© 2007 Ideal Industries www.idealindustries.com 1 of 26 Basics of Meter Safety.

Slides:



Advertisements
Similar presentations
Hazards Of Electricity
Advertisements

As a stand-alone overview of test tools.
Introducing Electricity and Electrical Safety
Introducing Electricity and Electrical Safety
Electrical Safety.
RMM Systems, LLC By Sam Rietta RMM Systems, LLC is a manufacturer's representative firm focused on providing value added sales solutions by providing.
Electrical Safety Basic Electrical Safety Rafael Coll, Environment Safety and Health Section Health& Safety Group Ext Pager: (630)
Electrical Safety 29 CFR I. Background for the Trainer:
©2003 Fluke Corporation Electrical measurement safety 1 Electrical measurement safety Understanding hidden hazards and new safety standards.
Voltage and Its Measurements
Two-mode Safety and Battery System Service
Register Digital Multimeter Usage Click Register to begin the course.
Using a Multimeter.
Landing and Taxi Lights Anti-collision Lights Navigation Lights Cockpit and Cabin Lights Instrument Panel Lights Click on a System Link to Start.
Technician License Course Chapter 9 Lesson Module 20: Electrical Safety.
PHSAUTOMOTIVESALSPHSAUTOMOTIVESALS Charging System tests & Voltage information Checking the charging system with just a volt meter.
Residential Wiring Facts
7.2.1 Student Book © 2005 Propane Education & Research CouncilPage Identifying Basic Meter and Hazard Reducing Guidelines Used in Measuring Electrical.
TEST METER OPERATION. Electrical Test Instruments Analog Or Digital Voltmeters – Measuring Potential Difference Ammeters – Measuring Current Flow – Clamp.
Charging System Service
Circuit Testers and Digital Meters
Electrical Safety 29 CFR Concerned About Electricity? How many sets of Christmas lights do you plug into one extension cord? Do you still use.
Electrical Electricity Fuses Relays Solenoids Electrical Testing
EKAS Disconnect & Reconnect UEE31307 Certificate III in Refrigeration and Air Conditioning Stage 2A Units: UEENEEPOO1B Chris Hungerford Sunday,
The Home Inspection Book: A Guide for Professionals By Marcia Darvin Spada Copyright, Thomson/South-Western, 2003, Revised, 2006.
By Carlin Bright. Electricity The flow of electrons in a conductor.
Series vs. Parallel Circuits Physics Mrs. Tobler.
Residential Construction Unit 5- Energy Efficiencies and Mechanicals Mr. Todzia.
Electrical Safety INSTRUCTOR’S NOTES:
Electrical Safety. Defective Insulation To protect you, electrical wires are insulated by a plastic.
Copyright  Business & Legal Reports, Inc. Electrical Safety 29 CFR BLR’s Safety Training Presentations.
Starter System Service Chapter 33 Page 439. Service Begins with Checking System Check the battery first –Voltage should be 12.6 and while the starter.
Electrical Safety INSTRUCTOR’S NOTES:
Electrical Power Systems
7.1.3 Student Book © 2005 Propane Education & Research CouncilPage Applying a Systems Approach to Gas Appliance Troubleshooting Troubleshooting.
Grounding, bonding, and ground fault currents
Circuit Testers and Digital Meters 4 © 2013 Pearson Higher Education, Inc. Pearson Prentice Hall - Upper Saddle River, NJ Advanced Automotive Electricity.
Copyright  Progressive Business Publications Electrical Safety.
Lesson 6 Voltage Do we need to MEASURE it? OR Do we need to DETECT it?
© 2007 Ideal Industries 1 of 36 NFPA 70e and Test Equipment NFPA 70E and Test Equipment UL
Automotive Electricity and Electronics, 3/e By James D. Halderman Copyright © 2011, 2009, 2005 Pearson Education, Inc., Upper Saddle River, NJ All.
© 2007 Ideal Industries 1 of 69 Basics of Digital Meters- Utility Applications Basics of Digital Meters Utility Applications.
© 2007 Ideal Industries 1 of 38 Meter Safety In the Workplace IDEAL’s Test and Measurement Meter Safety in the Workplace Sponsored.
Diagnosis and Troubleshooting of Automotive Electrical, Electronic, and Computer Systems, Fifth Edition By James D. Halderman © 2010 Pearson Higher Education,
PR570 POWERITE II TRAINING Dedicated to Success in Electronic Servicing for 50 Years.
1 of 25 © 2007 Ideal Industries Power Quality At the Plug IDEAL INDUSTRIES Author: Patrick Elliott Application Guide to Power Quality.
The Control of Electricity in Circuits
1 Electrical Skills Voltage and Its Measurements.
ELECTRICAL SAFETY FOR INSTRUMENTS SECTION. Electrical measurement safety Understanding hidden hazards and new safety standards.
Electrical Safety, Subpart K
Automotive Electricity and Electronics, 2/e By James D Halderman © 2009 Pearson Education, Inc. Pearson Prentice Hall - Upper Saddle River, NJ Automotive.
Electrical Testers Basic test equipment used in today’s shops may include an analog type meter, a VAT (Volt-Amp-Tester), DMM (Digital Multimeter),
HOUSE WIRING Final Review. Electricity Electricity = flow of electrons Conductor= electricity passes thru easily - Metal, water, person Insulator = restricts.
Digital Multimeter – Basic Guide
HOUSE WIRING NOTES. Electricity  Proton – positive charge  Electron – Negative charge  Electricity = flow of electrons Conductor= electricity passes.
Lab 2. Do now Answers Improperly grounded outlets can cause errors in a computer system that may not be immediately apparent from internal diagnostics.
Electrical Safety Basic Electrical Safety. Electrical Safety  Course not designed to teach you to work on electrical equipment. Basic Electrical Safety.
Office and Home Electrical Safety
Using a Multimeter.
Digital Multimeter Introduction
Basic Electrical Safety
WORKSHOP PRACTICE WEEK-5 OBJECTIVE OF LAB-5 Introduction to digital multimeter and its measuring method. To be familiar with the connections of.
HOME ELECTRICAL SAFETY
Personal Protective Equipment
ELECTRICAL POWER-II Electrical engineering sixth semester
EET 323 – Electrical System Design Lecture 4: Wiring Devices
Basic Electrical Safety
Basic Electrical Safety
Presentation transcript:

© 2007 Ideal Industries 1 of 26 Basics of Meter Safety

© 2007 Ideal Industries 2 of 26 Basics of Meter Safety Digital Multimeter Safety

© 2007 Ideal Industries 3 of 26 Basics of Meter Safety Ideal Test and Measurement Goal –Awareness of the potential Measurement Hazards –Learn How to minimize and avoid Electrical measurement hazards –Understanding of UL61010 (IEC ) Over-Voltage Categories Safety Practices with Electrical Testers

© 2007 Ideal Industries 4 of 26 Basics of Meter Safety Why should we be Concerned? An electrician troubleshooting a live 480V motor control center receives serious second- and third-degree burns from an electric arc. The cause? –Meter was incorrectly switched on his multimeter to read resistance instead of voltage.

© 2007 Ideal Industries 5 of 26 Basics of Meter Safety Why should we be Concerned? Two electricians are severely burned — one fatally — while testing for voltage in a motor starter. One held the multimeter while the other applied the meter's probes to energized terminals. One electrician's movement caused one test lead banana plug (energized from the circuit under test) to pull loose from the multimeter jack. –The plug made contact with the starter's grounded metal enclosure and initiated a high- energy arc.

© 2007 Ideal Industries 6 of 26 Basics of Meter Safety Why should we be Concerned? An electrician is sent spiraling from a steel tower while checking a circuit with a multimeter. He was using a meter rated for 1000V to verify a 15kV circuit believed dead. He didn't know the circuit was hot. Therefore, when he applied the multimeter, a phase-to-ground fault occurred. –Fortunately, his safety harness stopped his fall and coworkers on the ground rescued him.

© 2007 Ideal Industries 7 of 26 Basics of Meter Safety Common Mistakes Made Test Leads in the Current input ports and user mistakenly makes an AC or DC Voltage –In this example there were two errors made by the end user. AC voltage measurement with the Test leads in the current input. Improper fuse had been used in the meter from a past error.

© 2007 Ideal Industries 8 of 26 Basics of Meter Safety Common Mistakes Made Make sure not to exceed the Max input of your meter. –Most common mistake is to measure voltage with the leads in the current inputs. –Current inputs are very low resistance. It appears as a short circuit to Voltage. –For current input protection most DMMs’ are Fused. –Look for high energy fusing. Current Protection Fuse Current Measurements with Meters Ideal series give a probe error message and High audible warning if this mistake is made.

© 2007 Ideal Industries 9 of 26 Basics of Meter Safety Common Mistakes Made Function Switch in wrong function for attempted measurement –Example: AC or DC voltage measurement with function switch in Ohms. –Most Ideal meters are Overload Protected and the protected levels are listed in the operation manual. Ideal series will give you a Hi-V and audible warning if you make this Mistake

© 2007 Ideal Industries 10 of 26 Basics of Meter Safety Common Mistakes Made Using a meter in an area above its stated rating –Example: 2,300 voltage measurement with an instrument rated for Low Voltage (600V AC/DC.) –Overload Protected can not protect you from this Kind of mistake. –Most Overload protected is rated based on instruments highest voltage measurement rating. There are Bold Electricians and Old electricians, but not many Bold-Old ones

© 2007 Ideal Industries 11 of 26 Basics of Meter Safety Common Safety Hazards High Voltage transients from lightning, large inductive loads being switched on and off, or capacitive discharge. –Select meter with the proper UL/IEC Category rating for the environment that user is going to be working in.

© 2007 Ideal Industries 12 of 26 Basics of Meter Safety Safety Practices Visually inspect the test tool. –Check for any contaminate on the test leads, tester case, holsters, and accessories. –Never use testers that have signs of cracked cases, or loose components. – Never use a tester in an environment that is beyond the capabilities described in the specifications –Use manufactures recommended replacement components, like leads and fuses.

© 2007 Ideal Industries 13 of 26 Basics of Meter Safety Safety Practices Visually inspect Test Leads –Proper Category rating –Double insulation –Shrouded connectors –Finger guards –Insulation not damaged: not melted, cut, cracked, stretched –Connectors: no insulation pulled away from end connectors –Probe tips: not loose or broken off (too short)

© 2007 Ideal Industries 14 of 26 Basics of Meter Safety Before you get Started Quick Check of your Test Tool –Digital Multimeter or Digital Clamp meter –Check the Test Leads –Place the DMM in the lowest resistance range and short the Test Leads –Move the test lead at in input of the meter at the ankle of the leads. Watch that the resistance is less than 0.5 ohms. Do the same at the leads grip and tips. If at any time during this test the resistance exceeds 0.5 ohms the leads my need to be replaced. It is also a good Idea to check the DC voltage and Ac voltage with a known source before beginning the day. –This doesn't negate the “Three point measurement” method. If the unit has current, check the Fuse, and remember to replace with only the manufacturer recommended replacement part. Remember to always be aware of your battery usage. Digital instruments will become erratic or can give improper readings once the power drops below normal operating levels

© 2007 Ideal Industries 15 of 26 Basics of Meter Safety Before you get Started Whenever possible, work on de-energized circuits. Use well maintained tools and appropriate safety gear –Follow New NFPA 70E Guidelines Safety glasses, insulated tools, insulating gloves, flash suits, insulating mats, etc. Follow proper safety precautions and Lockout Tag out practices. Never Work alone when making measurements on live circuits. Always do a performance test on your tester before making a measurement on an unknown circuit. –Use the 3 point method. Measure a known test point, Make the unknown measurement, then back to the known test measurement. –Change battery when indicated –Check test leads regularly

© 2007 Ideal Industries 16 of 26 Basics of Meter Safety Know your tester Packaging –Material, Insulation rating Environmental rating, Splash proof or not. Features –MIN/MAX, Peak, Hold Measurement Functions –AC Volts, DC Volts Capacitance, etc –Measurement range and Maximum input –Input protection. Safety –CATegory rating, UL, CE

© 2007 Ideal Industries 17 of 26 Basics of Meter Safety Certified Devices and Equipment Look for tools that are Certificated by an independent lab, –UL, IEC, CSA. Pay close attention to the safety rating on the equipment. –Never use equipment that is not properly rated Never use accessories that are not recommended or rated for your tester or environment. IEC Cat ratings The New UL 61010B standard incorporates features of the IEC standard. This standard has improved safety benefits over the old UL 1244 standard

© 2007 Ideal Industries 18 of 26 Basics of Meter Safety IEC Category Ratings IEC defines as four Categories: –CAT IV “Origin of installation”, –CAT III Distribution Level, –CAT II Local level, –CAT I Signal Level, If a lighting strike was to hit your electrical service a certain amount of energy or impulse would travel and be dissipated by the electrical service. The closer to the source of the impulse the Higher available fault current.

© 2007 Ideal Industries 19 of 26 Basics of Meter Safety International Electro-technical Commission IEC requires an instrument provide protection against “over- voltage impulse transients” - voltage spikes. IEC is the basis for: –ANSI/ISA-S (US) –CAN C22.2 No (CAN) –EN :1993 (EUR) UL 61010B standard incorporates features of the IEC standard, –This standard has improved safety benefits over the old UL 1244 standard and the old IEC 348

© 2007 Ideal Industries 20 of 26 Basics of Meter Safety Impulse Fault –The closer to the source of the impulse the Higher available fault current. –If an instrument was to be hit by an impulse and a fault condition was to occur the Available energy “Fuel” the Fault. –Lets use the example of water or water pressure. –The larger the pipe the Greater the potential –The closer to the supply the Greater the potential Fireman with a 4 inch hose Faucet with ½ inch supply line

© 2007 Ideal Industries 21 of 26 Basics of Meter Safety Category rating, Voltage mean What CAT III-600V or CAT II- 1000V? The greater the source impedance, the lower the Category: CAT III-600V: –6 kV impulse –2 Ohm test source CAT II-1000V: –6 kV impulse –12 Ohm test source A CAT III-600V 6kV test impulse has 6 times the current of a CAT II-1000V 6kV test impulse! Voltage rating by itself can be misleading. –CAT III-1000V (8kV transient) is safer than CAT III-600V (6kV transient) –But CAT III-600V is safer than CAT II- 1000V

© 2007 Ideal Industries 22 of 26 Basics of Meter Safety CAT IV Outside and service entrance Service drop from pole to building Run between meter and panel Overhead line to detached building Underground line to well pump Equipment of over-voltage category IV is for use at the origin of the installation (utility service).

© 2007 Ideal Industries 23 of 26 Basics of Meter Safety CAT III Permanently installed loads: motors, lighting systems, drives, load centers. Typically separated from utility service by at least a single level of transformer isolation. Does not include receptacle plug-in loads, except in the case of heavy appliance outlets with “short” connections to service entrance Category III is Premises wiring: “mains”circuits, i.e., bus and feeders and distribution panels

© 2007 Ideal Industries 24 of 26 Basics of Meter Safety CAT II Examples of such equipment are appliances, portable tools and other household and similar loads All outlets at more than 10 m (30 ft) from Category III All outlets at more than 20 m (60 ft) from Category IV Category II: Loads that plug in at receptacle outlet

© 2007 Ideal Industries 25 of 26 Basics of Meter Safety CAT I Examples are protected electronic circuits. A copier that has an internal step-up transformer and 1000Vdc is still a CAT I- 1000V machine, because the current levels are so low. Equipment in which measures are taken to limit transient over-voltages to an appropriately low level.

© 2007 Ideal Industries 26 of 26 Basics of Meter Safety Thank you You may want to refer to the Following Papers Case histories come from an IEEE paper entitled “Personnel Safety and Plant Reliability Considerations in the Selection and Use of Voltage Test Instruments,” ( IEEE Transactions on Industry Applications, Vol. 33, No. 2, March/April 1997),written by H. Landis Floyd II and Brian J. Nenninger. ANSI C IEEE Recommended Practice on Surge Voltages IEC UL 3111 Part II NFPA Code 70E Ideal Industries, Inc Test and Measurement Division 1 Becker Place Sycamore, Il (800)