BIX In-Building Cross Connect system BIX Installation Guide ELCM 254 Updated December 2013 gmail.com 1 Most of the images and some text for.

Slides:



Advertisements
Similar presentations
Levolors New Size-In-Store Blind Cutting Machine.
Advertisements

Interior Wall and Ceiling Finish
How to Make a Straight-through Cable
Crimping Get the pinouts for the desired connector and application. 2.Identify the proper connector and the associated pins for your application.
Cabling UTP AND FIBER CABLING. Structured Cabling Infrastructure Mounted and permanent Allows patching Comfort that infrastructure is OK Components: Information.
HOW TO MAKE UTP CAT-5/5e CABLE
Building a T568B Network Cable Examples of good and bad cables Identification of components Critical areas of cable.
+ Straight-Through Cable Construction Lab 4. + Data Transmission In data transmission system, the transmission medium is the physical path between transmitter.
Workshop Safety Lee McNeil, mentor of the Skagit Valley (WA) SeaTech 4-H ROV teams, developed the following placards, which he attaches to the tools in.
Installation. Indoor Unit Installation Typical Installation.
Click on this image to open the full PDF document.
Copyright 2008 Kenneth M. Chipps Ph.D. How to Terminate a Corning Unicam Connector Last Update
Typical Walk-in Closet with elfa® décor
FHM TRAINING TOOLS This training presentation is part of FHM’s commitment to creating and keeping safe workplaces. Be sure to check out all the training.
System X 3500 Fan Cage Removal Here are some basic steps and helpful hints.
Physical Transmission Media 8 5/9/ Modified by: Brierley.
Hands On: Cutting and Connectorizing UTP Chapter 3a Panko’s Business Data Networks and Telecommunications, 6 th edition Copyright 2007 Prentice-Hall May.
We Design Innovative Bus Interiors LED Retrofit Systems Designed ForPretoria Hadley/Transmatic L-20 and Hadley/Transmatic L-20 Fluorescent Aisle Lighting.
2008 Cadillac CTS With Original Antenna
Making A Motor Exploring the Magic of Electricity.
Connecting crank and pivot shaft assemblies. Press fits, or interference fits are sometimes used in manufacturing to reduce manufacturing costs or liabilities.
111 © 2002, Cisco Systems, Inc. All rights reserved. Trim out phase steps Cutting cables to length Labeling cables Dressing cables Terminating cables Installing.
Installation. Indoor Unit Installation Typical Installation.
Electrical Connections and Wire Harness Assembly
1 Fiber Optics FIBER OPTIC PATCH PANELS. 2 Fiber Optics Just like our copper cable plant the fiber cable plant incorporates many of the same hardware.
How to Make a Simple DC Motor
Cisco – Semester 1 – Chapter 9 Preview Review. Behavioral Objectives Document all work –Do it as work proceeds –Same as chapter 8 guidelines –Don’t forget.
1 Telecom Cabling Ladder racks systems and relay racks Ladder racks systems and relay racks.
1 PBX installation considerations BASIC TELECOMMUNICATIONS.
1 66 blocks are prevalent in the telecommunications industry Today they are used primarily for phone applications only 66 blocks are prevalent in the telecommunications.
How to Build an Ethernet Cable ASIF ISLAM LTEC 4550 University of North Texas.
1 Business Development (Service).  Select location for Reflector Installation with clear view of Satellite (Line Of Sight)  There should not be.
Tools of the Trade Presentation #5 ©PRGodin gmail.com Updated Dec 2013.
Chap 9 Structure Cabling Project Andres, Wen-Yuan Liao Department of Computer Science and Engineering De Lin Institute of Technology
The Saigon CTT Semester 1 CHAPTER 9 Le Chi Trung.
NETWORK CABLING Chapter 2
Installation. Indoor Unit Installation Typical Installation.
Batteries The purpose of the battery is to act as a reservoir for storing electricity.
Crossover Cable Construction
Module 3: Networking Media Safe Handling and User of a Multimeter Voltage Measurement Resistance Measurement Series Circuits 3.1.9a.
Cabling Project. Your first responsibility, as the network designer, will be to have your client specify, in writing, the desired outcome of the project.
Making and Testing Cat 5 Cables. EIA/TIA-568A and 568B Straight Through and Crossover Cables EIA/TIA-568 Commercial Building Telecommunications Wiring.
CABLING SYSTEM INSTALLATION. Installation Quality The quality of installation is the most serious problem in implementation of the telecommunications.
Project On Ethernet Cable Building & Video Recording James Maclean & Stephen Craig.
Design Studies 20 ‘Show Off’ Project How to make a computer monitor In Google Sketchup By: Liam Jack.
Network Anatomy By: Roland J. Boutte. Ethernet Cable cable used to connect computing devices together directly. two hosts or two switches to each other.
COPPER AND FIBER REVIEW
Chapter 5a. 5a-2 Single Twisted Pair Jacket Four pairs (each pair is twisted) are enclosed in a jacket. Copyright 2011 Pearson Education, Inc. Publishing.
Network Tools and Cabling. Network Tools RJ means "Registered Jack" This is a plastic connector that looks like a large telephone-style connector. Used.
Wildland Fire Information and Technology Making and Testing Cat 5 Cables.
Investigation into the Mounting of the 3M BRCP Splitter Blocks in the Whisper Cabinet 24 October 2008.
© ExplorNet’s Centers for Quality Teaching and Learning 1 Use appropriate tools for network cabling and connections. Objective – 2%
Presentation created by T. Trimpe Presentation was developed for use with DNA Jewelry lesson at
How to wire Ethernet Cables. Tools Required CAT 5 Cable - bulk Category 5, cable RJ45 Ends Crimper for RJ45 Wire Cutters - to cut and strip the cable.
VIEW SERIES with Sliding Door
CREATING A 568A, 568B, OR CROSSOVER CABLE Creator:Dennis Groseclose
How to wire Ethernet Cables
DNA Keychains.
S12700 CSS Card Clustering 1 Components and Tools 2 Installing Cards
Hands On: Cutting and Connectorizing UTP
BIX In-Building Cross Connect system
UH-60 Blackhawk A/C INSPECTION JUMP COMMANDS TIME WARNINGS
Hands On: Cutting and Connectorizing UTP
Tools of the Trade Presentation #5 ©PRGodin gmail.com
(Preliminary) WIYN 0.9 Meter Collimation Procedure
Hands On: Cutting and Connectorizing UTP
Reader Swap out Guide.
Presentation transcript:

BIX In-Building Cross Connect system BIX Installation Guide ELCM 254 Updated December 2013 gmail.com 1 Most of the images and some text for this presentation comes from IBDN’s BIX IDC Wall Mount System (Installation and Maintenance) Document Number: IBDN-IG-BIXWMS-9609

BIX Components BIX-10A (250 Pair Mount) BIX-10C (50 Pair Mount) BIX-16A Punch Tool BIX-1A4 Block BIX-1A Block BIX-03 to -08 Designation Labels BIX-20A Designation Strip BIX-19A “D” Ring Images: 2

Image from: (user submission) Basic BIX Installation, with cross- connections 3

4 BIX Punch (or Impact) Tool

The backboard for mounting the blocks is typically ¾ inch quality plywood, painted white. The correct alignment of the completed BIX installation depends upon the accuracy of the horizontal and vertical placement of the first mount. Get the first one mounted correctly. 5

6 Mounting sequence

7

8 Procedure: First Steps

9

10

11

12

Distribution Ring (D-Ring) Installation 13

14

15

Cable Routing The Bend Radius is 4x the cable diameter for 4pr and 10 times for 25pr 16

Cable termination is always done from left to right The first pair is always on the left side of the connector. The first termination on the block will be to the building cable. The terminal block will be flipped and placed in its permanent position after the termination. Position the block so that the word “BIX” can be read on the top of the block after it is flipped and in its permanent position. 17

To latch the connector block insert one end in its locked position, then push the other through the latch. Do not push both ends through the latches at the same time. To remove the block release one latch only and pull on the connector block. 18

Place a cable tie in the connector block. Remove cable sheath to approximately 7in/180mm from the cable tie. Loosely fasten the cable with the cable bundle. Close the connector block tie and trim off all excess. 19

20

Insert the connector block into the mount. It should be orientated to allow it to be flipped after the termination. After the flip the word “BIX” must appear at the top and the cable bundle must be toward the center of the dual block mount. 21

Starting from the left, insert the wire pairs into the connector block. First pair should be white/blue, blue/white. Maintain a minimum amount of untwisting. Use the pair splitter on the block. Maintain consistency in length and amount of untwist. Keep the wire perpendicular for the first 1/2cm otherwise the tool will not function properly. 22

Punch down each wire ensuring the tool is horizontal and the cutting blade is on the proper side. The wire on both sides should fit through the wire slot on the tool. 23

After completion flip the connector block. Dress the cables. 24

Completed block pair. Note both cable bundles are toward the center of the two blocks. 25

Prepare the designation strip and label. Use the proper color label. 26

After labeling attach the designation strip and label to the mount. 27

Cross-connections Insert the cross connect wire through the slot in the mount and point the end of the wire toward the label. 28

Terminate the cross connect wires. 29

Route the cross connect wire to the appropriate block, using the distribution rings. Add 3in/75mm of slack to the cross connect wires (approximately the width of a hand) 30

Removal of cross-connect wire Pull the wire outward and away from the connector block. Unwanted cross-connect wires should be removed and discarded. Inspect the block for damage or jacket remnants before re-use. END 31 Wire removal tool (Hook or Spludger) Image: Paladin

Review Proper installation of a Block: 32 Permanent cables under the blocks Wire bundles toward each other (under the label) Cross-Connect wires have slack END of Presentation