Ultrathin Laser Scanning Bronchoscope and Guidance System for the Peripheral Lung Future Guided Bronchoscopy in the Peripheral Lung Ultrathin Laser + Scanning-Fiber.

Slides:



Advertisements
Similar presentations
Diagnosis and Palliation for lung Cancer
Advertisements

Surgical Planning Laboratory Brigham and Women’s Hospital Boston, Massachusetts USA a teaching affiliate of Harvard Medical School User Interfaces and.
Edge Sensors for the Schwarzschild-Couder Telescopes David Hanna McGill University UCLA AGIS Meeting June 26-27, 2008.
Lecture 11. Microscopy. Optical or light microscopy involves passing visible light transmitted through or reflected from the sample through a single or.
In the past few years the usage of conformal and IMRT treatments has been increasing rapidly. These treatments employ the use of tighter margins around.
Groups: WA 2,4,5,7. History  The electron microscope was first invented by a team of German engineers headed by Max Knoll and physicist Ernst Ruska in.
1 Autonomous Registration of LiDAR Data to Single Aerial Image Takis Kasparis Nicholas S. Shorter
Three Dimensional Visual Display Systems for Virtual Environments Presented by Evan Suma Part 3.
Laser Needle Guide for the Sonic Flashlight David Wang 1,3,4, Bing Wu 2,3, George Stetten 1,2,3,4,5 1 Department of Biomedical Engineering, Carnegie Mellon.
Diagnosis and Medical Imaging Technology SNC2D. Diagnosis The interdependence of our organ systems can sometimes make it difficult to pinpoint the source.
Measurement of Light: Applications ISAT 300 Foundations of Instrumentation and Measurement D. J. Lawrence Spring 1999.
2 University of Iowa Iowa City, IA James P. Helferty 1 Anthony J. Sherbondy 1 Atilla P. Kiraly 1 Janice Z Turlington 1 Eric A. Hoffman 2 Geoffrey.
3D Augmented Reality for MRI-Guided Surgery Using Integral Videography Autostereoscopic Image Overlay Hongen Liao, Takashi Inomata, Ichiro Sakuma and Takeyoshi.
USE AND CARE OF THE MICROSCOPE LECTURE 1. MICROSCOPY u Light Microscopy: any microscope that uses visible light to observe specimens u Compound Light.
Chapter 17 Optics 17.1 Reflection and Refraction
Microscope.
Applied Anatomical Diagnostic Framework for Visualizing the Human Body in a 3-D, Immersive, Navigable and Interactive VR Environment May 4, 2012 Steven.
Digital Image Characteristic
Evaluation of a Scanned Laser Display as an Alternative Low Vision Computer Interface Conor Kleweno, Eric Seibel, Ph.D., Kyle Kloeckner, Bob Burstein,
Modeling And Visualization Of Aboriginal Rock Art in The Baiame Cave
FIBER OPTIC RS-OCT PROBE Team Members: John Acevedo Kelly Thomas Chris Miller Advisors: Dr. Patil Dr. Mahadevan-Jansen.
Smartphone Overview iPhone 4 By Anthony Poland 6 Nov 2014.
A HIGH RESOLUTION 3D TIRE AND FOOTPRINT IMPRESSION ACQUISITION DEVICE FOR FORENSICS APPLICATIONS RUWAN EGODA GAMAGE, ABHISHEK JOSHI, JIANG YU ZHENG, MIHRAN.
Test of the proposed method Introduction CCD Controller CCD Illuminator gel Filter 585nm Assembling the phantom before its irradiation. The phantom, ready.
Optical Design Work for a Laser-Fiber Scanned
CSCI-235 Micro-Computers in Science Hardware Part II.

1 Lecture 19: Motion Capture. 2 Techniques Morphing Motion Capture.
The above shows the implementation of the software used to interface with the data acquisition hardware. Inputs for each encoder and the APD detector were.
NI DAQ, Nanopositioner (Tilt mirror)  Reference: NARIONAL INSTRUMENT, “NI-DAQ 7, DAQmx C Reference Help ”, 2004 NARIONAL INSTRUMENT, “DAQ, 6534X User.
LIGHT.
What is the purpose of a wave?
Integral University EC-024 Digital Image Processing.
Virtual Bronchoscopy for 3D Pulmonary Image Assessment: Visualization and Analysis William E. Higgins, 1,2 Krishnan Ramaswamy, 1 Geoffrey McLennan, 2 Eric.
Digital Image Fundamentals. What Makes a good image? Cameras (resolution, focus, aperture), Distance from object (field of view), Illumination (intensity.
IMAGE SYNTHESIS 1 Image Synthesis Image synthesis operations create images from other images or non-image data Used when a desired image is either physically.
: Chapter 11: Three Dimensional Image Processing 1 Montri Karnjanadecha ac.th/~montri Image.
12.4 Essential Questions How is a hologram made? When does total internal reflection occur? How are optical fibers used? Using Light Copyright © McGraw-Hill.
Integrated System for Planning Peripheral Bronchoscopic Procedures Jason D. Gibbs, Michael W. Graham, Kun-Chang Yu, and William E. Higgins Penn State University.
DECREASED FLICKER SENSITIVITY WITH A SCANNED LASER DISPLAY. J.P. Kelly 1, H.L. Pryor, E.S. Viirre, T. Furness III. 1 Children's Hospital & Medical Center;
Radiology started with simple traditional x-ray technology.
Physician-Controlled System for Image-Guided Bronchoscopy W. E. Higgins, 1 R. Khare, 1 D. C. Cornish, 1 and R. Bascom 2 Penn State University, 1 College.
2 University of Iowa Iowa City, IA University of Iowa Iowa City, IA William E. Higgins 1,2 Anthony J. Sherbondy 1 James P. Helferty 1 Atilla.
We consented and enrolled 30 patients with focal lesions, suspected lung cancer and available MDCT scans. The chest scans, generated by either a Siemens.
Dr. Yingtian Pan’s Lab Unjoo Lee. About him  He is an associate Professor
IMAGE SYNTHESIS 1 Image Synthesis Image synthesis operations create images from other images or non-image data Used when a desired image is either physically.
Pill Camera Hardik Kanjariya.
Intelligent Robotics Today: Vision & Time & Space Complexity.
1 Image Overlay Guidance for Needle Insertion in CT Scanner Gabor Fichtinger*, Member, IEEE, Anton Deguet, Ken Masamune, Emese Balogh, Gregory S. Fischer,
By Prof. Stelmark. Digital Imaging In digital imaging, the latent image is stored as digital data and must be processed by the computer for viewing on.
1 Parts of the Microscope Ocular (eyepiece) Interpupillary adjustment Body Arm Coarse adjustment knob Fine focus adjustment knob Stage adjustment knobs.
Medical Imaging Lecture 4.
Outline Sample preparation Instrument setting Data acquisition Imaging software Spring 2009AFM Lab.
National Highway Institute 5-1 REV-2, JAN 2006 EQUIPMENT FACTORS AFFECTING INERTIAL PROFILER MEASUREMENTS BLOCK 5.
METHODOLOGY Nanotechnology Prof. Dr. Abdul Majid Department of Physics
Date of download: 7/8/2016 Copyright © 2016 SPIE. All rights reserved. Through-the-objective TIRF creates the evanescent field on the aqueous side of the.
Electromagnetic Navigation Diagnostic Bronchoscopy Am J Respir Crit Care Med Vol 174. pp 982–989, 2006 R4 Byunghyuk Yang.
Microscope.
Optical Non-Invasive Approaches to Diagnosis of Skin Diseases
: Chapter 11: Three Dimensional Image Processing
Section 4: Using Light Light can be used to form three-dimensional images and to transmit information in optical fibers. K What I Know W What I Want to.
Light Interactions The law of reflection states that the angle of incidence is equal to the angle of reflection. Things that are luminous can be seen because.
Instrument Considerations
Multispectral Endoscopic Imaging of Colorectal Dysplasia In Vivo
Two-dimensional and 3-dimensional optical coherence tomographic imaging of the airway, lung, and pleura  N. Hanna, BS, D. Saltzman, MD, PhD, D. Mukai,
Optical Non-Invasive Approaches to Diagnosis of Skin Diseases
A Miniature Head-Mounted Two-Photon Microscope
Measurement of abdominal aortic aneurysms with three-dimensional ultrasound imaging: Preliminary report  Daniel F. Leotta, PhD, Marla Paun, BS, Kirk W.
Virtual endobronchial ultrasound for transbronchial needle aspiration
CHAPTER 7 THE MICROSCOPE.
Presentation transcript:

Ultrathin Laser Scanning Bronchoscope and Guidance System for the Peripheral Lung Future Guided Bronchoscopy in the Peripheral Lung Ultrathin Laser + Scanning-Fiber Bronchoscope Disease diagnosis by endoscopy is exceedingly difficult when the region of interest is located within a small, complex structure in the body. Often, the physical size of the endoscope and the degree of bending required to navigate through tortuous geometries prevent the clinician from maneuvering to the desired location in vivo. As a result, several diagnostic procedures must be performed blindly or with the aid of fluoroscopy which carries with it a significant financial and time expense. We have constructed an ultrathin scanning fiber endoscope capable of imaging regions of the body that were previously inaccessible. This device uses a piezo actuator to spirally scan a single-mode fiber to direct multi-wavelength laser illumination to the image plane. The distal tip of the scanning fiber endoscope measures 1.6 mm in diameter and the highly flexible shaft is 1.3 mm in diameter. The scope has a 20:1 zoom capability to a maximum of >60º field of view (FOV) with 5 to 30 micron resolution. The goals for the ultrathin flexible bronchoscope are reaching areas of the peripheral lung and providing the earliest diagnosis of cancer to below the 8 th degree of bifurcation, where flexible bronchoscopy is limited. In addition, laser-induced autofluorescence using violet laser diodes (405 nm) will be integrated with the reflectance imaging and using this diagnostic technique to guide FNA and brush biopsy. (See references 1 & 2 for additional info.) Current bronchoscopes are only capable of reaching the airway branches within the first 5 generations. Given the high incidence of nodular masses detected on computed tomography (CT) scans, a large percentage of these nodules are beyond the bronchoscope’s reach and must be biopsied blindly using forceps, fine needle, brush, or by transthoracic needle biopsy which is significantly more invasive. Our ultrathin endoscope will allow physicians to travel further into the lung periphery where smaller cancer nodules can be visualized earlier with high-resolution CT. While current bronchoscopes can physically navigate through 5 generations of airways totaling to 2 5 or 32 separate airways, our endoscope will be able to access at least the 8 th generation airways, totaling 2 8 or 256 individual branches. Because of the large number of passageways and the added structural complexity that exists beyond 5 th generation airways, a guidance system is currently under development to assist the bronchoscopist by directing them to a predetermined region of interest using a graphical interface that displays the position of the endoscope tip on a virtual lung model. The tip of the endoscope is tracked in 6 degrees of freedom using an electromagnetic tracking system (microBIRD, Ascension Technology Corp., see reference 3). Device Design The single mode fiber is actuated by a piezo tube scanner at resonance. The fiber is scanned in a spiral pattern starting from the center. The image plane is directly illuminated by a diffraction limited gaussian beam. The FOV is adjusted by setting the voltage on the piezo scanner corresponding to the desired angle of deflection of the fiber. The single fiber carries ultraviolet and visible light from multiple lasers. 7.8 micron bar and space pattern Imaging a Dried Sheep Lung The ultrathin laser scanning bronchoscope was inserted into a dried sheep lung and red- monochrome images of 500 lines of resolution were acquired as shown. An illustrative full-color (RGB) image is shown when blue & green laser sources are combined into the singlemode optical fiber, vibrated and spiraled at 250 circles, and RGB light is projected using a commercial endoscope lens (Pentax) while backscattered RGB light is detected simultaneously with three avalanche photodiodes (Hamamatsu). 5.5 micron bar and space pattern Electromagnetic Tracking System The microBIRD tracking system includes an RF transmitter, a PCI board, two signal pre-amplifiers, and two position sensors. The transmitter generates a magnetic field within three orthogonal planes. As a result of magnetic induction, current is generated from three orthogonal coils in the sensor. From this, the precise location and orientation of the sensor can be deduced in terms of x,y,z, azimuth, elevation and roll. Ascension Technology now produces two miniature sensors measuring 1.8 mm and 1.3 mm in diameter. Guided Bronchoscopy After integrating a tracking system with a fully defined 3D map of the airways a virtual interface is needed to assist the bronchoscopist in navigating a number of tortuous paths to the desired region in the peripheral lung. At the outset of the procedure, the virtual model must be registered to the 3D space in which both the patient and tracking system subside. This ensures that both the endoscopic views obtained from the device and the virtual view generated from the tracking system and surface model are appropriately aligned. Depicted to the right is a screen shot from the user- interface that displays both endoscopic and virtual views simultaneously. An external view of the virtual model is overlayed in the top-left corner with a color indicator to represent the current position of the endoscope’s distal tip. Color-coded lines are also presented to direct the clinician down the appropriate airway and to document the “navigation history” of the procedure by virtually labeling which paths have been explored and which have not. Encapsulated Distal Tip The distal tip encasing the single mode fiber, piezo actuator, lenses and multiple light collection fibers Rigid microscanner tube and lens system Flexible shaft and collection fibers Zoom Imaging A test target is scanned and imaged using a PC workstation using Labview (National Instruments) and images are displayed at 5 Hz. Reducing the actuator voltage (<15 V) allows for zooming of 20x magnification to 5 micron resolution. References 1.Seibel EJ, Smithwick QY, Unique features of optical scanning, single fiber endoscopy, Lasers Surg Med. 2002;30(3): Johnston RS, Seibel EJ, 1.6 mm diameter scanning fiber endoscope, OSA Frontiers in Optics 2005, Tucson, AZ (accepted). 3. MicroBIRD, Ascension Technology Corp. (Burlington, VT): Financial Support: NIH/NCI R21/R33 Grant # CA110184/CA and the PENTAX Corporation, Tokyo, Japan *Eric J. Seibel Ph.D, Timothy D. Soper B.S., Richard S. Johnston M.S., Robb W. Glenny M.D. *University of Washington, Seattle, WA, USA → Presented at 11 th World Conference on Lung Cancer, Barcelona, Spain, 6 July mm Creating a Virtual Lung Model The CT scan permits clinicians to view and identify anomalous masses in the peripheral lung, but also provides a detailed picture of the patient’s anatomy. From this it is possible to extract a comprehensive map of the airway system leading from the trachea down to the nodule. Image processing techniques (ref) are applied to the digital CT scan data to segment the airways from the surrounding anatomy. Depicted ________ are front and side projection images of a binary volume of segmented airways on a sample subject. From this binary volume of data, a surface model is generated using previously developed software (ITK) to provide a realistic virtual rendering of the airways as they would appear to a clinician during bronchoscopy.