TDSPWR2 Power Measurement and Analysis Software Addressing Today’s Challenges
Power Supply Industry Trends Voltages DecreasingCurrents Increasing Source: ECN Supplement (Mar 2001)
Power Measurement Challenges Smaller, portable electronic products Demand for efficient, smaller, cost- effective power sources Power dissipation from smaller packaging Reduced noise tolerances of host devices Regulated levels of radiated power
Introducing TDSPWR2 Power Measurement & Analysis Software Transforms a digital oscilloscope into a sophisticated power analysis tool
TDSPWR2 Features HiPower Finder and B-H Analysis Power loss measurements Sophisticated report generation Safe operating area Automatic ripple measurement setup Pre-compliance testing to EN standard THD, True Power, Apparent Power, Power Factor & Crest Factor Modulation analysis Auto Deskew
TDSPWR2’s Ideal Partners TDS5000 & TDS7000 Oscilloscopes Digital Phosphor Technology Fast waveform capture rate Live color analog-like display Long record length Advanced math Up to 1GHz bandwidth and 5GS/s sample rate
Measurement Challenge Switching Loss Most switching loss occurs during transitions Minimize transition time to reduce switching loss Must be able to measure turn-on, turn-off and cycle power loss Most oscilloscope solutions don’t measure to this level of detail
TDSPWR2 Solution Switching Loss TDSPWR2 automatically computes the switching loss at Turn-on, Turn-off and for the entire cycle at the switching device Min, Max and average values computed for trend data on switching loss over time in a dynamic load situation HiPower Finder feature analyzes pinpoints areas of instantaneous power dissipation
Measurement Challenge Core Loss & B-H Analysis Magnetic components designed to enhance performance may cause power dissipation Important to know the operating limits of these components in order to determine safe operation of the power supply No current oscilloscope solution can provide this data
TDSPWR2 Solution Core Loss & B-H Analysis TDSPWR2 provides visualization of the inductor behavior Automatically measures core loss and the inductance value of the coil TDSPWR2 automatically displays B-H plot for further analysis
Measurement Challenge Test Report Generation Customers demand lengthy, custom- formatted test reports Manual report preparation is very tedious and time- consuming
TDSPWR2 Solution Test Report Generation TDSPWR2 enables automatic generation of customized test reports Automatically generate reports with a push of a button Create templates, with custom oscilloscope fields, settings and measurements Size selection Editable Easily exportable file format
Measurement Challenge Analysis of Safe Operating Areas Designers must analyze and monitor the safe operating limits in a real- world environment with fluctuating power demands Requires capture and analysis of long-duration events
TDSPWR2 Solution Analysis of Safe Operating Areas TDSPWR2 and a DPO provide the long record length and automatic measurements to make this task fast, easy Long record length of scope captures entire event Automatically measure and determine safe operating area Locate and analyze the linkage between safe operating area and the waveform in the time domain
Measurement Challenge Quick Test To EN Standard Designers need to test for Current Harmonic standard EN standard Requires to analyze the current Harmonic component up to 40th component Need to know the sample rate to capture all harmonic component Understand the EN test process
TDSPWR2 Solution Quick Test To EN Standard TDSPWR2 provides Pre- Compliance test capability to test for EN standard Simple operation Automatically determines the sample rate and record length to capture all current harmonic Supports Class A,Class B, Class C, Class D devices Same time measures THD, True Power, Power factor
Measurement Challenge Measuring ripple at output DC Voltage Designers must measure ripple in output DC voltage to determine the noise in the output voltage Requires capture and analyze the ripple caused by by line frequency and switching frequency
TDSPWR2 Solution Measuring ripple at output DC Voltage Provides ripple due to line frequency by single button
TDSPWR2 Solution Measuring ripple at output DC Voltage Provides ripple due to switching frequency by single button
TDSPWR2 Summary Analyzes Power loss at switching device Analyzes Core loss and B-H analysis at magnetic component Simplifies customized test report formats Quickly provides data on Safe Operating Area Pre Compliance test to EN standard Simplified ripple measurement