NFS2 - 3030 System Components & Installation.

Slides:



Advertisements
Similar presentations
Variable Frequency Drives Bypass Options
Advertisements

Nexus 1-8 Loop (XP95) Analogue Addressable Control Panels
ID to 8 Loop Intelligent Fire Alarm Panel
Integrated Technology!
NetSure™ RDB Series.
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
Poseidon 4002 Rack monitoring 1. Poseidon: Monitor & Control 2.
EMerge Browser Managed Security Platform Module 2 Hardware install.
Detailed Room Guides Select from the list of Willard Building technology classrooms to view more detailed operating instructions. The instructions are.
GS3055-I GSM Universal Wireless Alarm Communicator
System Capacity MAP 5000 Release 1.2 Feature Overview
Trouble - Shooting ELR - Electric Latch Retraction.
PXL-500/-510 Tiger Controller II
Introduction System Schematic ~ LON-FO NC EC200 LOOPS 2-4 FIBRE OPTIC
ONYX Digital Voice Command
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
Cabinetry.
EST3 Network Communications
Training.
AS-i, The Simplest Automation Networking Solution Dated: 10/30/2008.
MUST HAVE SHOULD HAVE COULD HAVE Module # 010. Qi Hardware Objectives Recognize hardware Know how to interface to field equipment Know the 4 different.
Confidential Document 1 EverAccess Product Overview By Julian Garcia.
Precept Conventional Control Panels
ONYX Product Overview.
INTRUSION ALARM TECHNOLOGY
E VERY L IFE H AS A P URPOSE… Chillgard ® L Series Refrigerant Monitors.
NOTIFIRE NETWORK.
Addressable Fire Alarms
RP-2000 Series Deluge & Agent Releasing Panels
High Speed NCM (HS-NCM)
Main Water Leak Detection Panel (SY3618) Features: 1.Operates on 230 V A.C. 2. Provides supervision of Interface modules. 3. LCD display to indicate Module.
TF Joint Voltage Drop Instrumentation Robert Marsala (609) Hans Schneider (609) Engineering Operations August 7, 2003 TF_JOINT_Final_Design_Review.ppt.
System Elements HighPoint Broadband Delivery System Sector 1 Sector 3
PROFIBUS wiring/installation can be done with:
NOTIFIER® ONYX® Series Overview
NFS System Components & Installation.
MarsⅡ On-Line UPS Series
2HONEYWELL - CONFIDENTIAL File Number ACM-24-AT Series A1P1 A1P2 A1P3 A1P4.
Private and Confidential TraceTek iServer Concepts, Set-up, Operation.
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
ENERGY of 21 st Century Independent Power Supplies.
Single Loop Analogue addressable fire control Panel
High Sensitivity Smoke Detection
DIGITAL VOICE COMMAND (DVC)
ACS Annunciators. EIA-485 specification Overview RPT May extend the length 4,000 feet.
PWC Preferred Instruments a division of Preferred Utilities Mfg. Corp. Plant Wide Controller (PWC) Overview.
Datron World Communications Inc. RT7000 HF TRANSCEIVER FIELD MAINTENANCE PROCEDURES.
BOOT MODE 1 BOOT MODE 2 BIOS COMMUNICATION DEFAULT CONTROLLER INVERT RELAY OPERATION ENABLE COMM FAIL RELAY CONTROL RELAY OFF / ON COMM.
GS3055-I GSM Universal Wireless Alarm Communicator
Intelligent Control Panel SLC
Hardware Training Product: ITMS2.
ADT490 TroubleShooting Locating Opens. 2 Power Supply Grounding Power Supply has circuit -> allows positive & negative outputs to float relative to ground.
2 December, 2015 New Conventional Fire Control Panel.
Precept Marine Conventional Control Panels
ADT490 Panel Theory. 2 System Power Supply Grounding ‣ Circuit separates positive / negative from Ground ‣ Ground fault - resistance to ground ≤ 10 kΩ.
Xplorer 1-2 Loop Analogue Addressable Control Panels From 1-2 loops EN54 2 & 4 Compliance Fully compatible with all Apollo XP95 and Xplorer devices Extensive.
New product introduction:
Confidential Document 1 EverAccess Product Overview By Rodney Guinto.
2 Wire Door Entry System (DES of MH BT offer)
06/18/04 1 Analog Audio Hardware and Operations. 06/18/04 2 Module 5 Objectives Upon completion of this module, the student will be able to:  Explain.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
LED1 LED2 LED8 LED9 LED7 LED6 LED5 LED4 CON1 CON4 CON2 CON3 CON5 CON6 A00380 Control Board LED10 JP12 JP10 JP11 LED11 LED12 LED13 LED14 A00380 LED’S.
System Network Structure
Redundancy Switching Components
Multi Channel Interface & Basic Amplifier
Multi Channel Interface & Basic Amplifier
Module 1 – Power Supply AMC APS-PBC-60
Honeywell Fire Systems Group RFX SLC L1: Det.159 Mod. 159 SLC L2: Det.159 Mod. 159 SLC L3 ~ L10 EIA 485 EIA 232 RDP Up to 32 Noti-Fire-Net Onyxworks.
Presentation transcript:

NFS2 - 3030 System Components & Installation

Noti-Fire-Net Onyxworks SLC L3 ~ L10 RDP Up to 32 SLC L2: Det.159 Mod. 159 RFX 4 Set On Board Relay O/P SLC L1: Det.159 Mod. 159 EIA 485 Noti-Fire-Net EIA 232 Onyxworks

ALARM TROUBLE SUPV SCTY TB7 ACS TB9 RDP TB5 PRN TB4 TB3 TB2 TB1 ALARM TROUBLE SUPV SCTY TB7 ACS TB9 RDP TB5 PRN J7 SLC J1 NUP J6 SCTY J2 LCD J5 TROUBLE J4 BACKLIGHT TB6 +24V P12 & 13 Memory back up battery (3v, 300mA) TB1 thru TB4 Scty / Supv / Tble / Alarm relays SW1 & SW2 to change TB1 & TB2 to Alarm relays TB7 EIA485 data to ACS TB9 EIA485 Remote Data Port to LCD160 TB5 EIA232 to printer TB6 1.0a of 24v power J1 NUP port J2 LCD connection for display J4 Display backlight connection J9 Keypad connection J7 LCM-320 connection to J1 J13: Power connection to AMPS-24 (TB2) J5 & J6 Trouble bus & Security switch connection Service level LEDs Service level switches (SW3 thru SW6 ACK / SIL / RST / LAMP TEST) J13 AMPS-24 J9 KEYPAD

Function Keys Function LEDs Display & Function Keys Function LEDs 640 character backlit display 160 characters for device information Service level LEDs (AC Power thru CPU Failure) Function & display sort keys Softkeys for read status & programming choices QWERTY keypad Curser movement keys Other function keys: Next / Previous / Lamp test

LEM is always the ODD numbered loop Flashprom for upgrades. SLC WIRING TO NEXT LCM FROM CPU J7 or LCM LCM-320 P36 Addressable (1/2 3/4 5/6 7/8 9/10) LEM is always the ODD numbered loop Flashprom for upgrades. Connection from CPU (J7) to J1 of LCM. From LCM J3 to next LCM J1 Do not have to be installed in any specific order. LEM CONNECTION

Loop Modules LCM-320 LEM-320 LEM Ground Fault J3 J1 J2 JP1 D33 +5V D32 D28 B+ A+ B- A- SLC JP2 TB1 JP3 SW1 EG FAULT LEM Ground Fault Note each Loop may be designated for Style 4 or Style 6 operation Note each Loop may have devices programmed for CLIP or FLASH operation. If Modules are selected for CLIP, Rapid Polling must be enabled to ensure correct response time of Manual Stations (require addresses 01-20) Note J1 LCM Connector Cable (p/n 75655) input Note J3 LCM Connector Cable output Note J2 LCM & J1 LEM Connector plugs LEM mounts behind LCM and assumes the sequential Loop Address Note Loop Address selector switch Note Ground Fault LEDs D28 (lower) LCM, D32 (upper) LEM LCM Ground Fault LCM-320 LEM-320

LCM Cables Note Lower Connection of each LCM is the Input Connector

LCM/LEM SLC Connector Typical Style 6.0/7.0 Typical Style 4.0 Channel B Channel A Channel A Return Channel B Output Wiring distance per channel (style 4)or per loop (style 6 or 7) not to exceed 12,500 ft. Resistance not to exceed 50 Ohms In Style 4, both channel A and B may be used.

SW1 Configuration Switches AMPS-24(E) Power Supply TB1 SLC TB2 CPU TB6 Accessory Power TB3 AC SW1 Configuration Switches TB4 & 5 DC SW4 Charger Selection Status LEDS P11 LED1 Green – AC. Steady – AC Normal; Blink – AC Fail Delay LED2 Yellow – Battery or charger trouble LED4 Yellow – Trouble. 1 blink & pause = AC Fail; 2 blinks & pause = Internal PS Fail; 3 blinks & pause = Incorrect SLC address; 5 blinks & pause = Charger Shutdown; 6 blinks & pause = Accessory Power (TB6) overload; Steady = Panel Output overload/Accessories Output shut off. LED5 Green – SLCRXA. Blinks when data is received from SLC LED6 Yellow – UCFAILURE. Steady if AMPS Microprocessor fails LED7 Green – SLCTXA. Blinks when data is transmitted to SLC LED8 Green – ACCESSORIES. Steady for Normal TB6 output. Off during overload LED9 Yellow – GND FLT. Steady for Ground on any output or battery lead LED10 Green – 24VPANEL. Steady when TB2 is active. Off during overload TB3 AC connection P21 TB4 DC connection (55 to 200 Ah batteries) P23 F2 10a Fuse for connection protection TB1 SLC connection P19 TB2 Connection to CPU (J13) P18 TB6 Accessory output (5V & 24V @1a) P20 SW1 Configuration switches (only use SW1-1, 1-2, 1-7 & 1-8 for 2-3030) P28 SW2 & SW3 SLC address selection switches P29/30 Must start at 05 as a minimum Uses 4 addresses: Gen Trouble / AC Loss / Battery Fail / GF SW4 Charger selection switch P22 LO-2.0a for 25aH HI-5.0A for 55-200aH

AMPS-24E (New Version) AC Input: AC 220V DC Output: 24VDC, 5A for CPU 24VDC, 3A for External Devices Battery Charger: 24VDC 7 – 200AH

Base Address Setting

Properties setup via software kit

Setup Battery and Charger Current

APS2-6RE – Auxiliary Power Supply AC Input: AC 220V DC Output: 24VDC, 3A (2 set) 24VDC, 6A (1 set) (Total 24VDC, 6A)

Addressable Charger Power Supply ACPS 610(E) AC Input: AC 220V DC Output: 24VDC, 1.25A x 4 Circuits Battery Charger: 24VDC 7 – 200AH ACPS-2406 Addressable Charger Power Supply 5 to 13 programmable addresses General Monitoring or unique addresses for AC fail, battery trouble and ground fault Four addressable output circuits Single Stage or dual stage (Canada) module addressing Optional Signal Silence Address command Refer to D/N 51304 for additional information

LCD-160 Remote Display 160 character display Custom graphics Tactile keypad DCC participation TB2 24v Power From AMPS-24 From APS-6R Max 10 ohms TB1 RDP Bus 12 to 18 AWG Max 4K feet total Max 100 ohms Installation guidelines on page 13 DN 51850 Max 4K ft of 12/16 AWG twisted pair 100 ohms on RDP and 10 ohms on power ckt SW17: 1: Programming Address change Piezo on/off LCD Display 2: ELR 3: Off 4: Off SW17 #1 ON: Prog #2 ON: ELR

ACS Annunciators A1P1 A1P2 A1P3 A1P4 ACM(AEM)-24AT ACM (AEM) – 48 A

ACS Annunciators ACM-8R LDM-32 series 1 2 3 4 5 7 9 8 6 1 2 3 4 5 6 7 8 LCD-80 only operates in ACS mode on the 3030. It requires 1-4 consecutive 64PT ACS addresses in programming. ACM-8R and LDM series annunciators are defined as 64PT ACS devices ACM-8R LDM-32 series

ACS Annunciators SCS-8 Smoke Control Station Switch Group 5 Group 6 All Auto Manual Acknowledge The SCS-8 is defined as a 64PT FSCS device. Points 1-64 allow assignment of individual Monitor and Control Modules for smoke control. Points 65-96 provide “monitor” addresses for FCSC mode shutdown command. The UZC-256 takes 1-4 consecutive 64PT ACS addresses SCS-8 Smoke Control Station

Smoke Control Station Up to four modules/group Control On Control Off Monitor On Monitor Off SCS-8 Up to four modules/group Three position toggle switches On / Off / Auto

Network Communications Module To communicate with another Onyx control panel on a network, the Onyx Panels requires an Network Control Module. The NCM is capable of working on a either a wire or a fiber network. NCM-W (Wire) NCM-F (Fiber optic) Mounting Options: In a standard Chassis position. On the right side of a DAA Audio Amplifier. Underneath the DVC Digital Video Controller. NCM-W

Point-To-Point Configuration A point-to-point wiring configuration is defined as a twisted-pair segment with only two nodes/repeaters attached to it. Terminating resistors are required at each end of every segment, and are built into each MIB/RPT/NCM. A B Network Node or RPT

Point-To-Point Configuration Wiring a Noti-Fire-Net in NFPA Style 7 point-to-point. A B Network Node or RPT

CPU-3030D or CPU-3030ND Both CPU options require a CHS-M3 chassis for mounting in the top position of the cabinet. CPU2 mounting The output modules may require an additional power supply AMPS-24(E) BATTERY LCM/LEM and NCM-W/F can be installed in the two right-hand positions. SBB-D4 D-Size Backbox

CHS-4L CHS-4L Chassis, low profile, 4 positions for mounting the LCM/LEM, NCM-W/F, APS-6R, LDM-32, BACNet GW... The output modules may require an additional power supply D-Size Backbox

*Use to BMP-1 Blank Module plate to cover unused single positions Dress Panels & Plates DP-DISP Display Dress Plate DP-1B Blank Dress Plate, 4 row The tricky part is sometimes there are optional mounting solutions for the same component depending upon where in the cabinet it is to be installed or what other equipment will be located inside the cabinet. Most of the hardware has multiple uses as well. If we had a Price List with pictures and rules for use, however unfeasible that may be, it might not be too difficult to determine your hardware requirements. But that’s not the case. You just gotta learn all this stuff. ADP-4B Annunciator Dress Plate* BP2-4 Battery Dress Plate *Use to BMP-1 Blank Module plate to cover unused single positions

Page 19 DR-A4 SBB-A4 The assembly consists of a back box and a locking door with two keys. The back box and door can be ordered separately or as a complete unit. Doors may be hinged right or left. A semi-flush trim ring kit is available for each box size. 32 41

Page 19 DR-B4 SBB-B4 42

Page 20 DR-C4 SBB-C4 43

Page 20 DR-D4 SBB-D4 33 44

ABS-2D ABS-4D

Any Questions?