CREATION OF NEW SOIL SRM FOR METALS AND ORGANICS Stuart Nagourney 1, Stephen Long 2, Jessica Reiner 2 and Steven Wilson 3 1 Office of Quality Assurance,

Slides:



Advertisements
Similar presentations
Radiochemical Methods and Data Evaluation
Advertisements

Analyze Immediately Temperature. Hold Times IMMEDIATELY! Between minutes, as close to sample collection time as possible - note both time of collection.
Why Lab. Certification? Laboratory certification tries to insure that the laboratory is qualified and capable of analyzing the sample and obtaining quality.
NEW YORK STATE DEPT. OF HEALTH WADSWORTH CENTER
Quality is a Lousy Idea-
LABORATORY CERTIFICATION & DATA QUALITY MICHAEL W. MILLER, Ph.D. NJ-DEP Office of Quality Assurance
UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc.
1 Method Selection and Development l Initial Considerations n What does the method need to do? 3 What analyte/s need to be assayed? 3 What range or concentration.
SESSION: MANAGING CONTAMINATION North Carolina DOT’s Experience with UV Fluorescence for Measuring Petroleum Contamination in Soil Cyrus Parker, LG P.E.,
Hillcrest Community Environmental Investigation No Conflict of Interest Geo Strata is not affiliated with and does not hold contracts with the oil & gas.
Interpreting Your Lab Report & Quality Control Results
World Health Organization
Copyright © 2015, TestAmerica Laboratories, Inc. All rights reserved. 1 EPAs New MDL Procedure What it Means, Why it Works, and How to Comply Richard Burrows.
Detect Limits as Representation for a Standard VAP Rule Discussion Dawn Busalacchi Risk Assessor, DERR, Central Office VAP Rule Discussion Dawn Busalacchi.
QA/QC FOR ENVIRONMENTAL MEASUREMENT Unit 4: Module 13, Lecture 2.
Performance of current XRF instrumentation for measuring the lead content of environmental samples Kate McIntosh Wadsworth Center, NYSDOH LCC Workshop.
Multi-Agency Radiological Laboratory Analytical Protocols Manual: MARLAP Presentation to the Radiation Advisory Committee/Science Advisory Board April.
Kyiv, TRAINING WORKSHOP ON PHARMACEUTICAL QUALITY, GOOD MANUFACTURING PRACTICE & BIOEQUIVALENCE Validation of Analytical Methods Used For Bioequivalence.
Chemometrics Method comparison
QA/QC FOR ENVIRONMENTAL MEASUREMENT
Source Testing Company Accreditation and Qualified Individual Certification Programs A Status Report Peter Westlin, OAQPS, SPPD, MPG September 13, 2007.
Quality Control In Measurements Tom Colella CLAS Goldwater Environmental Lab.
A Private Laboratory Perspective on Environmental Regulation.
WWLC Standard Operating Procedures Presented by Frank Hall, Laboratory Certification Coordinator.
The following minimum specified ranges should be considered: Drug substance or a finished (drug) product 80 to 120 % of the test concentration Content.
Understanding Analytical Environmental Data. Complex and Confusing Interested in low concentrations of targets Heterogeneous samples - variable results.
Quality WHAT IS QUALITY
Bias and Errors. Some Terms Used to Describe Analytical Methods Accuracy Precision LOD RDL LOQ Selectivity Sensitivity Linearity Ruggedness.
QA/QC and QUALIFIERS LOU ANN FISHER CITY OF STILLWATER, OK
1 / 9 ASTM D19 Method Validation Procedures William Lipps Analytical & Measuring Instrument Division July, 2015.
Introduction The past, the present and the future.
Electronic Reporting Tool Software to Standardize Source Test Planning, Reporting and Assessment and Assessment Measurement Technology Workshop 12/8/2010.
Laboratory QA/QC An Overview.
BIONAD 18 Month Meeting July 7th, 2015, Inescop Premises, Elda (E) LIFE12 ENV/IT/352 Determination of trace elements in traditional dyes, naturalized dyes.
Accuracy Assessment of Sampling Designs for Surveying Heavy Metal Content in Soil Using SSSI Aihua Ma; Jinfeng Wang; Keli Zhang
ME551/GEO551 Introduction to Geology of Industrial Minerals Spring 2005 SAMPLING.
Quality Assurance How do you know your results are correct? How confident are you?
1 of 39 The EPA 7-Step DQO Process Step 3 - Identify Inputs (45 minutes) Presenter: Sebastian Tindall Day 2 DQO Training Course Module 3.
Area I Burn Pit Santa Susana Field Laboratory RCRA Facility Investigation Work Plan February 19, 2008 Laura Rainey, P.G. Senior Engineering Geologist California.
Essential Standards Used in California for the Measurement of Toxics in Ambient Air, Ozone Precursors from Automotive Emissions, and Cleaner Burning Gasoline.
Is There a Link Between Epizootic Lobster Shell Disease and Contaminants? Lawrence A. LeBlanc 1, L. Brian Perkins, and Deanna Prince 1 1 School of Marine.
BAM IDepartment for Analytical Chemistry; Reference Materials Berlin, November 2006, 1 © H. Kipphardt, BAM I.1 Characterisation of High Purity Metals as.
The analytical techniques most widespread for certification in the iron and steel industry are X-ray Fluorescence Spectrometry (XRF), Arc/Spark Optical.
Data Quality Assurance/ Quality Control. QA/QC Requirements for RECAP Submittals Data generated using rigorous analytical methods Data must be analyte.
Industrial Technology Institute Test Method Validation & Verification H.P.P.S.Somasiri Principal Research Scientist / SDD-QAD /QM Industrial Technology.
USDA-NRCS Geochemistry Research and Future Directions M.A. Wilson, R. Burt, S.W. Waltman, and M.D. Mays.
Control Charts and Trend Analysis for ISO 17025
CENTRO DE METROLOGIA QUIMICA. DEVELOPMENT OF CERTIFIED REFERENCE MATERIALS (CRMs) IN Intec.
LECTURE 13 QUALITY ASSURANCE METHOD VALIDATION
LIFE12 ENV/IT/352 Determination of trace elements in commercial dyes, crude chromophore, purified dyes and naturalized dyes Alessandro D’Ulivo BIONAD 24.
 Principles;  Moral;  Beliefs;  Moral values; and  “A set of principles of right conduct”
Copyright © 2015, TestAmerica Laboratories, Inc. All rights reserved. 1 EPAs New MDL Procedure What it Means, Why it Works, and How to Comply Richard Burrows.
1 FORMER COS COB POWER PLANT From Characterization to Redevelopment Brownfields2006 November 14, 2006.
Green Power Tools: Assessment Tools to Support Green Remediation Goals April 5,
Method Validation of VINDTA 3C (TA/DIC) Marine Scotland Science (MSS) Experience and Concerns Pamela Walsham.
Statewide Compliance Monitoring and Local Monitoring Projects
Determinations and Interpretations of FTIR Detection Limits
Quality is a Lousy Idea-
An in-depth look at trace metallic impurity determination by ICP-OES
The 2015/2016 TNI Standard and the EPA MDL Update
The Analysis of Soils and Waters in Accordance with U. S
Quality is a Lousy Idea-
Soil processes and trace metals
What it Means, Why it Works, and How to Comply
DuPont Barksdale Site Sampling and Analytical Presentation
Topics in Microbiology Quality Assurance Project Plan Essentials
Why Use Them? By: Marcy Bolek – Alloway
Quantifying the Efficiency of Different Solid Sample Digestion Methods: A Comparison of Time, Cost, and Accuracy Connie Hayes.
Environmental Laboratory Certification Program (ELCP)
NJ DWQI Testing Subcommittee
Presentation transcript:

CREATION OF NEW SOIL SRM FOR METALS AND ORGANICS Stuart Nagourney 1, Stephen Long 2, Jessica Reiner 2 and Steven Wilson 3 1 Office of Quality Assurance, New Jersey Department of Environmental Protection, Trenton, NJ NIST, Environmental Chemical Sciences Group, Chemical Sciences Division, Charleston, SC 3 United States Geological Survey, Denver Federal Center Denver, CO 80225

HOW DO WE KNOW THAT THE “MEASUREMENT SYSTEM” WORKS? 4Laboratory Certification On-site audits every 2-4 years 4Performance Testing Samples Usually not natural samples containing actual concentrations of contaminants as they exist in the environment 4Method and Sample Specific QC

METHOD QC: INSTRUMENTATION-ORIENTED 4Instrument Stability Pre-analysis Performance Checks 4Calibration Accuracy Analysis of Second Source Materials LCS 4Calibration Stability CCV 4Low Level Detection Blanks, MDLs, MRLs, LLOQ Check Samples Control limits in EPA methods are generally established by “consensus” and not by empirical data

METHOD QC: SAMPLE-ORIENTED 4Contamination Field, Trip and Lab. (Prep.) Blanks 4Sample Homogeneity Matrix Duplicates 4Method Accuracy Matrix Spikes* * This is the only indicator that directly addresses the question “are we accurately measuring how much contaminant is in the sample”

BUT THERE ARE ISSUES WITH MATRIX SPIKES 4Only 1/20 of a sample batch is spiked; how representative is that sample spike of the behavior of the entire batch? 4Spiking regime usually involves the addition of a “simple” chemical, usually as a liquid, often to a non-aqueous sample. This raises many questions, including: Equilibration of the spike How well does recovery of the spike represent the behavior of indigenous analyte?

HOW RMs CAN AUGMENT CURRENT METHOD QC 4RMs (especially SRMs produced by NIST) are routinely utilized in method QC in non- EPA method compendiums (AOAC, ASTM, NIOSH) 4NIST SRMs are routinely used to validate USEPA SW846 methods and their use has been required as part of CLP projects 4NIST Standard Reference Material® (SRM) NIST Certified Value - A value reported on an SRM certificate or certificate of analysis for which NIST has the highest confidence in its accuracy in that all known or suspected sources of bias have been fully investigated or accounted for by NIST. NIST Reference Value - A best estimate of the true value provided on a NIST certificate, certificate of analysis, or report of investigation where all known or suspected sources of bias have not been fully investigated by NIST. 4Both the Certified and Reference Values can be effective QC tools

HOW TO USE RMs TO EVALUATE USEPA METHODS 4Reference values, found in Appendices to NIST SRM COAs, often provide data obtained by USEPA Methods 4These data can be compared with the Certified Values on the COA to predict how effective digestion and/or determinate methods are in measuring concentrations of contaminants in environmental samples. 4Reference values for NIST SRM 2710A (Montana Soil):

“GENERIC” BARRIERS TO RM USE 4Despite the use of SRMs to validate methods, only Method 7199 [Cr(VI) by IC] requires QC involving RMs 4Too expensive 4Analyte concentrations do not match anticipated sample values (SRMs values too high) 4Current SRM inventory does not cover the range of all SW846 methods 4NELAC/TNI standard does not require RM use

WHY WE NEED ANOTHER SOIL SRM 4Current NIST soil SRM inventory is exclusively from Western US sources (Montana, CA, …) 4Existing SRMs do not contain all analytes of interest 4COA parameter concentrations are often much higher than that found in “typical” soil samples 4RMs are not now used for method QC for these and other reasons OBJECTIVE: TO CREATE A NEW SRM FROM EASTERN US SOURCES CONTAINING A WIDE RANGE OF INORGANIC AND ORGANIC CONTAMINANTS AT TYPICAL ENVIRONMENTAL CONCENTRATIONS NIST SRM 2706

PRIMARY PROJECT STAKEHOLDERS 4NISTGaithersburg, MD 4USGSDenver, CO 4USEPAResearch Triangle Park, NC 4NJDEPTrenton, NJ

SAMPLING SITES AND PRIMARY ANALYTE CONCENTRATIONS >New Brunswick, NJ New York >Kearny, NJ Burlington, NJ >Sayreville, NJ >Staten Island, NY SiteLocationPrimary Contaminant(s) Concentration Range (mg/kg) Paul TankBurlington, NJPCBs0.01 – 84 Mariners MarshStaten Island, NYPAHs0.04 – 10,000 Melon LeasingKearney, NJDioxins/Furans Raritan Bay SlagSayreville, NJAs, Pb, other metals3-20,000 >Burlington, NJ

PROJECT PROCESS I 4Assemble group of interested parties representing government, academia and the certified laboratory community 4Identify key contaminants of concern 4“Suitable” sampling locations have been located  Publicly-funded sites  Easy access for sampling 4Analyze retains to confirm concentrations  USEPA R2  Pace Analytical 4Select source for uncontaminated bkg. soil

PROJECT PROCESS II 4Using the results from the preliminary analyses, develop a “recipe” for mixing/blending samples from various sites to create a SRM with the desired analyte concentrations X “typical analyte concentrations” 4Samples shipped to USGS; ~ g. samples have been prepared 4USGS and NIST studies have/will confirm “bottle-to-bottle” geochemical and chemical homogeneity 4NIST analyses will provide the certified values for metals  INAA – 3 Elements  ICP-MS – 9 Elements  ID ICP-MS – 1 Element (Hg)  ICP-OES – 10 elements  XRF – 16 Elements  Other labs. will provide data to be used for reference and information values

PROJECT PROCESS III 4NIST will provide certified and appendix values for organics 4An intercomparison study will develop reference values using USEPA SW846 methods for metals and organics – participating labs. have been asked to quantify analytes below their traditional reporting levels MeasurandMethod 1Method 2Type PCBs, OCs, BDEsGC/MS HML Certified PAHsGC/MS Gaithersburg Certified Dioxins/FuransIntercomparison Study Appendix PFCsLC-MS/MS HML Reference

PARTICIPATING LABORATORIES 4 Accutest – Phil Worby 4 Alpha Laboratories – Jim Todaro 4 ALS – Ron McLeod 4 EMSL – Bill Chamberlin 4 USEPA Region 4 – Floyd Wellbourne 4 Pace Analytical – Bob Wyeth 4 TestAmerica – Mark Bruce

TARGET CONCENTRATIONS - METALS ElementICP-MS 1ICP-MS 2Units Ag< 1 mg/kg As mg/kg Be0.842 mg/kg Cd0.307 mg/kg Cr40.79 mg/kg Cu mg/kg Hg0.133 IDMS mg/kg Ni20.64 mg/kg Pb mg/kg Se mg/kg Sb mg/kg Tl0.244 mg/kg Zn mg/kg Only EPA Regulated Pollutants shown above Data will also be available for other major, transition & rare earth elements

TARGET CONCENTRATIONS - ORGANICS

ADDITIONAL CONSIDERATIONS 4VOCs not being considered due to obvious stability concerns 4Other organics, such as PFCs, will be analyzed by NIST 4If the cost of the product is an issue, secondary RMs with a link to the NIST SRM could be developed

THANK YOUs 4 Lara Phelps – USEPA 4 NELAC for funding my travel 4 All who helped with sample acquisition & distribution 4 Labs. who have and are helping with analyses 4 Dr. Bernie Wilk