RTF Management Updates Jennifer Anziano Regional Technical Forum September 22, 2015.

Slides:



Advertisements
Similar presentations
Residential LED UES Measure Update Regional Technical Forum August 20, 2013.
Advertisements

Ductless Heat Pumps in Manufactured Homes with Zonal Electric Resistance Heat Adam Hadley Regional Technical Forum February 18, 2015.
Oregon Energy Star Homes Measure Update New Measure Proposal April 22nd,
SEEM Calibration for Multi-Family Buildings Regional Technical Forum September 18, 2012 Analysis Performed By Ben Larson, Jon Heller, Henry Odum, and Carmen.
UES Measure Sunsets Regional Technical Forum December 17, 2013.
Deeming Savings for Ductless Heat Pumps in Manufactured Homes Regional Technical Forum January 4 th, 2011.
Grocery Measure: LEDs for Reach-In Display Cases Regional Technical Forum July 21 st, 2015 Mohit Singh-Chhabra.
Prescriptive Duct Sealing UES Measure Proposal Regional Technical Forum Subcommittee July 8, 2013.
Thermostatic Shower Restriction Valve UES Measure Ryan Firestone Regional Technical Forum 7/21/2015.
Research Strategy Review: Heat Pump Water Heaters Thermostatic Restriction Valves Jennifer Anziano RTF R&E Subcommittee July 8, 2015.
Residential New Construction Montana House: UES Measure Update Adam Hadley Regional Technical Forum April 14, 2015.
Implementer’s Group April 2015 Meeting Debrief and Upcoming Meeting Prep April 24, 2015.
Direction on Guidelines Savings Definition Path: CONTINUED Remaining Useful Life (RUL) and Measure Interaction Regional Technical Forum February 19, 2014.
New Measure Proposal Review and Prioritization Jennifer Anziano, Adam Hadley, Mohit Singh-Chhabra, Christian Douglass Regional Technical Forum February.
Implementer’s Group January Meeting Debrief and Upcoming Meeting Prep January 29, 2015.
Prescriptive Duct Sealing in Manufactured Homes: Proposal for Proven UES Adam Hadley Regional Technical Forum August 18, 2015.
RTF 2015 Mid-Year Progress Report and 2016 Work Plan Jennifer Anziano Regional Technical Forum July 21, 2015.
Residential Single Family HVAC UES Measures Proven and Planning UES Measure Proposals Adam Hadley Regional Technical Forum December 16, 2014.
Residential Weatherization and Ventilation Subcommittee Presentation to the Regional Technical Forum August 30, 2011.
RTF Staff, Subcommittee and Work Updates October 23, 2012.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum June.
RTF Work Plan Mid-Year Re-Programming July 15, 2014.
Delivery Verification Jennifer Anziano Regional Technical Forum March 17, 2015.
Sunset Date Extension Requests Jennifer Anziano Regional Technical Forum August 18, 2015.
Washington Energy Star and Built Green Homes Measure Update New Measure Proposal August 12th,
RTF Management Update Jennifer Anziano Regional Technical Forum April 14, 2015.
Oregon ENERGY STAR Homes Measure Update Adam Hadley Regional Technical Forum March 17, 2015.
Heat Pump Water Heater Request for Feedback on a proposal to add UES measures with a “Retail – any installation location” delivery mechanism Regional Technical.
Implementer’s Group February 2015 Meeting Debrief and Upcoming Meeting Prep February 26, 2015.
RTF Management Update Jennifer Anziano Regional Technical Forum May 12, 2015.
RTF Delivery Verification Guidance Batch 1 Jennifer Anziano Regional Technical Forum May 12, 2015.
Path for Multi-Family (MF) Weatherization and NC Measures Christian Douglass 8/18/2015.
RTF Small / Rural Subcommittee Tuesday, June 11, 9am – 10:30am.
Northwest Power and Conservation Council Residential Conservation Resource Assessment Overview of Analytical Process and Major Assumptions April 21, 2009.
Research Strategy Review: Advanced Power Strips MH HVAC Related Measures Jennifer Anziano RTF R&E Subcommittee August 6, 2015.
Implementer’s Group July 2015 RTF Meeting Debrief and Upcoming Meeting Prep July 29, 2015.
Implementer’s Group June 2015 RTF Meeting Debrief and Upcoming Meeting Prep June 23, 2015.
RTF Management Update Jennifer Anziano Regional Technical Forum February 18, 2015.
SEEM Calibration for Multi-Family Buildings Regional Technical Forum September 18, 2012 Analysis Performed By Ben Larson, Jon Heller, Henry Odum, and Carmen.
Residential New SF Energy Star Homes Idaho and Montana UES Measure Updates: Energy Star Homes, DHP TCO Homes, and BOP2 Homes March 18 th, 2014.
Residential New SF Energy Star Homes UES Measure Update December 17th, 2013.
Implementer’s Group May 2015 Meeting Debrief and Upcoming Meeting Prep May 19, 2015.
1 Proposed Changes to the RTF’s Heat Pump Deemed Savings and Cost- Effectiveness Draft 6th Plan Assumptions April 7, 2009.
RTF Residential Lighting Subcommittee Tuesday, March 4, 11am – 12:30pm 1.
RTF Management Updates Jennifer Anziano Regional Technical Forum October 20, 2015.
BPA Impact Evaluation Policies QSSI. 2 Drivers: Industry Best practice, Power Act, RTF Guidelines, confidence savings.
Working Towards Better Savings Estimates for HVAC and Weatherization Measures Regional Technical Forum September 16, 2014.
ENERGY STAR and Eco-Rated Homes: Planning Estimates and Research Strategy Regional Technical Forum December 8 th, 2015 Josh Rushton & Mohit Singh-Chhabra.
Residential LED Fixtures Research Discussion Research and Evaluation Subcommittee January 8, 2016.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum December.
RTF Management Update Jennifer Anziano Regional Technical Forum August 18, 2015.
Residential Showerheads UES Update Ryan Firestone Regional Technical Forum October 20, 2015.
RTF Management Updates Jennifer Light Regional Technical Forum December 8, 2015.
RTF Delivery Verification Guidance Batch 2 Jennifer Anziano Regional Technical Forum September 22, 2015.
Idaho and Montana Residential Single Family New Construction Measures Mohit Singh-Chhabra Regional Technical Forum October 20 th, 2015.
RTF Management Update Jennifer Anziano Regional Technical Forum June 16, 2015.
RTF Management Updates Jennifer Light Regional Technical Forum January 21, 2016.
Prescriptive Duct Sealing in Manufactured Homes: Proposal for Proven UES Adam Hadley Regional Technical Forum August 18, 2015.
Planning UES Measures: Prescriptive Duct Sealing SF Performance-based Duct Sealing SF Performance-based Duct Sealing MH Adam Hadley & Josh Rushton Regional.
RTF Management Update Jennifer Anziano Regional Technical Forum July 21, 2015.
Exterior LED Area Lights
Implementer’s Group December Meeting Debrief and Upcoming Meeting Prep January 6, 2015.
RTF Management Update Jennifer Anziano Regional Technical Forum March 17, 2015.
Implementer’s Group October 2015 RTF Meeting Debrief and Upcoming Meeting Prep October 29, 2015.
RTF Management Updates Jennifer Light Regional Technical Forum February 17, 2016.
RTF’s Engagement with Research Jennifer Light RTF Policy Advisory Committee February 19, 2016.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat UES Measure Update Regional Technical Forum June 17, 2014.
Proven UES: Residential Dishwasher Proposal to Deactivate Jennifer Anziano Regional Technical Forum November 10, 2015.
Manufactured Homes: Heat Pump Related Measures Regional Technical Forum Presentation August 18 th, 2015.
Working Towards Better Savings Estimates for HVAC and Weatherization Measures Regional Technical Forum September 16, 2014.
Presentation transcript:

RTF Management Updates Jennifer Anziano Regional Technical Forum September 22, 2015

Topics for Today Proposed Meeting Dates Updated Prescriptive Duct Sealing Spec New Measure Proposals – DHP for New Construction – LED Fixtures Upcoming Topics 2

Proposed RTF Meeting Dates Jan (Wed/Thu) Feb 17 (Wed) Mar 15 Apr 19 May 17 Jun 21 Jul 19 Aug 16 Sep 20 Oct 18 Nov 8 Dec 6 3 – Meeting Dates

Prescriptive Duct Sealing MH Spec Please note: These specifications are intended as the minimum requirements to achieve, on average, the RTF's UES estimates. Programs should consider adding requirements to reduce negative impacts on health and safety, to reduce costs, to increase the measure life, and to increase energy savings. 1.Ducts must not have been previously sealed with mastic. 2.Appropriate materials and duct sealing methods shall be used. A.UL-181 listed mastic is an appropriate material to seal non-flexible duct connections. Cloth-backed duct tape shall not be used to seal, secure, or fasten ducts. Loose tape shall be removed prior to sealing. Secured tape that remains must be completely covered with mastic. Where there are large gaps in sheet metal or duct connections, repairs shall be made using sheet metal, sheet metal screws, and/or mastic with mesh-reinforcing tape (for holes or gaps less than 1 inch). B.For flexible crossover ducts, both the inner and outer lining shall be tightly fastened using a compression strap tightened with a tool designed for that purpose. 3. End caps shall be made of either sheet metal or a UL-181 approved rigid product, and sealed. 4. Ducts shall be sealed from the interior at every supply register (boot-to-duct connections, floor-to-boot gaps, and any other duct connections within an arms reach). 5. Plenum connections shall be sealed (plenum-to-furnace connection and plenum-to-trunk duct connection). 6. Crossover duct connections shall be sealed (crossover duct takeoff-to-trunk and crossover duct-to-collar connections). 7. Inferior sections of crossover duct, such as rusted, crushed, disconnected, torn, or sections otherwise ineffective, shall be repaired or replaced. New crossover ducts shall be insulated to a minimum of R8. 8. Crossover duct shall be mechanically fastened and supported to avoid disconnection and airflow restrictions. Measure page 4 – Prescriptive Duct Sealing

New Measure Proposal: LED Fixtures Measure Name: LED Fixtures Likely Measure Type:UES Likely Measure Category:Proven Measure Sector:Residential End-Use:Lighting Proposing Party:BPA [ currently BPA Qualified] Interested Party: BPA Regional Potential:150 to 200 aMW [overlaps with Screw-in Lamp potential] 5 – New Measure Proposal

Measure Details Measure Identifiers Fixture Type – Ceiling and Wall Flush Mount – Track Light – Exterior Security – Exterior Porch – Linear Shop Light – Linear Flush Mount – Downlight Retrofit Kit hide Delivery Mechanism – Retail – Direct Install – Give Away – Mail by Request 6 – New Measure Proposal Specification Fixture with integrated LED or Fixture with separate LED lamp provided in package

Regional Potential ~150 to 200 aMW over the next 20 years Overlaps with savings potential from CFL and LED lamps 131 million fixtures in RBSA. Assume 50% of this is installed (new, replace) over 20 years. 7 – New Measure Proposal

Data Sources Online shelf survey of regional home improvement stores – Current practice mix of technologies (LED, not-LED) – Incremental cost (analysis of lowest cost units, ideally matched-pair) – [Bonneville will provide] BPA/NEEA Lamp Shelf/Sales Analysis – Current practice for pin-based lamps (for Track Light) – Current practice for T8 lamps (for Linear Shop and Linear Flush Mount) – [Bonneville will provide if available] RTF Residential Screw-in Lamps Analysis – Current practice for screw-base fixtures (what lamps we assume socket-based fixtures get filled with) RBSA – Hours of Use by fixture type – % Conditioned Space by fixture type 8 – New Measure Proposal

New Measure Proposal DHP for New Construction 9 – New Measure Proposal Measure Name: DHP for New SF Measure Category: Planning Measure Sector: Residential End-Use: New SF Proposing Party: BPA Regional Potential: Medium

Challenges to Work Through Study Design: Data from the WSU study, but may not be able to use results directly – Design of study does not necessarily encourage the same behavior that we might expect (on the meter) Baseline: What is the baseline heating system type? – Zonal electric resistance: good savings (assumed in WSU study) – Zonal/DHP hybrid: zero savings – Electric forced air furnace: very good savings – Central heat pump: savings close to zero – Gas forced air furnace: negative electric savings – Likely a mix of above (could exclude gas where unavailable) 10

Proposed Timeline Ideally, BPA would like to see these measures addressed by November/December – LED Fixtures: Seems realistic – DHP for New construction: May take time to work through baseline question 11

Proposed Decision “I _____ move that the RTF allocate staff resources towards developing (choose) a Residential LED Fixture UES Measure a Residential DHP for New Construction UES Measure.” 12 – New Measure Proposal

Upcoming Meeting Topics Anticipated in October Prescriptive Duct Sealing SF (Planning) – Revisit savings and costs – Develop Research Strategy Performance Based Duct Sealing SF (Planning, Under Review) – Need a Research Strategy to be active Manufactured Homes Heat Pump Related Measures Research Strategy – Need to incorporate New Construction piece Residential Behavior Standard Protocol – Discuss path forward for RTF work on residential behavior Residential DHW – Showerhead – Align parameters in this measure with the Thermostatic Shower Restriction Valve New Construction – ENERGY STAR (Idaho/Montana) – Update the measures as needed for new codes and/or specifications Proposed Cost Effectiveness Methodology for Seventh Plan 13 – Upcoming Meeting Topics

Upcoming Meeting Topics Anticipated in November/December Residential Heat Pump Upgrades (New Construction) Non-Residential Lighting Standard Protocols – Revisiting Retrofits protocol with any available data – Scoping out New Construction/Code Compliant protocol Scientific Irrigation Scheduling – Sunset date extension and research update Delivery Verification Batch 3 Residential Appliances – Dishwashers Multifamily Calibration, Weatherization, and New Construction Guidelines Updates 14 – Upcoming Meeting Topics