Fig. 3 shows how a dose distribution that is initially relatively sharp becomes blurred with time, until after 16 hours, virtually no useful information.

Slides:



Advertisements
Similar presentations
IMAGE GENERATION IN CT.
Advertisements

Computers and Computed Tomography
Image Reconstruction.
Image Quality Bushong Chapter 7.
IMAGE QUALITY.
Computed Tomography II
NC HPS Meeting 10/18-19/2001 Boone, NC Recent Advances in CT Technology and Issues of CT Dosimetry T. Yoshizumi 1,2, M. Sarder 1, R. Reiman 1,2, E. Paulson.
Image reconstruction and analysis for X-ray computed microtomography Lucia Mancini 1, Francesco Montanari 2, Diego Dreossi 3 1 Elettra - Trieste 2 A.R.P.A.
IMAGE QUALITY NOISE LINEARITY CROSS-FIELD UNIFORMITY IMAGE ARTIFACTS.
CT Physics V.G.Wimalasena Principal School of radiography.
Computed Tomography III
Introduction Radiosensitive polyacrylamide gels (PAG) provide a method of mapping dose distributions in 3D with sub-millimetre resolution [1]. Largely.
Optimisation of X-ray micro-tomography to perform low-dose imaging of highly-dosed gels P.M.Jenneson, E.C.Atkinson, P.Wai and S.J.Doran In 1993, Maryanski.
Introduction A Fricke gel was the first dosimetric system to offer the possibility of making 3-D radiation dose measurements in a totally non-destructive.
Introduction Three-dimensional gel dosimetry is a novel method for radiation measurement motivated by the need to verify experimentally the doses produced.
Reduced Dose of Proton CT Compared to X-Ray CT in Tissue-Density Variation Sensitivity T. Satogata, T. Bacarian, S. Peggs, A.G. Ruggiero, and F.A. Dilmanian.
Uni S School of Electronics and Physical Sciences Department of Physics University of Surrey Guildford Surrey GU2 7XH, UK Optimisation of X-ray micro-tomography.
Introduction Spectrophotometry has been the conventional technique for measuring optical density of irradiated gels [1]. Later, magnetic resonance imaging.
tomos = slice, graphein = to write
Introduction Following Gore’s observation [1] that the well known method of Fricke dosimetry [2] was ideally suited to a “readout” by Nuclear Magnetic.
Chapter 2 Stewart C. Bushong
Introduction The effect of air-cavities within the human body, for example in the head and neck regions, present possible sources of error when calculating.
1© Manhattan Press (H.K.) Ltd. Reflection Refraction Refraction 12.1 Reflection and refraction Total internal reflection Total internal reflection.
Conventional and Computed Tomography
…….CT Physics - Continued V.G.WimalasenaPrincipal School of radiography.
LEC ( 2 ) RAD 323. Reconstruction techniques dates back to (1917), when scientist (Radon) developed mathematical solutions to the problem of reconstructing.
Basic principles Geometry and historical development
Basic Principles of Computed Tomography Dr. Kazuhiko HAMAMOTO Dept. of Infor. Media Tech. Tokai University.
S Dr. S. J. Doran Department of Physics, University of Surrey, Guildford, GU2 7XH, UK High-resolution measurements of radiation dose in 3-D using gel dosimetry.
Hg lamp Cylindrical lens, pinhole and filter  pseudo point-source Lens  parallel beam Scanning tank with matching medium Exposed gel Unexposed gel Diffuser.
Introduction A modification of the Fricke solution system to make it suitable for low-level dosimetric studies was proposed about three decades ago [1].
Test of the proposed method Introduction CCD Controller CCD Illuminator gel Filter 585nm Assembling the phantom before its irradiation. The phantom, ready.
Evaluation of the Performance of the Fast Scanning Platform of an OCT System Malcolm Heard 1, Miguel Herrera 1, Geoffrey Ibbott 1 1 Department of Radiation.
10/17/97Optical Diffraction Tomography1 A.J. Devaney Department of Electrical Engineering Northeastern University Boston, MA USA
Seeram Chapter 7: Image Reconstruction
Healthcare research in the Physics Department Dr S J Doran Lecturer in Magnetic Resonance Imaging Department of Physics School of Electronics and Physical.
Introduction Since 1996 [1], it has been clear that optical computed tomography (CT) represents a viable alternative to MRI scanning of dosimeter gels.
Ramifications of Isotropic Sampling and Acquisition Orientation on DTI Analyses David H. Laidlaw 1, Song Zhang 1, Mark Bastin 2,3, Stephen Correia 4, Stephen.
Computed Tomography Q & A
Nuclear Instrumentation Laboratory Federal University of Rio de Janeiro -BRAZIL X-ray Fluorescence and X-ray Transmission Microtomography Imaging System.
Medical Image Analysis Image Reconstruction Figures come from the textbook: Medical Image Analysis, by Atam P. Dhawan, IEEE Press, 2003.
S Optical CT scanning of PRESAGE TM polyurethane samples with a CCD-based readout system S J Doran 1*, N Krstajic 1, J Adamovics 2 and P M Jenneson 1 1.
Factors affecting CT image RAD
In Burst experiments, the read gradient is much larger then the other imaging gradients, hence, only translation along this gradient direction will cause.
Introduction Magnetic resonance (MR) imaging is recognised as offering potential benefits in the delineation of target volumes for radiotherapy (RT). For.
IAEA International Atomic Energy Agency Optimization of Protection in Computed Tomography (CT)-What can radiographers do? IAEA Regional Training Course.
Technical development of a high resolution CCD-based scanner for 3-D gel dosimetry: (I) Scanner construction S J Doran, K K Koerkamp*, M A Bero, P Jenneson,
Results Fig. 4a shows the raw, noise-free, simulation data for a sample with T 1 = 1 s and T 2 = 100 ms. A clear difference is seen between the cases where.
Xoft Routine Per Article Manufacturing Testing of the Axxent ® Source S. Axelrod, T.W. Rusch, M. Powell; Xoft, Inc., Fremont, CA  Purpose: To select sources.
CT IMAGE RECONSTRUCTION  Hounsfield envisioned dividing a slice into a matrix of 3-dimensional rectangular boxes (voxels) of material (tissue). Conventionally,
Conclusions Despite being able to acquire successfully high resolution images of radiation dose, image quality is limited by hardware problems. Upgrading.
Conclusions Simulated fMRI phantoms with real motion and realistic susceptibility artifacts have been generated and tested using SPM2. Image distortion.
Part No...., Module No....Lesson No
S Department of Physics, University of Surrey, Guildford, GU2 7XH, UK
CT Chapter 4: Principles of Computed Tomography. Radiography vs. CT Both based on differential attenuation of x-rays passing through body Radiography.
Impact of Axial Compression for the mMR Simultaneous PET-MR Scanner Martin A Belzunce, Jim O’Doherty and Andrew J Reader King's College London, Division.
Investigation into the radiochromic (FXG) gel dosimeter: stability and uncertainty in optical measurements M A Bero, S J Doran and W B Gilboy Department.
SL/BI 16/05/1999DIPAC’99 -- JJ Gras -- CERN SL/BI -- Adaptive Optics for the LEP 2 SR Monitors G. Burtin, R.J. Colchester, G. Ferioli, J.J. Gras, R. Jung,
Monday Case of the Day History: Multiple examinations from a CT scanner using a standard helical scan protocol show diffuse hypointense regions of artifact.
Purpose N-isopropylacrylamide (NIPAM) polymer gel dosimeters were employed to verify the dose distribution of clinical intensity modulated radiation therapy.
DESCRIPTION OF PIXIRAD  The PIXIRAD Imaging Counter is an INFN-Pisa Spin-off  It works in photon counting  Pulse discrimination with two thresholds.
Computed Tomography Computed Tomography is the most significant development in radiology in the past 40 years. MRI and Ultrasound are also significant.
IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.
Date of download: 9/20/2016 Copyright © 2016 SPIE. All rights reserved. (a) Photographs of the anthropomorphic phantom used in this study and (b) the inner.
Sunday Case of the Day Physics
Excitation based cone-beam X-ray luminescence tomography of nanophosphors with different concentrations Peng Gao*, Huangsheng Pu*, Junyan Rong, Wenli Zhang,
Monday Case of the Day Physics
An Improved CRT Resolution Measurement System Using MTF Method
A. Nisbet 1,2, A. Dimitriadis 1,2,3, A.L. Palmer 1,4, C.H. Clark 2,3
Computed Tomography (C.T)
Presentation transcript:

Fig. 3 shows how a dose distribution that is initially relatively sharp becomes blurred with time, until after 16 hours, virtually no useful information remains. We used the following formula to simulate the diffusion of the xylenol-iron complex in 2D: Introduction This poster describes preliminary results that have been obtained using a new optical computed tomography (OCT) scanner [1]. Our goals were, firstly, to demonstrate that dose maps can be obtained with a high spatial resolution and, secondly, to assess the seriousness of blurring in the dose map caused by diffusion of the coloured indicator which records the position of the deposited dose. Technical development of a high-resolution CCD-based scanner : 2. Initial results Acknowledgements KKK was supported by the EU Socrates exchange programme. The authors thank C Bunton for technical help. References [1] S J Doran et al., Phys. Med. Biol. 46 in press [2] M A Bero et al. NIMB 166, 820 (2000) Conclusions Good quality images have been obtained from a novel OCT scanner, with a resolution of 560  m in plane and slice thickness 140  m. Some residual artifacts remain. The extent to which diffusion affects the images has been quantified. S S J Doran, K K Koerkamp*, M A Bero, P Jenneson E J Morton and W B Gilboy Department of Physics, University of Surrey, Guildford, GU2 7XH, UK Department of Applied Physics, University of Twente, Enschede, The Netherlands * t=0 t=1 hr t=16 hr Figure 2: Experimentally measured dose profile for the highest dose beam in Experiment 1. x / pixels y / pixels Nominal Dose / Gy Approximate level of isosurface Figure 1: Results of Experiment 1, as described in the main text: (a) normal windowing level; (b) windowing level adjusted to display residual image artifacts; (c) result obtained without employing correction for reflection and refraction at the container walls; (d) 3-D reconstruction of the dose map — note the tapering of the low intensity beam. This is a combination of beam attenuation as the beam passes through the gel and beam profile (Fig. 2); as the beam becomes more attenuated, less and less of it lies above the iso-surface level shown in red in Fig. 2. Incident X- rays cab 0 Gy- 6 Gy 6 Gy 0 Gy 10 Gy 57 mm d Materials and methods Two samples of a ferrous xylenol gelatin (FXG) mixture were manufactured in cylindrical polystyrene containers using the procedures described in [2]. The concentrations of the active reagents were: Fe mM, H 2 SO 4 25 mM and xylenol orange 0.1 mM in Experiment 1 and 0.05 mM in Experiment 2. The samples were irradiated with a newly-installed, experimental X-ray tube, capable of delivering an intense and highly collimated beam. In Experiment 1 the sample was irradiated four times in an axial direction with beams of duration 20, 15, 10 and 5 minutes, each at 100 kVp and 20 mA. An OCT scan was then acquired, consisting of 402 projections each of 512  100 pixels. This was reconstructed using filtered back-projection, at a variety of in-plane resolutions to obtain a 100-slice dataset with slice thickness 140  m. The acquisition time was approximately 38 minutes. Results are shown in Fig. 1. In Experiment 2 the sample was irradiated three times axially. In order to visualise quantitatively the effects of diffusion, the sample was imaged immediately after irradiation and then again at 1 hour and approximately 16 hours post-irradiation. The results of this study are shown in Fig. 3. Discussion Fig. 1(a) shows that high resolution dose maps can be obtained successfully by OCT. The data have been reconstructed on a 128  128 pixel matrix. The use of 402 (i.e., ~128  ) projections ensures that the nominal pixel resolution matches the image resolution that we “genuinely” have at the edge of the field- of-view (FOV), in this case 560  m. Towards the centre of the FOV, the data support a higher resolution. Fig. 2 shows the 2-D profile of one of the beams, which is not sharp. This effect might have been caused by either the presence of a beam penumbra or diffusion of the imaged species. The results of the second experiment are necessary to determine how big a part diffusion has played. By using the image acquired at t = 0 as our best estimate for C(x 0, y 0, t 0 ) and integrating over (x 0, y 0 ), we obtained an estimate of the dose distribution at a later time. The only free parameter in the simulation is D. So, by systematically varying D and comparing the result with the experimental image at 1 hr, we can make a good estimate of the Fe-XO diffusion coefficient. Figure 3: OCT images of the sample of Experiment 2. The graph shows data points corresponding to experimental profiles across the lowest dose beam at t = 0 and t = 1 hr with the results of the diffusion simulation overlaid.