1 04/18/06 Titmusi400 Vision Screener User Training.

Slides:



Advertisements
Similar presentations
Use lenses to direct light in order to enlarge images
Advertisements

OPERATION AND MAINTENANCE
How to Care For and Use the Microscope
Work Improvement in Small Enterprises (WISE): good examples from Asia [CD-ROM] [Publications] Compilation of PowerPoint presentations on: 1) Work station.
Cable Probe. Safety First System can conduct electricity Do not use in flammable atmosphere Use proper personal protective equipment.
1.Cable management cover ( cpu only ) 2.Wired barcode scanner holder (optional) 3.Mouse holder and tray 4. Removable rear technology panel 5. Power cord.
Welcome to your Phaser 4600 printer
Color Printer Training
 Without reference, identify principles relating to Fixed Radiological X-RAY PM with at least 70 percent accuracy.
Use of the Spectronic 20 Spectrophotometer
CLINITEK Status® Plus UACR Operator Training Program
2 Fire Fighter Qualifications and Safety Skill Drills.
Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.
Digital StarLab Set-Up, Operation, Maintenance, and Teacher Manual for the Digital StarLab are in the links below or on the training tab in the BlackBoard.
1 Microscope Maintenance. Microscope Maintenance-Module 3 2 Learning Objectives At the end of this module, you will be able to Store the microscope properly.
1 Module 9: Microscope Maintenance. 2 Learning Objectives Learning Objectives At the end of this module, you will be able to Store the microscope properly.
Medication Assistant Training Module 5 Eyes Ears Nose.
Laptop mobile work station. Laptop mobile work station with drawers.
Microscope Lab Objectives Identify the parts of dissecting and compound light microscope and give their functions. Coordinate their use to accurately.
Welcome to Swinburne Online! You are an integral part of our team and we want to ensure that whilst working from home your safety is our Number 1 priority.
Service Seminar Memory Craft Table of Contents MC10001 Top Cover Removal…………………………………………………………………..…………1 Belt Cover Removal……………………………………………………………..……………2-4.
Introduction to the oil immersion compound microscope
UC Davis Safety Services Monthly Safety Spotlight February 2010: Computer Work Station Ergonomics Safety Discussion Topics Work Station Ergonomics Tips.
Portable Camera Operations1 Audio/Video Production 1 Portable Camera: Precautions and Operation.
Computer Workstation Ergonomics Checklist HLTH 2115 AAWC.
1 Office Ergonomics Grand Valley State University Occupational Safety and Health Program.
MC11000 Kit Replacement 1 1. Open the face plate and remove the 2 screws. Remove and discard the original face plate. 3. Remove the 2 white caps on the.
Compound Light Microscope
Paychex Safety And Loss Control
Introduction to the Binocular Microscope
Introduction to the Microscope
THE MICROSCOPE
Removing and Replacing the Battery Cover 1. Ensure the phone is turned off. 2. Press the Battery cover locker; lift the battery cover up and away from.
Methods of measuring intra ocular pressure. What is intra ocular pressure ? Definition Intra ocular pressure refers to the pressure exerted by the intra.
Ergonomics. What is Ergonomics ? It is... fitting the work to the worker Ergon = Greek for “work” Nomos = Greek for “laws of” The Study of Work Applies.
Set Up for Live Streaming Video This presentation will walk you through the set up and delivery for streaming video of a live event over the internet.
( er- goe- nuh- mix). Ergonomics What is Ergonomics ? man and machines  It is the study of how man and machines work together comfortable  It is the.
Microscopes are tools used to enlarge images of small objects so as they can be studied.
Introduction to the Microscope  Care  Parts  Focusing.
Note to teacher: Use these slides along with the student handouts and guided notes on parts of a microscope, care & handling and how to use a microscope.
* Care * Parts * Focusing - Always carry with 2 hands …one on the arm and the other on the base - use lens paper for cleaning - Clean after using immersion.
1 Injury Prevention & Body Mechanics 2012 Mary Ellen Lesperance Karmanos Cancer Center.
A AN NIGHT VISION DEVICES
Electronic Office Procedures
This is an example of typical workstation ergonomics. For computer workers this is very important and there are 10 important points to remember.
Charging Cart Instruction & User Manual EnTrans Technology Co., Ltd.
Microscopes Biology I. Magnification 1. Power a microscope has to increase an objects size.
Care and Use of the Compound Microscopes Moorpark College Biology Department.
MICROSCOPE A compound microscope is an expensive precision instrument that requires special care and handling. let’s learn the parts of a compound microscope,
The Microscope Proper Care and Use. Microscopes are an important part of the physician’s office. They are instrumental for diagnosing such things as urinary.
Coleg Gwent Ergonomics. Coleg Gwent What does it mean?
Charging Cart Instruction & User Manual EnTrans Technology Co., Ltd.
Autorefractor Instructions. Seat the patient at the instrument. Hold and stabilize the chair as the patient sits down, especially if the chair has wheels.
Introduction to the Microscope  Care  Parts  Focusing.
HANDLING, OPERATION & CARE OF THE LIGHT COMPOUND MICROSCOPE PRACTICAL 1.
Keratometry and Corneal Topography Instructions. Generally the keratometer & corneal topographer are combined into one instrument that does each reading.
Copyright © 2016 by The S.E.A. Group
An introduction to the Compound Light Microscope (This is a note check, for p. 3) You must make sure you have these correct for studying them later.
How to Set up Your Computer Workstation
Desk Ergonomics.
PRACTICAL 1 BY NANA ABOAGYE ACHEAMPONG
Module 9: Microscope Maintenance
Installing the SIM CARD and Battery
Call to Fix Dell Printer Error Code
Light Microscope: – light passes through one or more lenses to produce an enlarged image of a specimen compound light microscope – light microscope that.
Light Microscope: – light passes through one or more lenses to produce an enlarged image of a specimen compound light microscope – light microscope that.
Beginner Stander Presentation
MICROSCOPES.
Light Microscope: – light passes through one or more lenses to produce an enlarged image of a specimen compound light microscope – light microscope that.
Presentation transcript:

1 04/18/06 Titmusi400 Vision Screener User Training

2 04/18/06 Overview Introduction Step 1 - Unpacking the vision screener Step 2 - Review Features Step 3 - Testing Far / Near vision testing Patient Seating Height Adjustment Step 4 - Care and Maintenance

3 04/18/06 Titmusi400 Vision Screener Introduction

4 04/18/06 The TITMUSi400 Vision Screener ONE instrument with a variety of screening tests Device with controlled test distance for FAR / NEAR vision, hence precision and accuracy Simple to learn and user-friendly Can complete a comprehensive tests in 5-10 minutes Many more tests and better control as compared to a wall chart

5 04/18/06 TITMUSi400 Features Ergonomics – proper position while testing Membrane panel for ease of testing Built-in Portability New Fluorescent Light Source – long life Electronic sensing of correct head position Foam Headrest – no more head rest tissues (paper) Many advantages over the earlier Models (OV7, TII, T2)

6 04/18/06 Titmusi400 Vision Screener Step 1: Unpacking

7 04/18/06 Unpacking If received in case, remove instrument from case using handle Unlock the handle (use BOTH hands)

8 04/18/06 Unpacking Unlock bottom lock using one hand to pull tab and other hand to raise instrument Lift and remove membrane panel. Not tabs to mount back

9 04/18/06 Unpacking Remove internal packing foam Turn knobs so that white dot matches purple dot (USE BOTH HANDS TO TURN KNOBS)

10 04/18/06 Titmusi400 Vision Screener Step 2: Review Features

11 04/18/06 TITMUSi400 – External Features Handle for transport Top Cover to access slides Slot for plus lens Lever for Far/near lens Foam Headrest Electronic head sensor Lens for Far/Near Handle unlock Knob to raise/lower instrument Instrument unlock Side pocket

12 04/18/06 TITMUSi400 – External Features A.Membrane Panel B.Handle C.Fuse D.ON/OFF switch

13 04/18/06 TITMUSi400 – Membrane Panel A.Bulb condition indicator B.Peripheral vision screening C.Day/night illumination D.Test slide advance/reverse E.Slide position indicators F.Reset G.Head position indicator, sensor deactivate H.Left/Right eye occlusion (activate shutters) I.Test distance indicator (far/near/intermediate)

14 04/18/06 Titmusi400 Vision Screener Step 3: Testing

15 04/18/06 Operating Far/Near Lever Operator can sit on any side of instrument Pull to move far/near lever towards you, push away to move away from you FAR (mountain), NEAR (book)

16 04/18/06 Far Vision Testing Lever in FAR position Ensure drum assembly is in FAR position. White dot on knob should match purple dot

17 04/18/06 Near Vision, Natural Line of Sight Lever in NEAR position, test at optimal line of sight Turn BOTH knobs so the progressive lens wearer can see most clearly (natural line of sight – looking downwards)

18 04/18/06 Using intermediate lens Ensure lever is in FAR position Place intermediate lens with label facing the front DO NOT turn knob when int. lens is in the instrument

19 04/18/06 Patient Seating Ensure patient is comfortably seated – straight back, forehead placed on headrest INCORRECT position – back not straight, neck tilted backwards

20 04/18/06 Patient Seating Patient correctly seated will activate the head sensor When head sensor is activated, slides can be seen (clicking sound of the shutters opening) If a patient tends to move his/her head a lot, shutters will open/close. In this case, override the sensor

21 04/18/06 Height adjustment Instrument is designed for patient comfort in order to test efficiently and accurately Can fit children or adults, standing or seated To raise/lower the instrument – use BOTH hands on the knobs

22 04/18/06 Preparation for testing 1.Place instrument on table of sufficient height 2.Unlock handle, bottom lock and raise instrument 3.First connect panel to instrument as shown using panel cord. Then connect power cord to instrument and turn switch ON. 4.Test all membrane switches on membrane panel to ensure proper operation 5.Ensure lenses are clean, use cleaning towlettes or fog cloths

23 04/18/06 Preparation for testing 6.Place record forms near instrument 7.Avoid positioning the instrument near strong glaring light to prevent glare while testing 8.Ensure patient is comfortably seated 9.Raise the instrument for comfortable viewing, based on patient height 10.Ensure lever is in FAR position 11.Ensure drum assembly is in FAR position. White dot on knob should match purple dot.

24 04/18/06 Titmusi400 Vision Screener Step 4: Care and Maintenance

25 04/18/06 Care and Maintenance Clean viewing lenses as needed, use towlettes supplied in accessory case Clean headrest between tests using a disinfectant solution.

26 04/18/06 Care and Maintenance Exterior of instrument may be cleaned with a soft cloth dampened in mild solution of soap and water Test slides are in a completely enclosed module, hence cleaning is rarely required Use dust cover to protect instrument when not in use Slide illumination lamp has a life of over 10,000 hours. Membrane panel will indicate if it needs replaced.