1 HVACR318 – Refrigeration II International Mechanical Code Relating to Refrigeration.

Slides:



Advertisements
Similar presentations
Heating, Ventilation, and Air-Conditioning (HVAC) Systems
Advertisements

Regulations (Standards - 29 CFR) Flammable and Combustible liquids
Fired And Unfired Pressure Vessels
International Mechanical Codes Scald Protection. – Where a combination potable water-heating and space-heating system requires water for space.
Chapter 8: Duct Design and Sealing To be used with the Guide to Building Energy Efficient Homes in Kentucky.
HEATING AIR © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
Student Book © 2004 Propane Education & Research CouncilPage Placing Appliances into Initial Operation Knowing the proper techniques and.
NFPA 96 and Building Code Requirements for Commercial Kitchen Hood Systems Presentation for the Sevier County Fire Code and Building Code Officials Presented.
Basic Refrigeration Cycle
1 THE LACLEDE GROUP Natural Gas Distribution Overview and Safety MISSOURI ONE CALL SYSTEM OPERATING COMMITTEE MEETING DECEMBER 19, 2013.
Mechanical Plan Review. Review Plan Package Use Group/Occupancy Correct Code Reference/Conformance Revisions Mechanical Plans/Spec Books Structural Plans.
3.4.6 Student Book © 2004 Propane Education & Research CouncilPage Maintaining Bulk Plant Compressors Knowledge of the processes involved in maintaining.
N.F.P.A. 13R Justin Bohlmann FIR-204.
Fires and Explosions.
Condensation Piping and Installation Drain Pans
Gas Transmission Pipelines
Fire safety is an important business. You need to take proper precaution in order to prevent a fire. Yes, fire may be inevitable but if prepared, you can.
Safe Handling of Flammable and Combustible Liquids
HVACR416 - Design Pressure Measurement Part 2. Pressure Measurement Several pressure measurements exist. They all measure the same things, the force of.
Refrigeration and Heat Pump Systems Refrigeration systems: To cool a refrigerated space or to maintain the temperature of a space below that of the surroundings.
VENTING AND COMBUSTION AIR
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
STEAM HEATING.
1 HVACR316 - Piping Related Codes Trade Math 1 Related Codes Trade Math 1.
CNG STATION & GARAGE MODIFICATION CODES & STANDARDS Graham Barker Business Development Manager.
Air Conditioning EPA Type II.
Unit 8: Portable Fire Extinguishers & Smoke Control Management Systems
AIR QUANTITY REQUIRED TO TRANSFER HEAT IN A FORCED AIR SYSTEM In all four mechanical systems considered, the transfer of heat, either by taking it out.
NFPA 54 National Fuel Gas Code Boiler Manufacturer ANSI Standards Local Codes Vent Manufacturer.
HVACR311 – Electrical for Refrigeration International Mechanical Code Relating to Refrigeration.
NFPA 31 Standard for the installation of Oil- Burning Equipment
CXS490 Carbon Dioxide Systems
Air Conditioning International Mechanical Code
David Garvin Product Manager EarthDirEX Geothermal Copyright © 2015 Nortek Inc. All rights reserved.
HVACR116 – Trade Skills Longest length method.
HVACR416 - Design Heat Loss / Heat Gain Part 1. Why? The primary function of Air Conditioning is to maintain conditions that are… o Conductive to human.
1 HVACR316 - Piping Related Codes Trade Math I Related Codes Trade Math I.
Unit 4: General Safety Practices
Refrigeration System Equipment Room Design
Changes to 2009 IFGC ( International Fuel Gas Code) Adopted by Reference by section Michigan Mechanical Code.
1 Mechanical for Oil Heat Mechanical codes. 2 Every state has codes. They may be the same in some states, but different in other states. Always have a.
Backflow Prevention for Fire Sprinkler Systems State of Illinois Plumbing Code.
1-1-Why Maintenance HVAC ? Increases equipment life & reliability Reduces size & scale & number of repairs Lowers maintenance costs through better.
HVACR416 - Design Pressure Measurement Part 1. Why Measure? Need to Make Sure: All combustion appliances vent properly All HVAC systems are installed.
1 HVACR316 - Piping Copper Tubing and Fittings. 2 2 Safety Refrigerant cylinders should be stored and transported in the upright position to keep the.
Chapter 2.1 Introduction to Culinary Arts
Plumbing Radiant Heating & Cooling Turf Conditioning Permafrost Ice and Snow Melt Ecoflex ® SupportSustainabilityEngineered PolymerCommercial SystemsIntroductions.
Presented by John Lewandowski and Mike Larabel Inspection, Testing, and Maintenance of Kitchen Hood Systems Michigan Fire Inspectors Society Winter Educational.
Day 1 Part 4 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Hot Work Permit Osan AB Fire Emergency Services.
© 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. Bad case of Installation RAC-B-A07.
29 CFR Subpart G Related Terminal Operations and Equipment.
Safe Handling of Flammable and Combustible Liquids.
Maria’s Restaurant Chapter 1 Section 4
Electrical Gas Plumbing Heating & Cooling
Fire Prevention Safety Department
Firefighting equipment
Leaky Appliance Trigger Rate
Two Minute Drill – Residential 3
Gas Transmission Pipelines
Presentation transcript:

1 HVACR318 – Refrigeration II International Mechanical Code Relating to Refrigeration

2 International Mechanical Code IMC is broken down into chapters and sections. The chapters and sections are in numerical order. It is important for you to be able to quickly identify chapters and sections when you are looking for something. IMC is broken down into chapters and sections. The chapters and sections are in numerical order. It is important for you to be able to quickly identify chapters and sections when you are looking for something.

3 Chapter 11 of IMC 2003 Governs the installation, design, construction and repair of refrigeration systems that use the vapor/compression refrigeration cycle. Governs piping, pressure vessels, pressure relief devices. Permanently installed devices are considered part of the system they are attached to. Governs the installation, design, construction and repair of refrigeration systems that use the vapor/compression refrigeration cycle. Governs piping, pressure vessels, pressure relief devices. Permanently installed devices are considered part of the system they are attached to.

Factory Built Equipment Factory built equipment that meets UL 207, 412, 471, or 1995 requirements, and that are self contained, are considered to meet code if installed and serviced in accordance with manufactures directions.

Protection All components of a refrigeration system that could be damaged must be protected in an approved manner.

Water Connections Water connections to a refrigeration system must be made in accordance with this code, and the International Plumbing Code.

Fuel Gas Connections Fuel gas connections for refrigeration systems must be made in accordance with the International Fuel Gas Code, as well as the International Mechanical Code.

Maintenance Mechanical refrigeration systems must be maintained in proper operating conditions and free from excessive oil, dirt, and waste; excessive corrosion; and other debris and leaks.

9 Section 1102 Section 1102 of the IMC describes the system requirements. − says refrigerants cannot be mixed. − addresses refrigerant purity. − addresses recovery − addresses reclaiming refrigerants. Section 1102 of the IMC describes the system requirements. − says refrigerants cannot be mixed. − addresses refrigerant purity. − addresses recovery − addresses reclaiming refrigerants.

10 Section 1103 Section 1103 talks about refrigerant system classification. −Starts with and occupancy classifications. Section 1103 talks about refrigerant system classification. −Starts with and occupancy classifications.

11 Section Occupancy Institutional – disabled, debilitated, or confined occupants that can not readily leave. Public assembly – large numbers of people who can not quickly leave. Residential – permanent provisions for sleeping, eating, cooking, and sanitation. Institutional – disabled, debilitated, or confined occupants that can not readily leave. Public assembly – large numbers of people who can not quickly leave. Residential – permanent provisions for sleeping, eating, cooking, and sanitation.

12 Occupancy Commercial – Transact business, receive and ship goods, receive personal service and food. Large mercantile – over 100 persons congregate above and below street levels to purchase merchandise. Commercial – Transact business, receive and ship goods, receive personal service and food. Large mercantile – over 100 persons congregate above and below street levels to purchase merchandise.

13 Occupancy Industrial – Not open to the public. Access to authorized persons are controlled. Used to manufacture or store goods such as chemicals, food, ice, meat, or petroleum. Mixed Occupancy – occurs when two or more classifications come together. Industrial – Not open to the public. Access to authorized persons are controlled. Used to manufacture or store goods such as chemicals, food, ice, meat, or petroleum. Mixed Occupancy – occurs when two or more classifications come together.

14 Section System Classification Systems are classified based on the probability of refrigerant leaks. −Low probability systems −High probability systems See table for classifications and refrigerants. Systems are classified based on the probability of refrigerant leaks. −Low probability systems −High probability systems See table for classifications and refrigerants.

15 Section 1104 Addresses maximum allowable refrigerant quantities. See table for guides. Addresses requirements for mechanical rooms. Addresses maximum allowable refrigerant quantities. See table for guides. Addresses requirements for mechanical rooms.

16 Section Gives definitions for volume calculations. Noncommunicating spaces are neighboring rooms or spaces that do not have any permanent openings connecting them and do not share an HVAC system. Gives definitions for volume calculations. Noncommunicating spaces are neighboring rooms or spaces that do not have any permanent openings connecting them and do not share an HVAC system.

17 Section Communicating spaces do share a permanent opening and share an HVAC system. Air can easily move from one location to another. Plenums – When the area above a ceiling is used as a supply or a return plenum these areas are included in the volume calculations. Communicating spaces do share a permanent opening and share an HVAC system. Air can easily move from one location to another. Plenums – When the area above a ceiling is used as a supply or a return plenum these areas are included in the volume calculations.

18 Section 1105 Section 1105 talks about machinery rooms and the requirements for leak detection, ventilation and shared use. Refrigerant detectors must be installed per International Fire Code. Open flames from fuel burning appliances are not allowed unless combustion air is ducted from outside. Section 1105 talks about machinery rooms and the requirements for leak detection, ventilation and shared use. Refrigerant detectors must be installed per International Fire Code. Open flames from fuel burning appliances are not allowed unless combustion air is ducted from outside.

19 Section Mechanical ventilation must be provided unless the mechanical room has adequate free openings. Mechanical ventilation must not discharge air closer than 20 feet from property lines and building openings. Makeup air must be provided to replace exhaust air. Mechanical ventilation must be provided unless the mechanical room has adequate free openings. Mechanical ventilation must not discharge air closer than 20 feet from property lines and building openings. Makeup air must be provided to replace exhaust air.

20 Section Under normal conditions the mechanical ventilation system must exhaust the larger of: −.5 cfm per square foot of mechanical room area. −A volume required to limit room temperature rise to 18°F., taking into account the ambient heating effect of all machinery in the room. Under normal conditions the mechanical ventilation system must exhaust the larger of: −.5 cfm per square foot of mechanical room area. −A volume required to limit room temperature rise to 18°F., taking into account the ambient heating effect of all machinery in the room.

21 Section Under emergency conditions (refrigerant leak or fire), the ventilation system must exhaust the air according to the following formula: Q = 0.07 x √G −Where Q = CFMs and G is refrigerant in pounds of the largest system in the mechanical room. Under emergency conditions (refrigerant leak or fire), the ventilation system must exhaust the air according to the following formula: Q = 0.07 x √G −Where Q = CFMs and G is refrigerant in pounds of the largest system in the mechanical room.

22 Section Termination of relief devices inside the mechanical room must be: −above grade. −outside the structure. −no less than 15 feet from other grade. levels −not less than 20 feet from any window, ventilation opening or exit. Termination of relief devices inside the mechanical room must be: −above grade. −outside the structure. −no less than 15 feet from other grade. levels −not less than 20 feet from any window, ventilation opening or exit.

23 Section 1106 Covers mechanical room special requirements.

24 Section Piping This section covers refrigerant piping. All piping must be installed in accordance with this section. The primary purpose of this section is to prevent leaks and damage to pipes. This section covers refrigerant piping. All piping must be installed in accordance with this section. The primary purpose of this section is to prevent leaks and damage to pipes.

25 Section Piping Materials: –Steel –Copper and Brass –Copper tubing –Copper tubing joints – must be brazed, not soldered. –Aluminum tubing Piping Materials: –Steel –Copper and Brass –Copper tubing –Copper tubing joints – must be brazed, not soldered. –Aluminum tubing

26 Section If joints and tubing are put into air ducts (DON’T DO THIS!!!) they must be able to withstand leaks at 150% higher than rest of system or any pressure relief setting.

27 Section Liquid receivers must be installed on all systems with 100 pounds or more of refrigerant.

28 Section 1108 Section 1108 talks about pressure testing refrigeration systems. The primary purpose of this section is to prevent leaks. Tests should be completed on both low and high pressure sides of system. Must be done with an inert gas such as nitrogen. Does not change pressure with temperature. Section 1108 talks about pressure testing refrigeration systems. The primary purpose of this section is to prevent leaks. Tests should be completed on both low and high pressure sides of system. Must be done with an inert gas such as nitrogen. Does not change pressure with temperature.

29 Section 1109 Talks about periodic testing requirements. Testing must be performed on the following upon request from a code official: −Treatment and flaring systems −Devices needed to operate the equipment −Fans and associated emergency ventilation systems −Detection and alarm systems Talks about periodic testing requirements. Testing must be performed on the following upon request from a code official: −Treatment and flaring systems −Devices needed to operate the equipment −Fans and associated emergency ventilation systems −Detection and alarm systems

30 Notes on Code International Mechanical Code is used in Connecticut. The BOCA code is used in MA. Each town or municipality has the right to add requirements to the code. Remember EPA requirements as well. International Mechanical Code is used in Connecticut. The BOCA code is used in MA. Each town or municipality has the right to add requirements to the code. Remember EPA requirements as well.

31 Notes on Code The CT licensing exam is open book and you will be given a list of code books to bring. Make sure you have the correct version. Current CT code is Update your code books every time a new version comes out. The CT licensing exam is open book and you will be given a list of code books to bring. Make sure you have the correct version. Current CT code is Update your code books every time a new version comes out.