Introduction to Defrost

Slides:



Advertisements
Similar presentations
COE RAC SECTOR ITI UTTARSANDA
Advertisements

E1 – Electrical Fundamentals
HEAT PUMPS.
Refrigerators.
HEATING AIR © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
Setup/Installation/Operation of an Environmental Control Unit (ECU)
HVAC Commercial Ref.
Student CD for Commercial Refrigeration for A/C Technicians
Basic Refrigeration Cycle
Left Side Discharge Pressure Regulator
Refrigeration Flow Control
KE2 Evaporator Efficiency
Reading Electrical Schematics
COMMERCIAL REFRIGERATION UNIT 25
Product Introduction.
Trouble Shooting and Performance Testing
Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams
COMMERCIAL REFRIGERATION
2-Stage Heat Pump Defrost Options Defrost options: –30, 60, 90, 120 or Auto (Infinity/Evolution only) Defrost initiate temp: 32° F Defrost terminate temp:
1 HVACR316 - Piping Condensation Removal Refrigerant Traps Condensation Removal Refrigerant Traps.
1 Air Conditioning Pressure Switches. 2 High Pressure switch Used to protect the compressor When condensing temp gets too high Reads High Side Pressure.
Air-Source Heat Pumps I North Seattle Community College HVAC Program Instructor – Mark T. Weber, M.Ed. Airsource Heat Pump 1.
General Troubleshooting Tips.
Air Conditioning Circuit
HYDRONIC HEATING AQUASTATS
Air Conditioning Heating Refrigeration
Air Handler Terminology
Continue The information provided in this training module covers the schematic flow charts for all ovens and ranges that utilized a preheat board, Self.
Operation Sabbath Mode - SELECT PROGRAM - Lights, alarms and fans Normal Sabbath Overview.
Air Handler Terminology
BAKE BROIL - SELECT PROGRAM - CONV BAKE CONV BROIL SELF CLEAN On any diagram screen, double click any of the following components to bring you to a description.
Throw Pole Throw Pole nc no. Electric symbols Single pole single throw normally open Single pole single throw normally closed double pole single throw.
Section 5: Commercial Refrigeration
SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43.
Refrigeration What's Refrigerated? What makes up a system?
TITLE OF THE PROJECT:- AUTOMOBILE AIR CONDITIONING AIM OF THE PROJECT:- TO STUDY ABOUT AIR CONDITIONING SYSTEM OF AN AUTOMOBILE PRESENTED BY: INAMUL.
James McIntyre VRF Training Manager V5 Key Components.
E3 HVACR Controls and Devices
Fixed Orifice Tube Cycling Clutch System (FOTCC)
delivered with the compressor
E3 HVACR Controls and Devices
Fixed Orifice Tube Cycling Clutch System (FOTCC)
E1 – Electrical Fundamentals
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
© 2004 Refrigeration Training Services - Refrigeration Categories v1.1
E3 HVACR Controls and Devices
The Basic Direct Expansion Refrigeration Cycle
R3 Controls, Valves, Accessories & Heat Pumps
R3 Controls, Valves, Accessories & Heat Pumps
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
HYBRID AIR COOLING TECHNOLOGY
Air Treatment School Refrigerated Dryer Training
Presentation transcript:

Introduction to Defrost HVACR318 – Refrigeration Introduction to Defrost

Purpose of Defrost Systems Defrost systems are required in low temp and extremely low temperature applications to remove the ice that builds up on the evaporator coil. Ice is formed when warmer, humid air comes into contact with the below freezing conditions of an evaporator coil.

Type of Defrost Hot Gas Defrost Electric Defrost Uses a solenoid to re-route the discharge hot gas from the compressor to the evaporator bypassing the metering device and condenser. Electric Defrost Shuts down the compressor and the cooling system and energizes an electric heater.

Defrost Controls The controls required to run a defrost cycle are simple: Defrost Clock/Time Solenoid Valve

Defrost Timer Controls Initiates and terminates defrost cycle. Defrost frequency times can be changed by adding, moving, or installing more “set” pins. Try and keep the cycles “proportional” and keep in mind customers busy periods.

Defrost Time Controls The same controls are used for both hot gas and electric defrost systems. You do not need different timers as they are pretty much standard. Some contain a termination (clutch) solenoid to prematurely take the control out of defrost when needed.

Defrost Timer with Solenoid Timer Motor N 1 Source Source Copper band 3 2 Defrost Heater Or Hot gas Solenoid X 4 To Dtt To evaporator fan motor To refrigeration circuit (comp and cfm)

Defrost Timer with Solenoid Timer Motor X 3 Source Source N Copper band 1 2 Defrost Heater Or Hot gas Solenoid 4 To Dtt To evaporator fan motor To refrigeration circuit (comp and cfm)

Defrost Timer No Solenoid With X terminal Timer Motor N X Source Source 1 Defrost Heater Or Hot gas Solenoid 3 2 4 To evaporator fan motor To refrigeration circuit (comp and cfm)

Defrost Timer No Solenoid No X terminal Timer Motor N 1 Source Source 3 2 Defrost Heater Or Hot gas Solenoid 4 To evaporator fan motor To refrigeration circuit (comp and cfm)

Defrost Time Control Defrost Termination DTT Type DTT/High Limit Switch: Standard DTT which is a Defrost Thermostat, set at a high temperature to open when the ice has been melted or the coil reaches a specific temperature. The DTT de-energizes the heater.

Defrost Time Control Defrost Termination DTT Fan Delay Type Terminates and locks out the defrost cycle A Single Pole double Throw temperature actuated switch that runs the fan in refrigeration mode and will energize the release clutch solenoid (in the DTC) in the defrost mode.

Defrost Time Control When the control terminates the defrost cycle the EFM will be delayed until the compressor can make the evaporator cold enough to switch the control back to the EFM circuit. This control prevents a “Hot Pull Down” scenario on the compressor. Hot pull down means hot gas being returned to the inlet of the compressor.