Chapter 14 Frequency Response Force dynamic process with A sin  t, Chapter 14 14.1 1.

Slides:



Advertisements
Similar presentations
Control System Design Based on Frequency Response Analysis
Advertisements

Stability Margins Professor Walter W. Olson
Chapter 4 Modelling and Analysis for Process Control
Chapter 10 Stability Analysis and Controller Tuning
Nyquist Stability Criterion
Chapter 10: Frequency Response Techniques 1 ©2000, John Wiley & Sons, Inc. Nise/Control Systems Engineering, 3/e Chapter 10 Frequency Response Techniques.
Frequency Response Techniques
Nyquist Plot – First Order Lag
Automatic Control By Dr. / Mohamed Ahmed Ebrahim Mohamed Web site:
Lecture 8B Frequency Response
CHE 185 – PROCESS CONTROL AND DYNAMICS
Automatic Control Theory School of Automation NWPU Teaching Group of Automatic Control Theory.
Analysis of SISO Control Loops
Control System Design Based on Frequency Response Analysis
Frequency Response Methods and Stability
Controller Tuning: A Motivational Example
Dr. / Mohamed Ahmed Ebrahim Mohamed Automatic Control By Dr. / Mohamed Ahmed Ebrahim Mohamed Web site:
LINEAR CONTROL SYSTEMS Ali Karimpour Assistant Professor Ferdowsi University of Mashhad.
Lecture 7: PID Tuning.
سیستمهای کنترل خطی پاییز 1389 بسم ا... الرحمن الرحيم دکتر حسين بلندي - دکتر سید مجید اسما عیل زاده.
Control System Design Based on Frequency Response Analysis
Chapter 5 Frequency-Domain Analysis
Automatic Control System
Unit 5: Feedback and control theory An Introduction to Mechanical Engineering: Part Two Feedback and control theory Learning summary By the end of this.
2-1 (a),(b) (pp.50) Problem: Prove that the systems shown in Fig. (a) and Fig. (b) are similar.(that is, the format of differential equation is similar).
Automatic Control Theory School of Automation NWPU Teaching Group of Automatic Control Theory.
DYNAMIC BEHAVIOR AND STABILITY OF CLOSED-LOOP CONTROL SYSTEMS
Chapter 13 1 Frequency Response Analysis Sinusoidal Forcing of a First-Order Process For a first-order transfer function with gain K and time constant,
Frequency Response OBJECTIVE - Bode and Nyquist plots for control analysis - Determination of transfer function - Gain and Phase margins - Stability in.
Controller Design (to determine controller settings for P, PI or PID controllers) Based on Transient Response Criteria Chapter 12.
Automatic Control Theory School of Automation NWPU Teaching Group of Automatic Control Theory.
INC 341PT & BP INC341 Frequency Response Method (continue) Lecture 12.
1 Chapter 5 Sinusoidal Input. 2 Chapter 5 Examples: 1.24 hour variations in cooling water temperature Hz electrical noise (in USA!) Processes are.
PID Controller Design and
Chapter 11 1 Stability of Closed-Loop Control Systems Example 11.4 Consider the feedback control system shown in Fig with the following transfer.
Fundamentals of PWM Dc-to-Dc Power Conversion Dynamic Performance of PWM Dc-to-Dc Converters.
Automatic Control Theory School of Automation NWPU Teaching Group of Automatic Control Theory.
Frequency Response OBJECTIVE - Bode and Nyquist plots for control analysis - Determination of transfer function - Gain and Phase margins - Stability in.
Chapter 10 Frequency Response Techniques Frequency Response Techniques.
Chapter 6: Frequency Domain Anaysis
Control System Design Based on Frequency Response Analysis
Frequency Response Analysis and Stability
Ch. 13 Frequency analysis TexPoint fonts used in EMF.
ChE 182 Chemical Process Dynamics and Control
Feedback Controllers Chapter 8
Root Locus Method. Root Locus Method Root Locus Method.
Lecture 21: Intro to Frequency Response 1.Review of time response techniques 2.Intro to the concept of frequency response 3.Intro to Bode plots and their.
Control Systems Engineering, Fourth Edition by Norman S. Nise Copyright © 2004 by John Wiley & Sons. All rights reserved. Figure 10.1 The HP 35670A Dynamic.
Lecture 10 Feedback Control Systems President UniversityErwin SitompulFCS 10/1 Dr.-Ing. Erwin Sitompul President University
Signals and Systems, 2/E by Simon Haykin and Barry Van Veen Copyright © 2003 John Wiley & Sons. Inc. All rights reserved. Figure 9.1 (p. 664) Two different.
ABE425 Engineering Measurement Systems ABE425 Engineering Measurement Systems PID Control Dr. Tony E. Grift Dept. of Agricultural & Biological Engineering.
1 Chapter 9 Mapping Contours in the s-plane The Nyquist Criterion Relative Stability Gain Margin and Phase Margin PID Controllers in the Frequency Domain.
Feedback Control System THE ROOT-LOCUS DESIGN METHOD Dr.-Ing. Erwin Sitompul Chapter 5
Automated Control Systems, 8/E by Benjamin C. Kuo and Farid Golnaraghi Copyright © 2003 John Wiley & Sons. Inc. All rights reserved. Figure 9-1 (p. 354)
Control System Design Based on Frequency Response Analysis
Time Domain and Frequency Domain Analysis
Nyguist criterion Assist. Professor. Dr. Mohammed Abdulrazzaq.
DNT Control Principle Frequency Response Techniques DNT Control Principle.
Frequency-Domain Analysis and stability determination
Control System Analysis and Design by the Frequency Response Method
Frequency Response Analysis
Frequency Response Techniques
Nyquist Stability Criterion
Frequency Domain specifications.
Closed-Loop Frequency Response and Sensitivity Functions
Time-domain vs Frequency -domain?
PID Controller Design and
Frequency Response Techniques
Frequency Response Analysis
The Frequency-Response Design Method
Presentation transcript:

Chapter 14 Frequency Response Force dynamic process with A sin  t, Chapter

Input: Output: is the normalized amplitude ratio (AR)  is the phase angle, response angle (RA) AR and  are functions of ω Assume G(s) known and let Chapter 14 2

Example 14.1: K 1 K 2 Chapter 14 3

4

(plot of log |G| vs. log  and  vs. log  ) Use a Bode plot to illustrate frequency response log coordinates: Chapter 14 5

Figure 14.4 Bode diagram for a time delay, e -  s. Chapter 14 6

Example

The Bode plot for a PI controller is shown in next slide. Note  b = 1/  I. Asymptotic slope (  0) is -1 on log-log plot. Recall that the F.R. is characterized by: 1. Amplitude Ratio (AR) 2. Phase Angle (  ) F.R. Characteristics of Controllers For any T.F., G(s) A) Proportional Controller B) PI Controller For Chapter 14 8

9

Series PID Controller. The simplest version of the series PID controller is Series PID Controller with a Derivative Filter. The series controller with a derivative filter was described in Chapter 8 Chapter 14 Ideal PID Controller. 10

Figure 14.6 Bode plots of ideal parallel PID controller and series PID controller with derivative filter (α = 1). Ideal parallel: Series with Derivative Filter: Chapter 14 11

Advantages of FR Analysis for Controller Design: 1. Applicable to dynamic model of any order (including non-polynomials). 2. Designer can specify desired closed-loop response characteristics. 3. Information on stability and sensitivity/robustness is provided. Disadvantage: The approach tends to be iterative and hence time-consuming -- interactive computer graphics desirable (MATLAB) Chapter 14 12

Controller Design by Frequency Response - Stability Margins Analyze G OL (s) = G C G V G P G M (open loop gain) Three methods in use: (1) Bode plot |G|,  vs.  (open loop F.R.) - Chapter 14 (2)Nyquist plot - polar plot of G(j  ) - Appendix J (3)Nichols chart |G|,  vs. G/(1+G) (closed loop F.R.) - Appendix J Advantages: do not need to compute roots of characteristic equation can be applied to time delay systems can identify stability margin, i.e., how close you are to instability. Chapter 14 13

Chapter

Frequency Response Stability Criteria Two principal results: 1. Bode Stability Criterion 2. Nyquist Stability Criterion I) Bode stability criterion A closed-loop system is unstable if the FR of the open-loop T.F. G OL =G C G P G V G M, has an amplitude ratio greater than one at the critical frequency,. Otherwise the closed-loop system is stable. Note: where the open-loop phase angle is Thus, The Bode Stability Criterion provides info on closed-loop stability from open-loop FR info. Physical Analogy: Pushing a child on a swing or bouncing a ball. Chapter 14 15

Example 1: A process has a T.F., And G V = 0.1, G M = 10. If proportional control is used, determine closed-loop stability for 3 values of K c : 1, 4, and 20. Solution: The OLTF is G OL =G C G P G V G M or... The Bode plots for the 3 values of K c shown in Fig Note: the phase angle curves are identical. From the Bode diagram: Chapter 14 16

Figure 14.9 Bode plots for G OL = 2K c /(0.5s + 1) 3. Chapter 14 17

For proportional-only control, the ultimate gain K cu is defined to be the largest value of K c that results in a stable closed-loop system. For proportional-only control, G OL = K c G and G = G v G p G m. AR OL (ω)=K c AR G (ω) (14-58) where AR G denotes the amplitude ratio of G. At the stability limit, ω = ω c, AR OL (ω c ) = 1 and K c = K cu. Chapter 14 18

Example 14.7: Determine the closed-loop stability of the system, Where G V = 2.0, G M = 0.25 and G C =K C. Find  C from the Bode Diagram. What is the maximum value of K c for a stable system? Solution: The Bode plot for K c = 1 is shown in Fig Note that: Chapter 14 19

Chapter

Ultimate Gain and Ultimate Period Ultimate Gain: K CU = maximum value of |K C | that results in a stable closed-loop system when proportional-only control is used. Ultimate Period: K CU can be determined from the OLFR when proportional-only control is used with K C =1. Thus Note: First and second-order systems (without time delays) do not have a K CU value if the PID controller action is correct. Chapter 14 21

Gain and Phase Margins The gain margin (GM) and phase margin (PM) provide measures of how close a system is to a stability limit. Gain Margin: Let A C = AR OL at  =  C. Then the gain margin is defined as: GM = 1/A C According to the Bode Stability Criterion, GM >1  stability Phase Margin: Let  g = frequency at which AR OL = 1.0 and the corresponding phase angle is  g. The phase margin is defined as: PM = 180° +  g According to the Bode Stability Criterion, PM >0  stability See Figure Chapter 14 22

Chapter 14 23

Rules of Thumb: A well-designed FB control system will have: Closed-Loop FR Characteristics: An analysis of CLFR provides useful information about control system performance and robustness. Typical desired CLFR for disturbance and setpoint changes and the corresponding step response are shown in Appendix J. Chapter 14 24

Previous chapterNext chapter Chapter 14 25