Events 1. Figure 4 shows: Left panel – Negative values ​​ of the electric field and data of high energy neutrons (upper panel), thermal neutrons (lower.

Slides:



Advertisements
Similar presentations
Cosmic Ray Using for Monitoring and Forecasting Dangerous Solar Flare Events Lev I. Dorman (1, 2) 1. Israel Cosmic Ray & Space Weather Center and Emilio.
Advertisements

Testing of a Cellphone-based Cosmic-ray Detector Network Steven Wright, Zach Irwin, Charlie Steingard, Max Caplow, David Olin, Jesse Silva Wildwood School,
A little E&M review Coulomb’s Law Gauss’s Law Ohm’s Law.
LIGHTNING PHENOMENON 1. The height of the cloud base above the surrounding ground level may vary from 160 to 9,500 m. The charged centres which are responsible.
A Muon Veto for the Ultra-Cold Neutron Asymmetry Experiment Vince Bagnulo LANL Symposium 2006 Outline ● UCNA Experiment ● Muon background ● Proposed Veto.
Cosmic rays in solar system By: Tiva Sharifi. Cosmic ray The earth atmosphere is bombarded with the energetic particles originating from the outer space.
Terrestrial Gamma-ray Flashes. Gamma Ray Astronomy Beginning started as a small budget research program in 1959 monitoring compliance with the 1963 Partial.
Terrestrial gamma-ray flashes Prepared by Morris Cohen Stanford University, Stanford, CA IHY Workshop on Advancing VLF through the Global AWESOME Network.
The new information about UV radiation of the Earth's atmosphere according to the «Universitetskij-Tatiana-2» data D.V.Skobeltsyn Institute of Nuclear.
From Geo- to Heliophysical Year: Results of CORONAS-F Space Mission International Conference «50 Years of International Geophysical Year and Electronic.
RESEARCH RESULTS ON ATMOSPHERIC ELECTRIC FIELD AT OBSERVATORY PARATUNKA IN KAMCHATKA. V.V. Kuznetsov, N.V. Cherneva, G.I. Druzhin, I.Y. Babahanov. Institute.
Atmospheric Electricity. Dalibard’s Experiment The Earth’s Electric Field.
V. M. Sorokin, V.M. Chmyrev, A. K. Yaschenko and M. Hayakawa Strong DC electric field formation in the ionosphere over typhoon and earthquake regions V.
Solar wind-magnetosphere- atmosphere coupling: effects of magnetic storms and substorms in atmospheric electric field variations Kleimenova N., Kozyreva.
ABSTRACT This work concerns with the analysis and modelling of possible magnetohydrodynamic response of plasma of the solar low atmosphere (upper chromosphere,
Radio emissions produced by cosmic- ray extensive air showers traversing thunderclouds Joseph R. Dwyer Department of Physics and Space Sciences Florida.
Radiation conditions during the GAMMA-400 observations:
1 Seasonal variations of the muon flux seen by the muon detector BUST 1 Institute of Terrestrial Magnetism, Ionosphere and Radiowave Propagation RAN of.
Investigation of Thermodynamic and Radiation Effects at Loading Intermetallic LaNi 5 by hydrogen Yu.N.Bazhutov 2, E.O.Belousova 3, A.Yu.Kazyonov 1, V.P.Koretsky,
RELEC project (Relativistic ELECtrons). Unified platform “Karat” for small spacecraft 2 MICROSATELLITE KARAT FOR PLANETARY MISSIONS, ASTROPHYSICAL AND.
Sayfa 1 EP228 Particle Physics Department of Engineering Physics University of Gaziantep Dec 2014 Topic 5 Cosmic Connection Course web page
RELEC project (Relativistic ELECtrons). Satellites Low altitudes Geostationary Balloons Arctic Antarctic Ionosphere Atmosphere particles Space and balloon.
Analysis of Parameters of Bright Events in Variations of Secondary Particles of Cosmic Rays during Thunderstorms N.S. Khaerdinov & A. S. Lidvansky Institute.
Neutron bursts associated with lightning cloud-to-ground discharges V.I. Kozlov, V.A. Mullayarov, S.A. Starodubtsev, A.A. Toropov Yu.G. Shafer Institute.
S.V.Goncharov, V.V.Surkov, Pilipenko V.A.
MITKO G.G for ″Thunderstorm″ Collaboration ECRS-2012 Bursts of gamma-rays, electrons and low-energy neutrons during thunderstorms at the Tien-Shan.
G.K. Garipov 1, B.A. Khrenov 1, P.A. Klimov 1, V.S. Morozenko 1, M.I. Panasyuk 1, V.I. Tulupov 1, V.M. Shahparonov 1, S.A. Sharakin 1, S.I. Svertilov 1,
Ground level enhancement of the solar cosmic rays on January 20, A.V. Belov (a), E.A. Eroshenko (a), H. Mavromichalaki (b), C. Plainaki(b), V.G.
1 Atmospheric variations as observed by the BUST Barometric effect M.Berkova, V.Yanke, L.Dorman, V.Petkov, M.Kostyuk, R.Novoseltseva, Yu.Novoseltsev, P.
The short particle bursts during thunderstorms: EAS or lightning seeds? G. Hovsepyan, A. Chilingarian, A. Alikhanian National Laboratory, Armenia.
1 IGY The ALERT signal of ground level enhancements of solar cosmic rays: physics basis, the ways of realization and development Anashin V., Belov A.,
Introduction A pulsar magnetosphere can be divided into two zones: The closed zone filled with a dense plasma co-rotating with the neutron star (NS), and.
Spectra of the Thunderstorm Correlated Electron and Gamma-Ray Measured at Aragats Bagrat Mailyan and Ashot Chilingarian.
On the Role of Electric Field Changes when Calculating Thunderstorm Currents Yu.V. Shlugaev, V.V. Klimenko, E.A. Mareev Institute of Applied Physics RAS,
SN 1987A as a Possible Source of Cosmic Rays with E 0 < eV by Yakutsk EAS Array Data A.V. Glushkov, L.T. Ksenofontov, M.I. Pravdin Yu.G. Shafer Institute.
Cosmic rays at sea level. There is in nearby interstellar space a flux of particles—mostly protons and atomic nuclei— travelling at almost the speed of.
Cosmic Rays Cosmic Rays at Sea-Level - Extensive Air Showers and the detection of cosmic rays.
Variations of Cosmic Rays during Thunderstorms N.S. Khaerdinov & A. S. Lidvansky Institute for Nuclear Research, Russian Academy of Sciences, Moscow, Russia.
On the origin of the huge natural electron accelerators operated in the thunderclouds Ashot Chilingarian Artem Alikhanyan National Laboratory (Yerevan.
Cosmic Rays2 The Origin of Cosmic Rays and Geomagnetic Effects.
Study of the Atmospheric Muon and Neutrinos for the IceCube Observatory Ryan Birdsall Paolo Desiati, Patrick Berghaus,
MET 125 Physical Meteorology
Nucleon Decay Search in the Detector on the Earth’s Surface. Background Estimation. J.Stepaniak Institute for Nuclear Studies Warsaw, Poland FLARE Workshop.
Study of high energy cosmic rays by different components of back scattered radiation generated in the lunar regolith N. N. Kalmykov 1, A. A. Konstantinov.
Geophysical Research Network operating in the Aragats Space Environmental Center A. Chilingaryan 1, K. Arakelyan 1, S. Chilingarian 2, A. Reymers 1 1 A.
The objective of the CRONUS-Earth Project is to simultaneously address the various uncertainties affecting the production and accumulation of in-situ cosmogenic.
Transient response of the ionosphere to X-ray solar flares Jaroslav Chum (1), Jaroslav Urbář (1), Jann-Yenq Liu (2) (1) Institute of Atmospheric Physics,
Light is a Particle Physics 12.
Some results of observation of ultraviolet and infrared emission from lightning discharges at Aragats Cosmic Station LEAD workshop Armenia, NOR AMBERD.
The objective of the CRONUS-Earth Project is to simultaneously address the various uncertainties affecting the production and accumulation of in-situ cosmogenic.
Layers of the Atmosphere 1.  The atmosphere is divided into layers according to major changes in its temperature.  Gravity holds the layers of the atmosphere.
Detecting shielded nuclear contraband using muon tomography Judson Locke, William Bittner, Leonard Grasso, Dr. Kondo Gnanvo; Adviser: Dr. Marcus Hohlmann.
Simulation of Terrestrial Gamma Ray and Neutron Flashes (Small variations of thundercloud dipole moment) L.P. Babich, Е.N. Donskoĭ, A.Y. Kudryavtsev, M.L.
Nor Amberd station Aragats station 5 km 12.8 km 26.5 km 12.8 km between Nor Amberd and Aragats 39.1 km between Yerevan and Aragats 26.5 km between Yerevan.
Thunderstorm Dynamics Group Atmospheric ions and new particle formation For RAC meeting, Presented by Deveandraa Siingh The New particle formation (NPF)
Neutron emission in TGE’s L.Vanyan*, A.Chilingaryan, N.Bostanjyan, T.Karapetyan Yerevan Physics Institute.
Happy 2016!. Inverse polarity electric field at Aragats!
A little E&M review Coulomb’s Law Gauss’s Law Ohm’s Law.
STUDY of RADIATION RELATED with ATMOSPHERIC PRECIPITATIONS
A.S. Lidvansky, M.N. Khaerdinov, N.S. Khaerdinov
Development of a GLE Alarm System Based Upon Neutron Monitors
Investigations of CME in muon flux detected in hodoscopic mode
R. Bucˇık , K. Kudela and S. N. Kuznetsov
N.S. Khaerdinov & A. S. Lidvansky
Yuki Takagi1*, Kazuo Shiokawa1, Yuichi Otsuka1, and Martin Connors2  
Bagrat Mailyan, Alikhanian National Laboratory (Former YerPhI)
National Research Nuclear University MEPhI
The Layered Atmosphere:
Altai State University, RUSSIA
Conditions for Production of Terrestrial Gamma Ray Flashes (TGF)
Presentation transcript:

Events 1. Figure 4 shows: Left panel – Negative values ​​ of the electric field and data of high energy neutrons (upper panel), thermal neutrons (lower panel) during the passage of thunderstorm cloud over the high altitude Tien Shan station. Right panel – Change of the electric field polarity from negative to positive, data of the neutron monitor (upper panel), thermal neutrons (lower panel). The zero line - average neutron intensity before thunderstorm, red line – values of the electric field, grey line – 1 min data of the neutron monitor, blue line - smoothed of neutron monitor data (T- 3min), green line - 1 min data of thermal neutrons. Figure 4. Values of recorded parameters during the passage of charged clouds above the station with single lightning discharges Neutron monitor data changes occurs in opposite phase with electric field. Negative values of the electric field increases the neutron monitor count rate. Positive values of the electric field decreases of the neutron monitor count rate. Nature of the change in the count rate of the neutron monitor, depending on the polarity of the electric field suggests the muon mechanism of impact, based on the catching of soft negative muons by lead nucleons with escaping neutrons. It is known that 7% of the standard neutron monitor count rate caused by negative muons. Variations of thermal neutrons, excluding bursts due to lightning discharges, are within the standard deviation under fair weather conditions. The main difference of the thermal neutrons detector from the neutron monitor consists of in the absence of the lead. These results are consistent with our conclusion about the muon mechanism of the neutron monitor sensitivity to impact of electric field of the thunderstorm atmosphere in these events. Events 2. In the active phase of a thunderstorm, accompanied by powerful lightning discharges, in the formed thundercloud the picture of distribution of charges is complex and multilayered. Results of the analysis of the count rate of neutron detectors in events 2 don't correspond to the conclusions drawn on the basis of the analysis of events 1. Values of quasistatic electric field and a high-frequency field (records the return stroke, the green line) during a thunderstorm with powerful positive discharges (the left panel) are given in figure 5. The powerful discharge, which gave the greatest bursts of neutrons, is submitted with high time resolution. Figure 5. Values of the electric field during thunderstorm with positiv lightning discharges (left panel), the intensity of high energy neutrons (18NM64) and thermal neutrons (DTN). Since an electrical field is usually applied in a cloud–earth gap with minimal conductance, the positive values of the surface quasistatic electrical field mean the appearance of a positive charge in the cloud, slowing the negative particles (muons) moving downward. Figure 5 (the right panel) shows on the contrary bursts of neutrons in all detectors. The mechanism of change of the neutron flux for events 2 is different from the mechanism for events 1. Conclusions. Changes of neutron flux at different stages of thunderstorm activity are caused by different mechanisms. Changes of the neutron flux during thunderstorm activity without lightning discharges, but with large values of the electric field is described by the mechanism of the catching of soft negative muons by lead nucleons with escaping neutrons. Bursts of low-energy neutrons in the active phase of thunderstorms due to the mechanism that triggers the production of neutrons during the lightning discharge. However it still is discussed. The low-energy neutron flux value obtained in our work is a challenge for the photonuclear channel of neutron generation in thunderstorm: the estimated value of the needed high-energy γ-ray flux is about 3 orders of magnitude higher than that one observed [6]. Introduction The question of possible generation of neutrons in a strong atmospheric electric discharge (lightning) has quite long history and can be tracked before work [1] in which possibility of acceleration of particles in electric fields of a thundercloud up to the energies sufficient for initiation of nuclear reaction is discussed. During recent decades increase of neutron flux during of thunderstorm activity, both in orbital experiments, at sea level, and in the mountains have been measured. The high-altitude cosmic rays station at Tien-Shan (≥ 3340 m above sea level) is a unique site for investigations of the physics of lightning discharges. Installation ”Thunderstorm” is designed specially for the simultaneous recording of different kinds of radiation: accelerated charged particles (electrons), gamma- and X-ray radiation, thermal and fast neutrons, atmospheric electric fields and the radio-emission in the frequency range of 0.1 − 30 MHz, also as well as in VHF range about 250 MHz [2-7]. The presence of a wide-spread extensive air shower trigger set-up at the Tien-Shan station permits to study the role of energetic cosmic ray particles in lightning development. The aim of this paper is the study of the impact of electric fields on results of the monitoring of high-energy and thermal neutrons at different stages of thunderstorm activity. 1. Experimental complex. Experimental installations used in this work are part of "Thunderstorm" complex: the standard neutron monitor (the intensity of the neutron component of cosmic rays is recorded in six energy ranges), detectors of thermal neutrons (internal and external), detector of the quasistatic electric field, detector of the high frequency component of electric field. The detector of the atmospheric electric field according to the principle of operation is an electrostatic fluxmeter («field mill»), designed to measure the vertical component, Ez. The detector was contained in a waterproof case by working plates down in order to reduce the effect of precipitation on its operation. The detector allows to measure electrical fields in the range of ± 50kV/m, sampling frequency of 20 Hz under “fair weather" conditions and of 20·10 3 Hz under “thunderstorm weather" conditions. The high-frequency component of the electric field is recorded for the registration of the return stroke in the thunderstorm atmosphere. 2. Results of the monitoring at different stages of thunderstorm activity. It is known that measured variations of electric field in a surface layer of the atmosphere are caused mainly by weather conditions. Variations of the electric field under fair weather conditions aren't comparable with variations in the thunderstorm atmosphere. Conditions of “fair weather” are defined according to the following criteria: the absence of thunderstorms, precipitation, and fog; visibility of more than 4 km; and wind velocity of no more than 6 m/s. Typical diurnal values ​​ of the electric field under “fair weather" conditions at the high altitude station for summer are presented in fig. 1 (left panel). Standard deviation of minute values ​​ of the cosmic rays neutron component does not exceed 0.5% under “fair weather” conditions. It is presented in all figures for data of the neutron monitor by red horizontal lines. During a thunderstorm, the standard deviation is always greater than that under “fair weather”, Fig. 1 (right panel). Figure 1. Diurnal variations of electric field and data of the neutron monitor under “fair weather “ conditions (left panel), during sunderstorm activity (right panel).. Figure 2. Recordes of the neutron monitor count rate and the electric field during the passage of the thunderstorm cloud systems (without lightning discharges) consisting of multiple cells. RESPONS OF THUNDERSTORM ACTIVITY IN DATA OF NEUTRON MONITORING AT TIEN-SHAN STATION Valentina Antonova, Sergey Kryukov and Vadim Lutsenko Institute of Ionosphere of the National Center for Space Research and Technology, Almaty, Kazakhstan Study of similar thunderstorm events at Tien Shan has shown that a change in the count rate of the standard neutron monitor occurs at values ​​ of electric field ≥ 10÷ 15 kV/ m, Fig 2. The intensity of the neutron component of cosmic rays is recorded in six energy ranges (200 MeV ÷ 30 GeV). It has been established experimentally that the sensitivity of the detected particles to a changes in the electric field, Ez, increases with decreasing their energy. The response to the impact of the electric fields is absent in channels for neutron multiplicity ≥6, that corresponds to the energy of particles ≥ 10 GeV, Fig. 3. References [1] C.T.R.Wilson.//Proceedings of Cambridge Phylosophycal S0city, 22: , 1924 [2] A. V. Gurevich, A. N. Karashtin, et al. //Physics Letters A, 325: , [3] A. P. Chubenko, et al. //Physics Letters A, 373(39): , [4] A. V. Gurevich, et al. // Physics Letters A, 373(39): , [5] V. P. Antonova, et al. //Radiophysics and Quantum Electronics, 52(9): , [6] A. V. Gurevich, V. P. Antonova, A. P. Chubenko, A. N. Karashtin, et al. //Physical Review Letters, 108: , [7] A. V. Gurevich, V. P. Antonova, A. P. Chubenko, A. N. Karashtin et al. //Physical Review Letters, 111:165001, We divided the results of monitoring high-energy neutrons (the neutron intensity, measured by a standard monitor 18NM64) and thermal neutrons during the passage of thunderstorm clouds above the station depending on the stage of thunderstorm activity: Events 1 - The intensity of neutrons of different energies during the passage of thunderstorm clouds above the station without lightning discharges. In these events, change in the intensity of the particles is determined only by the electric field due to the charge distribution in the thundercloud and the earth's surface, Figure 4. Events 2 - The intensity of neutrons of various energies during the passage of thunderstorm clouds over the station in the active stage of thunderstorm, accompanied by powerful lightning discharges. The generation of neutrons is possible in these events. Figure 3. Variations of the neutron intensity in six energy ranges for the 2nd event of Fig. 4(the vertical dotted line is the instant at which the electric field polarity changes from negative to positive)