Industrial Hygiene Indoor Particles: Technology Copyright © 2008 by DBS.

Slides:



Advertisements
Similar presentations
1 Copyright © 2011, Elsevier Inc. All rights Reserved. Size Analysis and Identification of Particles Chapter 4 Roger W. Welker.
Advertisements

Sampling and Measurement for Volatile Organic Compounds
(IAQ). Introduction  A collective group of fine solid particles, aerosols, mist, smoke, dust, fibers and fumes are called Respirable particles  Particles.
Aerosol and climate Chul Eddy Chung ( 정 철 ) GIST, Korea.
1. Aerosol Instrumentation – In Situ Measurement of Particle Size and Number Example of size distribution (Number size distribution with three log- normal.
9. Mine Aerosol Measurements Health harzard in exposure to respirable mineral aerosol: 1. Pneumoconiosis โรคปอด 2. Asthma โรคหืด 3. Emphysema การพองลมของเนื้อเยื่อหรือถุงลม.
Field Methods of Monitoring Atmospheric Systems Chp. 3 – UV-Visible Differential Optical Absoprtion Spectroscopy Copyright © 2006 by DBS.
A Dictionary of Aerosol Remote Sensing Terms Richard Kleidman SSAI/NASA Goddard Lorraine Remer UMBC / JCET Short.
Fundamentals of Industrial Hygiene 6 th Edition Chapter 8: Particulate Matter Compiled by Allen Sullivan, Assistant Professor, Safety and Health Management.
Nanosafety assessment methodology Kaarle Hämeri Professor in Aerosol physics University of Helsinki Finnish Institute for Occupational Health.
Construction and Characterisation of a Particle Magnifier
IAQ Sampling Document a condition or state of the space –Adequate ventilation –Comfort Identify source of contamination –Leakage –Products.
VII. How might current analysis methods be enhanced or combined to obtain more information about the nature of OC, EC, and other carbon fractions in filter.
Ultrafine Particles and Climate Change Peter J. Adams HDGC Seminar November 5, 2003.
Satellite-based Global Estimate of Ground-level Fine Particulate Matter Concentrations Aaron van Donkelaar1, Randall Martin1,2, Lok Lamsal1, Chulkyu Lee1.
S.T. O’Sullivan D.J. Timoney University College Dublin Ireland On-road measurement of particulate emissions from diesel engined vehicles.
Nephelometer Introduction & Operation. What is a Nephelometer? The Nephelometer is an analytical instrument used to measure the light-scattering coefficient.
© 2011 Cemtek Environmental, Inc. Particulate Matter Monitoring Technologies and Detection Principles CEMTEK Environmental Inc S. Orange Ave. Santa.
Typically have a higher organic content than coarse particles Also contain soluble inorganics: NH 4 +, NO 3 -, SO 4 2- A bimodal peak is often observed.
Particles in the Atmosphere CONTENTS 1. Introduction 2. Physical properties 3. Particle formation and growth 4. Chemical composition 5. Radiative properties.
1 Motivation Particles are generally regarded as one of the most serious indoor air quality concerns Increasing concern about ultrafine particles Very.
Professor Kimberly Prather and research group University of California, San Diego.
CHEM-3245 Quantitative Analysis
Biological Aerosol’s Role as Ice Nuclei: Assessing Upper Tropospheric Bacteria Concentrations and Genus Benjamin Sheyko EAS /26/2012.
Air Pollution Chapter 4.
Working Together for Clean Air PM 2.5 Continuous Methods Lynnwood, Washington Site.
Air QualityJanuary AMS Short Course on Instrumentation 1 Air Quality Monitoring Melanie A. Wetzel Desert Research Institute University of Nevada,
Ambient Air Quality Monitoring Methods Lydia Scheer ITEP.
Common types of spectroscopy
Continuous Ambient Particulate Monitors A Review of Current Technologies by Michael Corvese, Product Manager Thermo Electron Corporation Air Quality Instruments.
Introduction to Thermo Electron Instruments Robert Kinsella Sky Patton Thermo Electron.
Field Methods of Monitoring Atmospheric Systems
Field Methods of Monitoring Atmospheric Systems Chemical Analysis of Particulate Matter Copyright © 2006 by DBS.
Carlos Gomes – Bin Hu – James Freihaut Slide 1 MindBend 2005 Resuspension of allergen-containing particles under mechanical and aerodynamic forces from.
Industrial Air Quality Monitoring. Sampling Protocols Grab vs. Integrated Personal vs. Area.
Monitoring Station Location and Siting Initially on a residential porch at Marina Towers, aligned with the Mirant Potomac River Generating Station (PRGS)
Temporal and Spatial Variations of PM2.5 Mass in Georgia Xiaolu Zhang EAS 6410 Spring 2007.
CCN measurements at an urban location Julia Burkart University of Vienna Istitute of Aerosol Physics, Biophysics and Environmental Physics.
Sampling and Measurement for Respirable Particulates.
Field Methods of Monitoring Atmospheric Systems Measuring the Size Distribution of Particulate Matter Copyright © 2006 by DBS.
Characterization of Aerosol Physical, Optical and Chemical Properties During the Big Bend Regional Aerosol and Visibility Observational Study (BRAVO) Jenny.
Proposal for a Research Infrastructure for Advanced Aerosol Observations and Capacity Building in China Alfred WIEDENSOHLER Leibniz Institute for Tropospheric.
ISSAOS 2008 l‘Aquila, September 2008 Aerosol Mass Spectrometry: General Principles and examples Hugh Coe School of Earth, Atmospheric and Environmental.
Continuous Particulate Monitoring Using Light Scatter Photometers.
Industrial Hygiene Indoor Particles: Fundamentals Copyright © 2008 by DBS.
Field Methods of Monitoring Atmospheric Systems Measurement of Air Pollution Copyright © 2009 by DBS.
Chapter 13 - Analytical Instrumentation 1 Chapter 14 Analytical Instrumentation.
Field Methods of Monitoring Atmospheric Systems Remote Sensing Copyright © 2006 by DBS.
Chemistry Topic: Atomic theory Subtopic : Mass Spectrometer.
1 Satellite Remote Sensing of Particulate Matter Air Quality ARSET Applied Remote SEnsing Training A project of NASA Applied Sciences Pawan Gupta Satellite.
Observations of aerosol concentration, properties and chemical composition Sandro Fuzzi Institute for Atmospheric Sciences and Climate National Research.
The Theory of Near Light Scatter
1 Objective Finish with PM measurements Discuss Friday’s filed measurements 1.
Janice Lam Snyder, SMAQMD December 11, 2015
Estimating PM 2.5 from MODIS and MISR AOD Aaron van Donkelaar and Randall Martin March 2009.
EMPIR Workshop – TP Environment Matthias Richter Birte Mull
Assessing Ambient Air Quality James Payne Morongo Band of Mission Indians.
Atmospheric Particles  Size range: to 50  m,  m particle contains ~1000 molecules  Concentration ranges: cm -3 =
Introduction Instruments designed and fabricated at the Desert Research Institute, Reno Emphasis on the Integrating Nephelometer for scattering measurements.
Hygrometry Part 2.
Ambient air sampling and monitoring Topic 5 Ms. Sherina Kamal.
Environment Canada, ETC, Ottawa
Chapter 1: The Nature of Analytical Chemistry
Particle Physics and Particle Counting for IH&S and IAQ
Session 4: Air Pollution Measurements
Aerosol chemistry studies at the SMEARIII station in Kumpula
Figure 2 Size categorization of airborne pollutants
Laura Lund University of Arizona Dr. William Conant
Droplet Nuclei Measurements in VOCALS Intro and Preliminary Results
Correcting TEOM Measurements using the KCL Volatile Correction Model
Presentation transcript:

Industrial Hygiene Indoor Particles: Technology Copyright © 2008 by DBS

Contents Introduction Mass Measurement Number Measurement Size Distribution Measurement Overview of technologies

Introduction Active and passive collection required for further physical + chemical + biological analysis In-situ techniques measure physical particle characteristic in real time (mass, number, size distribution, surface area) –Maybe direct (e.g. optical counting) or indirect (oscillating microbalance) –Developing technology: real-time chemical/biological characterization (Gard et al., 1997; Hairston et al., 1997)

Introduction Analysis of Airborne Particles McMurry, 2000; Willeke and Baron, 2001; Schwela et al., 2002

Mass Measurement Methods Gravimetric Methods Beta Attenuation Methods Vibration Microbalance Methods Light-Scattering Methods

Mass Measurement Gravimetric Methods Determines mg/m 3 Draws large volume of air over 24 hr period –Glass fiber or membrane filter –Weighed before and after –0.3 to ~100 μm particle size ‘Hi-Vols’ are not suitable for indoor use due to flow rate Reeve, 2002

Mass Measurement Beta Attenuator Methods (BAM) Beta particles from 14 C source are attenuated (lose signal strength) as they pass through particulate deposits on a filter tape Absorption of radiation is proportional to mass of PM –Contunuous real-time measurement (no weighing required!) Range: µg/m 3 Temperature: -30° to +45°C New version is heated to remove moisture effects Willeke and Hinds, 2001

Mass Measurement Vibrational Microbalance Methods Tapered Element Oscillating Microbalance (TEOM) Air is drawn through a filter at the end of a tapered oscillating glass tube Change in frequency is directly related to the mass of PM accumulated Range: µg/m 3 Temperature: -30° to +45°C Patashnik and Ruprecht, 1980

Mass Measurement Light-Scattering Methods Concentration of airborne particles In-situ, real-time measurements Categories: –Nephelometers (wider angle) –Photometers

Mass Measurement Light-Scattering Instruments: Photometers Most common direct-reading instrument Pros: –Real-time –Simpler to use, direct reading –Less expensive (long-term) Signal is proportional to total volume (not mass), particle density must be used to derive mass concentration Introduces uncertainty in measurements pp Morawska and Salthammer, 2004

Morawska and Salthammer, 2003

Number Concentration Measurement Optical particle counters (OPCs) based on principle of light scattering by particles –Coincidence error – when 2 particles cross the beam at once –Limited to particles > 0.1 μm Condensation particle counters (CPC) –Particles drawn through n- butanol vapor –Magnifies particles by growth via condensation –Detects down to 10 nm

Size Distribution Measurements Mass distribution with particle size Multistage Impactor (gravimetric or TEOM) - Larger particles stick to impaction plates Number distribution with particle size Light scattering or Electrical Low-Pressure Impactor (ELPI) - Measures electric current of charged particles at each impaction stage (Marjamaki et al., 2000)

Surface Area Measurements Epiphaniometer – determines Fuchs aurface area of particles using radioactivity (Gaggeler et al 1989)

Technology Overview

Question There are currently several investigations to compare the results of different PM analyzers. What reasons could contribute to this concern? Measurements are dependent on atmospheric conditions Absorbed water may be difficult to control during operations Meteorological conditions may affect flow rate Each technique responds differently to individual particle sizes Some components are volatile and may be lost due to heat (TEOM)

References *Baron, P.A. and Willeke, K. (eds.) (2001) Aerosol Measurement. Wiley-Interscience, New York. *Gard, E., J. E. Mayer, B. D. Morrical, T. Dienes, D. P. Fergenson and K. A. Prather (1997). "Real-time analysis of individual atmospheric aerosol particles: Design and performance of a portable ATOFMS." Analytical Chemistry, Vol. 69, No. 20, pp *Hairston, P. P., Ho, J., and Quant, F. R. (1997) Design of an Instrument for Real-Time Detection of Bioaerosols Using Simultaneous Measurement of Particle Aerodynamic Size and Intrinsic Fluorescence. Aerosol Science Technology. Vol. 28, pp. 471–482. Willeke and Hinds, 2001 *Lai, A.C.K. (2002) Particle Deposition Indoors: A Review (Summary Version). Indoor Air, Vol. 12, pp Marjamaki, M., Keskinen, J., Chen, D.R., and Pui, D.Y.H. (2000) Performance Evaluation of the Electrical Low-Pressure Impactor (ELPI). Journal of Aerosol Science, Vol. 31, No. 2, pp *McMurry, P.H. (2000) A Review of Atmospheric Aerosol Measurements. Atmospheric Environment, Vol. 24, pp *Schwela, D., Morawska, L., and Kotzias, D. (eds.) (2002) Guidelines for Concentration and Exposure- Response Measurements of Fine and Ultra-Fine particulate Matter for Use in Epidemiological Studies. World Health Organization. Patashnik, H. and Ruprecht, G. (1980) A New Real Time Aerosol Mass Monitoring Instrument: The TEOM. Paper presented at the Proceedings of Advances in particulate Sampling and Measurement. *Willeke, K. and Baron, P.A. (eds.) (2001) Aerosol Measurement: Principles, Techniques and Applications (2 nd ed.). Van Nostrand Reinhold, New York.

Books Jacobson, M.Z. (2002) Atmospheric Pollution. Cambridge University Press, Cambridge. Morawska, L. and Salthammer, T. (eds.) (2003) Indoor Environment: Airborne particles and Settled Dust. Wiley-VCH. Vincent, J.H. (2007) Aerosol Sampling: Science, Standards, Instrumentation and Applications. Wiley.