Product Presentation 2007 SKY AIR Launch of new Non-Inverter + Duct (R22) series.

Slides:



Advertisements
Similar presentations
Packaged Terminal Air Conditioners
Advertisements

Pre Sales Dept. HERCULES Solar 26 1 A Condensing floor-standing boilers with built-in solar circuit.
Fan Coil Unit Product Line-up. FCU Home Application Show.
SINGLE SPLIT INVERTER AIR-CONDITIONER
Setup/Installation/Operation of an Environmental Control Unit (ECU)
Trane Variable Water Flow System
DX-Central Air Conditioning Systems Smart,Flexible & Efficient Alternate for Malls and Commercial Buildings.
Page 1 MDS Installation. Page 2 Contents  Introduction  Outdoor Unit Installation  Indoor Unit Installation  Refrigerant Pipe Work  Gas Charge 
Installation. Indoor Unit Installation Typical Installation.
Wine Cellar Split System Basics. Definitions Split System – A cooling unit that “splits” the cooling coil and the condenser apart into two remote pieces.
Engineer Presentation
ASHRAE Presentation: VRF Overview Mitsubishi Electric Presenter: Phone number ©2011 Mitsubishi Electric& Electronics USA, Inc.
Cooling Only 38MFC/ 40MFC Heat Pump 38MFQ/ 40MFQ
Installation. Indoor Unit Installation Typical Installation.
Product Introduction.
1 AxiCool Unit Cooler / Evaporator - „Plug & Play“ Fan series GLV955 - GTB/MM-November 2013.
Daikin Australia Pty. Limited Ducted Split Systems 2011.
Air conditioning – Refreshes your life Applied Systems DAIKIN Fan Coil Units Comfort Applications >> FWB
‘YGFC’ FAN COIL UNITS NEW PRODUCTS
Wall / V 12 V 12 Introduction Arguments Technical details Installation.
MDS Smart Commander.
Heat Recovery Ventilator Be used with AC system, Create a healthy life.
Learning, our way Examples of bad installation. CONTENT Installation related examples Installation related examples Application related examples Application.
RESIDENTIAL AIR HANDLERS
Perfect solution for large building
Air conditioning – Refreshes your life Mini-Chiller Applied Systems Sales1 EWA(Y)Q-AAV3P Residential Mini-Chiller Heating EWAQ - AA3VP EWYQ - AAV3P Cooling.
Hydronic Global Satellite Program highlights
2007 New Product: Floor Standing Unit FVXS-F Sep-15 Public Reviewed by Strategic Marketing DENV Product Concept  Stylish and Compact design  New.
Air conditioning – Refreshes your life EWTP MBY Applied Systems Sales1 EWTP-MBYNN Air-cooled Heat Recovery.
Air Conditioning and Computer Centre Power Efficiency The Reality Christophe Martel Tony Cass.
2010.
Alan Hinton March, 2006 Slide 1 NEW! ‘YEFB’ HIGH PRESSURE BLOWER UNITS.
TECHNICAL TRAINING INVERTER-Y Introduction P RODUCT RANGE AND FEATURES.
Product Presentation 2007 SUPER INVERTER Sep-15 Public SKY AIR & PACKAGED SUPER INVERTER.
Lindab Solus - Simply the natural choice.... lindab | comfort Chilled beam revolution! + Save up to 45 % cooling energy!* + Installation and investment.
Hydraulic Kit (pump and tank) Pictures from prototype.
INSTALLATION & COMMISSIONING. 5WSS Installation Hanging the Unit Hanging the Unit Location Considerations Location Considerations Refrigerant Piping Refrigerant.
1 AxiCool Unit Cooler / Evaporator - „Plug & Play“ Fan series GLV955 - GTB/MM-November 2013.
/ 1 ERA A chiller to suit everyone. Air cooled water chillers Free-cooling chillers Air/water heat pumps.
Learning, our way Daikin Europe, Consulting sales section1 Understanding Client’s Needs and best Daikin solution.
Product Section Product Training. 50 Hz R410A R22 R407C Ceiling Convertible CE-E Series.
ERX-condensing units Strategic Marketing Dec-15 1.Concept 2.Product range 3.Combination table 4.Piping length 5.Control possibilities 6.Benefits.
To complete installation on electronic models run one wash cycle then click the DIP switch setting no.4 to the on position DIP switch settings.
New MSP Concealed Ceiling Unit (FBQ-D & FXSQ-A)
Introduction of New Wall Mounted AVS 18-24URCSBBA Commercial Air Conditioning Dept
Water is the Natural Choice Hydronic Comfort Systems Increase and Maintain Building Efficiency For the Life of Your Building
Esbe Rotary Motorized valves The ESBE Rotary Motorized valves (mixing valves and actuators) are used to control heating and cooling in buildings. We offer.
© 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. 5 August 2014.
DC Inverter Mini VRF Reference projects Reference Project Mini and Multi Improvements Product line -up.
2016 Chiller New Products Presentation.
Air condition installation
CHIGO HVAC Product Introduction.
UniTrane™ Terminals High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line
The New Digital Inverter Light Commercial Range
New 10kW CAC & NCAC High wall unit.
Compact line ‘EW*D~J-’ water-cooled chiller range
Specializing in Water-Cooled & Portable-Split Air Conditioner
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
COMFAIR HD WALL WATER FAN COIL UNIT
Ceiling Convertible (MCM-E Series)
DC Inverter Air-cooled Chiller Aqua Tempo Super II Series
Heat recovery feature Competitive approach
FCL FCL.
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
B. Munkhbayar BEEC/SCEA/MUST
Ceiling Convertible (ACM-E Series)
Ceiling Convertible (ACC75~100D Series)
Lineup (ATW) <2018> <2019> : New series Series Ref. Split
Ceiling Convertible (MCC075~100D Series)
Ductair II™ Low Profile Dx Ducted Split 3,5 5,3 7 8,8 10,6 14,1 17,6
Presentation transcript:

Product Presentation 2007 SKY AIR Launch of new Non-Inverter + Duct (R22) series

2 3-Nov-15 Public and Medium Static Pressure Duct FDYM NEW Low Static Pressure Duct FDYB NEW Sky Non-Inverter R22 Heat Pump RY-series +

3 3-Nov-15 Public Overview 1.Product Line-up 1.1 Product Range 1.2 Combination Table 1.3 Nomenclature 2.Benefits & Features 3.Product Characteristics 3.1 General Specifications 3.2 Operation Range 3.3 Refrigerant Circuit Diagrams 3.4 McQuay/Daikin Name Cross-over 4.Conclusion

4 3-Nov-15 Public 1.1 Product Range The Non-Inverter RY R22 outdoor series will be available: in combination with low/medium static pressure duct in heat pump and with R22 refrigerant in 1 and 3 phase power supply 1. Product Line-up

5 3-Nov-15 Public 1.2 Combination Table The indoor/outdoor combination will be available: in a wide capacity range (2.7kW to 16.4kW) in only Pair connection 1. Product Line-up

6 3-Nov-15 Public 1.3 Nomenclature: Outdoor 30CV1 Model Name & Type R : Outdoor Y : Heat Pump Capacity 30 : kW x 10 Series C : C series Power Supply V1 : V, 1ph, 50Hz Y1 : V, 3ph, 50Hz RY 1. Product Line-up

7 3-Nov-15 Public 1.3 Nomenclature: Indoor 30C Model Name F : Indoor D : Ceiling concealed Y : Heat Pump Capacity 30 : kW x 10 Series C : C series FDYB M - Model Type B : Low static duct M : Medium static duct - Note: Indoors are V, 1ph, 50Hz 1. Product Line-up

8 3-Nov-15 Public Double Protection Drainage System By introducing ‘Built In’ double drain pans solution, i.e. primary drain pan and secondary drain pan, water leaking will not be a problem anymore. A drain socket is supplied to connect both drain pans to the drainage pipe. The secondary drain pan will act as a drip pan to block any water that might be dripped down, thus offering an additional protection to the ceiling. So additional drain pan will not be necessary during installation which means more cost saving and easy installation at site. Secondary Drain Pan (with insulation) Primary Drain Pan (Polystyrene with High Impact Polystyrene cover) Space Saving with Easy & Flexible Installation The height of the unit is low, between 261mm (lowest) and 378mm (highest). Therefore it is offering greatest flexibility in selecting installation location above ceiling. Moreover with its special designed ducting, the installation job becomes easy and the conditioned air can be effectively distributed to every corner of the room to ensure a better air distribution and more pleasant environment for comfort living. 2. Benefits & Features

9 3-Nov-15 Public Easy Maintenance The simple design concept has a friendly maintenance and servicing in mind. By just removing the secondary drain pan and drain guide, you can access to all the internal parts from the bottom of the unit. No water will flow down when removing the secondary drain pan, making the servicing work very easy. Elegance and Low Noise Level The indoor unit is installed above the ceiling with only the supply and return air grille exposed to view. This ceiling concealed type of design has made it an elegant model without sacrificing the precious floor space, the air-conditioned space will appear as elegant and prestigious as centralized air-conditioned area, but with only a fraction of the cost. Further the casing is well insulated internally to reduce noise level. Versatility Different layouts can be ‘created’ so that multiple rooms can be cooled together at the same time by using just one indoor unit. Room Layout 1Room Layout 3 Room Layout 2 2. Benefits & Features

10 3-Nov-15 Public Electrical Control Capability All series are equipped with a wired Electronic SLM Remote Controller. The SLM features: an ON/OFF switch, temperature setting (16°C to 30°C), operation modes (auto/cool/dry/heat/fan), fan speed selection, timer (setting range between 1 to 10 hours), air swing and ‘Sleep Mode’. It is possible to make use of the AC-5300 infrared Remote Controller (in option) to communicate with the SLM Remote Controller. 2. Benefits & Features

11 3-Nov-15 Public 3.1 General Specifications Outdoor Unit RY30CV1 RY40CV1RY60CV1RY71CV1 Indoor Unit FDYB30CFDYB40CFDYB60CFDYB71C Power source V / 1ph / 50Hz Capacity in coolingkW in heatingkW Input power in coolingkW in heatingkW EER 3.17 (B)2.95 (C)3.03 (B)2.95 (C) COP 3.31 (C) 3.32 (C)3.24 (C) Running current in coolingA in heatingA Air flow Highm³/h Mediumm³/h Lowm³/h External static pressure Pa4.9 / 9.8 / / 20 / 295 / 15 / 25 Sound pressure level dB(A)26 / 30 / 3329 / 34 / 3734 / 36 / 3836 / 39 / 40 Dimensions Heightmm261 Widthmm Depthmm411 Weight kg Condensate drain size mm19.05 Air flow m³/h Sound pressure level dB(A) Dimensions Heightmm Widthmm Depthmm Weight kg Refrigerant charge kg Max piping length m12 15 Max height differencem5588 OUTDOOR Low Static Pressure Duct – 1 phase INDOOR GENERAL 3. Product Characteristics

12 3-Nov-15 Public 3.1 General Specifications Outdoor Unit RY80CV1 RY90CV1RY100CV1RY125CV1 Indoor Unit FDYB90CFDYB125C Power source V / 1ph / 50Hz Capacity in coolingkW in heatingkW Input power in coolingkW in heatingkW EER 2.75 (D)2.82 (C)3.06 (B)3.19 (B) COP 3.15 (D)2.85 (D)3.20 (D)3.46 (B) Running current in coolingA in heatingA Air flow High (super)m³/h1.494 (1.598)1.800 (2.023) Mediumm³/h Lowm³/h External static pressurePa20 / 29 / 39 / 49 Sound pressure leveldB(A)38 / 42 / 46 / 4941 / 45 / 49 / 51 Dimensions Heightmm378 Widthmm Depthmm541 Weight kg3942 Condensate drain sizemm19.05 Air flow m³/h Sound pressure leveldB(A)5458 Dimensions Heightmm Widthmm Depthmm Weight kg Refrigerant chargekg Max piping lengthm1545 Max height differencem825 OUTDOOR Low Static Pressure Duct – 1 phase INDOOR GENERAL 3. Product Characteristics

13 3-Nov-15 Public 3.1 General Specifications Outdoor Unit RY90CY1 RY125CY1RY140CY1RY160CY1 Indoor Unit FDYB90CFDYB125CFDYB140CFDYB160C Power source V / 3ph / 50Hz Capacity in coolingkW in heatingkW Input power in coolingkW in heatingkW EER 2.84 (C)3.22 (A)2.89 (C)2.79 (D) COP 2.87 (D)3.50 (B)3.47 (B)3.38 (C) Running current in coolingA in heatingA Air flow High (super)m³/h1.494 (1.598)1.800 (2.023)2.260 (2.567)2.754 (2.887) Mediumm³/h Lowm³/h External static pressurePa20 / 29 / 39 / / 39 / 59 / 7820 / 29 / 49 / 69 Sound pressure leveldB(A)38 / 42 / 46 / 4941 / 45 / 49 / 5147 / 50 / 52 / 5347 / 50 / 53 / 55 Dimensions Heightmm378 Widthmm Depthmm541 Weight kg Condensate drain sizemm19.05 Air flow m³/h Sound pressure leveldB(A)58 61 Dimensions Heightmm850 Widthmm1.030 Depthmm Weight kg Refrigerant chargekg Max piping lengthm45 35 Max height differencem25 15 OUTDOOR Low Static Pressure Duct – 3 phase INDOOR GENERAL 3. Product Characteristics

14 3-Nov-15 Public 3.1 General Specifications Outdoor Unit RY30CV1 RY40CV1RY60CV1RY71CV1 Indoor Unit FDYM30CFDYM40CFDYM60CFDYM71C Power source V / 1ph / 50Hz Capacity in coolingkW in heatingkW Input power in coolingkW in heatingkW EER 3.09 (B)2.84 (C)2.94 (C)2.63 (D) COP 3.52 (B)3.39 (C)3.14 (D)2.77 (E) Running current in coolingA in heatingA Air flow Highm³/h Mediumm³/h Lowm³/h External static pressure Pa29 / 39 / 4920 / 39 / 4942 / 65 / 6918 / 31 / 41 Sound pressure level dB(A)26 / 30 / 3329 / 34 / 3734 / 36 / 3836 / 39 / 40 Dimensions Heightmm261 Widthmm Depthmm411 Weight kg Condensate drain sizemm19.05 Air flow m³/h Sound pressure leveldB(A) Dimensions Heightmm Widthmm Depthmm Weight kg Refrigerant chargekg Max piping lengthm12 15 Max height differencem5588 OUTDOOR Medium Static Pressure Duct – 1 phase INDOOR GENERAL 3. Product Characteristics

15 3-Nov-15 Public 3.1 General Specifications Outdoor Unit RY80CV1 RYC90CV1 Indoor Unit FDYM80CFDYM90CFDYM80CFDYM90C Power source 220 – 240V, 1ph, 50Hz Capacity in coolingkW in heatingkW Input power in coolingkW in heatingkW EER 2.56 (E)2.73 (D)2.84 (C)2.79 (D) COP 3.11 (D) 2.87 (D)2.82 (D) Running current in coolingA in heatingA Air flow High (super)m³/h (1.444)1.410 (1.530)1.375 (1.444)1.410 (1.530) Mediumm³/h Lowm³/h External static pressure Pa59 / 68 / 78 / 9888 / 127 / 167 / / 68 / 78 / 9888 / 127 / 167 / 206 Sound pressure level dB(A)34 / 38 / 41 / 4438 / 42 / 46 / 4934 / 38 / 41 / 4438 / 42 / 46 / 49 Dimensions Heightmm Widthmm Depthmm Weight kg Condensate drain size mm19.05 Air flow m³/h Sound pressure level dB(A)5458 Dimensions Heightmm Widthmm Depthmm Weight kg6895 Refrigerant chargekg Max piping lengthm1545 Max height differencem825 OUTDOOR INDOOR GENERAL Medium Static Pressure Duct – 1 phase 3. Product Characteristics

16 3-Nov-15 Public 3.1 General Specifications Outdoor Unit RY100CV1 RY125CV1 Indoor Unit FDYM100CFDYM125CFDYM100CFDYM125C Power source 220 – 240V, 1ph, 50Hz Capacity in coolingkW in heatingkW Input power in coolingkW in heatingkW EER 3.11 (B)3.01 (B)2.96 (C)3.14 (B) COP 3.19 (D)3.14 (D)3.25 (C)3.62 (A) Running current in coolingA in heatingA Air flow High (super)m³/h (2.617)1.800 (1.868)2.500 (2.617)1.800 (1.868) Mediumm³/h Lowm³/h External static pressure Pa88 / 108 / 118 / / 127 / 176 / / 108 / 118 / / 127 / 176 / 206 Sound pressure level dB(A)45 / 48 / 51 / 5541 / 45 / 49 / 5145 / 48 / 51 / 5541 / 45 / 49 / 51 Dimensions Heightmm Widthmm Depthmm Weight kg Condensate drain size mm19.05 Air flow m³/h5.778 Sound pressure level dB(A)58 Dimensions Heightmm 850 Widthmm Depthmm 400 Weight kg95100 Refrigerant charge kg2.60 Max piping length m45 Max height differencem25 OUTDOOR INDOOR GENERAL Medium Static Pressure Duct – 1 phase 3. Product Characteristics

17 3-Nov-15 Public 3.1 General Specifications Outdoor Unit RY90CY1 RY125CY1 Indoor Unit FDYM80CFDYM90CFDYM100CFDYM125C Power source 380 – 415V, 3ph, 50Hz Capacity in coolingkW in heatingkW Input power in coolingkW in heatingkW EER 2.86 (C)2.81 (C)2.98 (C)3.17 (B) COP 2.89 (D)2.84 (D)3.28 (C)3.65 (A) Running current in coolingA in heatingA Air flow High (super)m³/h (1.444)1.410 (1.530) (2.617)1.800 (1.868) Mediumm³/h Lowm³/h External static pressure Pa59 / 68 / 78 / 9888 / 127 / 167 / / 108 / 118 / / 127 / 176 / 206 Sound pressure level dB(A)34 / 38 / 41 / 4438 / 42 / 46 / 4945 / 48 / 51 / 5541 / 45 / 49 / 51 Dimensions Heightmm Widthmm Depthmm Weight kg Condensate drain size mm19.05 Air flow m³/h5.778 Sound pressure level dB(A)58 Dimensions Heightmm 850 Widthmm Depthmm 400 Weight kg95100 Refrigerant charge kg Max piping length m45 Max height difference m25 OUTDOOR INDOOR GENERAL Medium Static Pressure Duct – 3 phase 3. Product Characteristics

18 3-Nov-15 Public 3.1 General Specifications Outdoor Unit RYL140AY1 RYL160AY1 Indoor Unit FDYML140AFDYML160A Power source 380 – 415V, 3ph, 50Hz Capacity in coolingkW in heatingkW Input power in coolingkW in heatingkW EER 2.90 (C)2.73 (D) COP 3.49 (B)3.30 (C) Running current in coolingA in heatingA Air flow High (super)m³/h (2.700)2.600 (2.805) Mediumm³/h Lowm³/h External static pressure Pa108 / 137 / 157 / / 137 / 157 / 176 Sound pressure level dB(A)47 / 50 / 52 / 5347 / 50 / 53 / 55 Dimensions Heightmm 378 Widthmm Depthmm 541 Weight kg5462 Condensate drain size mm19.05 Air flow m³/h Sound pressure level dB(A)5861 Dimensions Heightmm 850 Widthmm Depthmm Weight kg Refrigerant charge kg Max piping length m4535 Max height differencem2515 OUTDOOR INDOOR GENERAL Medium Static Pressure Duct – 3 phase 3. Product Characteristics

19 3-Nov-15 Public 3.2 Operation Range In cooling: +19°C / +46°C In heating: -9°C / +18°C Heating Cooling 3. Product Characteristics

20 3-Nov-15 Public FDYB/M30C RY30CV1 3.3 Refrigerant Circuit Diagrams 3. Product Characteristics

21 3-Nov-15 Public FDYB/M40C RY40CV1 3.3 Refrigerant Circuit Diagrams 3. Product Characteristics

22 3-Nov-15 Public FDYB/M60C RY60CV1 3.3 Refrigerant Circuit Diagrams 3. Product Characteristics

23 3-Nov-15 Public FDYB/M71C RY71CV1 3.3 Refrigerant Circuit Diagrams 3. Product Characteristics

24 3-Nov-15 Public FDYM80C FDYB/M90C RY80CV1 3.3 Refrigerant Circuit Diagrams 3. Product Characteristics

25 3-Nov-15 Public 3.3 Refrigerant Circuit Diagrams FDYM80C FDYB/M90C RY90CV/Y1 FDYM100C FDYB/M125C RY100CV1 RY125CV/Y1 FDYB/M140C RY140CY1 3. Product Characteristics

26 3-Nov-15 Public 3.3 Refrigerant Circuit Diagrams FDYB/M160C RY160CY1 3. Product Characteristics

27 3-Nov-15 Public 3.4 McQuay/Daikin Name Cross-over 3. Product Characteristics

28 3-Nov-15 Public An indoor unit that is elegant, space saving (lowest height is 261mm), with 4 fan speeds and a well insulated casing to reduce noise level. Moreover it has a ‘Double Protection Drainage System’ to offer an additional protection to the ceiling and easy maintenance. With the introduction of the new Non-inverter (R22) Heat Pump RY-series in combination with the Low & Medium Static Pressure Duct (FDYB/FDYM), Daikin extends its Sky Air product portfolio for R22 refrigerant and widens its choice for ceiling concealed applications in area’s using R22 units. Mainly the RY + FDYB/M series will provide: A product combination with a wide capacity range going from class 30 to 160 (2.7kW to 16.4kW) offering comfort living, greatest flexibility and easiness in installation locations, good COP/EER and static pressure. An outdoor unit with a wide operation range (to +46°C in cooling and -9°C in heating), combinable with low / medium static indoors and available in 1 and 3 phase power supply versions. 4. Conclusion