Dialling the Last Two Digits The final selector, although large, is a fairly straightforward piece of equipment with straightforward facilities much as.

Slides:



Advertisements
Similar presentations
Electricity Chapter 13.
Advertisements

Electricity The Quick Version.
Chapter Eight: The Telephone System
Circuits Electromotive Force Work, Energy and emf
N:2-3 / Series and Parallel Circuits
BASIC TELECOMMUNICATIONS
Copyright © 2014 Delmar, Cengage Learning Electrical Accessories Instructor Name: (Your Name) 10 CHAPTER.
Capacitors and/or TV (not Emf). 1. An empty capacitor does not resist the flow of current, and thus acts like a wire. 2. A capacitor that is full of charge.
Register Digital Multimeter Usage Click Register to begin the course.
The Telephone Instrument
1 Group Selector P Wire Battery Testing When a group selector hunts around a level for a free outlet, it needs to have the free outlets designated by a.
Week 3 Electrical Circuits and Components. It’s a Radio!
Transmission Bridges All calls through an exchange require the use of a transmission bridge. The main requirements of a transmission bridge are : 1) The.
Jumpering a New Line Providing a new line usually involves two jumpers, though some small exchanges may only require an MDF jumper. This page deals with.
CircuitProtection, Tips, and Troubleshooting Spring 2015 ECE 445.
Register Digital Multimeter Usage Click Register to begin the course.
Register Digital Multimeter Usage Click Register to begin the course.
1 Introduction to Strowger Strowger is an exchange system built around electro-mechanical switches that can drive or be stepped around a bank of outlets.
The DC (direct current) motor:
Basic Electrical Systems Theory and Repair
Introduction to Digital Multimeters
1 Selector Stepping All calls made through a Strowger exchange require that pulses from the customer's dial step the magnets in the selector mechanisms.
 Four Components of a circuit  Power supply  Conductor  Load device  Controlling device  Power Supply  Generator  Line source (wall outlet)  Transformer.
Proceed INTRODUCTION INTRODUCTION / Maybe think about this situation: You are getting ready for Christmas, Channukah, and / or the Winter Solstice and.
Chapter 18 Direct Current Circuits. Chapter 18 Objectives Compare emf v potential difference Construct circuit diagrams Open v Closed circuits Potential.
Electromagnetic Induction
1 Pulsing Dial Limits : The nominal dial characteristics are speed = 10 pps, ratio = 2/3 break, 1/3 make. In practice dials are set to maintenance limits.
Electricity and Magnetism
The world is filled with electrical charges:
Register Digital Multimeter Usage Click Register to begin the course.
The UAX13 - Getting Dial Tone
Chapter Electric Current
Pneumatics.
Chapter 31 Faraday’s Law Electricity generator, or from B to E. 1.Battery  Chemical emf 2.Motional emf 3.Faraday’s Law of Induction 4.Lentz Law about.
William Stallings Data and Computer Communications Chapter 9 Circuit Switching.
1 The UAX13 - Dialling the First Digit The UAX13 Group Selector is seized by a calling earth from the associated linefinder and returns a holding earth.
CIRCUITS Chapter Electric Circuit An electrical device connected so that it provides one or more complete paths for the movement of charges.
PHYSICAL SCIENCE Electricity Part 3: Circuits Circuits Objectives Use schematic diagrams to represent circuits. Distinguish between series and parallel.
Telecommunication II.
35 Electric Circuits Electrons flow from the negative part of the battery through the wire to the side (or bottom) of the bulb through the filament inside.
Electricity & Magnetism Electricity. Beginning Task: Trade Science Fair Assignment #4 with your partner Use the Peer Review Form to provide feedback to.
S.MORRIS 2006 Currents CIRCUITS More free powerpoints at
Walks, Paths and Circuits. A graph is a connected graph if it is possible to travel from one vertex to any other vertex by moving along successive edges.
~Moving Charge Put to Use
Main contacts closed – RED Colour with ON
Electrical Circuits ~Moving Charge Put to Use The Circuit All circuits, no matter how simple or complex, have one thing in common, they form a complete.
Physics 12 Mr. Jean November 13 th, The plan: Video clip of the day Drawing circuits Working with circuit diagrams Basic Ohm’s Law.
1.Mouths are quiet. 2.Begin the quick review section of your notes. 3.Raise your hand if you need something.
Electric Circuits. Electric Current – the movement or flow of electric charges from one place to another. Electric Circuit – a controlled path in which.
ACTIVE LEARNING ASSIGNMENT SUBJECT: DC Machine and Transformer TOPIC: Necessity of Starter and its Types Branch: Electrical Engineering Prepared By :-Charan.
Bell Ringer From yesterday’s lab… …Do you believe holiday decoration lights are wired in series or in parallel?
+ Electric Circuits Parallel Circuits and Diagrams.
Basic Electrical Systems Theory and Repair Chapter 29 Page 387.
TELEPHONE TRANSMISSION SYSTEMS
ACTIVE LEARNING ASSIGNMENT TOPIC NAME :- DC MOTOR STARTERS ELEMENTS OF ELECTRICAL DESIGN ( ) AY Course co-ordinator:- SAMIR B PATEL PREPARED.
PS-6.9: compare the functioning of simple series and parallel electrical circuits PS-6.10: compare alternating current and direct current in terms of the.
Using a Multimeter.
DS200 EEPROM PROGRAMMING.
ABS COMPONENTS AND OPERATION
Electricity and Magnetism
Lesson 4 Electricity Part 3.
Electrical Safety in the Home
Electric Energy Notes.
Unit 2.4 Electric Circuits
1. Strowger final selector – idle state
BUILDING CIRCUITS: Schematics.
Current electricity Ch. 34
Presentation transcript:

Dialling the Last Two Digits The final selector, although large, is a fairly straightforward piece of equipment with straightforward facilities much as final selectors in any exchange. The main addition is a "trunk offering" facility built into each selector. Otherwise this is a simple 100 outlet final selector. The selector normally presents a 150 ohm battery condition on the incoming P wire to indicate that it is free. The group selector extends the caller's loop through to operate the final's A relay etc. This causes a holding earth to be returned on the P wire. Two digits are dialled. The first steps the selector vertically, the second digit steps the selector into the bank to rest on the multiple contacts of the called line. The selector tests for a free line. If busy the selector returns busy tone to the caller. If spare the selector switches to an NU relay, hopefully spare at the time, which returns NU tone to the caller. If free, the selector busies the called line, operating the K relay in the called line circuit and thus removing the bridging apparatus. It then connects ringing and ring return battery conditions to the called line to ring the distant bell. When the called line answers with a loop, the selector recognises this and connects the caller and called lines together for speech. It also sends a pulse back along the meter wire to operate the caller's meter in his line circuit. The selector clears down and removes the P wire holding earth when the calling loop is removed. This clears down the linefinder and group selector as well. If the called line clears but for some reason the caller does not also clear down, the final selector times out, to release the connection and leave the caller "parked" on his line circuit. It is possible for a consecutively numbered group of lines all placed on one level to be treated as a "PBX" group. ie If the first line of the group is dialled, the selector will hunt over the group to find the first free line to the PBX. The final selector will also allow a distant operator to break into an existing call and "trunk offer" a call to the busy line. This Trunk Offering facility is not in use at Norchard.

Dialling the Last Two Digits This diagram has been taken from Atkinson as it is simple to look at. However there are some changes when a current diagram is inspected. In particular, int batt and eth is no longer used. The selector normally presents a 150 ohm battery on the incoming P wire to indicate that it is available. The previous selector extends the caller's loop through to the final selector on the incoming - and + wires. This operates relay A. A1 operates relay B. B6 removes the P wire battery and replaces it with an earth. B4 operates relay C (CD in the modern design). When the caller dials the penultimate digit A1 repeats the pulses to the vertical magnet. On the first pulse the selector steps up to level 1 and operates its N springs. N2 short circuits the 700 ohm winding of the C (CD) relay which becomes slow to release. The magnet current pulses in the 5 ohm winding maintain C (CD) during pulsing. Also, when A1 releases during the pulsing it short circuits the B relay, which becomes slow to release. Relay B also holds during pulsing. At the end of the dial pulse train, relay A remains operated, but the magnet current ceases and C (CD) releases. C3 operates relay E from the vertical magnet battery to the N2 earth. E6 removes the short circuit from the C (CD) relay so that it can re-operate. Relay E holds to the vertical magnet battery via contacts C3 and E1.

The caller now dials the final digit and the A1 contact sends current pulses to the rotary magnet via E4, the 5 ohm C (CD) winding, C1 A1 and the B1earth. The selector steps around the level to the required number. On the first step, the NR springs are operated by the selector. NR2 again short circuits the 700 ohm winding of relay C (CD) making the relay slow to release. Relay C (CD) holds due to the magnet current flowing through the 5 ohm winding. When the last digit has been completed the final selector is standing on the required line and the magnet current ceases allowing relay C (CD) to release.

The selector now has to test the dialled line to see if it is free or busy. A free condition is denoted by a 1300 ohm K (or NU) relay battery on the P wire. The line will be busy if the P wire is "dis" or earthed. When C (CD) releases, C3 disconnects relay E which releases slowly. E6 takes the short circuit off the C (CD) relay to allow it to re-operate again. Thus C (CD) releases for the short period of the release lag of relay E. During this period, C2 connects the H relay to the called P wire to see if there is a battery present. If the line is busy, C2 cannot operate relay H (and HR), but when E releases E2 can operate relay G to the NR2, N2, B1 earth. G6 connects busy tone to the A relay 570 winding, which uses the relay as a transformer to send the tone to the caller. Should the caller dial any further digits, they are ineffective as C1 has disconnected the magnet circuits.

If the line is free, C2 operates relay H to the 1300 ohm battery on the P wire. H2 operates relay HR. H4 earths the P wire to busy the called line and to operate the K relay in the line circuit and so remove the bridging apparatus. H6 holds relay H. When E2 releases, relay J is operated. J1 connects intermittent ring earth to the + wire to the called line, whilst HR2 connects ring return battery to the - wire. J2 connects ring tone to the A relay and caller's telephone. The AC from the ringer passes through the called line's capacitor and bell in the telephone to ring the bell. DC cannot flow yet and so relay F, being very slow to operate will not be affected by the AC component. When the called line answers, the telephone loop allows DC to flow from the ring return battery to the ringer earth. This operates relay F. F2 removes the short circuit from the 400 ohm winding to hold the relay. F5 and F6 extend the called line's loop to operate relay D and to connect the caller and called lines together via the transmission bridge of the selector. So long as the called line presents an ordinary loop, relay D will operate. D1 re-operates relay E. E2 releases relay J slowly. Whilst E is operated and J is still releasing, E5 and J4 return a 150 ohm battery pulse on the M wire to operate the meter in the caller's line circuit. J2 removes the ring tone from the A relay.

The two lines are now connected together and are being fed line current via the A and D relays. At this stage the following relays are operated during the call. Relays A, B, E, F, H, HR. B6 is holding an earth onto the incoming P wire to hold the connection from the linefinder and group selector. H4 is holding an earth on the outgoing P wire to hold the K relay in the called line circuit and to keep that line busy.

Clear Down Should the caller clear first, relay A releases when the loop disappears. Relay B releases. B6 removes the holding earth from the P wire, allowing the linefinder and group selector to restore also. B1 releases relays H, HR, E and F. H1 and H3 release relay D. H5 completes a self drive circuit for the rotary magnet which restores the selector to its normal position. When the selector is normal, the N springs restore and N2 reapplies the 150 battery to the incoming P wire to indicate that the final selector is free again. Should the called line clear first, relay D releases. If the caller now clears the restoration of the selector is as above. If the caller does not clear, then the selector times out. D2 connects the TM relay to the TP start wire. TM operates when the next start pulse arrives and holds to the TP hold wire. Eventually TM3 allows relay G to operate to the TP release wire. G4 removes the A relay earth to release the A relay. Relay A releases relay B etc and the selector restores to normal. The loss of P wire earth at the caller's line circuit causes the caller to be parked on to the line circuit P relay. Mean while the final selector is available for further calls.

PBX Group Working If a PBX group of lines is allocated to a level of the final selector multiple, the first line of the group is marked by connecting a battery condition to the P2 wire on the multiple. Intermediate lines are not marked on the multiple and last lines are marked with an earth. These markings are made with straps on the multiple connections on the rear of the rack. If the first line of the group is free, it is seized as above. Relay HS may operate momentarily to the marking P2 battery but it will not hold once relay C re-operates. If the first line is busy, then relay H does not operate but HS will when C5 releases. HS2 holds Relay HS. Relay E releases and relay C (CD) re-operates as before. C4 and HS1 energise the rotary magnet which steps the selector to line 2 of the group. As the selector finishes its rotary stroke the interrupters operate and R1 operates the G relay. G3 disconnects the magnet which releases. R1 restores to normal releasing relay G G3 reconnects the magnet which steps the selector to line 3. This process continues while it is stepping (quite slowly) over the PBX lines in sequence.

When the wipers step onto a free line, the P wire battery operates relay H in series with the G relay. H2 operates relay HR as before. H5 disconnects the rotary magnet path. HR6 releases relay G (HR3 short circuits the other winding). C5 and H6 disconnect relay HS which releases. HS4 now operates relay J and the call proceeds as for an ordinary line. If the last line of the group is also busy then the selector encounters an earth on the P2 wiper. This earth will hold relay G via the 2000 ohm resistor and prevent any further stepping. Relay H will not have operated so that contact G5 can release relay HS. G6 and HS5 connect busy tone to the A relay for transmission to the caller.

The trunk offering facility is not described as it is unlikely that it will be in use at this time.