CAL DQM REPORT T. Schörner-Sadenius Hamburg University CAL/HES Meeting, 4 January 2005
ZEUS Week Padova 10/2004TSS: CAL Overview and DQM2 HAPPY NEW YEAR! Let’s hope for a working CAL and for lots of lumi. Unfortunately recently many problems – see later
ZEUS Week Padova 10/2004TSS: CAL Overview and DQM3 A loose collection of incidents Took over from Michele Sunday 20/12/04. CAL in reasonably good shape with 295 bad channels (calibration version 3852). However, problem in time offsets version – please always stick to the calibration procedures as posted on the web! 21/12/04 10am: FEC v3855 (297/0) 21/21/04 1pm: power glitch! 21/12/04 5pm: BC update v3856 (428/7) 23/12/04: BC update (452/9) 27/12/04: FEC v3861 (282/1) … and then a few more problems appeared ;-(
ZEUS Week Padova 10/2004TSS: CAL Overview and DQM4 A loose collection of incidents ctd’ 28/12/04 morning: CALDAQ (telamon) PC broken Backup system for teucer/ajax Many DQM processes (HIP, cronjobs, …) Alessandro (with Kerstin and Ulf): Move everything to menelaus (which is now also called caldaq/telamon – still problems with the names – you have to login to telamon). By now everything seems to be back, but our HV monitoring and HIP histograms suffered for some time loss of about 300k events! Various CQC runs with various problems R23 not filled (we had that before – TLT problem?) B22 HV off did not use a number of these runs for BC updates.
ZEUS Week Padova 10/2004TSS: CAL Overview and DQM5 A loose collection of incidents ctd’ Current situation V3864 (314/2) DQM monitoring back (got the first SMS this morning ;-( )
ZEUS Week Padova 10/2004TSS: CAL Overview and DQM6 Recent Problems See new SOS page with a collection of recent problems and their solution: www-zeus.desy.de/components/CAL/ZEUS_ONLY/troubleshooting/sos-problems.html Problems B21/22 off swithc back on (and control with UNO run) CAL DAQ broken HIP not updating restart readout (HIP server?) FCAL UNO bad channels because of beam situation ? Timing shift by ~50ns shake CFLTP-Nevis cable. DQM browser alarms for HV and online analysis jobs???? Local RC stuck delete all lock files and kill all cal_rc processes (careful!)
ZEUS Week Padova 10/2004TSS: CAL Overview and DQM7 Recent Problems: B22 off!
ZEUS Week Padova 10/2004TSS: CAL Overview and DQM8 New Web Tools Zmon online In analogy to DQMCOC on the web cal_check procedure should become simpler for the oncall person References not yet there Calibration version cgi script New SOS collection New page layout Timing history script with link HV history script with link Please give feedback on the web pages and the tools.
ZEUS Week Padova 10/2004TSS: CAL Overview and DQM9 New Web Tools: ZMON
ZEUS Week Padova 10/2004TSS: CAL Overview and DQM10 New Web Tools: Version script
ZEUS Week Padova 10/2004TSS: CAL Overview and DQM11 New Web Tools: Timing and HV
ZEUS Week Padova 10/2004TSS: CAL Overview and DQM12 Important for all oncall persons: Please stick to the procedures as defined on the web. Where the definition is not so clear I will try to improve very soon Most important: Before each FEC/ADC-to-volts calibration or trimming: update the bad channels and really change to the new calibration versions after the BC update!!! Reason: Time structure of GAFs! I will create new web pages for all possible actions with very detailed instructions: BC update ADC-to-volts calibration Trimming FEC FEC after an access
ZEUS Week Padova 10/2004TSS: CAL Overview and DQM13 Example for FEC instruction
ZEUS Week Padova 10/2004TSS: CAL Overview and DQM14 Access Day Tomorrow Change 3 SRTD front-end cards (Roberval/Wladimir) Change 4 FCAL front-end cards (TSS/Wladimir) Have another look at B16 (Bill?) HES? … ?