DEVELOPING FIRE TESTS FOR FCV AND HYDROGEN VEHICLES Glenn Scheffler Consultant for the US Department of Energy August 2010 DEVELOPING FIRE TESTS FOR FCV.

Slides:



Advertisements
Similar presentations
GRPE ISO GROUP MEETING, MUNICH, JANUARY 22th, 2003 GAS CYLINDERS USE OF PRESSURE RELIEF DEVICES Hervé BARTHELEMY AIR LIQUIDE PARIS.
Advertisements

Brian Somerday Sandia National Laboratories Livermore, CA, USA
Student Book © 2004 Propane Education & Research CouncilPage Placing Appliances into Initial Operation Knowing the proper techniques and.
Office of Highway Safety Hazardous Materials. Oxygen Cylinders 7 cylinders in luggage bay had minimal fire damage 11 cylinders in passenger compartment.
Draft Deliberative Document1 of 15 Hydrogen Fuel Cell Vehicle Safety Research to Support Rulemaking/GTR Objectives September 2008 SGS
European Commission HFCV GTR – 3 rd SGS meeting Washington D.C., May 2008 Enterprise and Industry Directorate General Update on EU Regulation on.
Research Activities of HFCV in Korea Speaker : Economy : The Republic of Korea.
31/03/11FV 1 CEDAR from flammable gas safety point of view.
2.3.9 Student Book © 2004 Propane Education & Research CouncilPage Identifying Procedures for Purging Containers & Injecting Methanol Prior to.
Budget Shortfall Options Ian Wyatt - Atkins JIP on Bursting Disks for Shell & Tube Exchangers – 2 nd Stakeholders Meeting.
Liquefied Natural Gas Fuel tank
Proposal of Fire Resistance Test
Enclosure Fire Dynamics
Helfried Rybin 1 AUTOMOBILENTWICKLUNG / ENGINEERING Safety Demands for Automotive Hydrogen Storage Systems Helfried Rybin.
Determination of Clearance Distances for Venting of Hydrogen Storage Andrei Tchouvelev, Pierre Benard, Vlad Agranat and Zhong Cheng.
MVFRI 1 Fire Safety of Hydrogen-Fueled Vehicles: System-Level Bonfire Test by R. Rhoads Stephenson Motor Vehicle Fire Research Institute
Partner for progress Kiwa Nederland B.V. Automotive department Paul Dijkhof Informal document GRSG (103rd GRSG, 2-5 October 2012 Agenda item 7)
CNG STATION & GARAGE MODIFICATION CODES & STANDARDS Graham Barker Business Development Manager.
Learning Objective 1 Explain the ways water supply system components are used by firefighters.
Hydrogen Fueled Vehicle Global Technical Regulation (GTR) Subgroup Safety (SGS) Nha Nguyen 49 th GRSP Session May Informal document GRSP (49th.
The MICE vacuum system Presented by Mark Tucker at CM-39, 26 June 2014.
Research Activities of HFCV Rule-making in Korea Sept. 24 ~ 26, th HFCV-SGS Meeting Ministry of Land, Transport and Maritime Affairs, Korea Transportation.
1 Vehicle & Machinery Rescue. 2 On Scene Approach Survey scene –Six-sided approach –Inside / Outside Circles Scene conditions –Fire Fuels –Crowd control.
NFPA 31 Standard for the installation of Oil- Burning Equipment
Korean Research Results “Fire resistance test” June 2, 2015 Korea Transportation Safty Authority (TS) Korea Automobile Testing & Research Institute (KATRI)
Pro-Science 4 th International Conference of Hydrogen Safety, September 12-14, 2011, SAN FRANCISCO, USA EXPERIMENTAL STUDY OF IGNITED UNSTEADY HYDROGEN.
NREL is a national laboratory of the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy operated by the Alliance for Sustainable.
GRPE GRPE CGH 2 Experts (A sub-group of the GRPE Informal Group “Hydrogen/Fuel Cell”) JASIC Presentation At The GRPE CGH 2 Experts Meeting.
Research Activities of HFCV in Korea May 26 ~ 29, th HFCV-SGS Meeting Ministry of Land, Transport and Maritime Affairs, Korea Transportation Safety.
SAE J2579 Technical Information Report Fuel Systems in Fuel Cell & Other Hydrogen Vehicles Presented by Phil Horton To Hydrogen Fuel Cell Vehicle Subgroup.
AC Transit Hydrogen Energy Station / Oakland Fire Department Project AC Transit Hydrogen Energy Station / Oakland Fire Department Project You want to do.
DRAWING ON EXPERIENCE … BUILDING ON STRENGTH Six Storey Wood-Framed Buildings Unique Structural Opportunities & Challenges Kurt Ruhland, P.Eng. Director,
Status of SAE FCV Safety Working Group Activities Developing Systems-level Performance- based Standards for Hydrogen and Fuel Cell Vehicles (FCVs) Presented.
Hydrogen system R&D. R&D programme – general points Hydrogen absorber system incorporates 2 novel aspects Hydrogen storage using a hydride bed Hydrogen.
The Spread of Fire from Adjoining Vehicles to a Hydrogen Fuel Cell Vehicle Japan Automobile Research Institute Yohsuke Tamura, Masaru Takabayashi, Masayuki.
Wu. Y., International Conference on Hydrogen Safety, September Initial Assessment of the Impact of Jet Flame Hazard From Hydrogen Cars In.
Engineering Analysis of NFPA 285 Tested Assemblies
Page June 2015 OICA position on venting EVSTF-04-11e.
International Conference on Hydrogen Safety 2011 – San Francisco, 12 Sept 2011 Risk informed separation distances for hydrogen refuelling stations Frederic.
A Tire Industry Perspective on Tire Rolling Resistance Tracey Norberg Rubber Manufacturers Association Presentation to the California Energy Commission.
Experimental and numerical studies on the bonfire test of high- pressure hydrogen storage vessels Prof. Jinyang Zheng Institute of Process Equipment, Zhejiang.
Progress report of TFG 7 “Fire resistance test” Mar 19, 2015 Korea Transportation Safty Authority (TS) Korea Automobile Testing & Research Institute (KATRI)
4.1.2 Student Book © 2004 Propane Education & Research CouncilPage Determining System Load and Customer Demand Profile Designing a satisfactory.
Progress report of TFG 7 “Fire resistance test” (rev.1) Nov 19, 2014 Korea Transportation Safty Authority (TS) Korea Automobile Testing & Research Institute.
3.1.8 Student Book © 2004 Propane Education & Research CouncilPage Identifying Procedures for Conducting Container Vapor Flaring Operations Before.
SAFETY WITH CRYOGENIC SYSTEMS. Safety aspects 1. Physiological 2. Suitability of materials and construction 3. Explosions and flammability 4. Excessive.
NFPA 2 Overview Susan Bershad, Staff Liaison, NFPA.
Recent and future research for the fire safety of hydrogen-fueled vehicles in JARI Appearance of Hy-SEF.
Department of Transportation U.S. DOT National Highway Traffic Safety Administration Research & Development/Studies SGS-1-2.
HOT WATER Understand and apply domestic hot water system installation and maintenance techniques.
Boiler Safety Valve Regulations
Korea Automobile Testing & Research Institute Korea Transportation Safety Authority 1 1 정 혁 책임연구원 Korea Automobile Testing and Research Institute(KATRI)
Working group meeting 07/05/15. Agenda Overview of review and current action list Relief system – Summary of problem – Details of analysis, testing and.
WORKING DRAFT HFCV GTR Work assigned on page 20:
WORKING DRAFT HFCV GTR Work assigned on page 20:
Component Availability Effects
Yohsuke Tamura, Koji Yamazaki, Kiyotaka Maeda and Kenji Sato
Egle Rackauskaite, Catherine Hamel, Angus Law, Guillermo Rein 
ICHS - October 2015 Jérôme Daubech
Risk Reduction Potential of Accident Mitigation Features
Sandia National Laboratories
Korea Research Results “Fire resistance test”
Risk informed separation distances for hydrogen refuelling stations
Investigation of pipeline failure
Risk informed separation distances for hydrogen refuelling stations
The Analysis of Fire Test for the High Pressure Composite Cylinder
Brian Somerday Sandia National Laboratories Livermore, CA, USA
Supplemental Test for Determination of CO2 Emissions under Regional Conditions Results from Telco Oct. 30th, 2014 (Iddo, Markus, Helge, Andreas)
Presentation transcript:

DEVELOPING FIRE TESTS FOR FCV AND HYDROGEN VEHICLES Glenn Scheffler Consultant for the US Department of Energy August 2010 DEVELOPING FIRE TESTS FOR FCV AND HYDROGEN VEHICLES SGS-10-08

Compressed Hydrogen Storage System (CHSS) Container Vessel Container Isolation Valve Fill Check Valve Excess flow Receptacle with check Full System Isolation Low Pressure Regulator PRV High Pressure Regulator Downstream Hydrogen Piping for delivery to Fuel Cell System or Engine PRD Service Defuel Shufoff vent Compressed Hydrogen Storage System REQUIREMENT The PRD needs to activate and vent contents during fires before the hydrogen container is weakened and bursts. CONCERN Localized fires can weaken the container before PRDs are activated.

OVERVIEW  Transport Canada and NHTSA conducted research on localized fire test:  Phase I: Study on current fire safety standards for containers; vehicle fire characterization, localized fire profile and test procedures.  Phase II: Refined/simplified the test procedures and study on mitigation technology.  The research data is being used by industry to formulate localized fire test requirements and procedures.  Defining the test article  Establishing the test conditions  Conducting the test

Two options are provided to the manufacturer for flexibility: 1.Generic (Non-specific) Vehicle Installation  Allows only shields and features that are attached to the vessel or system  Size of fire set to 250mm long, covering the full diameter  Direction and location of fire set to maximize distance from PRD(s). 2. Vehicle-specific Installation  Allows for thermal shields and features that are part of the vehicle  Vehicle features may require reduction in generic fire size.  Direction and location of fire based on the vehicle Information on this page is still under development by industry members and organizations and should not be used until officially approved and published. LOCALIZED FIRE TEST Defining the Test Article

Vehicle Fire Tests  Vehicle fire tests conducted  By JARI and US manufacturers  Passenger vehicles, SUVs, and vans tested  Different fires origins investigated  Passenger compartment  Trunk  Wheel wells  Pool fires beneath vehicle  Representative localized fire test conditions were established based on data provided. LOCALIZED FIRE TEST Establishing Test Conditions

Vehicle Fire Test Configurations Case Number Vehicle Type Window Position Fire Initiation Location Container Location In Vehicle 1SSedanOpenCabinIn Trunk 2SSedanOpenTrunk In Trunk 3SSedanClosedTireIn Trunk 4VVanOpenCabinUnder Front Floor 5VVanOpenCabinUnder Rear Floor 6VVanCloseCabinUnder Front Floor 7VVanCloseCabinUnder Rear Floor 8VVan

Vehicle Fire Tests 1) About 40% of the fires investigated resulted in localized fire conditions before conventional PRDs on end bosses would have activated. 2) While vehicle fires often lasted minutes, the period of localized fire degradation on the storage containers lasted less than 10 minutes. See figure on next page. 3) The average maximum temperature during the localized fire period was less than 570°C with peak temperatures reaching approximately 600°C in 2 cases and 880°C in one case. See figure in two pages. 4) The rise in peak temperature near the end of the localized fire period often signaled the transition to an engulfing fire condition. S Key Findings from Vehicle Fire Tests

Time of Potential Localized Degradation Based on degradation starting above 300°C on container and ending when end-boss PRDs activate Time of Localized Degradation (min) Vehicle Fire Test Cases (None)

Average and Peak Temperatures During Localized Fire Degradation Temperature (C) Vehicle Fire Test Cases

Vehicle Fire Tests  8-10 minutes of localized fire exposure on the test article required to cover test experience.  The selection of 600°C as the minimum exceeds the average localized temperature for all test cases.  Given that test experience indicates the controllability of the fire will be approximately ±100°C in outdoor situations, the peak temperatures expected during the proposed test will also agree favorably with test results. S Rationale for Constructing the Localized Fire Temperature Profile

Minimum Temperature Profile being Considered for the Localized Fire Test ° C Localized Fire Engulfing Fire Time (minutes) 10 Region of localized impact Regions of localized and engulfing fire impact (1.65m max length) 600° C

Vehicle Fire Tests  LPG fuel selected for the test burner  Fast response  Provides controllability and repeatability  The LPG burner for the localized fire region is lit.  The minimum temperature profile is followed.  Temperature in regions outside the localized fire are not specified and will vary naturally based on thermal characteristics of the container, thermal shields, and barriers.  Test continues until the PRD activates. If necessary, the test progresses to the engulfing fire.  Vessel burst (or significant leak) constitutes failure! LOCALIZED FIRE TEST Conducting the Fire Test

Vehicle Fire Tests  The “standard” engulfing fire test is still required if vehicle- specific features are utilized for the new localized fire test.  Verification needed of the test method. LOCALIZED FIRE TEST Other Considerations