Ralph Assmann What Do We Want To Measure (in 2009) R. Assmann S. Redaelli, V. Previtali CERN/BE discussed with W. Scandale CERN/EN26/3/2009CC09  See also.

Slides:



Advertisements
Similar presentations
DS Quench TEST 2  MOTIVATION and METHOD: 1. Achieve 500kW on beam 1 – TCP7 collimators.(so far 500kW with beam 2 and 235kW over 1s with beam 1 were reached.
Advertisements

W. Scandale for the UA9 Collaboration CERN – IHEP - Imperial College – INFN – JINR – LAL - PNPI – SLAC LAL January 24, 2012.
W. Scandale for the UA9 Collaboration CERN – IHEP - Imperial College – INFN – JINR – LAL - PNPI – SLAC SPSC, October 25, 2011.
Critical beam losses during Commissioning & Initial Operation Guillaume Robert-Demolaize (CERN and Univ. Joseph Fourier, Grenoble) with R. Assmann, S.
Helmholtz International Center for Oliver Boine-Frankenheim GSI mbH and TU Darmstadt/TEMF FAIR accelerator theory (FAIR-AT) division Helmholtz International.
Round table magnet discussion and conclusions CARE-HHH IR’07 animated by W. Scandale and F. Zimmermann.
SLAC rotating collimator for HiRadMat beam tests 14 March 2014 S. Redaelli, A. Bertarelli, CERN T. Markiewicz, SLAC US LHC Accelerator Research Program.
GRD - Collimation Simulation with SIXTRACK - MIB WG - October 2005 LHC COLLIMATION SYSTEM STUDIES USING SIXTRACK Ralph Assmann, Stefano Redaelli, Guillaume.
Loss maps of RHIC Guillaume Robert-Demolaize, BNL CERN-GSI Meeting on Collective Effects, 2-3 October 2007 Beam losses, halo generation, and Collimation.
T-980 Crystal Collimation Recent Results T-980 Collaboration: FNAL, SLAC, BNL, CERN, PNPI, IHEP, INFN D. Still CM14 April 27, 2010.
Off-momentum tail scraping for passive abort gap cleaning (MD 444) D. Mirarchi, R. Bruce, S. Redaelli On behalf of the LHC Collimation Team LHC Study Working.
DANIELE MIRARCHI CERN FOR UA9 COLLABORATION Data reduction and analysis of SPS data.
W. Scandale 1 Status of UA9 Walter Scandale CERN CC09 5 th workshop on crystal channeling March 2009.
Crystal channeling 2009 A. Afonin, IHEP, Protvino New results of use and research of crystals at U-70. A.Afonin, IHEP, Protvino 4- th Crystal channeling.
October 4-5, Electron Lens Beam Physics Overview Yun Luo for RHIC e-lens team October 4-5, 2010 Electron Lens.
Concept of a Collimation System with Enhanced Operational Stability and Performance.
CLIC Implementation Studies Ph. Lebrun & J. Osborne CERN CLIC Collaboration Meeting addressing the Work Packages CERN, 3-4 November 2011.
LHC Studies Working Group – 03 July 2012 Beam Scraping and Diffusion + Asynchronous Dump MD G. Valentino, R. W. Assmann, F. Burkart, L. Lari, S. Redaelli,
Luminosity expectations for the first years of CLIC operation CTC MJ.
Comparisons between simulations and data for crystal-assisted collimation Daniele Mirarchi, Stefano Redaelli, Walter Scandale, Roberto Rossi.
Preparation of Review R. Assmann et al CWG, CWG R. Assmann.
R. Assmann - LHCCWG Two Beam Operation R.W. Aßmann LHCCWG Acknowledgements to W. Herr, V. Previtali, A. Butterworth, P. Baudrenghien, J. Uythoven,
Machine development - results and plans – critical results, what’s to be done? R. Assmann 15/07/2011 R. Assmann for the LHC MD coordination team (R. Assmann,
1 CC & MP - CC10 - CERN Crab LHC J. Wenninger CERN Beams Department for the LHC Machine Protection Panel.
Status of UA9 1 W. Scandale on behalf of the UA9 Collaboration W. Scandale – SPSC 20/10/2015 Introduction Measurements and tests in the SPS North Area.
SPS UA9 data taking run with LHC-type Goniometer 31/07/2015 – Collimation Upgrade Specification Meeting #60 Roberto Rossi Daniele Mirarchi, Stefano Redaelli,
Status from the collimator impedance MD in the LHC Collimation team:R. Assmann, R. Bruce, A. Rossi. Operation team:G.H. Hemelsoet, W. Venturini, V. Kain,
Crystal collimation for LHC Valery Biryukov IHEP Protvino Vincenzo Guidi Ferrara University and INFN Walter Scandale CERN CERN, Geneva, 24 April 2003.
CERN 9 March 2006Biryukov: crystal collimation1 Simulations and interpretation of crystal collimation experiments at RHIC and Tevatron CERN, 9 March 2006.
LHC Crystal MD 22/09/2015 – LSWG #7 R. Rossi for the LHC Collimation team and the UA9 Collaboration.
Study Group for slow extraction assisted by bent crystals in the SPS B.Goddard, W.Scandale 23/7/15.
ATLAS-ALFA as a beam instrument Sune Jakobsen (BE-BI-PM and PH-ADO) on behave of the ATLAS-ALFA community LS1 LBOC meeting
LHC-CC Validity Requirements & Tests LHC Crab Cavity Mini Workshop at CERN; 21. August Remarks on using the LHC as a test bed for R&D equipment.
Chamonix 2006, B.Dehning 1 Commissioning of Beam Loss Monitors B. Dehning CERN AB/BDI.
Organization of the UA9 Simulations WG R. Noble, W. Scandale, Andrei Seryi, M. Silari (on behalf of the WG) UA9 Collaboration Meeting 14 May UA9.
Education Thesis: Layout and design of a high accuracy magnetic field measurement system for superconducting undulators. Thesis: Phase error reduction.
Status and Results of the UA9 Crystal Collimation Experiment at CERN-SPS Walter Scandale (CERN, LAL, INFN) for the UA9 collaboration Mini-workshop UA9,
Collimator settings for 2012 R. Bruce, R. Assmann for the collimation team
R. Assmann, June 2009 Operational Experience with the LHC Collimation System R. Assmann, CERN 8/6/2009 for the Collimation Project Team Visit TU Munich.
NM4SixTrack Implementation of new composite materials for HL-LHC collimator upgrades in SixTrack “Tracking for SixTrack” workshop – CERN, R.
The way to fast and "loss-free" SPS kickers E. Gaxiola With contributions from AB-BT-KSL section and F. Caspers, T. Kroyer, M. Timmins, J. Uythoven.
LER Workshop, Oct 11, 2006Intensity Increase in the LER – T. Sen1 LHC Accelerator Research Program bnl-fnal-lbnl-slac  Motivation  Slip stacking in the.
Progress with Beam Report to LMC, Machine Coordination W10: Mike Lamont – Ralph Assmann Thanks to other machine coordinators, EIC’s, operators,
Collimation design considerations at CERN (with some applications to LHC) R. Bruce on behalf of the CERN LHC collimation project R. Bruce,
CHANNELING 2014 COMPTE-RENDU R.CHEHAB R.Chehab/Channeling20141.
Collimation Aspects for Crab Cavities? R. Assmann, CERN Thanks to Daniel Wollmann for presenting this talk on my behalf (criticism and complaints please.
CRYSTAL COLLIMATION EXPERIMENT AT THE TEVATRON CSN1 LNF 17 September 2007 Walter Scandale CERN.
VP 26.MAR.09 V. Previtali CERN & EPFL R. Assmann, S. Redaelli, CERN I. Yazynin, IHEP CC March 2009 CERN Simulations for Crystal (UA9)
CRYSTALS AS LONG-TERM IMPROVEMENT FOR LHC COLLIMATION
Outline of the presentation
ICE SECTION The coolest place to be! Elias Métral
T980 STATUS AND CHANGES FOR
BEAM LOSS MONITORING SYSTEM
Bending crystals for magnetic and electric dipole moment measurements
Cryo Problem MD Planning Tue (1.11.) C B Day Time MD MP Tue 01:00
Potential failure scenarios that can lead to very fast orbit changes and machine protection requirements for HL-LHC operation Daniel Wollmann with input.
Saturday 21st April 00:33 Interlock during ramp on BLM HV
Joint Meeting SPS Upgrade Study Group and SPS Task Force
History of Crystal Extraction at the SPS (RD22)
Ralph Aßmann (DESY) 2nd collaboration week November 24th, 2017, Lisbon
Acknowledgments: LIU-PT members and deputies, H. Bartosik
BEAM LOSS MONITORING SYSTEM
Beam collimation for SPPC
Intensity Evolution Estimate for LHC
Proton Intensity Evolution Estimates for LHC
Status from the collimator impedance MD in the LHC
LHC Collimation Requirements
The Proposed Conversion of CESR to an ILC Damping Ring Test Facility
Why do BLMs need to know the Quench Levels?
Collimation margins and *
Presentation transcript:

Ralph Assmann What Do We Want To Measure (in 2009) R. Assmann S. Redaelli, V. Previtali CERN/BE discussed with W. Scandale CERN/EN26/3/2009CC09  See also the presentation of Walter on UA9, including his remarks on goals and possible achievements.

Motivation: Improve LHC Collimation R. Assmann, CERN Collimation upgrades part of our 2003 collimation plan and effort put into place (White Paper, FP7) to find solution. Outside of collimation phase II project: Crystal R&D tests in Tevatron and SPS. But we collaborate… Once proven, will integrate into LHC upgrade plan. Crystal enhanced collimation likely needed for major LHC upgrade (phase II IR upgrade)… Collimation upgrades part of our 2003 collimation plan and effort put into place (White Paper, FP7) to find solution. Outside of collimation phase II project: Crystal R&D tests in Tevatron and SPS. But we collaborate… Once proven, will integrate into LHC upgrade plan. Crystal enhanced collimation likely needed for major LHC upgrade (phase II IR upgrade)… For example, see SPC report:

Our Goals Ralph Assmann 3 Experimentally assess the cleaning behavior of a bent crystal, acting as primary collimator  Understand crystal as primary collimator. Do this with parameters relevant to the LHC such that we can extrapolate SPS crystal results to the LHC regime. This leads us to variations in a number of parameters. Mostly interested in losses around the ring, in particular losses in the SPS magnets. Therefore we put the focus on the loss measurements with Beam Loss Monitors (BLM’s). Also interested in Roman Pots. Approach very successful for LHC collimator tests with loss maps. Want to prove that we can reproduce in simulation the measured losses in the accelerator with a bent crystal as primary collimator. Not so important to minimize losses, as long as we can get reliable measurements, proving that we understand the crystal physics and cleaning process.

Predictions for the SPS Ralph Assmann 4 VP 26.MAR.00 Local inefficiency Losses on crystal, TAL and RP’s Losses on ring aperture  Valentina

VP 26.MAR.00 Sixtrack results (Preliminary) The factor 20 improvement is confirmed LHC goal can only be reached with multi stage conventional cleaning downstream?! Up to now: linear machine, no energy spread Much higher statistic (5 million particles turns) Colltrack results are reproduced Lhc design goal Volume reflection case Channeling case  Valentina

Measurements In principle, we want to measure the loss maps for different parameters and compare them to simulations (see examples shown before). Simulation tools are ready to simulate all effects, including off-momentum behavior of particles, … In the next slides show lists of measurements that we want to do. This does not mean that all can be done in Needs more discussion and scheduling work… Also: We collaborate also with Tevatron experiment. Similar measurements can be done there as well to get more complete coverage (different energies, different diffusion properties, different crystals, …). Conditions too different to split up measurement program  want to do full program in the SPS, even if parts are done also in Tevatron. Ralph Assmann 6

(A) Static Loss Maps 1.Assume basic crystal adjustment tests have been completed and we have understood how the crystal can be aligned reliably. 2.Then measure for full crystal scan (many crystal angles) all BLM’s, BCT (stored intensity) versus: a)d  /dtEmittance growth rate: Allows to assess influence of impact parameter and surface properties. b)IIntensity: Allows to assess influence of intensity (none expected), e.g. through temperature, impedance (measure tune shift/orbit change versus intensity), … Allows to determine BLM response. c)EEnergy: Allows to assess understanding of energy dependence. d)TAL position: Important input to simulations. Retract to position furthest out, still allowing to catch extracted halo. 3.Measure same data for short W target and for LHC collimator (required to recalibrate model for 120 GeV). 4.Calculate local cleaning efficiency around ring (as used for LHC). Ralph Assmann 7

Local Cleaning Inefficiency Used for LHC assessment of collimation performance (required not to quench any given element). Defined as: Should not depend on intensity. Should depend on impact parameter. Should depend on TAL position. Requires knowledge/calibration of BLM response. Most important: Should depend on primary intercepting device used. Proposed program will allow to directly demonstrate improvement of local cleaning inefficiency with crystal over LHC collimator. Ralph Assmann 8

(B) Transient Loss Maps 1.Assume basic crystal adjustment tests have been completed and we have understood how the crystal can be aligned reliably. 2.Use fast response (40  s  20 ms) of BLM’s. 3.Then measure: a)BLM signal stability for not moving crystal: Assess possible vibrations. Determine frequency spectrum of losses. Expect machine tunes. b)BLM signal stability during crystal movement: Assess possible vibrations. 4.Calculate local cleaning efficiency around ring on a fast time scale. Ralph Assmann 9

(C) Operational Efficiency 1.Will be bad in the beginning as we learn how to use the crystal. 2.However, at some point expect to be more or less operational in using a crystal. 3.Based on SPS crystal adjustment times we can then estimate expected operational efficiency for the LHC (time and frequency for adjustments, …). 4.Done the same way for LHC prototype collimator. 5.Measurements: a)Reproducibility from fill to fill. b)Stability versus time. Ralph Assmann 10

Readiness and Time Required Readiness: –We are ready to take the data as described before. Stefano followed up on additional BLM’s. –ABP/OP data analysis in place from past collimation tests. –Simulation tools ready for the SPS and proven in past studies. Extended for crystal routine (  Valentina et al). Preliminary predictions exist. –If required we might put some additional resources from the ABP collimation team (new fellow for collimation upgrades), also to help Valentina during the time when she completes her thesis. Time required: –No detailed estimates. –Will see with experience. –Described measurements might require more than one year of tests. –As said before: Scheduling and prioritization beyond scope of this talk. Ralph Assmann 11

From SPS/Tevatron Measurements towards LHC… (My Guess for Discussion) Ralph Assmann 12 SPS/Tevatron: –Characterization of crystal as primary collimator with stored beam and diffusive beam halo. –Verification of predictive tools and models. LHC predictions: –Based on experimental data predict LHC collimation performance with crystal enhancement (at the moment simulations look promising). –Based on operational experience predict operational efficiency with 8 crystals for the LHC. Based on predictions, decide. If crystal upgrade confirmed: –Start prototyping of LHC crystal. –Modify cleaning insertions to implement power dump etc. –Test, produce all, install and commission. Timeline: Phase II upgrade of the LHC (2016?) or before?