Luminosity Measurement and Monitoring in ATLAS LHC Machine-Experiments Workshop On behalf of ATLAS Collaboration Laura Fabbri Thanks to LUCID people.

Slides:



Advertisements
Similar presentations
ATLAS Tile Calorimeter Performance Henric Wilkens (CERN), on behalf of the ATLAS collaboration.
Advertisements

Introduction This project used cosmic rays to test a prototype Minimum Bias Trigger Scintillator (MBTS) that will be used in the ATLAS experiment at CERN.
LHC/HERA workshop, WG 4 (17. Jan. 2005)
June 6 th, 2011 N. Cartiglia 1 “Measurement of the pp inelastic cross section using pile-up events with the CMS detector” How to use pile-up.
LHC Luminosity Workshop December 9, 2002 Gregory Snow (University of Nebraska) 1 Toward a Measurement and Monitoring of pp Luminosity in the CMS Experiment.
02/10/2004 Minimum Bias Trigger Scintillator Counters (MBTS) for early ATLAS running M.Nessi ATLAS week, Freiburg.
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
Recent Electroweak Results from the Tevatron Weak Interactions and Neutrinos Workshop Delphi, Greece, 6-11 June, 2005 Dhiman Chakraborty Northern Illinois.
The ALFA project in ATLAS Antwerpen 25/10/07 Per Grafstrom.
Luminosity measurments roadmap for luminosity determinations relative luminosity monitors luminosity from machine parameters luminosity from physics processes.
Luminosity measurements and forward physics in ATLAS forward detectors luminosity calibration and monitoring forward physics beyond luminosity Hasko Stenzel.
Machine induced background in ALFA The ALFA detector elastic scattering and luminosity background generation, rejection and subtraction impact on luminosity.
Forward Detectors and Measurement of Proton-Antiproton Collision Rates by Zachary Einzig, Mentor Michele Gallinaro INTRODUCTION THE DETECTORS EXPERIMENTAL.
M. Gallinaro - "Physics with the CT-PPS project" - LHC Forward - Sep. 23, Michele Gallinaro LIP Lisbon (on behalf of the CMS and TOTEM collaborations)
Beam profile measurements based on modern vertex detectors and beam-gas interactions Slides from: Colin Barschel - TIPP 2014 third international conference.
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
W properties AT CDF J. E. Garcia INFN Pisa. Outline Corfu Summer Institute Corfu Summer Institute September 10 th 2 1.CDF detector 2.W cross section measurements.
1 Luminosity monitor and LHC operation H. Burkhardt AB/ABP, TAN integration workshop, 10/3/2006 Thanks for discussions and input from Enrico Bravin, Ralph.
PMF: front end board for the ATLAS Luminometer ALFA TWEPP 2008 – 19 th September 2008 Parallel Session B6 – Programmable logic, boards, crates and systems.
Performance of PHENIX High Momentum Muon Trigger 1.
Calibration of the ZEUS calorimeter for electrons Alex Tapper Imperial College, London for the ZEUS Collaboration Workshop on Energy Calibration of the.
Antonio Zoccoli RICH 2007 – Trieste 1 October 20, 2007 LUCID* - A Cherenkov tubes based detector for monitoring the ATLAS luminosity LUCID* - A Cherenkov.
ATLAS Forward Detector Trigger ATLAS is presently planning to install forward detectors (Roman Pot system) in the LHC tunnel with prime goal to measure.
Status of Beam loss Monitoring on CTF3 Results of Tests on LINAC and PETS as R&D for TBL Anne Dabrowski Northwestern University Thibaut Lefevre CERN CTF3.
14/03/2007A. Sbrizzi, HERA-LHC Workshop, DESY 1 Luminosity measurement in ATLAS and CMS A.Sbrizzi - University of Bologna, Italy.
Luminosity Measurement with the ATLAS Forward Calorimeter
Calibration of the CMS Electromagnetic Calorimeter with first LHC data
AFP Introduction September 10th 2014 M. Bruschi, INFN Bologna (Italy) 1.
1 Luminosity measurement at LHC Charged Higgs Workshop Uppsala September 2008 Per Grafstrom CERN.
BES-III Workshop Oct.2001,Beijing The BESIII Luminosity Monitor High Energy Physics Group Dept. of Modern Physics,USTC P.O.Box 4 Hefei,
Apollo Go, NCU Taiwan BES III Luminosity Monitor Apollo Go National Central University, Taiwan September 16, 2002.
1 Triggering on Diffraction with the CMS Level-1 Trigger Monika Grothe, U Wisconsin HERA-LHC workshop March 2004 Need highest achievable LHC Lumi, L LHC.
All Experimenters MeetingDmitri Denisov Week of July 7 to July 15 Summary  Delivered luminosity and operating efficiency u Delivered: 1.4pb -1 u Recorded:
Oct 6, 2008Amaresh Datta (UMass) 1 Double-Longitudinal Spin Asymmetry in Non-identified Charged Hadron Production at pp Collision at √s = 62.4 GeV at Amaresh.
Precision Measurements of W and Z Boson Production at the Tevatron Jonathan Hays Northwestern University On Behalf of the CDF and DØ Collaborations XIII.
LHCb: Xmas 2010 Tara Shears, On behalf of the LHCb group.
FIT (Fast Interaction Trigger) detector development for ALICE experiment at LHC (CREN) Institute for Nuclear Research (INR RAS) National Research Nuclear.
The RICH Detectors of the LHCb Experiment Carmelo D’Ambrosio (CERN) on behalf of the LHCb RICH Collaboration LHCb RICH1 and RICH2 The photon detector:
30 June 2009EDS '09 Antonio Zoccoli1 ATLAS and the Forward Physics Antonio Zoccoli Università & INFN – Bologna Antonio Zoccoli Università & INFN – Bologna.
Magnetized hadronic calorimeter and muon veto for the K +   +  experiment L. DiLella, May 25, 2004 Purpose:  Provide pion – muon separation (muon veto)
Luminosity Monitoring Issues  ZDC  what’s the advantage?  problems  BBC  can they do it? A. Drees QCD critical point workshop, Mar
First measurements in Pb—Pb collisions at  s NN =2.76 TeV with ALICE at the LHC M. Nicassio (University and INFN Bari) for the ALICE Collaboration Rencontres.
__________________________________ C. Avila, small x workshop, Sep ELASTIC SCATTERING IN D0 EXPERIMENT Carlos Avila Universidad de Los Andes Bogota,
1 Plans for first beams - - triggers from the BRM group (BSC, BPTX) Gábor Veres for the BRM group CMS Trigger Technical Coordination Meeting 8 October,
00 Cooler CSB Direct or Extra Photons in d+d  0 Andrew Bacher for the CSB Cooler Collaboration ECT Trento, June 2005.
ATLAS-ALFA as a beam instrument Sune Jakobsen (BE-BI-PM and PH-ADO) on behave of the ATLAS-ALFA community LS1 LBOC meeting
CP violation in B decays: prospects for LHCb Werner Ruckstuhl, NIKHEF, 3 July 1998.
Measurement of inclusive jet and dijet production in pp collisions at √s = 7 TeV using the ATLAS detector Seminar talk by Eduardo Garcia-Valdecasas Tenreiro.
Diffraction at DØ Andrew Brandt University of Texas at Arlington E   Run IRun II Low-x Workshop June 6, 2003 Nafplion, Greece.
Penny Kasper Fermilab Heavy Quarkonium Workshop 21 June Upsilon production DØ Penny Kasper Fermilab (DØ collaboration) 29 June 2006 Heavy Quarkonium.
Performance of the ATLAS Trigger with Proton Collisions at the LHC John Baines (RAL) for the ATLAS Collaboration 1.
DØ Beauty Physics in Run II Rick Jesik Imperial College BEACH 2002 V International Conference on Hyperons, Charm and Beauty Hadrons Vancouver, BC, June.
May 26-27, 2005Tadashi Nomura (Kyoto U), KRare05 at Frascati, Italy1 KOPIO Beam Catcher Tadashi Nomura (Kyoto U.) Contents –What is Beam Catcher? –Concept.
Inclusive cross section and single transverse-spin asymmetry of very forward neutron production at PHENIX Spin2012 in Dubna September 17 th, 2012 Yuji.
Maarten Boonekamp Precision measurements with Atlas 1 Precision measurements (?) with Atlas, at the LHC (emphasis on QCD) Maarten Boonekamp CEA-Saclay.
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
1 Underlying Event studies & Charged particle multiplicities in inelastic pp events with the ATLAS.
QCD Prospects for ATLAS Rainer Stamen Universität Mainz On behalf of the ATLAS collaboration QCD 06 Montpellier, July 3rd 2006.
FORWARD ATLAS {major contributions from Per Grafstrom (CERN), Michael Rijssenbeek (Stonybrook), Brian Cox (Manchester} Andrew Brandt Luminosity measurement.
Open and Hidden Beauty Production in 920 GeV p-N interactions Presented by Mauro Villa for the Hera-B collaboration 2002/3 data taking:
K. Holubyev HEP2007, Manchester, UK, July 2007 CP asymmetries at D0 Kostyantyn Holubyev (Lancaster University) representing D0 collaboration HEP2007,
Integration of forward physics detectors into the LSS of the LHC D. Macina (TS/LEA) Technical Support 2004 Workshop.
Detector status and commissioning: LUCID
First data from TOTEM experiment at LHC
Emmanuel Tsesmelis TS/LEA 26 January 2007
Particle detection and reconstruction at the LHC (IV)
Recent Results from TOTEM
Tadashi Nomura (Kyoto U), KRare05 at Frascati, Italy
PID electronics for FDIRC (Focusing Detector of Internally Reflected Cherenkov light) and FTOF (Forward Time of Flight) Christophe Beigbeder and Dominique.
Installation, Commissioning and Startup of ATLAS & CMS Experiments
Presentation transcript:

Luminosity Measurement and Monitoring in ATLAS LHC Machine-Experiments Workshop On behalf of ATLAS Collaboration Laura Fabbri Thanks to LUCID people

January 26, 2007LHC Machine and Experiments Workshop2 OUTLINE Motivations for Luminosity measurements ATLAS’ forward detectors Techniques for Luminosity measurements Conclusions

January 26, 2007LHC Machine and Experiments Workshop3 Motivation I Cross section for “Standard” processes ttbar W/Z … New Physic evidence Deviation from SM prediction Higgs production study Cross section tan  in MSSM Higgs, … [ATLAS-TDR-15, May 1999]  H  BR tan  Luminosity dominating errors for many studies Goal ~ 2-3% accuracy

January 26, 2007LHC Machine and Experiments Workshop4 Motivation II Fast control of running conditions Determine beam background Prevent beam loss Efficiently use of beam and optimize yield Trigger optimization (pre-scaler) Provide online luminosity measurement for LHC Study beam deterioration Monitor luminosity bunch-by-bunch

January 26, 2007LHC Machine and Experiments Workshop5 L > Forward ATLAS L  L  L  L  10 27

January 26, 2007LHC Machine and Experiments Workshop6 p T max ~  s exp( -  )  coverage MBTS TILE Inelastic MBTS LoI just presented

January 26, 2007LHC Machine and Experiments Workshop7 2 symmetric arrays of 20 x 1.5 m polished Aluminum tubes (Ø=1.5cm), filled with C 4 F 10, surrounding the beam pipe and pointing at the IP (Z~17 m ) It fit in available space & has low mass (< 25 kg/end) LUCID: luminosity monitor LUCID : “LUminosity measurement using Cerenkov Integrating Detector Charged particles emit Cherenkov light at ~3 degrees Photons propagate along the tube with multiple reflections (~2.6) and are read out by a PMT (Radiation hard)

January 26, 2007LHC Machine and Experiments Workshop8 The signal amplitude is used to measure the event track multiplicity (  µ  L) The PMT time resolution of a few ns could be used to measure bunch-by-bunch luminosity PMT readout - Baseline 4 out of 20 tubes are readout by MaPMTs via fiber bundles (To test new detector design for high luminosity) LUCID: Light Detection

January 26, 2007LHC Machine and Experiments Workshop9 The LUCID Data Flow LUCID Run Control Luminosity Block IS CTP/LVL1 Dead-time Pre-scale LVL2 + EF Pre-scale ATLAS TDAQ Offline Luminosity Luminosity data stream Control Room Conditions Database Analysis LUCID Trigger L1A ~100 kHz (~1 kHz) ~200 Hz (~2 Hz) ROS… S-link Online Lum. Scalers Cross checks with CTP Monitoring SBC (VME) The LUCID information will be available: 1.in the global ATLAS triggered event 2.in the online monitor 3.to possibly trigger interaction events or reject high multiplicity events DCS

January 26, 2007LHC Machine and Experiments Workshop10 LUCID Performances Cherenkov photons from gas + PMT window Cherenkov photons from PMT quartz window 1 interaction per event Sensitive to IP-pointing tracks above threshold Much shorter paths for non pointing secondaries The response of the detector is linear with both PMT and fiber read-out

January 26, 2007LHC Machine and Experiments Workshop11 Beam Condition Monitor 4 diamond sensors: 1x1 cm µm thick 5 cm radius from the beam 1.8 m from the IP on each side Pseudo-rapidity coverage 3.9< |  <4.1 Radiation hard (50 Mrad, π/cm 2 )

January 26, 2007LHC Machine and Experiments Workshop12 BCM BCM is foreseen to provide monitoring information about anomalous beam conditions (beam-gas and beam-collimator interaction events, beam loss) Designed to work for the full luminosity range of LHC Designed with a sufficient time resolution to identify individual bunch crossings (Rise-time ~ 1 ns, Width ~ 3 ns, Restoration ~ 10 ns) TAS events: t=12.5, 37.5 … ns Distinguish interactions from background via time of flight (interactions in time, background out of time on one side) The amplitude of the signal can be used to determine the number of particles that transverse the detector Possibility for luminosity measurement is under study

January 26, 2007LHC Machine and Experiments Workshop13 Minimum Bias Trigger Scintillator Counters (MBTS) Wedge-shape plastic scintillators installed on the front face of LAr end-cap cryostat (Z=±3.6 m) Each scintillator cover  = 2  /8 and consist of two separated sections (2.1<  inn < 2.8, 2.8<  out <3.8) Material: Polystyrene doped with fluorescing agent The light emitted is collected by wavelength-shifting optical fibers embedded in grooves in the scintillator These fibers are connected to the PMTs and readout electronics designed for the TileCa inner  outer  R min = 14 cm R max = 88 cm

January 26, 2007LHC Machine and Experiments Workshop14 MBTS MBTS goal is trigger on minimum bias events and veto halo events during the commissioning phase (L< 5 x cm -2 s -1 ) It is able to detect 1 minimum ionizing particle It provides LVL1 trigger information and data to the ROS for triggered events Can be used to determine luminosity by counting the minimum bias trigger rate The lifetime of the detector is limited by expected significant radiation damage

January 26, 2007LHC Machine and Experiments Workshop15 Calorimeters TileCal Minimum bias monitor via integrated anode current of the PMTs (high luminosity) LAr Minimum bias monitor via integrated high voltage current Relative luminosity information will be provided from the local monitor systems outside the event stream

January 26, 2007LHC Machine and Experiments Workshop16 RP IP 240m RP Roman Pots Two RP stations with top and bottom vertical pots, separated by 4 m, at each side 240 m from IP1 Roman Pots for ATLAS

January 26, 2007LHC Machine and Experiments Workshop17 t= t= σ 15 σ ATLAS’ Roman Pots Measure elastic pp-scattering down to very small angles (~3 μrad)  Coulomb region f C ≈f N operate tracking detectors very close to the beam, 10 σ = 1.2 mm (position accuracy ~ 10  m) detector resolution  d = 30  m (t-resolution dominated by beam divergence) radiation tolerance 100 Gy/yr (dominated by beam halo) rate capability O(1 MHz) and time resolution O(5 ns) Measure elastic pp-scattering down to very small angles (~3 μrad)  Coulomb region f C ≈f N operate tracking detectors very close to the beam, 10 σ = 1.2 mm (position accuracy ~ 10  m) detector resolution  d = 30  m (t-resolution dominated by beam divergence) radiation tolerance 100 Gy/yr (dominated by beam halo) rate capability O(1 MHz) and time resolution O(5 ns) V-measurement detector U-measurement detector scintillator plate for triggering

January 26, 2007LHC Machine and Experiments Workshop18 Techniques for Luminosity measurements Use a relatively well known, copious, process: Use a relatively well known, copious, process: Inclusive inelastic pp cross- section large acceptance at small angles µ = avg. # of interactions/b.c.µ = avg. # of interactions/b.c. f = frequency of bunch crossingsf = frequency of bunch crossings  in = tot inelastic cross-section  in = tot inelastic cross-section L = inst. luminosityL = inst. luminosity Use a good estimator Use a good estimator Measure the fraction of crossings with pp interactions Use: prob. of no int. Direct counting # of pp interactions Counting particles Counting hits Cross-calibrate Cross-calibrate Machine information Roman Pots Rarer, clean, better understood physic processes Use dedicated detector: Use dedicated detector:

January 26, 2007LHC Machine and Experiments Workshop19 Calibration Strategy Measured by LUCID Measured by LUCID (at low luminosity  <1) Given by calibration method LUCID with 200 tubes (No Secondaries) Calibration Constant: A =  pp x  inel Run LUCID in parallel with calibration measurement Advantage of “Parallel” Calibration Measured: Not easy at high precision, e.g. CDF vs E811 discrepancy Calculated: Acceptance shown at the Tevatron to be difficult to calculate in forward region Calculated  and measured  tot used for consistency cross checks [ATLAS-LUM-PUB ]

January 26, 2007LHC Machine and Experiments Workshop20 Whole Calibration Methods Initially, LHC Machine Parameters (Precision: ~10%) Medium term Physics processes, W/Z &  / ee (Precision: ~5-10%) Late 2009 – Early 2010 Roman Pot (ALFA) measurement (Precision: ~2-3%) Including estimated latency for data-taking and analysis

January 26, 2007LHC Machine and Experiments Workshop21 Conclusions A big effort is made by the ATLAS collaboration to provide many methods to monitor luminosity Different detectors based on different working techniques are studied and ready for installation Monitors’ information are available both in the ATLAS TDAQ than outside the event stream Luminosity will be monitored bunch-by-bunch and synchronized with LBs Absolute calibration against Machine Luminosity and Roman Pots. Calculated efficiency (  ) and measured  tot only used for consistency cross checks

January 26, 2007LHC Machine and Experiments Workshop22 Backup

January 26, 2007LHC Machine and Experiments Workshop23 Luminosity with Collision (zero) counting method Mean # interactions per (any) BC 0 bin Measure the average of the Poisson distribution by measuring the 0 bin. Collision Rate “Zero” Rate Advantages: Less sensitive to ADC calibration Formula is correct at every L Disadvantages Not linear at higher luminosity (   1) Statistically limited at very high L ( ) Detection efficiency of one interaction Linear relation between measured quantity and luminosity at low luminosity (  << 1)

January 26, 2007LHC Machine and Experiments Workshop24 Particle Counting (Baseline Method) Constructed to be Linear even in Pile-Up Region Mean # Particles per BC Mean # Particles per Detected Interaction (measured at low lum. where the prob. For >1 int./BC is very small) Detector Requirements: Acceptance coverage sensitive to min. bias event rate Time resolution to make measurement for individual BCs Capable of counting particles Calibrated by efficiency (acceptance) and inelastic cross section from calibration measurement or calculations

January 26, 2007LHC Machine and Experiments Workshop25 Start up Physic Processes QED: small  QED pp  (p+  *)+(p+  *)  p+(  )+p Low rate (<< 1 Hz) still at L=10 34 cm -2 s -1 Process calculated with  1% accuracy EW: W/Z  leptons Theoretically well understood processes (calculated till NNLO) High rate:  6Hz for Z    ,  60Hz for W    at L=10 34 cm -2 s -1 Online monitor at high luminosity  L / L ) syst ~ 4-6% *;  L / L ) stat ~ 1-5% * QCD:  tot ~ 100 mb Roman Pots at dedicated luminosity (L≈10 27 cm -2 s -1 ) and optic Absolute Luminosity L Counting of the number of bunch crossings with/without interaction Online monitor  Relative Luminosity L No Monitor Online * Small statistical error (<1%)  homogeneous samples with at least 10K-100K ev