Hill et al.MOP Conference, Boston, 11 July 20111 Charged Nanograins in the Enceladus Plume Tom Hill, Rice Univ. Michelle Thomsen, LANL Robert Tokar, LANL.

Slides:



Advertisements
Similar presentations
QUICK QUIZ 23.1 (For the end of section 23.2)
Advertisements

Dusty plasma near Enceladus South Pole M. Shafiq, M. W. Morooka and J.-E. Wahlund Swedish Institute of Space Physics, Uppsala, Sweden.
Evidence at Saturn for an Inner Magnetospheric Convection Pattern, Fixed in Local Time M. F. Thomsen (1), R. L. Tokar (1), E. Roussos (2), M. Andriopoulou.
Searching for N 2 And Ammonia In Saturn's Inner Magnetosphere Polar Gateways Arctic Circle Sunrise 2008 Polar Gateways Arctic Circle Sunrise January.
LIGHTNING PHENOMENON 1. The height of the cloud base above the surrounding ground level may vary from 160 to 9,500 m. The charged centres which are responsible.
Inner Source Pickup Ions Pran Mukherjee. Outline Introduction Current theories and work Addition of new velocity components Summary Questions.
Saturn’s Aurora from Cassini UVIS Wayne Pryor (Central Arizona College) for the UVIS team.
Comparing the solar wind-magnetosphere interaction at Mercury and Saturn A. Masters Institute of Space and Astronautical Science, Japan Aerospace Exploration.
Auxiliary slides. ISEE-1 ISEE-2 ISEE-1 B Locus of  = 90 degree pitch angles Will plot as a sinusoid on a latitude/longitude projection of the unit.
Max P. Katz, Wayne G. Roberge, & Glenn E. Ciolek Rensselaer Polytechnic Institute Department of Physics, Applied Physics and Astronomy.
Titan’s Thermospheric Response to Various Plasma Environments Joseph H. Westlake Doctoral Candidate The University of Texas at San Antonio Southwest Research.
Sub-THz Component of Large Solar Flares Emily Ulanski December 9, 2008 Plasma Physics and Magnetohydrodynamics.
Summer student work at MSSL, 2009 Kate Husband – investigation of magnetosheath electron distribution functions. Flat-topped PSD distributions, correlation.
Susy05, Durham 21 st July1 Split SUSY at Colliders Peter Richardson Durham University Work done in collaboration with W. Kilian, T. Plehn and E. Schmidt,
Rutherford Backscattering Spectrometry
Chapter 21 & 22 Electric Charge Coulomb’s Law This force of repulsion or attraction due to the charge properties of objects is called an electrostatic.
F. Cheung, A. Samarian, W. Tsang, B. James School of Physics, University of Sydney, NSW 2006, Australia.
TOF Mass Spectrometer &
Electrons at Saturn’s moons: selected CAPS-ELS results A.J. Coates 1,2. G.H. Jones 1,2, C.S.Arridge 1,2, A. Wellbrock 1,2, G.R. Lewis 1,2, D.T. Young 3,
NASA Cassini Spacecraft Technology Report Nicole Iwaki ITMG
1 Origin of Ion Cyclotron Waves in the Polar Cusp: Insights from Comparative Planetology Discovery by OGO-5 Ion cyclotron waves in other planetary magnetospheres.
Geraint Jones CHARM Telecon, February 24, 2009 Rings around a moon? The puzzling case of Rhea. Image courtesy NASA/JPL/SSI Geraint Jones Mullard Space.
Perpendicular Flow Separation in a Magnetized Counterstreaming Plasma: Application to the Dust Plume of Enceladus Y.-D. Jia, Y. J. Ma, C.T. Russell, G.
Negative ions at Titan: tholins for Titan’s haze? Andrew Coates, Mullard Space Science Laboratory, UCL, UK With thanks to Frank Crary, Dave Young, Hunter.
30.5 Magnetic flux  30. Fig 30-CO, p.927
Multi-fluid MHD Study on Ion Loss from Titan’s Atmosphere Y. J. Ma, C. T. Russell, A. F. Nagy, G. Toth, M. K. Dougherty, A. Wellbrock, A. J. Coates, P.
CODIF Status Lynn Kistler, Chris Mouikis Space Science Center UNH July 6-8, 2005 Paris, France.
 Introduction  Surface Albedo  Albedo on different surfaces  Seasonal change in albedo  Aerosol radiative forcing  Spectrometer (measure the surface.
Space Science MO&DA Programs - September Page 1 SS It is known that the aurora is created by intense electron beams which impact the upper atmosphere.
PAPER I. ENA DATA ANALYSIS RESULTS. The Imager for Magnetopause-to- Aurora Global Exploration (IMAGE) missionis the first NASA Mid-size Explorer (MIDEX)
The state of the plasma sheet and atmosphere at Europa D. E. Shemansky 1, Y. L. Yung 2, X. Liu 1, J. Yoshii 1, C. J. Hansen 3, A. Hendrix 4, L. W. Esposito.
1 The Organic Aerosols of Titan’s Atmosphere Christophe Sotin, Patricia M. Beauchamp and Wayne Zimmerman Jet Propulsion Laboratory, California Institute.
Saturn neutral particle modeling Overview of Enceladus/Titan research with possible application to Mercury Johns Hopkins University Applied Physics Laboratory.
Monday, Sep. 20, 2010PHYS 3446, Fall 2010 Andrew Brandt 1 PHYS 3446 – Lecture #4 Monday, Sep Dr. Brandt 1.Differential Cross Section of Rutherford.
1 Electrostatics (static electricity) 2 Electric Charges: Electric charge is a fundamental quantity that is responsible for all electric phenomena. Charge.
INMS quarterly report: Aug.-Sept., 2005 Science highlights –In situ determination of the atmosphere of Enceladus much beyond anticipation - water 90%,
1 PHY Lecture 5 Interaction of solar radiation and the atmosphere.
Gurnett, 2010 BqBq B tot Ring Current and Asymmetric Ring Current Magnetospheres of the Outer Planets - Boston, MA July 13, 2011 BRBqBfBtBRBqBfBt dB q.
Moons of Saturn 14 October Iapetus Mimas.
Simple Approach to Salvaging THEMIS ESA Moments Prior to Boom Deployment Vladimir Kondratovich David G. Sibeck.
PHYS 3446 – Lecture #3 Wednesday, Sept. 3, 2008 Dr. Andrew Brandt
Improving Detection Efficiency of a Space-based Ion Mass Spectrum Analyzer Anne Lamontagne, University of New Hampshire; Mark Popecki, UNH; Lynn Kistler,
Lecture3 Dr. lobna Mohamed Abou El-magd
A. Vaivads, M. André, S. Buchert, N. Cornilleau-Wehrlin, A. Eriksson, A. Fazakerley, Y. Khotyaintsev, B. Lavraud, C. Mouikis, T. Phan, B. N. Rogers, J.-E.
Density trends of negative ions at Titan A. Wellbrock 1,2,3, A. J. Coates 1,3, G. H. Jones 1,3, G. R. Lewis 1,3, C. S. Arridge 1,3, D. T. Young 4, B. A.
Methanol Masers in the NGC6334F Star Forming Region Simon Ellingsen & Anne-Marie Brick University of Tasmania Centre for Astrophysics of Compact Objects.
KL-parameterization of atmospheric aerosol size distribution University of Tartu, Institute of Physics Growth of nanometer particles.
Aerosol distribution and physical properties in the Titan atmosphere D. E. Shemansky 1, X. Zhang 2, M-C. Liang 3, and Y. L. Yung 2 1 SET/PSSD, California,
Saturn’s spin periodicities caused by a rotating partial ring current Krishan Khurana Institute of Geophysics and Planetary Physics, UCLA, Los Angeles,
Results using molecular targets Linear-circular comparison of the intense field ionization of simple molecular targets (N 2, CO 2 ): evidence of nonsequential.
METO 621 CHEM Lesson 4. Total Ozone Field March 11, 1990 Nimbus 7 TOMS (Hudson et al., 2003)
Quarterly 17/18/2007 INMS Team Third Quarter Report July, 2007 INMS Quarterly
15 cm Plots of missing mass spectrum and 90% interval for width of 0.5 and 10 MeV. Color lines show upper limit, lower limit and sensitivity. Search for.
Particle energization at Saturn C. Paranicas 1, E. Roussos 2, P. Kollmann 2, N. Krupp 2, J. F. Carbary 1, D. G. Mitchell 1, S. M. Krimigis 1, B. H. Mauk.
Rev 131 Enceladus’ Plume Solar Occultation LW Esposito and UVIS Team 14 June 2010.
Cassini Imaging Observations of the Jovian Ring H. B. Throop, C. C. Porco, R. A. West, J. A. Burns M. R. Showalter, P. D. Nicholson See also Throop et.
SS Special Section of JGR Space Physics Marks Polar’s 5th Anniversary September 4, 1996 This April special section is first of two Polar special sections.
Copyright © 2009 Pearson Education, Inc. Biot-Savart Law.
OBSERVATION ON ION DYNAMICS Urmas Hõrrak, Hannes Tammet Institute of Environmental Physics, University of Tartu, 18 Ülikooli St., Tartu, Estonia.
Saturn Magnetosphere Plasma Model J. Yoshii, D. Shemansky, X. Liu SET-PSSD 06/26/11.
ESS | Non-Invasive Beam Profile Measurements| | C. Böhme Non-Invasive Beam Profile Measurement Overview of evaluated methods.
Rev 51 Enceladus Zeta Orionis Occultation Analysis Status 9 January 2008.
Cassini UVIS Results on the Enceladus Plume and Spacecraft Safety Larry W. Esposito 5 June 2007 Athens PSG.
Cassini Huygens EECS 823 DIVYA CHALLA.
M. Yamauchi1, I. Dandouras2, H. Reme2,
Enceladus Plume Simulations
Cassini UVIS solar occultation
Dione’s O2 Exosphere C. J. Hansen January 2013.
Electrostatics Charge
Model Calculations of the Ionosphere of Titan during Eclipse Conditions Karin Ågren IRF-U, LTU.
Presentation transcript:

Hill et al.MOP Conference, Boston, 11 July Charged Nanograins in the Enceladus Plume Tom Hill, Rice Univ. Michelle Thomsen, LANL Robert Tokar, LANL Andrew Coates, MSSL Gethyn Lewis, MSSL Dave Young, SWRI Frank Crary, SWRI Raul Baragiola, Univ. VA Bob Johnson, Univ. VA Geraint Jones, MSSL Don Mitchell, JHU/APL Jan-Erik Wahlund, IRFU Rob Wilson, LANL Yaxue Dong, Rice Univ. Mihaly Horanyi, Univ. CO

Hill et al.MOP Conference, Boston, 11 July The South polar plume of Enceladus is revealed here in visual- light images of sunlight forward-scattered by micron-size grains (Cassini ISS, Porco et al., 2006 Science). This later image, also showing the E Ring, is from

Hill et al.MOP Conference, Boston, 11 July This South polar Enceladus plume also contains: Supersonic water vapor with interesting trace impurities (Cassini INMS, Waite et al., 2006 Science; Cassini UVIS, Hansen et al., 2006 Science; Dong et al. poster, this meeting); Cold negative water-cluster molecular ions (CAPS-ELS, Coates et al., 2009 Icarus); Cold positive water-group ions (CAPS-IMS, Tokar et al., 2009 GRL); Dense plasma with n i >> n e (RPWS-LP, Shafiq et al., 2010 PSS); and Charged nanometer-size grains (CAPS, Jones et al., 2009 GRL; this talk).

Hill et al.MOP Conference, Boston, 11 July The cold, charged nanometer-size grains (nanograins) are detectable by CAPS (Cassini Plasma Spectrometer) when CAPS has ram pointing during a plume encounter. This has occurred 3 times to date: E3 (12 Mar 2008) E5 (09 Oct 2008) E7 (02 Nov 2009) All 3 encounters very nearly crossed the south polar axis of Enceladus, but at quite different distances: Z(E3) ~ -3.6 R E Z(E5) ~ -2.3 R E Z(E7) ~ -1.4 R E

Hill et al.MOP Conference, Boston, 11 July CAPS count-rate spectrograms during E3 encounter: ELS: IMS: (-) grains (-) clusters electrons (+) grains (+) ions

Hill et al.MOP Conference, Boston, 11 July CAPS count-rate spectrograms during E5 encounter: ELS: SNG: (-) grains (-) clusters electrons (+) grains (+) ions

Hill et al.MOP Conference, Boston, 11 July The nanograins are cold, as evidenced by the fact that comparison of adjacent CAPS 20° angular sectors (not shown here) indicates an angular beam width < (and possibly <<) 20°. Thus, the best way to extract particle density n from observed count rate CR is the cold-beam algorithm introduced by Coates et al. (2007 GRL) for cold heavy negative ions in Titan’s atmosphere: CR =  nvA where  = detector’s counting efficiency, v = beam speed relative to Cassini, and A = detector’s effective collecting area. We approximate v by the spacecraft encounter speed relative to Enceladus: v  v(ram) = 14.4 km/s for E3 encounter 17.7 km/s for E5 encounter 7.7 km/s for E7 encounter (Beam speed relative to Enceladus is not known but is evidently << v(ram).)

Hill et al.MOP Conference, Boston, 11 July Instrument-dependent parameters in this formula: Effective collecting area A  0.33 cm 2 (ELS) or 0.32 cm 2 (IMS), ± ~ 10% (?) Counting efficiency  ~ 0.05 (ELS) versus ~ 1 (IMS) ± factor ~ 3 (?) (The big difference between  (IMS) and  (ELS) results from the fact that IMS has start foils and ELS does not.)

Hill et al.MOP Conference, Boston, 11 July The cold-beam approximation gives a simple linear conversion between energy/charge (E/q, the measured quantity) and mass/ charge (m/q, the intrinsic grain property): (E/q)/(m/q) = E/m = v 2 /2  1.1 eV/amu for E3 encounter 1.6 eV/amu for E5 encounter 0.31 eV/amu for E7 encounter Evaluating the cold-beam formula for each E/q channel (= m/q channel) gives the mass spectrum of charged nanograins dn/dm = (number density of grains)/(mass channel) assuming singly-charged grains (q = ± e; see below).

Hill et al.MOP Conference, Boston, 11 July Mass spectrum dn/dm for the E3 encounter, for the nanograin portions of the CAPS ELS and IMS E/q ranges, near the respective times of peak nanograin flux. Note that the spectrum is still increasing, or flat, at the top of the CAPS E/q ranges. We can only provide a lower limit to the total nanograin density.

Hill et al.MOP Conference, Boston, 11 July Mass spectrum dn/dm for the E5 encounter, for the nanograin portions of the CAPS ELS and IMS E/q ranges, near the respective times of peak nanograin flux. Note that the spectrum is (again) still increasing, or flat, at the top of the CAPS E/q ranges. We can (again) only provide a lower limit to the total nanograin density.

Hill et al.MOP Conference, Boston, 11 July Integrating dn/dm over m gives total nanograin density within the CAPS E/q range. Same scales for both encounters. Note that n(-) >> n(+) on both encounters, and that n(E3) > n(E5) even though E3 was 2X farther from the surface vents.

Hill et al.MOP Conference, Boston, 11 July The later (and much closer) E7 encounter showed no evidence of (+) nanograins, and a much weaker (but detectable) signal from (-) nanograins with peak total density ~ 1.5/cm 3. The following figure compares the peak nanograin densities for the three plume encounters to date, with CAPS ram pointing. The next such encounter (E14), similar to E7, will occur 1 Oct (Ask me about our prediction for that encounter.)

Hill et al.MOP Conference, Boston, 11 July (r = distance from south pole on surface, not from center of Enceladus.) The nanograin density clearly does not follow the canonical 1/r 2 dependence. By contrast, The neutral H 2 O vapor density measured by INMS does indeed follow the expected 1/r 2 dependence for all three encounters, with similar source densities for all three (Dong et al. poster, this meeting).

Hill et al.MOP Conference, Boston, 11 July An inescapable (to me) conclusion: The nanograins are not significantly charged (e.g., by triboelectric charging) when they leave the surface vents. They are primarily charged by plasma electron impact in transit from Enceladus to Cassini.

Hill et al.MOP Conference, Boston, 11 July Another, even more inescapable, conclusion: The observed nanograins carry a significant unbalanced charge density (n(-) >> n(+)), which increases with distance from the source. Taken in isolation, this would be an embarrassing problem, and would call the CAPS observations into question. However, it fits rather nicely with an opposite charge-imbalance problem posed by the RPWS-LP measurement (Shafiq et al., 2011 PSS) of a plume plasma with n(+) >> n(-) on the E3 plume encounter. The numbers don’t quite match – plasma n(+) - n(-) >~ nanograin n(-) - n(+), but recall that CAPS can give only a lower limit for the latter.

Hill et al.MOP Conference, Boston, 11 July Taken together, the CAPS and RPWS-LP measurements support the notion that the nanograins absorb many of the electrons (an increasing fraction with increasing distance from the source) that balance the charge density of the (+) plasma ions.

Hill et al.MOP Conference, Boston, 11 July Conclusions: Nanograins are a ubiquitous feature of the Enceladus plume. They become charged by electron impact in the plasma, not by friction in the surface vents. The most likely (nonzero) charge state is q = -e. They interact strongly with the dense plume plasma and carry a significant fraction of the negative charge, increasingly so with increasing distance. They provide an important source of both the particulate E ring and the magnetospheric plasma.

Hill et al.MOP Conference, Boston, 11 July Back-up slides

Hill et al.MOP Conference, Boston, 11 July Why is q = ±e the most plausible value? q = 0 is probably the most likely value, but is not detectable by CAPS. Multiple charges are possible, but implausible because: “ghost peaks” are not seen in the data; the expected charging time, when converted to distance, is >~ the distance from the source; and multiple charges would repel each other.

Hill et al.MOP Conference, Boston, 11 July RPWS-LP measurements on E3 encounter (Shafiq et al., 2011 PSS): Max n i ~ 10 5 /cm 3 Max n e ~ 10 3 /cm 3 Inferred sub-micron dust density ~ 100/cm 3 in plume. Inferred charging timescale ~ 10 s for 30 nm dust.

Hill et al.MOP Conference, Boston, 11 July Physical displacement between (-) and (+) grains (E3) – This is in the wrong direction to be explained by the remnant corotation electric field.

Hill et al.MOP Conference, Boston, 11 July Prediction for E14 encounter on 1 October: Nanograin signature will be weak or absent, like E7, because of proximity to the source.