Tunable, resonant heterodyne interferometer for neutral hydrogen measurements in tokamak plasmas * J.J. Moschella, R.C. Hazelton, M.D. Keitz, and C.C.

Slides:



Advertisements
Similar presentations
Status and activity on LIF-technique development in NFI. I.Moskalenko, N.Molodtsov, D.Shcheglov.
Advertisements

Direct Frequency Comb Spectroscopy for the Study of Molecular Dynamics in the Infrared Fingerprint Region Adam J. Fleisher, Bryce Bjork, Kevin C. Cossel,
Raman Spectroscopy A) Introduction IR Raman
CAVITY RING DOWN SPECTROSCOPY
Brian Siller, Andrew Mills & Benjamin McCall University of Illinois at Urbana-Champaign.
Ruby Laser Crystal structure of sapphire: -Al2O3 (aluminum oxide). The shaded atoms make up a unit cell of the structure. The aluminum atom inside the.
Generation of short pulses
EM Radiation Sources 1. Fundamentals of EM Radiation 2. Light Sources
Spectroscopy 2: Electronic Transitions CHAPTER 14.
Magneto-optical study of InP/InGaAs/InP quantum well B. Karmakar, A.P. Shah, M.R. Gokhale and B.M. Arora Tata Institute of Fundamental Research Mumbai,
Progress and New Results from the H-1NF Scanning Interferometer Scott Collis, George Warr, John Howard.
Cavity QED as a Deterministic Photon Source Gary Howell Feb. 9, 2007.
Microwave Spectroscopy I
Designing High Power Single Frequency Fiber Lasers Dmitriy Churin Course OPTI
49th Annual Meeting of the Division of Plasma Physics, November , 2007, Orlando, Florida Ion Temperature Measurements and Impurity Radiation in.
Electron Paramagnetic Resonance spectrometer
Time out—states and transitions Spectroscopy—transitions between energy states of a molecule excited by absorption or emission of a photon h =  E = E.
4-1 Chap. 7 (Optical Instruments), Chap. 8 (Optical Atomic Spectroscopy) General design of optical instruments Sources of radiation Selection of wavelength.
An Introduction. The first step on the road to laser was the publication of paper by Albert Einstein in 1916 –describing how atoms could interact with.
1 P1X: Optics, Waves and Lasers Lectures, Lasers and their Applications i) to understand what is meant by coherent and incoherent light sources;
Profile Measurement of HSX Plasma Using Thomson Scattering K. Zhai, F.S.B. Anderson, J. Canik, K. Likin, K. J. Willis, D.T. Anderson, HSX Plasma Laboratory,
10-1 Application of IR Raman Spectroscopy 3 IR regions Structure and Functional Group Absorption IR Reflection IR Photoacoustic IR IR Emission Micro.
A Singular Value Decomposition Method For Inverting Line Integrated Electron Density Measurements in Magnetically Confined Plasma Christopher Carey, The.
Observation of Excited Biexciton States in CuCl Quantum Dots : Control of the Quantum Dot Energy by a Photon Itoh Lab. Hiroaki SAWADA Michio IKEZAWA and.
Solution Due to the Doppler effect arising from the random motions of the gas atoms, the laser radiation from gas-lasers is broadened around a central.
High Precision Mid-Infrared Spectroscopy of 12 C 16 O 2 : Progress Report Speaker: Wei-Jo Ting Department of Physics National Tsing Hua University
Interaction of radiation with atoms and ions (I) Absorption- Stimulated emission E1E1 E2E2 W 12 =W 21 Spontaneous emission More definitionsCross section.
Photos placed in horizontal position with even amount of white space between photos and header Sandia National Laboratories is a multi-program laboratory.
12/03/2013, Praga 1 Plasma MHD Activity Observations via Magnetics Diagnostics: Magnetic island Analysis Magnetic island Analysis Frederik Ostyn (UGent)
Brian Siller, Andrew Mills, Michael Porambo & Benjamin McCall University of Illinois at Urbana-Champaign.
Pump/Probe Microwave-Optical Double Resonance (PPMODR) Study of Tungsten Carbide( WC) a and Platinum Carbide(PtC) b Funded by Fang Wang, Chengbing Qin,
N. Yugami, Utsunomiya University, Japan Generation of Short Electromagnetic Wave via Laser Plasma Interaction Experiments US-Japan Workshop on Heavy Ion.
Plasma diagnostics using spectroscopic techniques
Brian Siller, Andrew Mills, Michael Porambo & Benjamin McCall Chemistry Department, University of Illinois at Urbana-Champaign.
Ch 8: Stars & the H-R Diagram  Nick Devereux 2006 Revised 9/12/2012.
Transverse Profiling of an Intense FEL X-Ray Beam Using a Probe Electron Beam Patrick Krejcik SLAC National Accelerator Laboratory.
Thermometry using Laser Induced Thermal Grating Spectroscopy (LITGS) Joveria Baig.
PROPERTIES OF LASER BEAMS  Laser beam is generated in a specific wave length by the interaction of electromagnetic wave with the active medium.  To represent.
Electronic Transitions of Palladium Monoboride and Platinum Monoboride Y.W. Ng, H.F. Pang, Y. S. Wong, Yue Qian, and A. S-C. Cheung Department of Chemistry.
NSTX Boundary Density Fluctuation Measurement by FIReTIP System with USN/LSN Configurations K.C. Lee, C.W. Domier, M. Johnson, N.C. Luhmann, Jr. University.
Electron Density Distribution in HSX C. Deng, D.L. Brower Electrical Engineering Department University of California, Los Angeles J. Canik, S.P. Gerhardt,
Observation of ultrafast nonlinear response due to coherent coupling between light and confined excitons in a ZnO crystalline film Ashida Lab. Subaru Saeki.
Ionization Energy Measurements and Spectroscopy of HfO and HfO+
Haifeng Huang and Kevin K. Lehmann
Femtosecond Laser Spectroscopy of C 60 Nieuwegein, The Netherlands August 21, 2001 Eleanor Campbell, Göteborg University & Chalmers, Sweden R.D. Levine,
Study of NSTX Electron Density and Magnetic Field Fluctuation using the FIReTIP System K.C. Lee, C.W. Domier, M. Johnson, N.C. Luhmann, Jr. University.
1/10 Tatsuya KUME Mechanical Engineering Center, High Energy Accelerator Research Organization (KEK) ATF2-IN2P3-KEK kick-off meeting (Oct. 10, 2006) Phase.
I.Introduction II. System Design B.E. Unks, N. A. Proite, D. D. Yavuz University of Wisconsin – Madison The above figure shows a block diagram of the apparatus.
LASER PHOTODISSOCIATION SPECTRA OF THE ANILINE-ARGON CATIONIC CLUSTER IN THE NEAR INFRARED T. PINO, S. DOUIN, Ph. BRECHIGNAC Laboratoire de Photophysique.
Chapter 11. Laser Oscillation : Power and Frequency
Yan Zhou, Anthony Colombo, David Grimes, Robert Field Cooperative effects in a dense Rydberg gas.
Measurement of Electron Density Profile and Fluctuations on HSX C. Deng, D.L. Brower, W.X. Ding Electrical Engineering Department University of California,
Progress of gas-filled RF hadron monitor study K. Yonehara APC, Fermilab 2/10/16K. Yonehara1.
Date of download: 6/1/2016 Copyright © 2016 SPIE. All rights reserved. (a) Vision of the Brillouin lidar operated from a helicopter. The center ray represents.
C. Deng and D.L. Brower University of California, Los Angeles J. Canik, D.T. Anderson, F.S.B. Anderson and the HSX Group University of Wisconsin-Madison.
High Precision Mid-IR Spectroscopy of 12 C 16 O 2 : ← Band Near 4.3 µm Jow-Tsong Shy Department of Physics, National Tsing Hua University,
Many-Body Effects in a Frozen Rydberg Gas Feng zhigang
Using diode laser for atomic physics (I)
Design of Interferometer System
M. Faheem, R. Thapa, and Kristan L. Corwin Kansas State University
Impurity Transport Research at the HSX Stellarator
Really Basic Optics Instrument Sample Sample Prep Instrument Out put
Charge Exchange Analysis Diagnostic Development
Atomic Absorption Spectroscopy
Tunable Slow Light in Cesium Vapor
Raman Spectroscopy A) Introduction IR Raman
N.Kukhtarev, T.Kukhtareva, P.Land, J.H. Caulfield, and J.Wang
PRINCIPLE AND WORKING OF A SEMICONDUCTOR LASER
SRF Cavity Etching Using an RF Ar/Cl2 Plasma
Presentation transcript:

Tunable, resonant heterodyne interferometer for neutral hydrogen measurements in tokamak plasmas * J.J. Moschella, R.C. Hazelton, M.D. Keitz, and C.C. Klepper HY-Tech Research Corporation, Radford, VA Plasma Facing Components Meeting Princeton, NJ May 9-11, 2005 * This work supported by the Department of Energy through a SBIR Phase I Contract No. DE-FG02-04ER83974

Outline I. Explain the physical basis for the diagnostic II. Describe the apparatus III. Example of measurements using pulsed plasmas IV. Concluding remarks

Program overview A two wavelength interferometer has been developed to measure the n=2 state densities of H, D, or T in a plasma. This is intended for use in studying tokamak edge physics. One of the wavelengths is resonant with the 2p-3d transition (ie. H , D , T  ) and is adjusted using a tunable diode laser. By varying the laser wavelength during the discharge, information on the line shape and center can also be determined. All quantities are determined from the measured phase shift, therefore no intensity calibration is required.

Spectral line interferometry Near an optically allowed transition in a given species, the refractive index is significantly enhanced. The enhancement depends on the: - absorption oscillator strength - line shape - laser wavelength or frequency - population density of the species in the lower state Analysis from Measures, Appl. Opt. 9(3) (1970)

A non-resonant laser interferometer is required to isolate the resonant effects R  free electrons + vibrations + desired species state density N  free electrons + vibrations For this to function optimally R and N must have common paths so environmental factors are the same for both interferometers.

Interferometer design R from a low power (10 mW) tunable diode laser Å (~10 k$) - can be used for H  (6563), D , T , or CII (6578, 6583) - slew rate of 500 Hz. N from a HeNe laser at 6328 Å Both interferometers use a heterodyne detection system where an AOM is used to shift the reference beams by 40 MHz. R & N are combined and fed into a single mode optical fiber. Fibers are used to bring the beams to and from the experimental apparatus. R & N are split and sent to individual detectors.

Apparatus schematic (I) All components are located in an electrically shielded room isolated from vibrations

Apparatus schematic (I) All components are located in an electrically shielded room isolated from vibrations

Apparatus schematic (II) Laboratory configuration used during the Phase I testing Specific configuration is optional

Minimum estimated sensitivities for phase detection measurements with a heterodyne interferometer. T(eV)n min [n=2](cm -2 )n min [n=1](cm -2 )* x x x x x x10 12 *Based on calculations of Johnson and Hinnon, L.C. Johnson and E. Hinnon, J. Quant. Spectrosc. Radiat. Transfer, 13, 333 (1973).

Phase I experimental test-bed Use the gas driven, inverse pinch (IP) plasma source (inverse z-pinch geometry). IP source was mounted inside a coaxial plasma opening switch, Al electrodes. Plasma duration ~ 1  s, density ~ cm -3, T e ~ 1 eV, 1-5 cm axial length.

The behavior of the P(u,α ) function was verified The IP was used with H 2 gas in the POS configuration 12 shots were taken at different laser wavelengths

Details of the line were determined from the data  was determined from the peaks in the phase assuming  was small. wavelength was converted to (  -  o )/  P(u,  ) for  =.01 fit the data reasonably well This result implies a line that is ~ 1 Å wide (T= 2.3 eV).

The deduced line profile compares well to that previously measured by emission

Results of the IP surface interaction Motivated by observation of low impurity concentrations in H/POS shots and high concentrations in Ar/POS shots.

Concluding remarks The Phase I program has resulted in a working diagnostic. The diagnostic was used to measure the H (n=2) state density using a pulsed plasma device. The line width was also determined from the analysis and agrees with a previous emission measurement under the same conditions. The Phase II proposal has been submitted that includes a cooperative arrangement with General Atomics and plans for a multi-view version of the diagnostic.

Comparison with alternative techniques (H  emission and L  LIF) Resonant interferometry (RI) vs. emission spectroscopy (ES) –RI measures n=2 directly with no calibration vs. n=3 for ES. –RI has superior transverse spatial resolution (1 mm) compared to ES. –RI has superior spectral resolution (~ 3x10 -5 Å) compared to ES (5x10 -3 Å). RI vs Å –LIF measures the n=1 (ground state) density. –LIF also provide local information. –The temporal resolution of the LIF system is limited due to the laser pulse rate. –The LIF diagnostic is far more difficult and expensive to field primarily because of the laser system involved.