Performance limits of a 55  m pixel CdTe detector G.Pellegrini, M. Lozano, R. Martinez, M. Ullan Centro Nacional de Microelectronica, Barcelona, 08193,

Slides:



Advertisements
Similar presentations
Section Two Requires e-h pair creation data from Section One and electric field model from Maxwell software package (Fig. 6 - left). The induced strip.
Advertisements

GRAPE(Gamma-Ray detector Array with Position and Energy sensitivity) Developed at CNS for in-beam  -ray spectroscopy with High Resolution M.
The Factors that Limit Time Resolution in Photodetectors, Workshop, University of Chicago, April 2011 What is known experimentally about timing determinants.
Imaging Properties of the Medipix2 System exploiting Single and Dual Energy Thresholds L. Tlustos 1, R. Ballabriga 1, M. Campbell 1, E. Heijne 1, k Kincade.
Giulio Pellegrini 4th SILC Collaboration Meeting, Dec. 2006, Barcelona, Spain Giulio Pellegrini 4th SILC Collaboration Meeting, Dec. 2006,
Standalone VeloPix Simulation Jianchun Wang 4/30/10.
RESMDD'02 pCT: Hartmut F.-W. Sadrozinski, SCIPP INITIAL STUDIES on PROTON COMPUTED TOMOGRAPHY USING SILICON STRIP DETECTORS L. Johnson, B. Keeney, G. Ross,
RF background, analysis of MTA data & implications for MICE Rikard Sandström, Geneva University MICE Collaboration Meeting – Analysis session, October.
Photon detection Visible or near-visible wavelengths
Why silicon detectors? Main characteristics of silicon detectors: Small band gap (E g = 1.12 V)  good resolution in the deposited energy  3.6 eV of deposited.
Measurement of gas gain fluctuations M. Chefdeville, LAPP, Annecy TPC Jamboree, Orsay, 12/05/2009.
ITAM CAS, IEAP CTU IWORID 2004Glasgow, th July IWORID 2004 OPTIMIZATION OF X ‑ RAY DYNAMIC DEFECTOSCOPY USING MEDIPIX-2 FOR HIGH FRAME RATE READ-OUT.
The 6th International Workshop on Radiation Imaging Detectors, July 2004, Glasgow Digital X-ray portable scanner based on monolithic semi-insulating.
Applications of a Pixellated Detection System to Digital Mammography
ALBA Synchrotron – 17 June 2010 Centro Nacional de MicroelectrónicaInstituto de Microelectrónica de Barcelona First Measurements on 3D Strips Detectors.
M. McConnell1, J. R. Macri, J. M. Ryan, K. Larson, L. -A. Hamel, G
FEE2006, Perugia Simultaneous Photon Counting and Charge Integrating Readout Electronics for X-ray Imaging Hans Krüger, University of Bonn, Germany University.
Imaging and spectroscopic performance studies of pixellated CdTe Timepix detector Dima Maneuski Vytautas Astromskas, Erik Fröjdh, Christer Fröjdh, Eva.
Other modes associated with SEM: EBIC
References Hans Kuzmany : Solid State Spectroscopy (Springer) Chap 5 S.M. Sze Physics of semiconductor devices (Wiley) Chap 13 PHOTODETECTORS.
Fully depleted MAPS: Pegasus and MIMOSA 33 Maciej Kachel, Wojciech Duliński PICSEL group, IPHC Strasbourg 1 For low energy X-ray applications.
Complete analysis of STJ detector performance via absorption of phonon pulses M. Stokes, K. Wigmore, A. Kozorezov, Physics Department, Lancaster University,
Energy calibration of the threshold of Medipix for ATLAS Céline Lebel Université de Montréal presenting for the Institut of Experimental.
1 Report on analysis of PoGO Beam Test at Spring-8 Tsunefumi Mizuno July 15, 2003 July 21, 2003 revised August 1, 2003 updated.
Development of CCDs for the SXI We have developed 2 different types of CCDs for the SXI in parallel.. *Advantage =>They are successfully employed for current.
Analysis of Edge and Surface TCTs for Irradiated 3D Silicon Strip Detectors Graeme Stewart a, R. Bates a, C. Corral b, M. Fantoba b, G. Kramberger c, G.
Charge collection in X-ray pixel detectors based on SI-GaAs doped with Cr G.I.Ayzenshtat a, M.V.Bimatov b, O.P.Tolbanov c, A.P.Vorobiev d a Science & Production.
SEM- Schematic Overview. Electron Detection Tungsten Filament Electron Source.
Pixellated CZT high-energy X-ray instrument
Geant4 User Workshop, Catania, Italy, 15th October, 2009
Fig. 1: Cross section of a circular DEPMOS- FET pixel cell. Charges collected in the “in- ternal gate’ modulate the transistor current. DEPMOSFET team,
JRA-1 ISRSI Consortium Meeting Perugia, INAF/IASF (BO,PA)
The development of the readout ASIC for the pair-monitor with SOI technology ~irradiation test~ Yutaro Sato Tohoku Univ. 29 th Mar  Introduction.
9 th “Trento” Workshop on Advanced Silicon Radiation Detectors Genova, February 26-28, 2014 Centro Nacional de MicroelectrónicaInstituto de Microelectrónica.
COMETH*: a CMOS pixel sensor for a highly miniaturized high-flux radiation monitor Yang ZHOU, Jérôme Baudot, Christine Hu-Guo, Yann Hu, Kimmo Jaaskelainen,
Goddard February 2003 R.Bellazzini - INFN Pisa A new X-Ray Polarimeter based on the photoelectric effect for Black Holes and Neutron Stars Astrophysics.
T. Lari – INFN Milan Status of ATLAS Pixel Test beam simulation Status of the validation studies with test-beam data of the Geant4 simulation and Pixel.
Timing in Thick Silicon Detectors Andrej Studen, University of Michigan, CIMA collaboration.
X-ray Dynamic Defectoscopy (XRDD) Direct observation of damage development in time dependent gradually stressed materials by means of X-ray transmission.
The Sixth International "Hiroshima" Symposium Giulio Pellegrini Technology of p-type microstrip detectors with radiation hard p-spray, p-stop and moderate.
Progress with GaAs Pixel Detectors K.M.Smith University of Glasgow Acknowledgements: RD8 & RD19 (CERN Detector R.&D. collaboration) XIMAGE (Aixtron, I.M.C.,
MPI Semiconductor Laboratory, The XEUS Instrument Working Group, PNSensor The X-ray Evolving-Universe Spectroscopy (XEUS) mission is under study by the.
ICT 1 SINTEF Edge-On Sensor with Active Edge Fabricated by 3D-Technology T. E. Hansen 1), N. Ahmed 1), A. Ferber 2) 1) SINTEF MiNaLab 2) SINTEF Optical.
6th Trento Workshop on Advanced Silicon Radiation Detectors1/16 J.P. BalbuenaInstituto de Microelectrónica de Barcelona IMB-CNM (CSIC) J.P. Balbuena, G.
10/25/2007Nick Sinev, ALCPG07, FNAL, October Simulation of charge collection in chronopixel device Nick Sinev, University of Oregon.
Update on works with SiPMs at Pisa Matteo Morrocchi.
DESCRIPTION OF PIXIRAD  The PIXIRAD Imaging Counter is an INFN-Pisa Spin-off  It works in photon counting  Pulse discrimination with two thresholds.
CdTe prototype detector testing Anja Schubert The University of Melbourne 9 May 2011 Updates.
Edgeless semiconductor sensors for large-area pixel detectors Marten Bosma Annual meeting Nikhef December 12, 2011, Amsterdam.
Equalization of Medipix2 imaging detector energy thresholds using measurement of polychromatic X-ray beam attenuation Josef Uher a,b, Jan Jakubek c a CSIRO.
Medipix3 chip, downscaled feature sizes, noise and timing resolution of the front-end Rafael Ballabriga 17 June 2010.
WP 7 (RDH) Detector for high intensity beam WP 6 (IRPT) New TERA chip development Leslie Karen Fanola Guarachi.
V.Aulchenko 1,2, L.Shekhtman 1,2, B.Tolochko 3,2, V.Zhulanov 1,2 Budker Institute of Nuclear Physics, , Novosibirsk, Russia Novosibirsk State University,
12 th Pisa Meeting, Isola d’Elba, 25 May 2012 Politecnico di Milano, Italy New Development of Silicon Drift Detectors for Gamma-ray.
CEA DSM Irfu IDeF-X HD Imaging Detector Front-end for X-ray with High Dynamic range Alicja Michalowska, CEA-IRFU 1 Journées VLSI June 2010.
Giulio Pellegrini 12th RD50 - Workshop on Radiation hard semiconductor devices for very high luminosity colliders, Ljubljana, Slovenia, 2-4 June 2008 Report.
6:th IWORID, Glasgow, Scotland, July 2004 Energy Dependence in Dental Imaging with Medipix 2 Börje Norlin & Christer Fröjdh Mid Sweden University.
DEVELOPMENT OF PIXELLATED SEMICONDUCTOR DETECTORS FOR NEUTRON DETECTION Prof. Christer Fröjdh Mid Sweden University.
Progress with GaAs Pixel Detectors
Silicon microstrip detector for imaging of fast processes at high intensity synchrotron radiation beam. Budker INP V.Aulchenko1,2, L.Shekhtman1,2, B.Tolochko3,2,
Performance of the Medipix and Timepix devices for the recognition of electron-gamma radiation fields C. Teyssier1,3, J. Bouchami1, F. Dallaire1, J. Idarraga1,
Report from CNM activities
The response function of semiconductor pixel detectors for highly ionizing particles Jan Jakubek, P. Soukup Institute of Experimental and Applied Physics,
X. Zhu1, 3, Z. Deng1, 3, A. Lan2, X. Sun2, Y. Liu1, 3, Y. Shao2
Mentor: Chris Kenney 12 August 2010
Beam Test Results for the CMS Forward Pixel Detector
Readout Electronics for Pixel Sensors
Readout Electronics for Pixel Sensors
Readout Electronics for Pixel Sensors
Presentation transcript:

Performance limits of a 55  m pixel CdTe detector G.Pellegrini, M. Lozano, R. Martinez, M. Ullan Centro Nacional de Microelectronica, Barcelona, 08193, Spain M. Chmeissani, M. Maiorino, G. Blanchot, J. Garcia C. Puigdengoles Institut de Física d'Altes Energies, UAB Campus, Bellaterra, Spain

2004 IEEE NSSGiulio Pellegrini Objectives of the research CdTe is one of the most widely studied material in the field of X-ray detection for energies above 10keV, due to its high absorption efficiency. CdTe detectors for imaging applications are usually fabricated in thick substrates and with pixel size smaller than 100μm. However, reducing the pixel size might lead to an increase in the charge shared among neighboring pixels due to the low mobility of the major carriers. The operation of a pixel detector is strongly influenced by the ratio of the pixel size to the thickness of the detector. We present charge sharing results from simulation and experimental data obtained with a specific purpose circuitry using Medipix-II with CdTe detectors.

2004 IEEE NSSGiulio Pellegrini X-ray absorption MammographyGeneral radiography

2004 IEEE NSSGiulio Pellegrini Charge sharing problem Charge sharing depends strongly on the position of the interaction of the incident X-ray. Since detectors are illuminated from the back contact, low energy x-rays will interact “far” from the pixel side. Charges generated in point 1 will be shared between different pixels. Charges generated in point 2 will be collected only in the central pixel. Mean free path* = 80  m for a 20 KeV X-ray in CdTe. 80% of the X-rays interact in the first 120  m *Average distance traveled before the interaction take place

2004 IEEE NSSGiulio Pellegrini CdTe detector 55  m 45  m 15  m Solder bumps CdTe pixel electrodes from ACRORAD

2004 IEEE NSSGiulio Pellegrini MEDIPIX-II chip Chip Specifications 55 µm pixel pitch (256×256) pixels (14.1×14.1 mm active area) 14 DAC settings Very good energy resolution (0.75keV) 1 Mbit data Serial & Parallel read-out bus (input bus is Serial only) Maximum estimated communication clock: 80 MHz Pixel Specifications 55×55 µm area Dynamic range: -1 ÷ bits (8 levels) threshold adjustment Schematic view of a detector pixel bump bonded to Medipix II chip Single photon counting mode

2004 IEEE NSSGiulio Pellegrini X-ray Imaging Image taken with Medipix2 chip with CdTe detector with low temperature bump bonding. Microfocus X-ray tube: 40 keV, 10 µA, 1 sec. Pixel size 55 µm Detector bias –100 V (electron collection)

2004 IEEE NSSGiulio Pellegrini Experimental setup 3×3 pixels matrix at the bottom of MPX2 chip (pixels 120,0 to 122,2) Spectrum 241 Am source Bias voltage :100V Chip analog outputs, got via DEar-MaMa read-out system, were digitised and read through GPIB bus Collected 500 events per bias value Events analyzed: values 3  above noise peak in the central pixel NOTE: the chip threshold level is NOT involved in this operation M. Chmeissani et al., [1] ”, Proc. of the 21st IEEE Instr. and Meas. Tech. Conf., Vol. 1, pp , Como, May 2004, Italy, ISBN

2004 IEEE NSSGiulio Pellegrini Charge sharing measurements The maximum charge collected in the central pixel is 60% at 400V.

2004 IEEE NSSGiulio Pellegrini Software package Electrical simulators: 3D simulator : ISE TCAD software Monte Carlo simulator: Geant4 Parameters : Carrier carrier scattering Recombination High field saturation No k-shell effect No traps added to the model.

2004 IEEE NSSGiulio Pellegrini Simulation results Charge collection efficiency is calculated for pixel 5 generating the charge in different points and at various depths.

2004 IEEE NSSGiulio Pellegrini Integrated charge Minuit fit Charge cloud profileCurrent density profile Bias =100 V x-ray generated in point 1 and at a depth of 100um from the back contact

2004 IEEE NSSGiulio Pellegrini Charge sharing comparison  Simulation results combining DESSIS and Geant4 Monte Carlo simulation.  Experimental result using an Americium source. The detector was biased at –100V. Average relative charge sharing for the 3x3 matrix simulated and measured experimentally.

2004 IEEE NSSGiulio Pellegrini Conclusions The data collected with the pixilated CdTe coupled to Medipix-II chip and the simulated results by DESSIS are in good agreement, thus one can use such a model to optimize the design of the pixilated CdTe detector for photon counting readout ASICS. A 1mm thick CdTe with small pixel pitch will have poor performance when coupled to Photon Counting (PC) ASIC. Either it does not trigger, if the threshold is relatively too high, or many pixels count the same photon if the threshold is very low.

2004 IEEE NSSGiulio Pellegrini CdTe spectroscopy