MAPS for a “Tera-Pixel” ECAL at the International Linear Collider J.P. Crooks Y. Mikami, O. Miller, V. Rajovic, N.K. Watson, J.A. Wilson University of.

Slides:



Advertisements
Similar presentations
Monolithic Active Pixel Sensor for aTera-Pixel ECAL at the ILC J.P. Crooks Y. Mikami, O. Miller, V. Rajovic, N.K. Watson, J.A. Wilson University of Birmingham.
Advertisements

TPAC: A 0.18 Micron MAPS for Digital Electromagnetic Calorimetry at the ILC J.A. Ballin b, R.E. Coath c *, J.P. Crooks c, P.D. Dauncey b, A.-M. Magnan.
A MAPS-based readout of an electromagnetic calorimeter for the ILC Nigel Watson (Birmingham Univ.) Motivation Physics simulations Sensor simulations Testing.
J.A. Ballin, P.D. Dauncey, A.-M. Magnan, M. Noy
Rutherford Appleton Laboratory Particle Physics Department G. Villani CALICE MAPS Prague TWEPP TWEPP-07 Topical Workshop on Electronics for Particle.
6 Mar 2002Readout electronics1 Back to the drawing board Paul Dauncey Imperial College Outline: Real system New VFE chip A simple system Some questions.
23 Jul 2008Paul Dauncey1 TPAC 1.1 vs TPAC2.0 vs TPAC2.1 Paul Dauncey.
M. Szelezniak1PXL Sensor and RDO review – 06/23/2010 STAR PXL Sensors Overview.
Development of an Active Pixel Sensor Vertex Detector H. Matis, F. Bieser, G. Rai, F. Retiere, S. Wurzel, H. Wieman, E. Yamamato, LBNL S. Kleinfelder,
Jaap Velthuis, University of Bristol SPiDeR SPiDeR (Silicon Pixel Detector Research) at EUDET Telescope Sensor overview with lab results –TPAC –FORTIS.
Anne-Marie Magnan Imperial College London A MAPS-based digital Electromagnetic Calorimeter for the ILC on behalf of the MAPS group: Y. Mikami, N.K. Watson,
1 Konstantin Stefanov, CCLRC Rutherford Appleton Laboratory 1 ECFA 2006, Valencia 1 MAPS-based ECAL Option for ILC ECFA 2006, Valencia, Spain Konstantin.
Terra-Pixel APS for CALICE Progress meeting 10 th Nov 2005 Jamie Crooks, Microelectronics/RAL.
10 Nov 2004Paul Dauncey1 MAPS for an ILC Si-W ECAL Paul Dauncey Imperial College London.
Thursday, May 10th, 2007 Calice Collaboration meeting --- A.-M. Magnan --- IC London 1 Progress Report on the MAPS ECAL R&D on behalf of the MAPS group:
1 The MAPS ECAL ECFA-2008; Warsaw, 11 th June 2008 John Wilson (University of Birmingham) On behalf of the CALICE MAPS group: J.P.Crooks, M.M.Stanitzki,
MAPS ECAL Nigel Watson Birmingham University  Overview  Testing  Summary For the CALICE MAPS group J.P.Crooks, M.M.Stanitzki, K.D.Stefanov, R.Turchetta,
Tera-Pixel APS for CALICE Progress meeting, 17 th September 2007 Jamie Crooks, Microelectronics/RAL.
1 Instrumentation DepartmentMicroelectronics Design GroupR. Turchetta 3 April 2003 International ECFA/DESY Workshop Amsterdam, 1-4 April 2003 CMOS Monolithic.
Rutherford Appleton Laboratory Particle Physics Department A Novel CMOS Monolithic Active Pixel Sensor with Analog Signal Processing and 100% Fill factor.
SPiDeR  First beam test results of the FORTIS sensor FORTIS 4T MAPS Deep PWell Testbeam results CHERWELL Summary J.J. Velthuis.
3D Vertex Detector Status The requirement for complex functionality in a small pixel led us to investigate vertically integrated (3D) processes. Developed.
ASIC1  ASIC2 Things still to learn from ASIC1 Options for ASIC 1.01  1.1  1.2 Logic test structure for ASIC2.
Development of Advanced MAPS for Scientific Applications
First Results from Cherwell, a CMOS sensor for Particle Physics By James Mylroie-Smith
1 Nick Sinev LCWS08, University of Illinois at Chicago November 18, 2008 Status of the Chronopixel project J. E. Brau, N. B. Sinev, D. M. Strom University.
Monolithic Pixels R&D at LBNL Devis Contarato Lawrence Berkeley National Laboratory International Linear Collider Workshop, LCWS 2007 DESY Hamburg, May.
TPAC progress Jamie C 29 th July TPAC1.1 Status Submitted 17 th –Some minor DRC errors found at foundry –Corrected/waived Re-Submitted 23 rd July.
SPiDeR  SPIDER DECAL SPIDER Digital calorimetry TPAC –Deep Pwell DECAL Future beam tests Wishlist J.J. Velthuis for the.
7 Nov 2007Paul Dauncey1 Test results from Imperial Basic tests Source tests Firmware status Jamie Ballin, Paul Dauncey, Anne-Marie Magnan, Matt Noy Imperial.
TPAC1.1 Progress JC: Dec 8 th. Laser No further investigation of odd scans on V1.1 De-ionizing filter needs replacing – On order… Bulb needs replacing.
Fully depleted MAPS: Pegasus and MIMOSA 33 Maciej Kachel, Wojciech Duliński PICSEL group, IPHC Strasbourg 1 For low energy X-ray applications.
Development of an ASIC for reading out CCDS at the vertex detector of the International Linear Collider Presenter: Peter Murray ASIC Design Group Science.
LEPSI ir e s MIMOSA 13 Minimum Ionising particle Metal Oxyde Semi-conductor Active pixel sensor GSI Meeting, Darmstadt Sébastien HEINI 10/03/2005.
Tera-Pixel APS for CALICE Jamie Crooks, Microelectronics/RAL SRAM Column Concept.
First tests of CHERWELL, a Monolithic Active Pixel Sensor. A CMOS Image Sensor (CIS) using 180 nm technology James Mylroie-Smith Queen Mary, University.
18 Sep 2008Paul Dauncey1 The UK MAPS/DECAL Project Paul Dauncey for the CALICE-UK MAPS group.
J. Crooks STFC Rutherford Appleton Laboratory
UK Activities on pixels. Adrian Bevan 1, Jamie Crooks 2, Andrew Lintern 2, Andy Nichols 2, Marcel Stanitzki 2, Renato Turchetta 2, Fergus Wilson 2. 1 Queen.
Advanced Pixel Architectures for Scientific Image Sensors Rebecca Coath, Jamie Crooks, Adam Godbeer, Matthew Wilson, Renato Turchetta CMOS Sensor Design.
26 Apr 2009Paul Dauncey1 Digital ECAL: Lecture 2 Paul Dauncey Imperial College London.
L.Royer– Calice LLR – Feb Laurent Royer, J. Bonnard, S. Manen, P. Gay LPC Clermont-Ferrand R&D pole MicRhAu dedicated to High.
Rutherford Appleton Laboratory Particle Physics Department G. Villani CALICE MAPS Prague September TWEPP-07 Topical Workshop on Electronics for.
The development of the readout ASIC for the pair-monitor with SOI technology ~irradiation test~ Yutaro Sato Tohoku Univ. 29 th Mar  Introduction.
Radiation hardness of Monolithic Active Pixel Sensors (MAPS)
26 Apr 2009Paul Dauncey1 Digital ECAL: Lecture 3 Paul Dauncey, Imperial College London.
CMOS MAPS with pixel level sparsification and time stamping capabilities for applications at the ILC Gianluca Traversi 1,2
Rutherford Appleton Laboratory Particle Physics Department G. Villani CALICE MAPS Siena October th Topical Seminar on Innovative Particle and.
A MAPS-based readout for a Tera-Pixel electromagnetic calorimeter at the ILC Marcel Stanitzki STFC-Rutherford Appleton Laboratory Y. Mikami, O. Miller,
Custom mechanical sensor support (left and below) allows up to six sensors to be stacked at precise positions relative to each other in beam The e+e- international.
-1-CERN (11/24/2010)P. Valerio Noise performances of MAPS and Hybrid Detector technology Pierpaolo Valerio.
11 October 2002Paul Dauncey - CDR Introduction1 CDR Introduction and Overview Paul Dauncey Imperial College London.
4 Jun 2008Paul Dauncey1 Crosstalk and laser results Paul Dauncey, Anne-Marie Magnan, Matt Noy.
Terra-Pixel APS for CALICE Progress meeting 10 th Nov 2005 Jamie Crooks, Microelectronics/RAL.
Eleuterio SpiritiILC Vertex Workshop, April On pixel sparsification architecture in 130nm STM technology ILC Vertex Workshop April 2008 Villa.
MAPS ECAL Nigel Watson Birmingham University  Technical Status  Future Plans  Summary For the CALICE MAPS group J.P.Crooks, M.M.Stanitzki, K.D.Stefanov,
Monolithic and Vertically Integrated Pixel Detectors, CERN, 25 th November 2008 CMOS Monolithic Active Pixel Sensors R. Turchetta CMOS Sensor Design Group.
5 May 2006Paul Dauncey1 The ILC, CALICE and the ECAL Paul Dauncey Imperial College London.
Hybrid CMOS strip detectors J. Dopke for the ATLAS strip CMOS group UK community meeting on CMOS sensors for particle tracking , Cosenors House,
9 Sep 2008Paul Dauncey1 MAPS/DECAL Status Paul Dauncey for the CALICE-UK MAPS group.
Andrei Nomerotski 1 Andrei Nomerotski, University of Oxford for LCFI collaboration LCWS2008, 17 November 2008 Column Parallel CCD and Raw Charge Storage.
Advanced Monolithic Active Pixel Sensors with full CMOS capability for tracking, vertexing and calorimetry Marcel Stanitzki STFC-Rutherford Appleton Laboratory.
SPiDeR  Status of SPIDER Status/Funding Sensor overview with first results –TPAC –FORTIS –CHERWELL Beam test 09 Future.
Marcel Stanitzki 1 The MAPS ECAL Status and prospects Fermilab 10/Apr/2007 Y. Mikami, O. Miller, V. Rajovic, N.K. Watson, J.A. Wilson University of Birmingham.
for the SPiDeR collaboration (slides from M. Stanitski, Pixel2010)
TPAC1.0 Jamie Crooks.
Update on DECAL studies for future experiments
First Testbeam results
TPAC1.1 progress Jamie C 4th June 2008.
Presentation transcript:

MAPS for a “Tera-Pixel” ECAL at the International Linear Collider J.P. Crooks Y. Mikami, O. Miller, V. Rajovic, N.K. Watson, J.A. Wilson University of Birmingham J.A. Ballin, P.D. Dauncey, A.-M. Magnan, M. Noy Imperial College London J.P. Crooks, B. Levin, M.Lynch, M. Stanitzki, K.D. Stefanov, R. Turchetta, M. Tyndel, E.G. Villani STFC-Rutherford Appleton Laboratory

SiW ECAL for ILC 30 layers silicon & tungsten Prove Monolithic Active Pixel Sensor (MAPS) as a viable solution for the silicon! Machine operation 189ns min bunch spacing 199ms between bunch trains for readout Sensor Specification Sensitive to MIP signal Binary readout from 50micron pixels Store timestamp & location of “hits” Noise rate Design to hold data for 8k bunch crossings before readout Introduction 2625 bunches

INMAPS Process Additional module: Deep P-Well –Developed by foundry for this project –Added beneath all active circuits in the pixel –Should reflect charge, preventing unwanted loss in charge collection efficiency Device simulations show conservation of charge Test chip processing variants –Sample parts were manufactured with/without deep p-well for comparison Standard 0.18 micron CMOS 6 metal layers Analog & Digital 1.8v 12 micron epitaxial layer

Device Simulations TCAD model of 3x3 pixels Charge injected in 21 reference points Response at each diode in 3x3 pixels recorded Charge collected Collection time (to 90%) Profile mirrored to create full 150x150um terrain F B Simulation points Pixel profiles

preShape Gain 94uV/e Noise 23e- Power 8.9uW 150ns “hit” pulse wired to row logic Shaped pulses return to baseline Pixel Architectures preSample Gain 440uV/e Noise 22e- Power 9.7uW 150ns “hit” pulse wired to row logic Per-pixel self- reset logic

preShape Pixel 4 diodes 160 transistors 27 unit capacitors Configuration SRAM –Mask –Comparator trim (4 bits) 2 variants: subtle changes to capacitors Pixel Layouts preSample Pixel 4 diodes 189 transistors 34 unit capacitors 1 resistor (4Mohm) Configuration SRAM –Mask –Comparator trim (4 bits) 2 variants: subtle changes to capacitors Deep p-well Circuit N-Wells Diodes

8.2 million transistors pixels; 50 microns; 4 variants Sensitive area 79.4mm2 –of which 11.1% “dead” (logic) Test Chip Architecture Four columns of logic + SRAM –Logic columns serve 42 pixels –Record hit locations & timestamps –Local SRAM Data readout –Slow (<5Mhz) –Current sense amplifiers –Column multiplex –30 bit parallel data output

Sensor Testing: Overview Test pixels preSample pixel variant Analog output nodes Fe55 stimulus IR laser stimulus Single pixel in array Per pixel masks Fe55 stimulus Laser Stimulus Full pixel array preShape (quad0/1) Pedestals & trim adjustment Gain uniformity Crosstalk Beam test quad0 quad1

Test pixels: Laser Stimulus 1064nm pulsed laser 2x2um square area of illumination at focal point Simulates point-charge deposit in pixel Illuminate back of sensor Silicon is ~transparent at this λ Adjust focus to hit the EPI layer Account for refractive index! Scan XY position to 1um accuracy Test pixels & laser run asynchronously Oscilloscope triggered by laser sync pulse shows analog response from test pixel Measure (histogram) Amplitude Time delay = (System Delay) + (charge collection) Bulk silicon wafer EPI Pixel Circuits

Test pixels: Laser Stimulus First look (Nov ‘07) without / with DPW 4x4um spot, 5um steps Poor focussing! Recent scans Optimised Focus 2x2um spot, 2um steps Automated laser profile of full test pixel area begins… With/without DPW Different depths epi

Delay (ns) 78ns 17um 90ns Timing measurement (30mV threshold) Test pixels: Laser Stimulus TCAD Simulation t(Q=90%) values

Evaluating single pixel performance Record #hits for a given threshold setting 1 threshold unit ~0.4mV Low thresholds  noise hits Max #hits defined by memory limit (=19 per row) Comparator is edge-triggered o Very small or negative thresholds don’t trigger comparator Signal should generate hits at higher thresholds than the noise No hits expected for very high thresholds Binary readout from pixels in the array Can mask individual pixels Evaluated with a threshold scan… Single active pixel with/without laser firing Number of hits

Single Pixel in Array: Laser/Alignment Use laser for alignment Back of sensor has no features for orientation Mounting is not necessarily square to <1um Laser position scans in X & Y Threshold scan technique Estimate signal magnitude from drop-off By eye By function fit?

Single Pixel in Array: Laser Stimulus Amplitude results With/without deep pwell Compare Simulations “GDS” Measurements “Real” F B Simulation points Pixel profiles

Single Pixel in Array: 55 Fe Source 55 Fe gives 5.9keV photon Deposits all energy in ~1  m 3 volume in silicon; 1640e − Sometimes will deposit maximum energy in a single diode and no charge will diffuse  absolute calibration! Binary readout from pixel array Need to differentiate distribution to get signal peak in threshold units (TU) Differential approximation

Array of PreShape Pixels: Pedestals Threshold scan of individual pixels Note differing threshold scans of noise! Plot the distribution of pedestals Falling edge Calculate necessary trim adjustment Per-pixel trim file uni-directional adjustment Re-scan pixels individually with trims Re-plot the distribution of pedestals

Array of PreShape Pixels: Gains Use laser to inject fixed-intensity signal into many pixels Relative position should be equivalent for each pixel scanned Adjust/trim for known pixel pedestals Gain uniform to 12% Quad1 ~40% more gain than Quad0 Quad1 ~20% better S/N than Quad0

Array of PreShape Pixels: Beam Test Took advantage of beam-test opportunity very soon after receiving sensors before long shut-down at DESY Proof of 4-sensor system Did see particles in multiple layers Sensor pedestals were not trimmed at this time Little usable data 

Immediate Future Characterisation of v1.0 is still ongoing Automated laser tests Cosmics stack Version 1.1 due back late September One pixel variant selected (preShape quad1) Upgrade trim adjustment from 4bits to 6bits Compatible format: size, pins, pcb, daq etc. Minor bugs fixed Additional test pixels & devices Version 1.1 Full Characterisation Automated laser tests test pixels array Source tests Cosmic tests Beam test early 2009 With trims this time!

Long Term future Version 2 is part of a proposal submitted last week! Larger sensor 25x25mm Tiled to create a 125x125mm layer of pixels Minimum dead space between sensors Wire bonded through PCB holes Stacked in 16 layers to ultimately prove the Digital ECAL concept

Conclusions First Sensor Successful operation of highly complex pixels See α & β radioactive sources See laser injection of charge See beam particles (albeit with low efficiency at the time) Proved viability of the Deep P-Well for applying MAPS to particle physics Selected a preferred pixel design to take forward Some minor bugs Low level data corruption Some coupling between power domains generating false hits Revised Sensor Uniform array of improved pixels Full characterisation ready to go! Exciting future Prove “Digital ECAL” concept using CMOS sensors