Fiber Optic Quality Tests Zisis Papandreou SPARRO Group, Regina Hall D Collaboration Meeting Bloomington, Indiana November 1 st, 2001.

Slides:



Advertisements
Similar presentations
Alignment systems for GlueX GlueX Collaboration Meeting Bloomington, Indiana May 20-22, 2004 Courtesy of Dimos Sampsonidis, Aristotle University of Thessaloniki.
Advertisements

Michael Weber SAIC Intern Purdue Technology Center August 10, 2010.
Spectrophotometric Determination of Iron Using 1,10-Phenanthroline
M3 Instrument Design and Expected Performance Robert O. Green 12 May 2005.
OL 750 Diffuse Spectral Reflectance Measurement System
Copyright © 2009 Pearson Education, Inc. Lecture 3 – Physical Optics b) Diffraction.
 Incorporated June, 2004  Global supplier of full range UV-VIS-NIR spectrometers for field portable, lab and general purpose photonics applications 
7. Beer’s Law and It’s Implications for Instrument Construction.
Takashi Matsushita Imperial College T. Matsushita 1 Station five – assembly/QA.
Applications of CCD Array Spectrometers in Undergraduate Education at EIU Jonathan Blitz and Daniel Sheeran Department of Chemistry.
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
K-Space Associates, Inc. kSA BandiT: Band-edge Thermometry.
Status of MICE Tracker System H. Sakamoto, Osaka University (on behalf of the MICE Collaboration) International Muon Ionization Cooling Experiment (MICE)
Wojtek Skulski CERN Oberon Day March /2004 Experiment control and data acquisition using BlackBox Component Builder Wojtek Skulski Department of Physics.
What’s in the Box. Purpose Reference Communication Identification.
© DIAMOND SA / / 1 CLEANING A focal point in fiber optics.
Berkeley workshop summary Redundancy : dual detector Field of view : 3”x6” Spectrograph length goal: < 400 mm Isostatic mount on the base plate with control.
Broadband Integrating Transmittance/Reflectance Spectrometer (BITS) Tony Wexler Crocker Nuclear Laboratory University of California, Davis Presented at.
CMS UPGRADE CAPILLARY TUBE PROFILING. CAPILLARY TUBES EVALUATION Radiation damage Transmission Mixing Scintillating Quartz Tube Water/ Air EJ309 Fiber.
1 HF Laser/LED Calibration Studies L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH 1->9 light splitter w/ pulsed.
A Company Selling Technology and not just a Product.
UoA calibration system1 Modular calibration/monitor system for the GlueX BCAL +FCAL University of Athens * G.Voulgaris E.G.Anassontzis P.Ioannou E.Kappos.
Page 1 © 2008 IDEAL INDUSTRIES IDEAL Micro OTDR Oktober 2008 Konstantin Hüdepohl.
5 Components Common to All Optical Spectrometers Source Transparent Sample Holder Wavelength Selector Radiation Detector Signal Processor and Readout.
Corner Raft Test Station Kirk Arndt, Ian Shipsey Purdue University LSST Camera Workshop SLAC Sept , 2008.
BCAL R&D GlueX Collaboration Meeting Newport News, Virginia September 9-11, 2004 George Lolos, Zisis Papandreou.
HFA Robot Guarding Robot / Conveyor Guarding Built to Customer Specifications ● Optional Doors with Safety Interlock Switch ● Stand Alone Units and / or.
World Leader In Gas Detection & Sensor Technology Stand Alone Calibration Station SM 2000 Series.
Near Field Photonic Crystal Multi- Mode Spectrometer Adam Saltzman 4/19/02 BME 265 Dr. J Izatt Collaborators: Vasily Astratov UNC Chalet,
Spectrophotometer Prof.Dr. Moustafa M. Mohamed Vice Dean Faculty of Allied Medical Science Pharos University in Alexandria, EGYPT.
Motivation There is a consensus that it is not possible to obtain a software (π 0 ) calibration with few days delay (this is to be verified, this is the.
Optronic Laboratories Inc. OL Series 750 Automated Spectroradiometric Measurement System Optronic Laboratories Inc. OL Series 750 Automated Spectroradiometric.
N 2 Laser 300  QQ 150m HF  HF + 9 PMT Boxes  QP Calib Box 1  4 Counting Room HF Calibration Optical Fiber Path 9 PMT Boxes / Quad 24 PMT Tubes.
Electron Spectrometer Work Package Simon Jolly 19 th May 2014.
SPARRO Group, University of Regina 1 Barrel Calorimeter Status Quo Zisis Papandreou University of Regina GlueX Collaboration Meeting JLab, December 11-13,
CLIC meeting Jan Kovermann. Task: Analysis of the light which is emitted by a breakdown Study the breakdown time dependence of the BD light emission.
1 Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH.
Inserire curva di attenuation length normale Warning do not trust the error Warning Preliminary results 0.8 mm 250 ppm part 1 - measure 2 Fit from 0 to.
ECAL LED monitoring system upgrade Pavel Shatalov ITEP, Moscow, Russia Yuri Guz IHEP Protvino, Russia.
GlueX Detector Review, October 2004 BCAL GlueX Detector Review Newport News, Virginia October 20-22, 2004 George J. Lolos University of Regina.
MICE Target Development Lara Howlett University of Sheffield.
Status of cosmic-ray test of the SciFi prototype and SciFi software in G4MICE M. Yoshida (Osaka Univ.)
OL 750 Measurement Systems OL 750 Measurement Systems Optronic Laboratories, Inc.
Part 3  Transmission Media & EM Propagations.  Provides the connection between the transmitter and receiver. 1.Pair of wires – carry electric signal.
Array of red LEDs at 660 nm filter holders (commercial) film polarizer in frame (0 o, 90 o, 10 o ) + circular polarized commercial optical bench, circa.
BPM stripline acquisition in CLEX Sébastien Vilalte.
STATUS ON Optical fiber: Preliminary tests on Optical Fiber and Fiber Optic Feedthrough Massimo Rossella, Marco Prata, Tommaso Cervi INFN, Sezione di Pavia.
BCAL Status Report - HPMT operation - Readout geometry - SciFi tests & analysis - Prototype construction Zisis Papandreou, Regina November 1 st, 2001.
BCAL R&D Rheanne Filby, Blair Jasper, Gergana Koleva, Blaine Langman, Tasha Summers Vitaly Kovaltchouk, George Lolos, Zisis Papandreou GlueX Collaboration.
CTA Calibration Meeting 1 The ASTRI SST-2M Illuminator A.Segreto, G. La Rosa INAF Palermo for the ASTRI Collaboration & the CTA Consortium A. Segreto/G.
Lightel Technologies, Inc.. Background Operation started Jan Based in Seattle, WA Manufacturing in US and China Business: Photonics equipment &
아이알브이테크 1 IRV-TECH 아이알브이테크 May 12, 2015 IRV-65B Light Source.
GS-1150 HANDHELD SPECTROPHOTOMETER. ABOUT GAMMA SCIENTIFIC With over 50 years of experience in developing commercial light measurement instruments, Gamma.
CI-710 Instrument Training Conducted by: Brienne Meyer
DIGITAL DATA 8CH MUX SERIES
Digital Light Sources First introduced in 2001.
Nuclear Chemistry/Solar Neutrino Group
FIBER OPTIC Jumper Cord SERIES
FIBER OPTIC 8Ch Contact Closure Link
From: Measurements of the Temperature Inside an Explosive Fireball
DIGITAL DATA 4CH MUX SERIES
DIGITAL DATA 16CH MUX SERIES
Stand Alone Calibration Station
High Accuracy UV-VIS Spectroradiometer ( nm)
OL 750 Measurement Systems
Design of Apparatus for colour matching.
Diffraction Grating calculation of light wavelength
Palm-Top USB Radiometer/Photometer
OL 750 Spectroradiometer & Linear Spectral Transmission Measurements
Optical fiber based sensors for low temperature and superconductors
Presentation transcript:

Fiber Optic Quality Tests Zisis Papandreou SPARRO Group, Regina Hall D Collaboration Meeting Bloomington, Indiana November 1 st, 2001

Thousands of km… BCAL: a few kilo-km of fibers Quality control along length of spools Method: – Quick, stable, reliable, reproducible – Optical source – Dedicated spectrometer & DAQ – Light transmission, attenuation, timing – Cross-check with ionization source

Ocean Optics Inc. Consulted with Gamble Technologies Issues for the SciFi quality control tests: – Spectrometer(s) – Light source(s) – ADC – Mounts and connectors; reproducibility – Portability – Cost

Spectrometer Option A USB-2000 – Plug and play – Single channel – Small footprint – Accessories Gratings, filters, slits – No power source – OOIBase32 (free) – calibration coeff.

Spectrometer Option B SD-1000 – Dual channel – Small footprint – Accessories Gratings, filters, slits – No power source – 2048 CCD array – Uses ADC1000USB

Light Source LS450 – Stand alone or USB – White LED – nm

Accesories #3 Grating – nm Order sorting filter – OFLV Slit – 50  m Mount – Dremel chuck holder – Custom made Connectors – SMA 905 ADC

Regina: Option B Spectrometer: SD1000 configured Light source: LS-450 with suitable LED’s Bifurcated fiber Two P200-US/VIS fibers (to SD and LS) SMA connectors and mounts OOIBase32 software (free) Reproducible, stable, bulky, assembly line tests

Option A Spectrometer: USB1000 Light source: LS-450 with suitable LED’s Two P200-US/VIS fibers (to SD and LS) SMA connectors and mounts OOIBase32 software (free) Reproducible ??, stable, portable, geared for smaller number of fibers

Option B Cost SD-1000 Spectrometer (plus accessories) US$3,600 LS-450 Light SourceUS$600 ADC-1000-USBUS$600 LaptopUS$1,700 TotalUS$6,500