Further information: Performance of HIV Enzyme-Immunoassays on Dried Blood Spots for Quality Control of HIV Testing Dennis Olara 1,

Slides:



Advertisements
Similar presentations
Chagas Tests: Development and Standardization
Advertisements

Identifying HIV-2 Infections Using Differential Serological Assays HIV-1 (gp41)/HIV-2(gp36) (Select HIV or MultiSpot) by Testing HIV EIA Reactive Specimens.
Development of an oral fluid assay capable of differentiating recent from established HIV infection Niel Constantine 1, Ligia Peralta 1, Anne Sill 2, Kristen.
IDENTIFICATION OF FACTORS IMPACTING THE DETERMINATION OF HIV INCIDENCE IN NON-RESEARCH-BASED, CLINICAL POPULATIONS Sill, A.M. 1 ; Constantine, N.T. 2 ;
Unit 6 Diagnosis & Follow-up of HIV Infection
HIV-1/HIV-2 PLUS O To detect HIV Antibody Groups M & O Genetic Systems™ HIV-1/HIV-2 PLUS O EIA   HIV Subtypes and Variants   Description of HIV-1/HIV-2.
Comparative Performance of Dual 3rd Generation Immunoassays as a Potential Laboratory-Based HIV-1/2 Testing Strategy. B. Bennett, S. Fordan, O. David,
Evaluation of the IMMY CrAg Lateral Flow Assay for Detection of Cryptococcal Antigen Susan Clarke and Robert Gibb Pathology Queensland – Central, Royal.
Resolution of Discordant Confirmatory Results on POC Reactive Rapid Tests: Florida’s Pilot Project HIV Diagnostics: New Developments and Challenges Feb.
Supplemental Testing of Donors for HIV and HCV September 18, 2003 BPAC Meeting Robin Biswas, M.D. Indira Hewlett, Ph.D. FDA/CBER/OBRR/DETTD.
Comparing the New EIAs with Old Standbys: Florida Bureau of Laboratories Verification Data HIV Diagnostics: New Developments and Challenges Feb. 28, 2005.
Can Sequentially Reactive EIA’s Replace HIV-1 Western Blot Testing? Robert A. Myers Ph.D.
Technical and Operational Considerations for Scaling Up
Use of dried blood spots (DBS) or dried serum/plasma spots (DSS/DPS) to detect recent HIV-1 seroconversion by the BED-CEIA Bharat Parekh, PhD Centers for.
6/03/031 Hepatitis C –Update Laboratory Issues Hema Kapoor MD. SM Virology Section Manager Bureau of Laboratories Michigan Department of Community Health.
Newborn Screening Quality Assurance Program Newborn Screening Quality Assurance Program Comparison of Less Sensitive HIV Incidence Tests for the Serological.
12/6/07 v.3CDC 2007 HIV Diagnostic Conference1 Diagnosis of HIV-1 Infection in Phase I & II HIV Vaccine Trials RW Coombs 1, J Dragavon 1, B Metch 2, CJ.
CDC HIV Diagnostics Conference December 5-7, 2007 Sensitivity of OraQuick and Early Generation Enzyme Immunoassay (EIA) within a Pooled HIV Nucleic Acid.
Use of avidity reagent. Panbio Buffered Avidity Reagent Mild protein-denaturing solution that may be useful in differentiating recent infections from.
Epidemiology of HIV-2 infection in the U.S, Lata Kumar MS, MPH Richard Selik MD Division of HIV/AIDS Prevention National Center for HIV/AIDS,
Vironostika® HIV-1 Plus O Microelisa System
Is Nucleic Acid Testing for Organ Donors the ‘Right’ Choice? Reference: Humara A, Morrisb M, Blumbergc R, et al. Nucleic acid testing (NAT) of organ donors:
Laboratory Quality Control
Assigning individuals to ethnic groups based on 13 STR loci X. Fosella 1, F. Marroni 1, S. Manzoni 2, A. Verzeletti 2, F. De Ferrari 2, N. Cerri 2, S.
Internal Quality Control (QC) for Medical Laboratories: An introduction Dr. Otto Panagiotakis and Dr. Alexander Haliassos ESEAP – Greek Proficiency Testing.
Evaluation of Commercially Available HIV Assays to Address Alternative Screening/Diagnostic Algorithms S. Michele Owen, Ph.D. Laboratory Branch Division.
THE EFFECTIVENESS OF A RE- TESTING PROTOCOL TO ASSURE QUALITY DNA PCR TESTING FOR EARLY INFANT DIAGNOSIS (EID) IN MALAWI XVIII INTERNATIONAL AIDS CONFERENCE.
Department of Clinical Laboratory Sciences, College of Applied Medical Sciences, Al Jouf University.
HIV Testing CDC power point edited by M. Myers
APHL Survey HIV Diagnostic Testing Utilization Barbara G. Werner, PhD MA State Laboratory Institute February 28, 2005.
Tests for Recent Infection and CDC’s Plans for the Detuned IND Bernard M. Branson, M.D. Centers for Disease Control and Prevention.
HIV Rapid Testing Dr. Kevin Harvey National HIV/AIDS Programme Ministry of Health Jamaica.
Incorporation of the Aptima® HIV-1 RNA Assay into Serodiagnostic and Rapid Test Confirmation Testing Algorithms to Resolve Discordant Serological Results.
HIV Testing Quality Assurance and Quality Control
(Enzyme Linked Immunosorbent Assay)
Results from the LA rapid testing study: What can they tell us about proposed point of care strategies? Kevin Delaney, MPH Division of HIV/AIDS Prevention.
Pooled Source Plasma NAT for HIV-1 An Update from the Bayer HIV-1 IND Study Barbara Masecar Bayer Corporation Raleigh, NC Blood Products Advisory Committee.
BioLife Plasma Services Experience with HBV NAT Testing
PG-Seph. APCCB IDENTIFICATION OF MACRO- PROLACTIN WITH PROTEIN-G SEPHAROSE Jones GRD, Giannopoulos P. Departments of Chemical Pathology, St Vincent’s.
Performance of rapid HIV tests used singly and in combination: Moving toward a point of care diagnosis. Kevin Delaney, MPH HIV Diagnostics: New Developments.
Figure 1 A Case Series of Discordant Laboratory Results with Statewide Rapid HIV Testing in New Jersey Eugene G Martin, PhD 1, Gratian Salaru, MD 1, Sindy.
Limitations of HIV Antibody Testing in a Population with High Incidence of HIV Infection Joanne Stekler 1,2, Paul D. Swenson 1,2, Robert W. Coombs 1, Joan.
Performance Characteristics of the FARRZYME™ High Avidity Anti-dsDNA IgG Antibody ELISA Brenda B. Suh-Lailam 1, Tyson R. Chiaro 1, K. Wayne Davis 1, Andrew.
Development of a detuned oral assay for recent HIV infection F. Priddy 1, P. Phelan 1, P. Tambe 1,2, C. del Rio 1 1 Emory University School of Medicine,
ARMED FORCES RESEARCH INSTITUTE OF MEDICAL SCIENCES XVIII International AIDS Conference, July , Vienna Austria Recent Trends in estimated HIV-1.
PERFOMANCE CHARACTERISTICS AND COST BENEFIT OF THE SD BIOLINE HIV/SYPHILIS DUO TEST KIT IN ZIMBABWE Mtapuri-Zinyowera S, Gumbo P, Munemo E, Ncube G, Machiha.
Update on Assay Development George J. Dawson, Ph.D. Infectious Diseases: Core R & D Abbott Laboratories West Nile Virus.
Yi-Chen Yang, Yu-Hsuan Chen, Show-Lan Chiu, Hwei-Fang Cheng Drug Biology Division, Bureau of Food and Drug Analysis Department of Health, Taiwan, ROC National.
E001372A 1 ARC Experience with Indeterminate Blood Donors Susan L. Stramer, Ph.D. National Confirmatory Testing Laboratory American Red Cross.
Trends in HIV incidence in Ontario based on the detuned assay: Update to October 2000 Robert S. Remis, Carol Major, Carol Swantee, Margaret Fearon, Evelyn.
Evaluation of the Presage™ ST2 ELISA Jun Lu 1, David G. Grenache 1,2 1 ARUP Institute for Clinical and Experimental Pathology, Salt Lake City, UT 2 Department.
Trends in HIV incidence in Ontario based on the detuned assay: Update to December 2002 Robert S. Remis, Carol Major, Carol Swantee, Margaret Fearon, Robert.
Update Rapid HIV Test Approval Requirements and Standards BPAC September 15, 2000 Kimber Poffenberger, Ph.D.
Probe Validation Anne Wiktor September 21, Abnormalities identified by FISH.
Advanced Science and Technology Letters Vol.74 (ASEA 2014), pp Development of Optimization Algorithm for.
MTN-028 Laboratory Related CRFs. Pharmacokinetics Specimens (PKS-1) - Enrollment, Day 28 Pharmacokinetics Specimens (PKD-1) - Days 1, 2, 3, 7, 14, 21,
VALIDATION OF ICE- SYPHILIS ELISA METHOD IN NAKASERO BLOOD BANK, UGANDA Presented By: Wilson Wambi.
Dawit Assefa Ethiopia Health and Nutrition Research Institute Dawit Assefa Ethiopia Health and Nutrition Research Institute Evaluation of an in-house HIV.
Incorporation of NAT into supplemental testing of HCV and HIV seroreactive donors Michael P. Busch representing Blood Systems Research Institute Blood.
Lee Roberts and Charlotte Stead
One-Stage Quantitative
TUPEB018 Field evaluation of rapid HIV serologic tests for screening HIV-1/2 infection using serum samples from Rakai Cohort, Uganda. S.C. Kagulire, P.D.
California Clinical Laboratory Association
Redox QUANTITATIVE ANALYTICAL CHEMISTRY Electrochemistry
Combining rapid diagnostic tests and dried blood spot assays for point-of-care testing of human immunodeficiency virus, hepatitis B and hepatitis C infections.
Wilson Wambi 1, Ronald Ayikobua 2, Gilbert Sunday3
Toward a More Perfect World
Consider two conductors carrying charges of equal magnitude but of opposite sign, Such a combination of two conductors is called a capacitor. The capacitance.
Quality Assessment The goal of laboratory analysis is to provide the accurate, reliable and timeliness result Quality assurance The overall program that.
Challenges for Blood Donor Confirmatory Testing Algorithms
Presentation transcript:

Further information: Performance of HIV Enzyme-Immunoassays on Dried Blood Spots for Quality Control of HIV Testing Dennis Olara 1, Harriet Mutesi 1, Benon Biryahwaho 2, Robert Downing 1 1 CDC-Uganda, Uganda Virus Research Institute,Uganda, 2 HIV Reference & Quality Assurance Laboratory, Uganda Virus Research Institute, Entebbe, Uganda Background The preferred specimen for QC testing in resource-poor settings is the dried blood spot [DBS]. Previous experience with Genetic Systems [GS] rLAV and Vironostika [V UII] HIV-1 Uniform II plus O parallel testing on DBS has been disappointing; GS rLAV gave a high proportion of indeterminate results necessitating repeat testing by EIA and WB. Moreover, parallel testing algorithms are more expensive than sequential algorithms and cannot be sustained in most developing countries in the absence of donor support. A side-by-side evaluation of GS rLAV, V UII and Murex [M] HIV.1.2.O EIAs was therefore undertaken to document the performance of the individual EIAs on DBS and to identify the best algorithm for DBS QC testing in terms of performance and cost. Methods DBS from known HIV seropositive [68] and seronegative [103] persons were made, processed and stored according to established protocols. Elution of serum from DBS and subsequent testing was according to the manufacturer’s recommendations except that for GS rLAV, the volume of elution buffer was doubled. The Dilsim buffer from Biomerieux was used for elution for the V UII and Murex EIA protocols. Analysis was carried out on both raw optical density [OD] values and calculated standardized OD [SOD] values; mean OD values +2SD for HIV-negative samples were used as the cut-off OD value to calculate SOD values. The consensus HIV result for both sequential and parallel testing algorithms were determined retrospectively for all possible combinations and compared to the known serostatus. Results, grouped by integer of 0.25 [crude OD values] and 2.50 [SOD values] are presented in both tabular and graphic form. Results Overall performance of the assays: V UII had the highest mean OD value and range for HIV-positive specimens [Table 1] and GS rLAV the lowest which may reflect the ‘in-house’ protocol; V UII also performed better than the other assays on HIV-negative samples. Raw OD values: Table 2 shows the raw OD values for the three assays [grouped bu integer of 0.25] stratified against HIV serostatus. Negative specimens have OD values at the lower end of the scale and positive specimens at the higher end with a good separation between. V UII showed the best separation of positive and negative specimens in terms of raw OD values; all negative specimens had OD values 1.5 [max. OD reading was 3.5]. Results are presented graphically in Figs 1-3. SOD values: SOD values enable comparisons to be made between EIA plates by normalizing OD values against the mean OD value of negative specimens. Table 3 shows the SOD values for the three assays [grouped by integer of 2.5]. Murex had the best separation between positive and negative specimens in terms of SOD values; all negative specimens had SOD values <2.5 and positive specimens had SOD values ≥7.5. V UII had three positive specimens with SOD values <5.0; all were from the same worksheet where the mean OD value of negative specimens was 0.27 [SD=0.27] compared with a normal mean of <0.02 [SD<0.02]. Results are presented graphically in Figures 4, 5 and 6. Algorithms: Results by the six sequential and three parallel testing algorithms are shown in Table 4. All combinations of tests performed with 100% sensitivity compared with the known serostatus. Amongst parallel testing algorithms, V UII plus GS rLAV gave the best specificity [98.1%] with only two specimens unresolved. There appears to be no advantage in using a parallel over a sequential testing algorithm with these three EIAs. The best performing algorithms were sequential ones based on V UII plus GS rLAV or V UII plus Murex. Conclusions A sequential EIA testing algorithm using V UII as the screening assay and either GS rLAV or Murex HIV.1.2.O as the confirmatory assay performed with 100% sensitivity and specificity. Since there is a significant cost differential between GS rLAV and Murex HIV.1.2.O, the most cost-beneficial algorithm to use for DBS QC testing is a sequential testing algorithm based on Vironostika HIV Uniform II + O and Murex HIV.1.2.O. Figs. 1-3Figs. 4-6 Table 2 HIV Serostatus GS rLAV Murex V UII Crude OD value POS NEG POS NEG POS NEG Total Table 1 Mean DBS OD values ___________________________________________________________ HIV serostatus GS OD [SD] M OD [SD] V UII OD [SD] N Positive [0.37] [0.61] [0.56] 68 Range Negative [0.085] [0.11] [0.01]103 Range ___________________________________________________________ Table 3 HIV Serostatus GS rLAV Murex V UII SOD OD value POS NEG POS NEG POS NEG ≥ Total Table 4 Screening Confirmation# of SensitivitySpecificity of Indeterminates Sequential GS rLAV Murex2100%98.1% GS rLAV Vironostika2100%98.1% Murex GS rLAV3100%97.1% Murex Vironostika3100%97.1% Vironostika GS rLAV0100%100% Vironostika Murex0100%100% Parallel GS rLAV+Murex5100%95.1% GS rLAV+Vironostika2100%98.1% Murex+Vironostika3100%97.1%