ANL, MAR-2014Ivo Polák, FZU, Prague1 Activity on Compass 2 detector with Calibration at Prague Ivo Polák, on behalf of Prague’s group Compass.

Slides:



Advertisements
Similar presentations
HH Dec 13Ivo Polák, FZU, Prague1 LED notched fibre distributing system QMB1 single LED slice Ivo Polák, on behalf prague’s group 1.QMB1.
Advertisements

Optical Fiber Calibration System and Adaptive Power Supply Jiri Kvasnicka, Ivo Polak, Jaroslav Cvach Prague, Institute of Physics Gerald Eigen,
Study of the MPPC Performance - contents - Introduction Fundamental properties microscopic laser scan –check variation within a sensor Summary and plans.
CMS ECAL Laser Monitoring System Toyoko J. Orimoto, California Institute of Technology, on behalf of the CMS ECAL Group High-resolution, high-granularity.
LCWS2010, Beijing, 2010 MAR29 Ivo Polák, FZU, Prague1 LED notched fibre system at AHCAL Calibration system for SiPM Ivo Polák 1.Notched fibre.
Calice, UT ArlingtonJiri Kvasnicka, FZU, Prague1 LED notched fiber system Jiri Kvasnicka 1.Introduction 2.Test setup and fiber layout on HBU0.
Ivo Polák SiPM needs short optical pulses
LED calibration systems for CALICE hadron calorimeter Jiri Kvasnicka, Ivo Polak Institute of Physics (FZU), Prague June 11, 2011TIPP 2011, Kvasnicka1 The.
ECFA, JUN10, 2008Ivo Polak, IPASCR, Prague1 Electronics part of AHCAL calibration system ECFA meeting at Warszawa.
ECAL electronics Guido Haefeli, Lausanne PEBS meeting 10.Jan
EUDET, OCT8 - 10, 2007 Ivo Polak, IoP Prague1 A fast LED driver prototype for HCAL calibration EUDET annual meeting at Ecole Polytechnique, Palaisau.
The PSD upgrade performance Front-End-Electronics MAPD HV system Temperature stabilization MAPD gain monitoring system Slow control Readout –present and.
External calibration system - QMB6 Distribution of light: Notched Fiber Calibration and Monitoring Board (CMB) 1-ch LED driver (QMB1) Calibration System.
DESY, DEC-2013Ivo Polák, FZU, Prague1 Activity on Adaptive power & Calibration at Prague Ivo Polák, on behalf of Prague’s group QMB1A update.
N. Anfimov (JINR) on behalf of the ECAL0 team.  Introduction  Installation and commissioning  Calibration  Data taking  Preliminary result  Plans.
Feb 20, 2009 CALICE meeting, Daegu, Korea QRL in Magnetic Field 1 QRLed Driver in Magnetic Field Jaroslav Zalesak Institute of Physics of the ASCR, Prague.
Optical calibration system for EUDET AHCAL module Jaroslav Cvach IPASCR 1.Calibration system for SiPM photodetectors 2.QRLED driver photoelectron spectra.
LED calibration systems for CALICE hadron calorimeter Jiri Kvasnicka Institute of Physics, Prague June 11, 2011TIPP 2011, Chicago1 Under.
LED calibration systems for CALICE hadron calorimeter
CALICE Meeting DESY ITEP&MEPhI status report on tile production and R&D activities Michael Danilov ITEP.
HCAL1 Status 2003 Oleg Gavrishchuk, JINR, Dubna 1. HCAL1 performance 2003 General design High Voltage system LED monitoring 2. Tests in muon halo beam.
Evaluation of Silicon Photomultiplier Arrays for the GlueX Barrel Calorimeter Carl Zorn Radiation Detector & Medical Imaging Group Jefferson Laboratory,
2013 MAR 21Ivo Polák FZU Prague1 Tasks for AIDA SiPM Adaptive HV PSU AIDA subgroup Prague 2013 meeting Characterization of temperature influence to SiPM.
PSD upgrade: Ar-present and Xe-future 1.- Status of the PSD upgrade 2.- PSD performance after upgrade 3.- Problems during the Ar-run 4.- Future scenarios.
Status of Projectile Spectator Detector A.Kurepin (Institute for Nuclear Research, Moscow) I. Introduction to PSD. II. Conception and design. III. Development.
Calibration UV LED system for CALICE scintillator based Tile Hadron Calorimeter Ivo Polák on behalf of the CALICE Collaboration Institute of Physics of.
The MPPC Study for the GLD Calorimeter Readout Introduction Measurement of basic characteristics –Gain, Noise Rate, Cross-talk Measurement of uniformity.
LCWA, ALCPG 2009 Albuquerque, NM Ivo Polák, FZU, Prague1 Calibration system of CALICE AHCAL detector Ivo Polák 1.Two calibration light distribution.
CALICE ANL, MAR18, 2008 Ivo Polak, IPASCR, Prague1 A fast LED driver prototype for HCAL calibration CALICE meeting at ANL, USA.
Light Calibration System (LCS) Temperature & Voltage Dependence Option 2: Optical system Option 2: LED driver Calibration of the Hadronic Calorimeter Prototype.
Munich, 18 Oct 2006J. Cvach, annual JRA31 JRA3 Institute of Physics ASCR Prague 1.ECAL, VFCAL (V. Vrba) 2.HCAL (J. Cvach) 3.Exchange in NA2 (travels 8.5.
1. DESY tests 2. Electronics developments 3. Optical developments 4. Outlook Casablanca J. Cvach, CALICE Coll. meeting.
1 Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH.
May - 20Ivo Polák, FZU, Prague1 LED notched fibre distributing system Calibration system for SiPM Ivo Polák, on behalf prague’s group
5 July 2010Ivo Polák, FZU, Prague LED notched fibre distributing system Calibration system for SiPM Ivo Polák, Ji ř í Kvasni č ka
PSD upgrade: concept and plans - Why the PSD upgrade is necessary? - Concept and status of the PSD temperature control - Concept of the PSD analog part.
oct - 6Ivo Polák, FZU, Prague1 Calibration system for SiPM and LED notched fibre distributing system Ivo Polák, on behalf prague’s group
E.Guschin (INR,Moscow) 3 May 2006Calorimeter commissioning meeting Status of PRS/SPD detector Cosmic test results Installation/tuning of monitoring system.
LED calibration systems for CALICE hadron calorimeter Jiri Kvasnicka, Ivo Polak, Institute of Physics, Prague June 11, 2011TIPP 2011, Kvasnicka1 The CALICE.
FSC Status and Plans Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA Russia workshop, ITEP 27 April 2010.
Main HCAL, JUL1,2008Ivo Polak, IP_ASCR, Prague1 Calibration system with optical fibers HCAL main meeting, DESY.
Status of the PSD upgrade - Problems with PSD in Be runs - Modification of cooling system - New temperature control - Upgrade of HV control system - MAPD.
2007 detectors study at CERN 1.SiPM time resolution 2.MAPD S60 3.Blue sensitive MAPD 4.New 16ch board 5.New HV.
A.Olchevski, JINR (Dubna) Test Beam studiesof COMPASS ECAL0 Test Beam studies of COMPASS ECAL0 module prototype with MAPD readout ECAL0 Team, JINR, DUBNA.
The 2 nd SCECAL module for the Fermilab beam test - tentative idea - S. Uozumi (Shinshu) Jun GLDCAL meeting Next beam test will be held likely.
Performance of new MPPC Nov. 21 Korea-Japan joint meeting Takashi Maeda Hideki Yamazaki Yuji Sudo (University of Tsukuba) --- Contents ---
Status of the PSD upgrade - Status of the PSD cooling and temperature stabilization system - MAPD gain monitoring system - PSD readout upgrade F.Guber,
PSD upgrade: concept and plans - Why the PSD upgrade is necessary? - Concept of the PSD temperature stabilization and control - Upgrade of HV control system.
ShinShu, 2012 Mar 6Ivo Polák, FZU, Prague1 LED notched fibre distributing system QMB1 with HBU2 test Ivo Polák, on behalf of Prague’s group
2011 Sept 14-16Ivo Polák, FZU, Prague1 LED notched fibre distributing system QMB1 single LED slice Ivo Polák, on behalf prague’s group 1.QMB1.
1 Advanced designs of avalanche micro-pixel photodiodes (MAPD) from Zecotek Photonics Ziraddin (Zair) Sadygov On behalf of “MAPD collaboration” (JINR -
Annual EUDET, OCT6,2008 Ivo Polak, IP_ASCR, Prague1 Calibration system with optical fibers for AHCAL EUDET annual meeting, NIKHEF 1.Introduction 2.QRLed.
HCAL1 Status 2004 Oleg Gavrishchuk, JINR, Dubna 1. HCAL1 performance in 2004 General design High Voltage system LED monitoring 2. Stability in 2003 Led.
Status of NEWCHOD E.Guschin (INR), S.Kholodenko (IHEP), Yu.Kudenko (INR), I.Mannelli (Pisa), O.Mineev (INR), V.Obraztsov (IHEP), V.Semenov(IHEP), V.Sugonyaev.
DESY, 8 Dec 2005J. Cvach, prekick-off JRA3 JRA3 Institute of Physics ASCR Prague 1.ECAL, VFCAL (V. Vrba) 2.HCAL (J. Cvach) 3.Exchange in NA2 (travels 8.5.
1 Projectile Spectator Detector: Status and Plans A.Ivashkin (INR, Moscow) PSD performance in Be run. Problems and drawbacks. Future steps.
February 10, 2009, G-APD Workshop, GSI Darmstadt1 APD Laser Test Setup Charles University, Faculty of Mathematics and Physics, Institute of Particle and.
N. Anfimov a, V. Anosov a, I. Chirikov-Zorin a, D. Fedoseev a, O. Gavrishchuk a, N. Khovanskiy a, Z. Krumshtein a, R. Leitner b, G. Meshcheryakov a, A.Nagaytsev.
The design of a photodetector unit of a new Shashlyk EM
LED notched fibre distributing system Calibration system for SiPM
JRA3 Institute of Physics ASCR Prague
Plans for this week MWPC: wire stretching today
LED notched fibre system short HBU0 party with QMB6
Scintillation Detectors in High Energy Physics
Frontier Detectors for Frontier Physics
LED notched fibre system at AHCAL Calibration system for SiPM
A fast LED driver prototype for HCAL calibration
T2Kロシアグループに向けたMPPC(SiPM)の性能評価
The MPPC Study for the GLD Calorimeter Readout
New electromagnetic calorimeter for GPD measurements at COMPASS
Presentation transcript:

ANL, MAR-2014Ivo Polák, FZU, Prague1 Activity on Compass 2 detector with Calibration at Prague Ivo Polák, on behalf of Prague’s group Compass detector Prague contribution to ECAL0 60 Fibres in bundle Modification of QMB1 with PIN PD feedback Plans COmmon Muon Proton Apparatus for Structure and Spectroscopy

ANL, MAR-2014Ivo Polák, FZU, Prague2 12 countries participate on Compass 3 institutions at ECAL0 subdetector our institute (FZU) been invited to collaborate on calibration on ECAL0 Joint Institute for Nuclear Research, Dubna, Russia Faculty of Mathematics and Physics of Charles University, Prague, Czech Republic Institute for Scintillation Materials NAS of Ukraine Representatives: I. Savin, Z. Krumstein, A. Nagaytsev R. Leitner P. Zhmurin ECAL0

ANL, MAR-2014Ivo Polák, FZU, Prague3 ECAL0 module for Compass 2 The new-generation high-granularity Shashlyk EM calorimeter readout by micropixel avalanche photodiodes (MAPD) with precision thermostabilization based on the Peltier element is designed, constructed end tested. MAPD-3N with superhigh pixel density 1.5×104 mm-2 and area 3×3 mm2 manufactured by the Zecotek Company were used in the photodetector unit.

ANL, MAR-2014Ivo Polák, FZU, Prague4 Shaschlik EM calorimeter prototype with MAPD micropixel avalanche photodiodes 3 rd generation MAPD-3N with the gain 4×10 4 photon detection efficiency (PDE) 25 % in the green region superhigh pixel density 1.5×10 4 mm -2 and area 3×3 mm 2 manufactured by Zecotek Company Peltier element kept the MAPD temperature at 15C within 0.05C

ANL, MAR-2014Ivo Polák, FZU, Prague5 ECAL0 for COMPASS II Module of shashlyk ECAL prototype Readout with very high density MAPD Each module contains 9 MAPD In total 196 MAPDs Modified QMB1 8mm blue LED Long pulses about 30 ns PIN photodiode feedback for higher amplitude stability USB controller, RS232 One LED driver illuminates 60 modules Tunable amplitude Requirements to calibrator: Stable mid range pulses for monitoring Variable amplitude for amplitude scan No interest in Single p.e. spectra (low MAPDs gain) One LED illuminates 50 MAPDs modules Amplitude stability, pulse width 20 to 40ns Fibre distribution system One 8mm blue LED illuminates 60 fibres in bundle. Length of the fibre is 2.5m to reach each MAPD

ANL, MAR-2014Ivo Polák, FZU, Prague6 Modification of QMB1 to ECAL0 One mid of range amplitude monitoring Amplitude scan of MAPDs Extending to 30ns pulse-width, external toroidal inductor On line feedback with PIN PD, to get better long term amplitude stability (LED!) – Amplitude (peak) detector, or fast ADC (?) – Averaging over 100 (10?) pulses Nov 2013 successful test with one module and 8mm LED QMB1 Fibre bundle 8mm LED

ANL, MAR-2014Ivo Polák, FZU, Prague7 60 Fibres in bundle toward to 8mm Blue LED First picture of 60 of 1mm dia fibres illuminated by a daylight. Visible imperfections of some fibres. Picture taken by small cheap USB 1.3Mpx camera microscope. Distribution plot shows abt. 100% spread at 460nm, illuminated by blue 8mm LED.

ANL, MAR-2014Ivo Polák, FZU, Prague8 Status & Plans In Nov 2013 we tested one modified QMB1m (30ns) + 8mm blue LED + fibre bundle with one module of ECAL0 detector. Optical distribution system consists 50 fibres in bundle with SMA connector, in total there will be 4 * 50 = 200 fibres guides light to individual MAPDs. Now under the production. Upgrade of QMB1m pulser to active PIN photodiode feedback QMB1pin boards ready to end of year 2014 Complete HW (QMB1pin + fibrebundles) in 1 st Q of 2015 Compass 2, ECAL0 is going in Octobre 2014 to beamtest at CERN, starts to datataking ~ summer of 2015 installation of all calibrators to the detector ECAL0 at CERN