recursive-least-squares method is applied to the pre-angle for self-adaptation In this case, the tap-weights are adjusted by itself during the optimization procedures.

Coupling Effect b/w Biceps and Deltoideus -Though the signal measured at a deltoideus muscle must be dominant for the shoulder joint motion, the sEMG signal measured from the biceps brachii has the coupling effect with the shoulder motion -So, we remedy the equation by subtracting the Deltoideus from Biceps brachii Biceps brachii sEMG Deltoideus sEMG

Block Diagram of Entire Algorithm

Experimental Results

Experimental Video The initialization procedure is firstly performed. At the specific joint angles measured from inclinometer, we measure the EMG signal values for the biceps and deltoideus muscles, respectively. Then, we can get the scaling function for elbow joint and shoulder joint angle calculations. And then, we perform the real-time motion tracking simulation. As we can see the video, the experimental results show the real-time good tracking performance for human arm motion.

Concluding Remarks We have developed EMG measurement sensorWe have developed EMG measurement sensor We have suggested the real-time motion tracking algorithm based on the surface EMG signal processingWe have suggested the real-time motion tracking algorithm based on the surface EMG signal processing We have showed the validity of the suggested algorithm through the experimentsWe have showed the validity of the suggested algorithm through the experiments

Future Works EMG sensor networking Applications ▫Master (human) arm device for tele-operation ▫Prosthetic arm for an amputee

Thank you Question :