I NDUCTION T ECHNOLOGY C ORPORATION Complete 750 kW, 1 kHz Induction Melting System - Includes (2) 2000 lb. box furnaces & Power Supply.

Slides:



Advertisements
Similar presentations
ACTIVE LEARNING PROCESS
Advertisements

I NDUCTION T ECHNOLOGY C ORPORATION 450 kW Ajax Induction System with 10,000 lb. Channel Furnace.
MEDIUM VOLTAGE VFD MOTOR CONTROLLER Liquid Cooled Components Active Front End - No Transformer 3300 – 6900 VAC 700 – 2500 HP Contact:
1 S. Lusin, LV Cabling, CERN 06 Apr 06 LV Cabling 06 Apr 06 S. Lusin Fermilab / CERN Cabling from USC to UXC, Power Distribution.
Rebuilding process for the Box Type Induction Furnace.
CONTENTS Our Customer Partners Us Our Products Quality Policy & Standards.
1 ELECTRICAL EQUIPMENT AND SYSTEMS – OFFSHORE AND ONSHORE FACILITIES MAIN ELECTRICAL EQUIPMENTS AND SYSTEMS INSTALLED  GENERATORS: MAIN GENERATORS – 12.
AP1000 Chilled Water System
Delta Confidential Apr GAIA-series 5-11KVA Introduction.
Flowtech 856/2, G.I.D.C. INDL. ESTATE, MAKARPURA ROAD, BARODA – , PHONE : , TELEFAX :
Franz Frank (ABB Switzerland Ltd) – PowerGen Europe 2010
HVAC Systems Overview HVAC Overview - # 1 Tom Lawrence
The 30M2 Continuous Miner. Customer Name 30M2 Overview %Heavy duty high power miner for mid-height seams %High productivity from efficient cutting and.
Czochralski Growth. Example 10% at. Al in Si I M = 10% I S = 1% k = 0.1.
Overview of Phobos Magnet Designed by Harald Enge Built by Danfysik Technical summary: –“Double dipole” design –15.5 cm air gap –Max. 2 Tesla field –378.
ERT 105 ELECTRICAL ENGINEERING THREE PHASE SYSTEM (week 8-9) THREE PHASE SYSTEM (week 8-9)
Make the most of your energy December 2008 PowerLogic Enercept Submetering ….when space is at a premium PowerLogic® Enercept Meter.
Inductors. Inductance Electrons in motion create electromagnetic fields – Recall from previous section that electrons in motion also create an electrostatic.
Current status Arkadiy Klebaner November 21, 2012
1 HVAC 214 Electricity For Oil Heat Fan Center Relays.
American Control Technologies,Inc Power Factor Correction Technology 1152 West 2400 South Suite ‘C’ Salt Lake City, Utah
1 as Air Conditioning Systems. 2 as Split Type Air-Cooled Suction Line Liquid Line Condensing Unit (CDU) : Fan Coil Unit (FCU) : MCW,MCX,MCD,MCC,MCV,TTH,TWE,TTV.
Learning, our way Exercise Water pipe, Pump and Cooling Tower Selection.
ENERGY CONSERVATION BUILDING CODE – 2006 PRESENTATION BY VP GUPTA PRINCIPAL CHIEF ENGINEER (ELECTRICAL), BSNL CHENNAI.
© 2006, ZTE Corporation. All rights reserved.   E300 Series Mini-type Integrated Universal Inverter.
Booster Bias Supply Upgrade January 18 th, Ferrite Bias Supply Testing  Four thermocouples added to MADC  Monitoring: center winding, core, input.
Introduction Topic: The Basic Ground Source Heat Pump Name: Matthew Stoangi Objective: To provide a clear understanding of the mechanics involved in the.
ROUND THE WORLD ROUND THE CLOCK v2a – S&S EaA External 28-Mar-2006 DMA Fuel Change-over and MGO Cooling System For Retrofit and Newbuilding REV
Update on the SEEM Simulation Program Larry Palmiter and Ben Larson August 4, 2008 Ecotope Inc. Presented at Regional Technical Forum Portland, Oregon,
MonoDrive & XT Constant Pressure Controller
1. Bucket capacity42m 3 Operating weight720,000 kg PC8000 Bucket capacity0.008m 3 Operating weight300 kg PC01 Product Range (Hydraulic Excavators) 2.
Inputs/Givens 1.Volume of Ice (3.5 gal) 2.Density of Ice (736 kg/m 3 ) 3.Latent Heat of Ice, h sf (333.6 KJ/kg) 4.Melt time of 1 hour (3600 s) Constraints.
Lecture Objectives: Specify Exam Time Finish with HVAC systems –HW3 Introduce Projects 1 & 2 –eQUEST –other options.
1 11/17/2015 Power Quality Correction. 2 11/17/2015 Power Quality Correction.
SC Project Review of NCSX, April 8-10, 2008 NCSX Cryogenics Systems WBS-62 Steve Raftopoulos NCSX Cryogenic Systems WBS(62)
MF Pad Considerations. Date: June 9, Hz Power Converter –The 400-Hz connectors installed on power pop-ups: The part number for the 400-Hz connector.
Three Phase Motors Maths
Current transformers (CTs)
取扱注意情報 Development of a valved non-lubricated linear compressor for compact 2K Gifford-McMahon cryocoolers March 8, 2016 Y. Hiratsuka, Q. Bao and M. Xu.
Overall Main Components [Electric Power Path] : AC : DC
Wholesale Medium Voltage Drives
High Voltage modulators ESS developments Carlos A. Martins ESS Accelerator Division, RF electrical power systems.
Invention House Overview. When…. Is not the answer…
Programmable Logic Controller (PLC) - Hardware and Software Lecture 12.
ELECTRICAL DEPARTMENT ELEMENT OF ELECTRIC DESIGN
Fan Coil Controller FC/S 1.1
Design, Evaluation and Application of a Fuel Cell Vehicle
P1 Formulas and Questions.
APPLICATIONS Designed and manufactured to meet the needs for constant pressure required by modern plumbing systems, such as : Domestic applications and.
New 10kW CAC & NCAC High wall unit.
Frese Delta T Introduction Introduction 2017.
There are three parts of a transformer
The Ointment Manufacturing Plants are ideal tools for the production of Ointment, Cream, Lotions, Tooth Paste & other emulsions & homogenizations.This.
Production product catalog
Construction and Commissioning of Electronic Test Benches
Introduction to W7-X Coil Testing at CEA – Saclay, France
SPOC Automation and BECI- who are we?
Welcome A presentation on Kothaloni OCS & GCS by Dhritiman Nath
Electrical Machine-I EE 2107 Dr. Md. Sherajul Islam
FCL FCL.
FCI and FCX Range FCI and FCX Range.
Transformers A transformer changes the high voltage from the main power lines to the 120 volts your appliances use.
Axial Booster Fan System
FCI and FCX Range FCI and FCX Range.
FCI and FCX Range FCI and FCX Range.
Systems Practice Use the next slide in this powerpoint as a template to identify 10 different types of systems. 4 of your slides need to be natural systems.
Lineup (ATW) <2018> <2019> : New series Series Ref. Split
Systems Practice Use the next slide in this powerpoint as a template to identify 5 different types of systems. 2 of your slides need to be natural systems.
Auto Winch Machine September 2014 Marketing Department.
PRESENTATION CONTENT INTRODUCTION USES DESIGN POTENTIAL STOCKISTS
Presentation transcript:

I NDUCTION T ECHNOLOGY C ORPORATION Complete 750 kW, 1 kHz Induction Melting System - Includes (2) 2000 lb. box furnaces & Power Supply

Complete system consists of:  750 kW, 1 kHz Inductotherm VIP Power supply  (2) 2000 lb. capacity box melting furnaces  Complete water cooling and recirculation system  All interconnecting buss & power cables  Lots of additional parts and accessories

Power Input Rating:  815 KVA  1,023 A  460 V  3 PH  60 Hz Power Output Rating:  750 kW  1,200 Hz  3,000 V

(2) 2000 lb. hydraulic tilt box furnaces with hydraulic lids

Furnace Accessories Include:  Hydraulic power pack  Water-Cooled Power Cables  Spare Coil  (1) Graphite crucible  (1) Silicon Carbide crucible

Complete External Closed Loop Water Cooling and Recirculation System:  (2) Liebert Dry Type Fluid Coolers with 6 fans each  5 Hp Water Pump Skid with (1) main & (1) backup pump  Compact Motor Control Center

(2) Delta Y Line Isolation Transformers with electrostatic shields and switchgear 12470/460 Volt 850/977 KVA 480/480 Volt 990 KVA

This complete induction melting system is ideal for any new start-up or expansion operation.  Complete system is ready for installation and assembly in buyer’s facility.  System is used, and in excellent condition.

For more information please call our sales department at Or send an to