Upgrade of the CMS hadron outer calorimeter with SiPM’s

Slides:



Advertisements
Similar presentations
Sci-Fi tracker for IT replacement 1 Lausanne 9. December 2010.
Advertisements

H1 SILICON DETECTORS PRESENT STATUS By Wolfgang Lange, DESY Zeuthen.
ATLAS SCT Endcap Detector Modules Lutz Feld University of Freiburg for the ATLAS SCT Collaboration Vertex m.
The CMS Detector Paoti Chang National Taiwan University
HCAL RBX PRR Overview Jim Freeman RBX PRR March 1-2, 2001.
An SiPM Based Readout for the sPHENIX Calorimeters Eric J. Mannel IEEE NSS/MIC October 30, 2013.
CMS Outer Hadron Calorimeter (HO) Project Naba K Mondal Tata Institute, Mumbai, India.
First CMS Results with LHC BeamToyoko Orimoto, Caltech 1 First CMS Results with LHC Beam Toyoko Orimoto California Institute of Technology On behalf of.
28 June 2002Santa Cruz LC Retreat M. Breidenbach1 SD – Silicon Detector EM Calorimetry.
ATLAS detector upgrades ATLAS off to a good start – the detector is performing very well. This talk is about the changes needed in ATLAS during the next.
A High-speed Adaptively-biased Current- to-current Front-end for SSPM Arrays Bob Zheng, Jean-Pierre Walder, Henrik von der Lippe, William Moses, Martin.
Performance of the DZero Layer 0 Detector Marvin Johnson For the DZero Silicon Group.
We observe two classes of anomalous signals in HCAL 2) Cherenkov light produced by interactions in the window of the Forward Calorimeter PMTs ¼ photoelectrons.
The sPHENIX Barrel Upgrade: Jet Physics and Beyond John Haggerty Brookhaven National Laboratory on behalf of the PHENIX collaboration Quark Matter 2012.
The SLHC and the Challenges of the CMS Upgrade William Ferguson First year seminar March 2 nd
SVX4 chip 4 SVX4 chips hybrid 4 chips hybridSilicon sensors Front side Back side Hybrid data with calibration charge injection for some channels IEEE Nuclear.
Photon detection Visible or near-visible wavelengths
1. 2 Outline Contract Status  Q.A. plan  construction plan Preparations for construction  populating the construction space Microscope electronics.
Reports from DESY Satoru Uozumi (Staying at DESY during Nov 11 – 25) Nov-21 GLDCAL Japan-Korea meeting.
Evaluation of Silicon Photomultiplier Arrays for the GlueX Barrel Calorimeter Carl Zorn Radiation Detector & Medical Imaging Group Jefferson Laboratory,
1 Performance of the LHCb VELO Outline LHCb Detector and its performance in Run I LHCb Detector and its performance in Run I LHCb VELO LHCb VELO VELO performance.
Detector development and physics studies in high energy physics experiments Shashikant Dugad Department of High Energy Physics Review, 3-9 Jan 2008.
PSD upgrade: Ar-present and Xe-future 1.- Status of the PSD upgrade 2.- PSD performance after upgrade 3.- Problems during the Ar-run 4.- Future scenarios.
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK) for KEKDTP photon sensor group.
Calibration UV LED system for CALICE scintillator based Tile Hadron Calorimeter Ivo Polák on behalf of the CALICE Collaboration Institute of Physics of.
CMS ECAL End Cap Meeting CERN 19 June to 23 June 2000 A.B.Lodge - RAL 1 ECAL End Cap High Voltage Cards and 2000 Electrical/Thermal Model. Progress on.
R&D on W-SciFi Calorimeters for EIC at Brookhaven E.Kistenev, S.Stoll, A.Sukhanov, C.Woody PHENIX Group E.Aschenauer and S.Fazio Spin and EIC Group Physics.
Scintillation hodoscope with SiPM readout for the CLAS detector S. Stepanyan (JLAB) IEEE conference, Dresden, October 21, 2008.
The Scintillator ECAL Beam Test at FNAL Adil Khan International Linear Collider Workshop 2010 LCWS10 & ILC10, Beijing, China CALICE Scintillator ECAL group.
Light Calibration System (LCS) Temperature & Voltage Dependence Option 2: Optical system Option 2: LED driver Calibration of the Hadronic Calorimeter Prototype.
The CMS Electromagnetic Calorimeter Roger Rusack The University of Minnesota On behalf of the CMS ECAL collaboration.
Peter, Wieczorek - EE Low Noise Charge Sensitive Preamplifier Development for the PANDA Calorimeter Design and Measurements of the APFEL - Chip.
S. Los CMS Upgrade Workshop, October 28, 2009, FNAL 1 SiPM Signal Shaping Sergey Los FNAL/CMS/HCAL.
CMS Calorimeter HB- HB+ HE- HE+ HF- HF+ HO-2 HO-1 HO0 HO+1 HO+2
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK)
The ZEUS Hadron-Electron-Separator Performance and Experience Peter Göttlicher (DESY) for the ZEUS-HES-group Contributions to HES Germany, Israel, Japan,
1 Development of Multi-Pixel Photon Counters (1) S.Gomi, T.Nakaya, M.Yokoyama, M.Taguchi, (Kyoto University) T.Nakadaira, K.Yoshimura, (KEK) Oct
Shashlyk FE-DAQ requirements Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA FE-DAQ workshop, Bodenmais April 2009.
08-June-2006 / Mayda M. VelascoCALOR Chicago1 Initial Calibration for the CMS Hadronic Calorimeter Barrel Mayda M. Velasco Northwestern University.
Apollo Go, NCU Taiwan BES III Luminosity Monitor Apollo Go National Central University, Taiwan September 16, 2002.
R&D status of the Scintillator- strip based ECAL for the ILD Oct LCWS14 Belgrade Satoru Uozumi (KNU) For the CALICE collaboration Scintillator strips.
The Compact Muon Solenoid. What does CMS do? The Compact Muon Solenoid is a general purpose particle detector installed at point 5 of the Large Hadron.
Solid State Detectors for Upgraded PHENIX Detector at RHIC.
The RICH Detectors of the LHCb Experiment Carmelo D’Ambrosio (CERN) on behalf of the LHCb RICH Collaboration LHCb RICH1 and RICH2 The photon detector:
SiPM Readback Noise Tagging & HCAL Calibration Dayton Thorpe July 8, 2010.
FSC Status and Plans Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA Russia workshop, ITEP 27 April 2010.
First CMS Results with LHC Beam
5-9 June 2006Erika Garutti - CALOR CALICE scintillator HCAL commissioning experience and test beam program Erika Garutti On behalf of the CALICE.
A Silicon Photomultiplier (SiPM) Based Readout for the sPHENIX Upgrade S. Boose, J. Haggerty, E. Mannel, A. Sukhanov For the PHENIX Collaboration Introduction:
H C A L 11 th International Conference on Advanced Technology and Particle Physics Villa Olmo (Como - Italy), October 5 - 9, 2009 THE PERFORMANCE OF THE.
Status of the PSD upgrade - Status of the PSD cooling and temperature stabilization system - MAPD gain monitoring system - PSD readout upgrade F.Guber,
Performance of Scintillator-Strip Electromagnetic Calorimeter for the ILC experiment Satoru Uozumi (Kobe University) for the CALICE collaboration Mar 12.
The Multi-Pixel Photon Counter for the GLD Calorimeter Readout Jul Satoru Uozumi University of Tsukuba, Japan for the GLD Calorimeter.
Upgrade of the MEG liquid xenon calorimeter with VUV-light sensitive large area SiPMs Kei Ieki for the MEG-II collaboration 1 II.
Status of the Front-end-Electronics based on NINO ASIC for the Time-of-Flight measurements in the MPD V. A. Babkin, M.G. Buryakov, V. M. Golovatyuk, S.
CMS ELECTROMAGNETIC CALORIMETER Jean-Pierre Ernenwein OVERVIEW 6th international conference on advanced technology and particle physics Villa Olmo, Como,
1 Projectile Spectator Detector: Status and Plans A.Ivashkin (INR, Moscow) PSD performance in Be run. Problems and drawbacks. Future steps.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK) for KEKDTP photon sensor group.
SiW Electromagnetic Calorimeter - The EUDET Module Calorimeter R&D for the within the CALICE collaboration SiW Electromagnetic Calorimeter - The EUDET.
Atlas SemiConductor Tracker final integration and commissioning Andrée Robichaud-Véronneau Université de Genève on behalf of the Atlas SCT collaboration.
The PSD at Pb-Pb run PSD drawbacks at Ar beam
Scintillation Detectors in High Energy Physics
FCAL R&D towards a prototype of very compact calorimeter
Calorimeter Mu2e Development electronics Front-end Review
Application of VATAGP7 ASICs in the Silicon detectors for the central tracker (forward part) S. Khabarov, A. Makankin, N. Zamiatin, ,
HCAL M&O-B Budget CMS Finance Board
The Compact Muon Solenoid Detector
5% The CMS all silicon tracker simulation
R&D of MPPC in kyoto M.taguchi.
Presentation transcript:

Upgrade of the CMS hadron outer calorimeter with SiPM’s Jake Anderson, on behalf of the CMS Hcal-HO collaboration Fermilab

Motivation The photo-sensors of the CMS outer hadronic calorimeter (HO) have had problems since their initial cosmic running with the full magnetic field. Because of these problems CMS has embarked on an effort to develop a “drop-in” replacement for the HPD sensors with SiPM sensors. This will bring the HO up to and exceed design sensitivity. This represents the first large scale application of SiPM sensors to accelerator based high energy physics. 10 June 2011 J. Anderson - TIPP 2011

The CMS detector Muon chambers Drift tubes/RPC in barrel Cathode strip/RPC in endcaps covers |η| < 2.4 Inner tracker Silicon pixels Silicon strips 3.8T Solenoid Hadronic Calorimeter Brass/scintillator/wls fiber Iron/quartz fiber Electromagnetic Calorimeter 76k PbWO4 crystals 10 June 2011 J. Anderson - TIPP 2011

CMS calorimeters 10 June 2011 J. Anderson - TIPP 2011

The hadron outer calorimeter (HO) “Tail catcher” for the barrel calorimeter. correct missing ET and jets particularly in Ring 0. Could be used to identify muons as well. 10 June 2011 J. Anderson - TIPP 2011

HO front-end readout The fibers from a single projective tower of scintillator are routed using an optical decoder (ODU) and then illuminate a pixel of an HPD. The HPD signal is amplified and digitized using a charge-integrating ADC ASIC. Data is transmitted off the detector via optical fiber. 10 June 2011 J. Anderson - TIPP 2011

Proposed upgrade While the HPD works well in high magnetic field barrel, it is too sensitive for consistent, reliable operation in the less well determined fields of the return yoke. This lead to an effort to develop a “drop-in” replacement based on SiPM sensors. SiPM advantages insensitive to magnetic fields better signal to noise eliminate 8kV HV supplies and maintenance 10 June 2011 J. Anderson - TIPP 2011

A SiPM sensor A SiPM consists of an array of tiny APD pixels, operating in Geiger mode with common readout. The pixels “count” photons. The sensor saturates as more photons hit more pixels. A hit pixel takes some time to recover to full sensitivity. Additionally temperature sensitivity radiation hardness input/Npixels output/Npixels 10 June 2011 J. Anderson - TIPP 2011

“Drop-in” replacement Using Hamamatsu 3mm x 3mm, 50 μm pitch, MPPC, we can mimic the layout of the HPD. These are coupled to the existing optical decoders and read out using the same ADC. 3x3 mm SiPM sensors Peltier cooler Connectors to Control board Alignment holes Thermal breaks Back Front 10 June 2011 J. Anderson - TIPP 2011

Control board Provides individual bias voltage to each sensor. Measurement of leakage current. Signal attenuation and shaping Peltier temperature controls. ODU SiPM board Control Board Parameter Hamamatsu 3x3 mm Maximum DAC set BV 100 V BV resolution 25 mV BV current limit (per diode) 100 uA Maximum measurable leakage current 40 uA Leakage current resolution 10 nA Diode grounding resistor 4.99 kOhm Temperature resolution 0.018 C control board ADC cards 10 June 2011 J. Anderson - TIPP 2011

Putting it together The two board stack is assembled and inserted as a replacement for the HPD. A copper strap carries heat from the Peltier element to the water cooled sidewalls of the enclosure. Bias voltage, Peltier voltage and other settings are controlled via I2C. Delrin cookie (Matrix for the optical fiber bundles) PCB PCB copper SiPMs Peltier cooler RTD Aluminum holder Readout Module side wall Silicone foam compression pad Thermal pad over R-C components Copper cooling strap Cooling strap is compressed between the Cookie holder, and side wall Control Board Standoff 10 June 2011 J. Anderson - TIPP 2011

Installation Run Shutdown 2011 2012 2013 2014 1 2 3 4 5 6 7 8 9 10 11 12   CMS: FPIX fixes, PLT, tracker humidity controls, new beam pipe, HF PMT, HO SIPM LHC: Collimator upgrade, Fix Splices, possible Linac4 Extended to open endcaps Short, 2 weeks CMS made an initial installation during the spring of 2009, replacing ~10% of the HO HPD’s. This initial trial has been successful, and CMS is preparing to replace all of the HO HPD’s during the next long LHC shutdown, foreseen in 2013. 10 June 2011 J. Anderson - TIPP 2011

Controlling it all Bias voltage circuit Capacitive coupling and leakage current monitoring To ADC Set voltage from DAC 10 June 2011 J. Anderson - TIPP 2011

Temperature control Control voltage on Peltier element and read back temperature. Under-temperature limit at 16° C. Feed-back possible to maintain a set temperature. 10 June 2011 J. Anderson - TIPP 2011

Capacitive coupling Because the ADC was specified for the HPD with an order of magnitude less gain, signals from the SiPM are coupled to the ADC via a 22 pF capacitor, reducing the gain by a factor of 16. Also decouples the large SiPM capacitance from the low input impedance of the ADC. DC coupled AC coupled 10 June 2011 J. Anderson - TIPP 2011

Performance Using data from test beams and from our initial trial installation, we can verify operational performance. Muons in collision data and test beams to see the improved signal to noise. Pions in test beams to look at “jet” reconstruction. Also used to tune MC routines to simulate the detector performance. 10 June 2011 J. Anderson - TIPP 2011

Hadronic performance We can see the improvement in cleaning up the low tails of hadronic jets. This is particularly important for ring 0 where the barrel calorimeter is its thinnest. 10 June 2011 J. Anderson - TIPP 2011

Dynamic range Our arrangement allows us to illuminate roughly 2500 of the 3600 pixels per sensor. Ring 1 is ~12 p.e./MIP => full dynamic range of 200 MIPS. Ring 0 has ~20 p.e./MIP. This assumes no saturation of course. We have tested correcting saturation effects and believe we could do it to ~5000 p.e. 10 June 2011 J. Anderson - TIPP 2011

Summary CMS has developed a replacement photo transducer for its outer hadronic calorimeter based on SiPM sensor technology. We have been able to successfully develop a sensor package that can functionally replace the HPD sensors and exceed their performance. We have been able to show from test installations, beam and bench tests that the new sensors will exceed the requirements of the HO system. The full system is under construction and is scheduled to be installed during the LHC shutdown of 2013. 10 June 2011 J. Anderson - TIPP 2011