A Prospective Study Examining Contact Lens Wear, Refractive Error, and Optical Coherence Tomography Retinal Nerve Fiber Layer Measurements Marie Brenner.

Slides:



Advertisements
Similar presentations
OCT= Optical Coherence Tomography
Advertisements

Overnight Corneal Reshaping (Orthokeratology) in Adolescents S. Lance Forstot, MD, FACS The author has no financial interest in the subject matter of this.
A Prospective Trial Evaluating Scleral Rebound Tonometry Sara Duke, MD, Andrew Logeman, Shuchi Patel, MD Loyola University Chicago, Department of Ophthalmology,
Pooja B. Jamnadas, MD, Peter Russo, OD, William Bonk, Shuchi Patel, MD Loyola University Chicago, Stritch School of Medicine, Department of Ophthalmology,
Pooja B. Jamnadas MD, Marie Brenner, MS4, Peter Russo, OD, Shuchi Patel MD Loyola University Medical Center, Department of Ophthalmology, Maywood IL At.
Ruth Lapid-Gortzak MD PhD 1,2, Jan Willem van der Linden BOpt 2, and Ivanka J. van der Meulen MD 1,2 1 Department of Ophthalmology, Academic Medical Center,
Walter Huang, OD Yuanpei University Department of Optometry
Anterior Chamber Depth, Iridocorneal Angle Width, and Intraocular Pressure Changes After Phacoemulsification: Narrow vs Open Iridocorneal Angles Huang.
Statistical Analysis. Purpose of Statistical Analysis Determines whether the results found in an experiment are meaningful. Answers the question: –Does.
The Effect of the Restor Multifocal IOL on Frequency Doubling Perimetry Elizabeth Yeu, MD1, Elizabeth Woznak, BS2, Nicole Kesten, BS2, Steven VL Brown,
Understanding Disparities Among Diagnostic Technologies in Glaucoma De Moraes C, Liebmann JM, Ritch R, Hood DC. Understanding disparities among diagnostic.
Hospitalization rate among chronically ill low vision patients using a home prescription label reader vs. a pill box. Bruce I. Gaynes, OD, PharmD 1,2,
Copyright restrictions may apply JAMA Ophthalmology Journal Club Slides: Retinal Nerve Fiber Layer Loss and Quality of Life in Glaucoma Gracitelli CPB,
Statistical Analysis Statistical Analysis
A Prospective Trial Comparing Scleral Pneumotonometry to Goldmann Applanation Tonometry Sara Duke, MD, Usiwoma Abugo, BS, Shuchi Patel MD Loyola University.
Epidemiology The Basics Only… Adapted with permission from a class presentation developed by Dr. Charles Lynch – University of Iowa, Iowa City.
Nizar S Abdelfattah, M.D.1, Marina Israel2, Nermin Osman, M.D.3,
Guidelines for Appropriate Use of Vitamins, Minerals, and Nutrients for Risk Reduction of Age Related Eye Disease Eric A. Johnson MS2, Bruce Gaynes OD,
G. Jacob 1,2, C. Bouchard 2, S. Kancherla 1. Edward Hines, Jr. VA Hospital, Hines, IL, Department of Ophthalmology 1. Loyola University Medical Center,
Blended vision after bilateral monofocal cataract surgery: an evaluation of spectacle independence and vision related quality of life Allison Landes, MD.
Risk by Richard R. Riker MD Vice-Chair, IRB Maine Medical Center.
Abby El-Shafei Dr. Penny Asbell Ophthalmology Dept. Mount Sinai School of Medicine.
Stratification of Normative Data
Purpose: Introduction:  At initial evaluation: For post-op day # 0 patients: Pre-op VA was 20/50.6 (0.395 ± 0.198); Post-op VA was 20/102.0 (0.196 ± 0.162);
Cataract Surgery After Trabeculectomy: The Effect on Trabeculectomy Function Husain R, Liang S, Foster PJ. Cataract surgery after trabeculectomy: the effect.
Toxic epidermal necrolysis is a life-threatening illness that involves sloughing of 30% or more of the total body surface area. In this spectrum of disease,
Actuator 2 – Provides rotation about the roll direction. Actuator 1 – Provides rotation about the pitch direction Figure 2: The Linear Actuator model Abstract.
Digital Optic Nerve Photography in Assessing Cup-to-Disc Ratio: The Experience in an Academic Institution Naomi Goldberg, Lynda Z. Kleiman, Eric J. Wolf.
P91: Clinical Performance of Phakic Angle-Supported Investigational IOL in Prospective Global Trials, ASCRS 2010, Boston P91: Clinical performance of phakic.
Essential Question:  How do scientists use statistical analyses to draw meaningful conclusions from experimental results?
Evaluation of refractive error measurements obtained by three different aberrometers Radha Ram, BA Li Wang, MD, PhD Mitchell P. Weikert, MD, MS Disclosure:
Khairidzan Mohd Kamal MD
Changes of refractive error during pregnancy Aghadoost Dawood, Mesdaghinia Elaheh Kashan Medical Sciences University, Kashan Trauma Center, Kashan Iran.
OCT in Amblyopia Lionel Kowal.
Mohamed A Guenena, MD Helga P Sandoval, MD, MSCR, Kerry D Solomon, MD Magill research center for vision correction Storm Eye Institute Medical University.
Comparison of Central Corneal Thickness and Peripheral Corneal Thickness using Sheimpflug system, Optical Coherence Tomography and Ultrasound Pachymetry.
Prospective, Randomized, Double-Blind Study Comparing Nepafenac 0.1% (Nevanac™) and Bromfenac Sodium 0.09% (Xibrom™) in Post-Op Cataract Patients Hon-Vu.
The Effect of Corneal Anterior Surface Eccentricity on Astigmatism after Cataract Surgery Choul Yong Park MD 1 Sung Jun Lee MD 1 Prabjot Channa MD 2 Roy.
A Prospective Trial Comparing Pneumotonometry of Cornea and Sclera Usiwoma Abugo BS 1, Sara Duke MD 2, Shuchi Patel, MD 2 1 Loyola University Chicago,
*Kagithane State Hospital,Department of Ophthalmology,Istanbul, Turkey DR.GÖKHAN KAYA *Kagithane State Hospital,Department of Ophthalmology, No author.
Deep Anterior Lamellar Keratoplasty (DALK) Vs Penetrating Keratoplasty (PK) in patients with Keratoconus (KC). Dr. K.S.SIDDHARTHAN Aravind Eye Hospital.
Familial corneal patterns in pellucid marginal degeneration: uncovering a possible etiology Hajirah N. Saeed, M.D., Amy B. Rosenfeld Ph.D., Xiaowu Gai,
Comparison of Central Corneal Thickness, Anterior Chamber Depth, and Central Corneal Power Measurements between Two Scheimpflug Imaging Systems Yuichi.
Hongseok Yang, M.D. Dae Hee Kim, M.D. Department of Ophthalmology, Ajou University School of medicine, Suwon, Korea The authors have no financial interest.
Minimizing Risk in Visian ICL Implantation.
Lifestyle and Refractive Factors Affecting Progressive Addition Lens Preference Padmapriya Ramamoorthy 1, James E Sheedy 2 and John Hayes 2 1 The Ohio.
Lifestyle and Refractive Factors Associated with Progressive Addition Lens Preference The Center for Ophthalmic Optics Research, The Ohio State University.
Laser in Situ Keratomileusis Decentration With and Without Active Eye-Tracking System Mark Edmund Johnston MD FRCSC P 167: The author.
Date of download: 6/30/2016 Copyright © 2016 American Medical Association. All rights reserved. From: Fourier Analysis of Optical Coherence Tomography.
OCT characteristics in Idiopahthic Intracranial Hypertension Michael Waisbourd, MD Igal Leibovitch, MD Dafna Goldenberg, MD Anat Kesler, MD Department.
1. Ankara University School of Medicine, Department of Ophthalmology
and Microperimetry visual field parameters for Glaucomatous Loss
Iwona Helemejko, MD 1; D. Robert Iskander, PhD2
Reproducibility of retinal thickness measurements in eyes with
Suppressive effect of combined treatment of orthokeratology and 0
Characteristics of Primary Angle-Closure Glaucoma Patients with Normal Intraocular Pressure at the First Visit Won Hyuk Oh1, Bum Gi Kim1, Joo Hwa Lee2.
Safety of medication reduction for Primary Angle Closure (PAC) –
Mumbaieyecarecornealasik.com.
P-WT-294 Comparison of red-free photography, swept-source OCT and spectral-domain OCT for evaluation of retinal nerve fiber layer defects. Gilda WK Lai,
Asymmetry Analysis of Retinal Thickness
Nabil El Ayoubi MD, Helen Sawaya, MSc., Raja Sawaya MD.
17100 Contact lens fitting after corneal CXL
Structure-Function Relationship Between the Bruch Membrane Opening-based Minimum Rim Width and Visual Field Defects in Advanced Glaucoma Serhat Imamoglu,
From: Relationship Between Optic Nerve Appearance and Retinal Nerve Fiber Layer Thickness as Explored with Spectral Domain Optical Coherence Tomography.
From: Effect of Cataract Surgery on Optical Coherence Tomography Measurements and Repeatability in Patients With Non-Insulin–Dependent Diabetes Mellitus.
Volume 122, Issue 7, Pages (July 2015)
Maayan E. Keshet, M.D. Maggie B. Hymowitz, M.D. John J. Kim, M.D.
Vicente J. Correa-Gomez MD, Guillermo Tapia MD, Oscar Macias Manuel MD, Alejandro Navas Perez MD, Gilberto Islas MD, Tito Ramírez-Luquin MD, Enrique O.
JAMA Ophthalmology Journal Club Slides: Association of Maternal Smoking and Birth Weight With Later RNFL Thickness Ashina H, Li XQ, Olsen EM, Skovgaard.
Lasik decentration with the VISX ActiveTrak™ System
Presentation transcript:

A Prospective Study Examining Contact Lens Wear, Refractive Error, and Optical Coherence Tomography Retinal Nerve Fiber Layer Measurements Marie Brenner MS4, Pooja B Jamnadas MD, Peter Russo OD, Shuchi Patel MD Loyola University Medical Center, Department of Ophthalmology, Maywood IL References Introduction Conclusions Retinal nerve fiber layer (RNFL) measurements are often used to aid ophthalmologists in the diagnosis and management of glaucoma. One of the challenges in measuring retinal nerve fiber layer thickness is obtaining good quality scans with accurate measurements. Our study serves to report the effects of contact lenses wear on RNFL measurements. Furthermore, we sought to determine if the degree of refractive error impacts RNFL measurements or Q values with contact lens wear. We studied patients with both soft and rigid gas permeable lenses. At lower refractive errors, better quality studies are obtained without contact lenses in place Higher refractive errors which are corrected with contact lenses may lead to improved quality Distortion due to the contact lenses may be negated when refractive error exceeds diopters Further studies are needed with larger cohorts in order to create an appropriately powered trial which can provide conclusive information Ongoing data collection and statistical analysis pending 1. Budenz DL, Change RT, Huang X, Knighton RW, Tielsh JM. Reproducibility of Retinal Nerve Fiber Thickness Measurements Using the Status OCT in Normal and Glaucomatous Eyes. Investigative Ophthalmology & Visual Schience. 2005; 46(7): Fujimoto JG. Optical coherence tomography for ultrahigh resolution in vivoimaging. Nature Biotechnology. 2003; 21(11): Youm DJ, Kim JM, Park KH, Choi CY. The Effect of Soft Contact Lenses During the Measurement of Retinal Nerve Fiber Layer Thickness Using Optical Coherence Tomography. Current Eye Research 2009; 34: Abstract Purpose: The purpose of this study is to determine if statistically significant differences exist between retinal nerve fiber layer (RNFL) measurements and quality (measured in Q value) of optical coherence tomography (OCT) in patients with and without contact lenses. We also aimed to determine if higher refractive errors made a larger effect on the RNFL and Q value measurements. We examined soft and rigid gas permeable lenses. Methods: After obtaining IRB approval and consent, patients in the Loyola eye clinic had their RNFL measured with and without contact lenses using the Spectralis OCT (Heidelberg Engineering USA). The patient's refractive error, RNFL, and Q value were recorded. A paired t test was used comparing the average RNFL and Q value with and without contact lenses. A subgroup analysis was done looking at patients with refractive errors lower than -5.0 diopters, and equal to or above -5.0 diopters. For patients with astigmatism, the spherical equivalence was used. Subgroup analysis was also done comparing RGP lenses and soft contact lenses. Results: No statistically significant difference is present in RNFL measurments and OCT quality with or without contact lens wear overall. Subgroup analysis found no statistically significant difference in RNFL. The difference in Q value was not significant in subjects with higher refractive errors. Patients with a lower refractive error with soft contact lenses had significantly better quality studies without contact lenses. Patients with RGP lenses had significantly better quality studies without contact lenses. Gross examination of the study images does show more clear images in patients with higher refractive errors when contacts are in. Although not significant, average Q values are higher in patients with contact lenses with refractive errors above Conclusions: We conclude that at lower refractive errors, better quality studies are obtained without contact lenses. However, we hypothesize that with higher refractive errors, correcting refractive error with contact lenses provides an improved quality which begins to negate the distortion caused by the contact lens itself. Therefore, additional studies that include more patients with higher refractive errors are needed to see if a larger n will allow for results to reach statistical significance. Acknowledgements: The Illinois Society for the Prevention of Blindness The Richard A. Perritt Charitable Foundation Methods IRB approved, prospective case control study 9 patients presented to the Loyola eye clinic for routine examination Patients were provided appropriate informed consent and were aware of the risks and benefits of participation Patients underwent Spectralis OCT (Heidelberg Engineering USA) testing with and without their daily contact lenses in place We studied refractive error, RNFL, Q value with and without contact lenses in place Subgroup analysis was conducted with chi square analysis analyzing whether degree of refractive error impacted pertinent variables Patients with astigmatism were included using spherical equivalence Subgroup analysis was also performed on whether rigid gas permeable or soft contact lenses had an impact on pertinent variables Gross Examination: Better Image Quality with Contact Lens Results Contact LensNo Contact Lenses Patients with a lower refractive error had significantly better quality studies without contact lenses. Patients with rigid gas permeable lenses had better quality studies without contact lenses. Although not significant, average Q values are higher in patients with contact lenses with refractive errors above