Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough Physics Department, University of Surrey, Guildford, GU2 7XH, UK.

Slides:



Advertisements
Similar presentations
Accelerator Physics, JU, First Semester, (Saed Dababneh).
Advertisements

Stefan Roesler SC-RP/CERN on behalf of the CERN-SLAC RP Collaboration
P HI T S Exercise ( II ) : How to stop , ,  -rays and neutrons? Multi-Purpose Particle and Heavy Ion Transport code System title1 Feb revised.
Gamma-Ray Spectra _ + The photomultiplier records the (UV) light emitted during electronic recombination in the scintillator. Therefore, the spectrum collected.
Ion beam Analysis Joele Mira from UWC and iThemba LABS Tinyiko Maluleke from US Supervisor: Dr. Alexander Kobzev Dr. Alexander Kobzev.
Ion Beam Analysis techniques:
Chapter 8 Planar Scintigaraphy
Rutherford Backscattering Spectrometry
Chapter 4 Atomic Structure IRON ATOMS.
Chapter 4 Atomic Structure
First of all, do you know any methods to check chemical composition? Or how you know what is what? First of all, do you know any methods to check chemical.
Experimental Determination of Neutron Cross Sections of Yttrium by Activation Method by Barbara Geier Supervisors: Assoc. Prof Dr. Wolfgang Sprengel RNDr.
ERDA, for measurement of hydrogen in PV applications
Study of sputtering on thin films due to ionic implantations F. C. Ceoni, M. A. Rizzutto, M. H. Tabacniks, N. Added, M. A. P. Carmignotto, C.C.P. Nunes,
Types of Radiation Interactions All or Nothing Many Small There is a finite probability per unit length that the radiation is absorbed. If not, there is.
Liquid Xenon Gamma Screening Luiz de Viveiros Brown University.
Uni S School of Electronics and Physical Sciences Department of Physics University of Surrey Guildford Surrey GU2 7XH, UK Optimisation of X-ray micro-tomography.
The Origins of X-Rays. The X-Ray Spectrum The X-Ray Spectrum (Changes in Voltage) The characteristic lines are a result of electrons ejecting orbital.
Luminosity Monitors MICE Video Conference 7 May 2009 Paul Soler.
Rutherford Backscattering Spectrometry
Particle Interactions
1 Seventh Lecture Error Analysis Instrumentation and Product Testing.
Forward Detectors and Measurement of Proton-Antiproton Collision Rates by Zachary Einzig, Mentor Michele Gallinaro INTRODUCTION THE DETECTORS EXPERIMENTAL.
Planar scintigraphy produces two-dimensional images of three dimensional objects. It is handicapped by the superposition of active and nonactive layers.
Gamma Spectroscopy HPT TVAN Technical Training
Cross section measurements for analysis of D and T in thicker films Liqun Shi Institute of Modern Physics, Fudan University, Shanghai, , People’s.
Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough Physics Department, University of Surrey, Guildford, GU2 7XH, UK.
The Performance of Glass-GEM Takeshi Fujiwara, Yuki Mitsuya, Hiroyuki Takahashi, Mitsuru Uesaka The University of Tokyo, JAPAN MPGD 2013 July 2 nd 2013.
Stopping Power The linear stopping power S for charged particles in a given absorber is simply defined as the differential energy loss for that particle.
RF background, analysis of MTA data & implications for MICE Rikard Sandström, Geneva University MICE Collaboration Meeting – Analysis session, October.
The 1 st Research Coordination Meeting Reference Database for PIGE Van de Graaff Lab in Tehran activities.
3. PROTON INDUCED X-RAY EMISSION Procedure of Spectrum Analysis
Atmospheric Neutrino Oscillations in Soudan 2
X-Ray Medical Imaging Physics – IB Objectives
The PEPPo e - & e + polarization measurements E. Fanchini On behalf of the PEPPo collaboration POSIPOL 2012 Zeuthen 4-6 September E. Fanchini -Posipol.
Abstract A time resolved radial profile neutron diagnostic is being designed for the National Spherical Torus Experiment (NSTX). The design goal is to.
EDS Energy Dispersive Spectroscopy
Ruđer Bošković Institute, Zagreb, Croatia CRP: Development of a Reference Database for Ion Beam Analysis Measurements of differential cross sections for.
SuperNEMO Simulations Darren Price University of Manchester July, 2005.
FRANK LABORATORY OF NEUTRON PHYSICS ION BEAM ANALYSIS STANCIU-OPREAN LIGIA SUPERVISOR DR. KOBZEV ALEXANDER.
Water infusion and drug effusion in drug release polymers and drug diffusion in mucosae and muscle A S Clough, F E Gauntlett, M S Rihawy University of.
Environmental and Exploration Geophysics I tom.h.wilson Department of Geology and Geography West Virginia University Morgantown, WV.
Paul Sellin, Radiation Imaging Group Time-Resolved Ion Beam Induced Charge Imaging at the Surrey Microbeam P.J. Sellin 1, A. Simon 2, A. Lohstroh 1, D.
Nuclear and Radiation Physics, BAU, First Semester, (Saed Dababneh). 1 Nuclear Reactions Sample.
DDEP 2012 | C. Bisch – Study of beta shape spectra 1 Study of the shape of  spectra Development of a Si spectrometer for measurement of  spectra 
Energy-Dispersive X-ray Microanalysis in the TEM Anthony J. Garratt-Reed Neil Rowlands.
DE/dX measurement by OPERA film Tsutomu Fukuda (Nagoya Univ) Emulsion work shop (11/12,2005)
Neutron Beam Intensity for the Spallation Neutron Source Beamline 13: The NPDGamma Experiment Analysis and Results Jeremy Stewart University of Tennessee.
Walid DRIDI, CEA/Saclay n_TOF Collaboration Meeting, Paris December 4-5, 2006 DAPNIA Neutron capture cross section of 234 U Walid DRIDI CEA/Saclay for.
2. RUTHERFORD BACKSCATTERING SPECTROMETRY Basic Principles.
Spectra of the Thunderstorm Correlated Electron and Gamma-Ray Measured at Aragats Bagrat Mailyan and Ashot Chilingarian.
Cross-sections of Neutron Threshold Reactions Studied by Activation Method Nuclear Physics Institute, Academy of Sciences of Czech Republic Department.
Tests of AWAKE spectrometer screen and camera at PHIN Introduction Layout Procedure Setup, results (runs 1 – 5) Conclusions L. Deacon, S. Mazzoni, B. Biskup.
SEM Scanning Electron Microscope
Basics of Ion Beam Analysis
Neutron Capture Cross Sections from 1 MeV to 2 MeV by Activation Measurements Korea Institutes of Geoscience and Mineral Resource G.D.Kim, T.K.Yang, Y.S.Kim,
High Resolution Depth Profiling of Ti Oxidation
Measurement of the Charge Ratio of Cosmic Muons using CMS Data M. Aldaya, P. García-Abia (CIEMAT-Madrid) On behalf of the CMS Collaboration Sector 10 Sector.
Rutherford Backscattering Spectrometry (RBS)
Radiation study of the TPC electronics Georgios Tsiledakis, GSI.
Progress Report on GEANT Study of Containerized Detectors R. Ray 7/11/03 What’s New Since Last Time?  More detailed container description in GEANT o Slightly.
Electron Spectrometer: Status July 14 Simon Jolly, Lawrence Deacon 1 st July 2014.
Simultaneous photo-production measurement of the  and  mesons on the nucleons at the range 680 – 1500 MeV N.Rudnev, V.Nedorezov, A.Turinge for the GRAAL.
Alex Howard PH-SFT LCG-PV 10 th May 2006 Neutron Benchmark for Geant4 using TARC – initial status 1)TARC – experimental set-up and aims 2)Geant4 Simulation.
Extrapolation Techniques  Four different techniques have been used to extrapolate near detector data to the far detector to predict the neutrino energy.
Equalization of Medipix2 imaging detector energy thresholds using measurement of polychromatic X-ray beam attenuation Josef Uher a,b, Jan Jakubek c a CSIRO.
Open and Hidden Beauty Production in 920 GeV p-N interactions Presented by Mauro Villa for the Hera-B collaboration 2002/3 data taking:
N.Kimmel, the MPI Halbleiterlabor team and PNSensor References: H. Tsunemi et al., NIM A 421 (1999), H. Tsunemi et al., NIM A 436 (1999), Characterization.
ICARUS T600: low energy electrons
Cross Section Much of what we have learned about the internal structure of matter comes from scattering experiments (i.e. a microscope) Beam = electron,
Presentation transcript:

Ion Beam Analysis of Gold Flecks in a Foam Lattice F E Gauntlett, A S Clough Physics Department, University of Surrey, Guildford, GU2 7XH, UK

Ion Beam Characterisation of Gold-Loaded Foam Sample At Surrey we have been asked to measure: Techniques: Scanning Micro-PIXE Scanning Micro-RBS Low density foam cylinder (1mm diameter  1mm) loaded with tiny gold spheres (~ 5  m diameter). 1mm 1mm the total MASS of the gold flecks in the foam, the average SIZE of the flecks, the uniformity of DISTRIBUTION of the flecks. Gold loaded foam cylinder is encased in a Kapton (polyimide) sleeve.

Surrey Ion Beam Centre Facility: 2 MV Tandetron Beamline: Scanning in vacuo proton microbeam

Detectors Hence we use Amptek CdTe detectors which are ~100% efficient between keV. Thus we need to detect both: Gold K X-rays have energies of 66–78keV, so they are only attenuated by ~1%. However, their yield is very low. At Ep ~4MeV gold L X-rays (~10keV) are produced in abundance but they are attenuated by ~35% in a 5  m diameter gold fleck. We also detect Backscattered protons with 100mm 2 ORTEC ULTRA detectors with a 300  m depletion layer. K X-rays to determine the overall quantity of gold present L X-rays to determine from the attenuation the average size of the flecks. and

Detectors in Sample Chamber We use two detectors in both cases to obviate any instrumental asymmetries.

A Sample in Carbon Blocks and Beam Setting-Up Plate (View of Vertical Sample Holder)  m thick 2  m thick Gold Foil (Comparison) Foam Sample Scintillator Carbon Blocks Copper Grid

View of sample in the chamber through microscope at 135  to beam direction: Sample In Chamber Copper Sleeve

Carbon Oxygen Gold Energy, keV Gold L X-rays Copper K X-rays Energy, keV Counts Spectra! The PIXE spectrum, contains gold L X- rays, also a lot of copper. The Backscatter spectrum, contains carbon, oxygen and gold. The microbeam is raster scanned over the scan area, recording the position associated with each event. We can draw 2D maps corresponding with specific features (i.e. counts within a chosen energy window) on the spectra…

Carbon Backscatters, TOP Carbon Backscatters, BOTTOM Gold L X-rays, LEFT Gold L X-rays, RIGHT MAPS…. Max. Counts Min. Counts

RBS Detector Spectrum from Foam Containing Gold Flecks Oxygen Edge Carbon Edge Gold Continuum(!) Energy, keV Counts

Gold Continuum Energy, keV Counts The gold continuum is sloping, without the sharp edge typical of backscatter spectra from uniform layers:

(Assuming gold flecks are 5  m in diameter and have a total mass of ~15% of the foam mass – an upper estimate – the number of gold flecks in a cylinder is ~700 and the areal ratio (sum of cross sectional areas of gold spheres/area of foam cylinder) ~7x10 -2 i.e. 93% of the time protons in the beam incident on the foam go through the foam completely missing any gold flecks.) How Do We Explain the Shape of the Gold Continuum? 165  to detector protons It is likely that at most only 1 gold fleck is in the path of a proton.

At the highest backscatter detected energy (4.046 MeV) only the front surface nuclei of any gold fleck at the front of the foam (left on this figure) will contribute. Gold Continuum Highest Energy

At lower and lower backscatter detected energies, more and more combinations of protons backscattered from within flecks at various depths will contribute. In Gold Continuum

Au Low E Au Medium E Au High E Energy, keV Counts Example

Limiting Depth The Limiting Depth is when the backscatter energy from the front of a Au fleck at that depth is equal to the backscatter energy from Oxygen at the front of the foam (3.221MeV). Limiting Depth For 4MeV protons D L ~0.7mm. Thus to detect all the gold flecks in the full length of the foam cylinder - 1mm - with 4MeV protons we must use X-rays. Carbon Oxygen Gold Energy, keV Counts

Can we get an estimate of the gold mass? Re-run spectra offline, screening out the wire Normalisation Calculations Validation of Technique

Carbon (Backscatters) Gold (Backscatters) Top Bottom Gold and Carbon Maps from Backscatter Spectra

Gold K X-rays Gold L X-rays Left Right Gold Maps from PIXE Spectra

Energy, keV Counts New Spectra Counts Energy, keV Au L X-rays Energy, keV Energy, keV 0 90 Counts 10 Au K X-rays

Can We Get an Estimate of the Gold Mass? Re-run spectra offline, screening out the wire Normalisation Calculations Validation of Technique

Normalisation with Protons Backscattered from Carbon N C /A C Gold Foil Sample

Can we get an estimate of the gold mass? Re-run spectra offline, screening out the wire Normalisation Calculations Validation of Technique

We can use this to relate the gold K X-ray scatters from the gold flecks to those from the foil: We find M Au = 3.2  0.4  g where M Au is the mass of gold in the sample, M AuF is the mass of gold foil included in the scan and the differential cross-sections are evaluated at the mean proton energies E S, E F in the sample and foil respectively. K X-rays We then get an excellent measure of the beam charge ratio between the foam sample run and the foil run:

From this equation, using the gold mass M Au from the K X-ray measurements, we can find a characteristic attenuation length l, for the L X-rays in the gold. And for the L X-rays: We find D = 5.5  0.6  m L X-rays This can be related to the gold diameter D, using an expression derived by Dirac, for the mean chord length in any one direction in a sphere D = 3 l:

Can We Get an Estimate of the Gold Mass? Re-run spectra offline, screening out the wire Normalisation Calculations Validation of Technique

Experimental Validation Using a Complementary Technique An alternative technique to measure the mass of gold flecks in foam is XRF (rhodium target x-ray tube). However this can only produce L X-rays from gold, eliminating the technique as a candidate for measuring 5  m diameter flecks. So, to check our technique, we did measurements on a foam sample containing a similar mass of gold but having fleck diameters of ~0.5  m. In these sub-micron flecks L X-ray attenuation is of order 1%! From XRF measurements the gold mass is: M Au = 4.1  0.8  g From our K X-ray measurements we find: M Au = 3.8  0.7  g From our L X-ray measurements we find: M Au = 4.4  0.5  g All three measurements are compatible.

Another interesting feature of the measurement on the 0.5  m flecks is the Backscatter spectrum – which, at the high backscatter end, looks like one you would expect from a low density gold film. Backscatter from Sub-Micron Gold Flecks Energy, keV Counts

Estimate of mass from RBS Measurements Because of energy loss in the polyimide sleeve the gold backscatter spectrum above the Oxygen edge is representative of only a fraction, an elliptic cylinder, of the foam volume. From this though we can calculate the gold density. Assuming a uniform distribution of the gold we can then infer the mass by multiplying by the full foam cylinder volume. We find D = 5.0  0.5  g BUT: This probably over-estimates the mass due to slight deformations of the cylindrical shape.

Conclusions We have successfully: This work is continuing using an updated version of one of the CdTe detectors. This will eliminate much of the background electronic noise on the spectra of the older detector and improve the statistical accuracy. measured the mass of the gold flecks loaded within the foam, devised a novel technique for characterising gold flecks in foam, observed their spatial distribution in 2D maps, validated the technique. measured the average fleck size,

Any Questions? Thank you for listening!