To go to next page, click on Page- Chlorine testing with HACH colorimeters 22 Instrument care Wipe cells dry with lint free tissue before inserting into.

Slides:



Advertisements
Similar presentations
1 Data entry Presentation template for adaptation and use in medicine prices and availability survey training workshop for survey personnel Review all.
Advertisements

Analyze-Immediately Parameters pH Analyze Immediately Within 15 minutes of collection: pH Residual Chlorine Temperature Chlorine Dioxide Dissolved Oxygen.
Analyze Immediately Residual Chlorine. Topics…. Background: Chlorine Chemistry Industrial Application NJAC Regulations Summary.
Benchmark Series Microsoft Excel 2013 Level 2
Bureau of Nutrition Programs and Services Module II Online Application.
Receiving Step by Step Summary of Receiving Steps 1.WebSMARTT: Print a “Receiver” (new required step – a separate tutorial is available) 2.Count the.
Quality Assurance and Quality Control Dale Walker City of Olean Senior Water Plant Operator.
Kinetics of the Decomposition of Crystal Violet Indicator.
Customizing Reports. Custom Reports A report is a formatted hardcopy of the contents of one or more tables from a database. Although you can format and.
Step by Step Process. Checklist and Form Instructions A checklist is provided on the website to help applicants track their progress in completing the.
Login Screen Step 1: Enter Your Individual Login Id and Password Step 2: Click On Submit Button.
HOW TO USE THE SYSTEM Specialty Crop Block Grant Program Online System.
Uploading a Turnitin Assignment Faculty of Humanities and Social Sciences.
AquaGlo Water Detector Kit For Detecting Water in Jet Fuel
XceedPro Meter BEDSIDE GLUCOSE The following slides include a review in preparation for completion of the Bedside glucose recert quiz and performance of.
Final Exam Review Jeopardy Waterworks Operations WQT 111 Waterworks Operations WQT 111.
DataLogger Operation - 1 DataLogger ® Operation Procedures.
Standard Operating Procedures l At l Call for help at Orlando Office Tallahassee.
Web Time Entry for Approvers How do I approve Employee Time sheets?
C-TPAT Security Link Portal Online Application. Online C-TPAT Application - Part 1. Part 1 of the Online C-TPAT Application process: Complete the Company.
GLUCOSE TESTING USING THE TRUEtrack GLUCOMETER
Experts in Chem-Feed and Water Treatment Chlorine Chemistry.
TIMS LOGIN AND APPLICATION INFORMATION Spring
EXCEL INTERMEDIATE 1. WORKSHEETS Worksheet Tabs –Rename by double clicking –Can be moved by click and drag –Change colour by right click and choose Tab.
Address Refer to Slide 2 for instructions on how to view the full-screen slideshow.Slide 2.
ONLINE FILING WORKSHOP Presented By: The Indiana Lobby Registration Commission 1.
Welcome to State of Michigan Time & Expense Processing Employee Expense Modification With Advance Tutorial Brought to you by the Office of Financial Management.
ERA Manager Training December 19, Propriety and Confidential. Do not distribute. 2 ERA Manager Overview In an effort to reduce the need for Providers,
Medications Training. The following presentation is designed to walk you through the process of administering medications to students. Please refer to.
Bloomfield School District TECH TUESDAY WORKSHOP Technology Services and Support Edline/EGP-Grading Online January 10, 2012 Joanne Decker.
Scout Pro Training Introducing the Scout Pro Portable Balance: 7 Models From 200g x 0.01g to 6000g x 1g 5 Application Modes Optional USB or RS232 Interface.
GRITS Manage Orders Training Overview: Inventory and Manage Orders Functions 05/08/2014.
WESS Application System PKI Login Registration Process.
TST BOCES SCOOLS (South Central Organization of (School) Library Systems) INTERLIBRARY LOAN PROCESS…..An Overview Created by Michele Barr, TST ILL Login.
Using Microsoft Word & Excel §Open a new document in MS Word §Click on Tools & then Mail Merge l a dialogue box, like the one on this page, will appear.
Welcome to State of Michigan Time & Expense Processing Employee Expense Modification (No Advance) Tutorial Brought to you by the Office of Financial Management.
Web Center Training ©2003 Optimum Technology, Inc.
1 Sponsor Claim Process  Click on the Sponsor Claims menu in order to process claims.  The submenu will display: Sponsor Claims will display the most.
ACCU-CHEK Inform II Operator Training
At the end of this lesson you will be able to:
Indicator 13 Secondary Transition. Main Menu SPP13 has a navigation toolbar located at the top of each screen. If you use the toolbar to navigate to another.
EZRA STATISTICS & GCFA CHURCH USER GUIDE. LOGGING IN The first time you log in to the program, you will be led through initial steps to set up your account.
To go to next page, click on Page- Chlorine meter- Diluting over range samples Learning Objectives At the end of this lesson you will be able to: Dilute.
 You need a new workbook. How do you create one? (Pick one answer.) a. In the Cells group, click Insert, and then click Insert Sheet.
Career Technical Education Data Profile Management System.
DS200 PROCEDURES SPEAKER TOUCH SCREEN DISPLAY
Learning Aim C.  In this section we will look at how text, tables, forms and frames can be used in web pages.
2016 TELPAS Online Testing. TELPAS Assessment Management System Accessed at
CHLAMYDIA / GONORRHEA Vaginal Specimen Collection and Form Training NC State Laboratory of Public Health 2015.
Rice Equipment 7/24/08. Create New Rice Equipment Test Select FGIS-925 Rice CheckTest from dropdown list A new blank record will open Only Standard Users.
WESS Application System PKI Login Registration Process
Filing the annual Form 990-N for all 4-H bank accounts.
Materials (detailed list) Quantity (be specific)
Employee Self Service Lite Version
Field Inventory Services-Sanofi Inventory and Audit Training
WESS Application System PKI Login Registration Process
Together Let’s Design an Online Quiz
Fantastic Graphics Inc. 2017
A few tricks to take you beyond the basics of Microsoft Office 2007
Claims Upload and Security
Materials (detailed list) Quantity (be specific)
WESS Application System PKI Login Registration Process
Sampling Sample point - tap sampling
WESS Application System PKI Login Registration Process
WESS Application System PKI Login Registration Process
25Easter.
True or False True or False
AquaGlo Water Detector Kit For Detecting Water in Jet Fuel
GLUCOSE TESTING USING THE TRUEtrack GLUCOMETER
Presentation transcript:

To go to next page, click on Page- Chlorine testing with HACH colorimeters 22 Instrument care Wipe cells dry with lint free tissue before inserting into instrument. Empty the cells and rinse with de-ionised water. Dry the packing foam if wet. Thoroughly clean and dry unit if wet. Always use the carrying case.

To go to next page, click on Page- Chlorine testing with HACH colorimeters 23 Instrument settings - HACH Pocket Colorimeter Two ranges Low (0.00 – 2.20 mg/L). High (0.0 – 4.5 mg/L) Total Only. Switching ranges Press Zero & Read simultaneously. After one second, release the Zero button – keep holding the Read button.

To go to next page, click on Page- Chlorine testing with HACH colorimeters 24 Calibration check Monthly Using a DPD Secondary Standard Kit (kept in Regional or District offices) Instrument MUST be in Low range when checking calibration Kit is good for 2 years Store kits in cool place

To go to next page, click on Page- Chlorine testing with HACH colorimeters 25 Chlorine calibration secondary standards

To go to next page, click on Page- Chlorine testing with HACH colorimeters 26 Chlorine calibration secondary standards These standards have a use-by date and must not be used after they expire.

To go to next page, click on Page- Chlorine testing with HACH colorimeters 27 Chlorine calibration check Calibration check must be carried out in the Low Range only. The calibration kit contains a Blank. Only use this Blank with the calibration check and NOT with water samples. The correct standard chlorine concentrations are printed under the lid of the standards kit lid.

To go to next page, click on Page- Chlorine testing with HACH colorimeters 28 You need to keep a record of the results for your chlorine colorimeter data sheet Below is an example of a calibration check data sheet Calibration of HACH Pocket Colorimeter – {enter ID Number of Instrument}

To go to next page, click on Page- Chlorine testing with HACH colorimeters 29 Accepted tolerance Chlorine values beyond the stated tolerance indicate the colorimeter is out of specification. As a guide, when chlorine values are more than : ± 0.03 mg/L for Std 1 ± 0.03 mg/L for Std 2 ± 0.04 mg/L for Std 3 The unit must be sent to Water Technologies Section for checking – Contact Mr Kevin Xanthis

To go to next page, click on Page- Chlorine testing with HACH colorimeters 30 Error messages (for the blue unit) E1 - Unstable Reading E2 - Low Light Error E3 - Low Battery Message E7 - Improper Calibration Flashing 0.00 – Under range Flashing 2.20 – Over range in LO range Flashing 5.0 – Over range in HI range

To go to next page, click on Page- Chlorine testing with HACH colorimeters 31 Reporting procedure Water Corporation specifies approved procedures for reporting test results. Use the correct forms supplied at your worksite. Submit them in a timely manner as described at your work site.

To go to next page, click on Page- Chlorine testing with HACH colorimeters Quiz- Question 1 of 6 Chlorine is added to water because it forms the main barrier in the disinfection process. a) True b) False Click here for answer.here 32

To go to next page, click on Page- Chlorine testing with HACH colorimeters Quiz 1- Answer Chlorine is added to water because it forms the main barrier in the disinfection process. a) True 32

To go to next page, click on Page- Chlorine testing with HACH colorimeters Quiz- Question 2 of 6 Calibration check can be carried out in both the Low range or High range settings. a) True b) False Click here for answer.here 33

To go to next page, click on Page- Chlorine testing with HACH colorimeters Quiz 2- Answer Calibration check can be carried out in both the Low range or High range settings. b) False Calibration check must be carried out only in the Low range. 33

To go to next page, click on Page- Chlorine testing with HACH colorimeters Quiz- Question 3 of 6 When using the original HACH Pocket Colorimeter (blue unit) what does an error message of E2 mean? a) Low light error b) Unstable reading c) Low battery message d) Improper calibration Click here for answer.here 34

To go to next page, click on Page- Chlorine testing with HACH colorimeters Quiz 3- Answer What does an error message of E2 mean? a) Low light error 34

To go to next page, click on Page- Chlorine testing with HACH colorimeters Quiz- Question 4 of 6 When sampling water, it is important to replace the sample cell cap immediately to prevent loss of chlorine. a) True b) False Click here for answer.here 35

To go to next page, click on Page- Chlorine testing with HACH colorimeters Quiz 4- Answer When sampling water, it is important to replace the cap immediately to prevent loss of chlorine. a) True 35

To go to next page, click on Page- Chlorine testing with HACH colorimeters Quiz- Question 5 of 6 The proportion of hypochlorous acid depends on. a)pH b)temperature c)the ratio of chlorine and ammonia d)all of the above Click here for answer.here 36

To go to next page, click on Page- Chlorine testing with HACH colorimeters Quiz 5- Answer The proportion of hypochlorous acid depends on. d) all of the above 36

To go to next page, click on Page- Chlorine testing with HACH colorimeters Quiz- Question 6 of 6 Which of the following statements is true? a) Free chlorine is hypochlorous acid (HOCl ) b) Total chlorine = HOCl + Combined chlorine c) Combined chlorine is the sum of all chloramines d) All of the above Click here for answer.here 37

To go to next page, click on Page- Chlorine testing with HACH colorimeters Quiz 6- Answer Which of the following statements are true? d) All of the above 37

To go to next page, click on Page- Chlorine testing with HACH colorimeters 38 Summary This section covered: The importance of chlorine testing Chlorine testing procedures To return to first page, click on