DECam Daily Flatfield Calibration DECam calibration workshop, TAMU April 20 th, 2009 Jean-Philippe Rheault, Texas A&M University.

Slides:



Advertisements
Similar presentations
Richard Young Optronic Laboratories Kathleen Muray INPHORA
Advertisements

Computer Vision Radiometry. Bahadir K. Gunturk2 Radiometry Radiometry is the part of image formation concerned with the relation among the amounts of.
Optical sources Lecture 5.
Polarization measurements for CLARREO
OL 750 Diffuse Spectral Reflectance Measurement System
A Guide to Spectroradiometry
Spectral Resolution and Spectrometers
11 Components of Optical Instruments Lecture Spectroscopic methods are based on either: 1. Absorption 2. Emission 3. Scattering.
1 Components of Optical Instruments, Cont… Lecture 6.
Present status of the laser system for KAGRA Univ. of Tokyo Mio Lab. Photon Science Center SUZUKI, Ken-ichiro.
Measuring BRDFs. Why bother modeling BRDFs? Why not directly measure BRDFs? True knowledge of surface properties Accurate models for graphics.
Spectral Resolution and Spectrometers A Brief Guide to Understanding and Obtaining the Proper Resolution of the 785 Raman System.
Computer Vision - A Modern Approach Set: Radiometry Slides by D.A. Forsyth Radiometry Questions: –how “bright” will surfaces be? –what is “brightness”?
ABRF meeting 09 Light Microscopy Research Group. Why are there no standards? Imaging was largely an ultrastructure tool Digital imaging only common in.
Panasonic Electric Works Corporation of America NaPiCa Light Sensor Oct 2009.
SIW 2003 The antenna element Ravi ATNF, Narrabri 1.The role of the antenna in a Fourier synthesis radio telescope 2.The Compact array antenna.
Lecture #2 Seeing the light 1/29/13. What happens to light when it interacts with matter? Reflects Absorbed Refracts Changes speed Polarized Diffracts.
Remote sensing in meteorology
K-Space Associates, Inc. kSA BandiT: Band-edge Thermometry.
Illumination Model How to compute color to represent a scene As in taking a photo in real life: – Camera – Lighting – Object Geometry Material Illumination.
OL 750 Measurement Systems
Properties of Multilayer Optics An Investigation of Methods of Polarization Analysis for the ICS Experiment at UCLA 8/4/04 Oliver Williams.
ASIC3 WorkshopLandsdowne, VA May 16-18, 2006 J. Harder Page 1 Calibration Status of the Solar Irradiance Monitor (SIM) : The Present and the Future Jerald.
Modeling the imaging system Why? If a customer gives you specification of what they wish to see, in what environment the system should perform, you as.
BRDF Measurement.
Richard Young Richard Young Optronic Laboratories Kathleen Muray Kathleen Muray INPHORA Carolyn Jones Carolyn Jones CJ Enterprises.
Measure, measure, measure: BRDF, BTF, Light Fields Lecture #6
Fiber Optic Light Sources
1 CCTV SYSTEMS LIGHTING AND ILLUMINATION. 2 CCTV SYSTEMS A video camera requires light to work properly, without sufficient light the video camera can’t.
Integration and Alignment of Optical Subsystem Roy W. Esplin Dave McLain.
Optical Characterization of Liquid Crystal Switchable Mirror Philippe Lemarchand School of Physics You Supervisors’ Names Here Prof. Brian Norton Dr. John.
CS 445 / 645: Introductory Computer Graphics
EECS 274 Computer Vision Light and Shading. Radiometry – measuring light Relationship between light source, surface geometry, surface properties, and.
CINDI Workshop, BIRA, Brussels, Pandora Direct Sun Data during CINDI Alexander Cede Nader Abuhassan Jay Herman.
NA62 Gigatracker Working Group Meeting 2 February 2010 Massimiliano Fiorini CERN.
D EDICATED S PECTROPHOTOMETER F OR L OCALIZED T RANSMITTANCE A ND R EFLECTANCE M EASUREMENTS Laetitia ABEL-TIBERINI, Frédéric LEMARQUIS, Michel LEQUIME.
Transmittance Measurement Presented by Dr. Richard Young VP of Marketing & Science Optronic Laboratories, Inc.
14 October Observational Astronomy SPECTROSCOPY and spectrometers Kitchin, pp
AIC Colour 05 1 Reflectance changes in white reflectance standards measured in different instruments with 0/d geometry Joaquín Campos, Alicia Pons and.
Sphere Standards and Standard Spheres Dr. Richard Young Optronic Laboratories, Inc.
Optronic Laboratories Inc. OL Series 750 Automated Spectroradiometric Measurement System Optronic Laboratories Inc. OL Series 750 Automated Spectroradiometric.
Eusoballoon optics test Baptiste Mot, Gilles Roudil, Camille Catalano, Peter von Ballmoos Test configuration Calibration of the light beam Exploration.
1 SNAP Calibration Hardware Contributors: Chuck Bower Nick Mostek Stuart Mufson Mike Sholl.
September 16, 2008LSST Camera F2F1 Camera Calibration Optical Configurations and Calculations Keith Bechtol Andy Scacco Allesandro Sonnenfeld.
1 WIYN One Degree Imager. 2 Filter Changer 3 Demonstration Filters  Sloan g’ r’ and i’ delivered from Infinite Optics  Johnson U on order from Barr.
Photo-realistic Rendering and Global Illumination in Computer Graphics Spring 2012 Material Representation K. H. Ko School of Mechatronics Gwangju Institute.
1.Stable radiation source 2.Wavelength selector 3.Transparent sample holder: cells/curvettes made of suitable material (Table 7- 2) 4.Radiation detector.
OL 750 Measurement Systems OL 750 Measurement Systems Optronic Laboratories, Inc.
State of Engineering in Precision Agriculture, Boundaries and Limits for Agronomy.
The law of reflection: The law of refraction: Image formation
1Ellen L. Walker 3D Vision Why? The world is 3D Not all useful information is readily available in 2D Why so hard? “Inverse problem”: one image = many.
Observing Transfer Functions For Multimode Spectrometers.
1 Progress of the Thomson Scattering Experiment on HSX K. Zhai, F.S.B. Anderson, D.T. Anderson HSX Plasma Laboratory, UW-Madison Bill Mason PSL, UW-Madison,
Date of download: 6/2/2016 Copyright © 2016 American Medical Association. All rights reserved. From: Airway Luminal Diameter and Shape Measurement by Means.
GS-1150 HANDHELD SPECTROPHOTOMETER. ABOUT GAMMA SCIENTIFIC With over 50 years of experience in developing commercial light measurement instruments, Gamma.
Optical calibration from ten to hundreds of meters for the Neutrino Burst Experiment (a poor man’s Km 3 underwater neutrino telescope) NESTOR/NOA Spyridon.
DECam Spectrophotometric Calibration DECam calibration workshop, TAMU April 20 th, 2009 Jean-Philippe Rheault, Texas A&M University.
Digital Light Sources First introduced in 2001.
Optical Non-Invasive Approaches to Diagnosis of Skin Diseases
Relative Spectral Response and Flat Fields with Internal Calibration Lamps Luisa M. Lara IAA-CSIC Granada (SPAIN)
Radiometry (Chapter 4).
Detective Quantum Efficiency Preliminary Design Review
GAJENDRA KUMAR EC 3rd YR. ROLL NO
Optical Non-Invasive Approaches to Diagnosis of Skin Diseases
DCS-7410/7510 Day & Night Outdoor PoE Network Camera
OL 750 Measurement Systems
Remote sensing in meteorology
Optics Alan Title, HMI-LMSAL Lead,
OL 750 Spectroradiometer & Linear Spectral Transmission Measurements
Leaders in Light Perfect for Raman
Presentation transcript:

DECam Daily Flatfield Calibration DECam calibration workshop, TAMU April 20 th, 2009 Jean-Philippe Rheault, Texas A&M University

Daily Dome Flat Description: – Traditional dome flat with improved components and more controlled operation. Special attention to light source, screen properties and real-time power monitoring Requirements – Calibration in u, g, r, i, z and Y ( nm) – Homogeneous illumination of focal plane Approx 1% uniform illumination – Sufficiently bright to keep integration time short and allow daytime flats – Stable light power output (minimal drift with time or from night to night)

Schematic of the daily dome flat setup – LED(s) placed directly on top of telescope – Illumination uniformity insured by beam shaping optics – Uniform, lambertian screen – Feedback loop stabilized LED output

LEDs as a light source Advantages of LEDs Reliable (lasts for 10,000 hours +) Cheap (few $ per LED) many wavelengths available (quasi-continuous coverage from 300nm to 1500nm) small footprint: can be mounted directly on top of telescope Directional output (less stray light in the dome) very efficient (no heat dissipation) Well suited to power modulation – light output can be made constant over time with closed loop control (flatfield exposure time constant).

LEDs as a light source – Disadvantages of LEDs Non uniform Beam profile, (20nm to 100nm) bandwidth is narrower than a filter bandwidth. – We may need more than one LED per filter – Some “White” LEDs have wider profile but their output changes with wavelength, they have a big blue peak.

LED Characterization: Spatial Uniformity We built a test bench to measure the angular output of the LEDs LED on a rotating stage and we monitor the power read by a 1cm diameter detector at 50cm distance (1 degree resolution), while we change the angle. Many LED types available: Narrow, wide, with a lens, diffuse

Beam shaping To ensure uniform illumination of the screen, each LED will have beam shaping optics Might even use a diffuser in front of LED. Uniformity can be further improved by judicious placement of the LEDs on the telescope. – On a ring around top – In the center

Example of an illumination pattern that will require optics to make pattern more uniform.

LED Characterization: Spectral output Built a LED spectral output test bench – Light from LED collected in Integrating sphere – Fed through a fiber to a Spectrometer – Get spectrum from 300 to 1050 nm

Example of LED Spectra Typical LED spectra: ~40 nm FWHM Symmetrical around max Smooth, no spectral features White LED spectra: ~ 200nm wide Strong spectral features Blue LED (480nm) with fluorescent coating

LED spectral content Wide variety of wavelength and power Also available for the IR, this is a limited sample from Thorlabs and Digi-key Either use a single LED in the middle of the band Or combining 2-3 LEDs to get a more uniform profile We can adjust the relative power of LEDs in one group by electronic modulation ugrizY

Variability and long term stability More tests to be done – Spectral and spatial variations Vs temperature Vs drive current long term drift – Closed loop control can correct for most of these We have the tools to do all that.

Screen Requirements: – Screen material should have good reflectivity (spectral and spatial) – Illumination of screen is uniform enough to get good focal plane uniformity Tests: – Total hemispherical reflectance vs wavelength – BRDF (Bidirectional Reflectance Distribution Function) bench. (spatial uniformity) – ZEMAX modeling to see dependence of focal plane uniformity

Reflectivity: Wavelength dependence Labsphere Duraspect Soricscreen, good material not available anymore DaLite Matte White excellent scattering properties, reflectivity dips below 400nm (TiO2) Duraspect coating (paint type). Extremely resistant, designed for outdoor use

Reflectivity: spatial dependence (BRDF) We built a bench to measure BRDF on our screen samples BRDF is a function that relates the reflectivity value for any incident angle to an exit angle.

BRDF of a quasi Lambertian surface (DaLite Matte-White)

BRDF of a surface with a specular component in the reflectivity pattern (DaLite Da-MAT)

We can simplify the BRDF LEDs will illuminate screen from an incident angle of 0 to 30degree Only light reflected within the acceptance angle of telescope ~ 2degrees will be seen by camera Mirror: 1 at 0 degree, 0 everywhere else The reflected light would ideally remain constant for different incident light angle

Screen selection – Based on these results we are testing the labsphere coating. Excellent reflectivity across wavelength range Diffuse properties similar to Matte-White material according to manufacturer (to be verified) – Lightweight honeycomb panels got some in the lab

Zemax modeling Since the illumination pattern will not be perfect on the screen, we need to quantify how that will impact the flatfield uniformity. Use Zemax to model the illumination pattern from LEDs We can input the measured BRDF directly into the model

4 LED model 4 LEDs on perimeter Very narrow LED pattern Poor illumination uniformity on screen Uniformity of focal plane is much better (factor of 2) More modeling to determine the required uniformity of screen producing flat illumination Screen Focal plane

Monitoring and closed loop control Requirement – Allows us to compensate for fluctuations Constant exposure times Description – Photodiode facing the screen and in focal plane measure light level. – Closed loop system tells the LED driver to vary the electrical power accordingly to keep stable output. – Temperature control?

Summary LED will make good illumination sources More tests on the Duraflect screen material but looks ideal for our application Closed loop – photodiodes will ensure stable and repeatable measurements