DOPPLER ULTRASOUND in Pregnancy Dr. Mohammed Abdalla Egypt, Domiat Hospital.

Slides:



Advertisements
Similar presentations
Management of AREDV masihi 29/11/92
Advertisements

Chapter 19 – Vascular System
Middle Cerebral Artery Doppler
Farhan Hanif,MD Maternal Fetal Medicine
Fetal Wellbeing and Antenatal Monitoring
Ant-partum Fetal Evaluation
Doppler Ultrasonography in Obstetrical Practice
USS tests of fetal wellbeing
Christopher R. Graber, MD Salina Women’s Clinic 10 Oct 2011.
IUGR fetuses IUGR fetuses Erich Cosmi MD Department of Gynecological Science and Human Reproduction Section of Maternal and Fetal Medicine University of.
إعداد : أ. بلسم فهد صوفي 1 Ultrasound in Medicine Ch.3 Ultrasound pictures of the body.
Bhide A, Acharya G, Bilardo CM, Brezinka C, Cafici D, Hernandez- Andrade E, Kalache K, Kingdom J, Kiserud T, Lee W, Lees C, Leung KY, Malinger G, Mari.
إعداد : أ. بلسم فهد صوفي،،،المصدر:محاضرات د.حنان 1 Ultrasound in Medicine Ch.4 Ultrasound pictures of the body.
IUGR, AFI, and Aneuploidy
بسم الله الّرحمن الّرحیم. Definition: fetus uniforfmly small for gestational age Etiologies of symmetric IUGR: Genetic disorders( e.x: trisomy 18,13,10.
Management of SGA with 2SD increased UA PI and standard measurement
INTRAUTERINE GROWTH RESTRICTION Max Brinsmead MB BS PhD August 2014.
DOPPLER SONOGRAPHY By Dr/ Dina Metwaly.
TRANS CRANIAL DOPPLER.
Why umblical artery doppler
ANTEPARTUM FETAL SURVILLANCE
Dr. Saeed Mahmoud MRCOG,MRCPI,MIOG,MBSSCP Assistant professor & consultant Obstetric & gynecology department Collage of medicine King Saud University.
Fetal Monitoring Ultrasonography Monitoring: Chorionic sac during embryonic period placental and fetal size multiple births abnormal presentations biparietal.
Presented by: Dr. Farzad Afzali Kasra medical imaging center.
Fetal Dopplers- A Review
ASSESSMENT OF FETAL WELLBEING Max Brinsmead MB BS PhD May 2015.
FETAL MONITORING REASONS TO MONITOR THE FETUS ANTENATAL: 1. MATERNAL INDICATIONS e.g. obstetric cholestasis 2. FETAL INDICATIONS e.g. reduced fetal movements,
Medical terms used in ultrasonography
A Comparison of Discriminant Functions and Decision Tree Induction Techniques for Evaluation of Antenatal Fetal Risk Assessment Nilgün Güler, Olcay Taner.
PRENATAL DIAGNOSIS OF A LARGE PLACENTAL CYST WITH INTRACYSTIC HEMORRHAGE OB8.
Amirkabir imaging center dr.m.ali mohammadi 2011.
Resident Categorical Course
Premature Delivery Premature Rupture of Membrane Prolonged Pregnancy, Multiple Pregnancy Women Hospital, School of Medical, ZheJiang University Yang Xiao.
Dr. Anjoo Agarwal Professor Dept of Obs & gyn KGMU, Lucknow
Display of Motion & Doppler Ultrasound
Follow-up scans later in pregnancy improved accreta detection but provided useful information in only a limited number of cases. Of the individual markers,
Doppler Ultrasound Dr Mohamed El Safwany, MD.. Introduction The Doppler Effect refers to the change in frequency that results when either the detector/observer.
PWV & PWA Parameter Extraction / Transfer Function.
UOG Journal Club: October 2011 Pulsed-wave tissue Doppler echocardiography for the analysis of fetal cardiac arrhythmias B. Tutschek and K. G. Schmidt.
TEMPLATE DESIGN © Umbilical artery Pulsatility Index and different reference ranges: Does it really matter? Lo W., Mustafa.
Saudi Board of Radiology: Physics Refresher Course Kostas Chantziantoniou, MSc 2, DABR Head, Imaging Physics Section King Faisal Specialist Hospital &
In the name of god.
Fetal assessment.
Fetal death in pregnant diabetic women B-Khani Assistant professor of Isfahan University of Medical Science.
Chapter 11: Circulations and Blood Vessels
Fetal Wellbeing Dr Hsu Chong NIHR Clinical Lecturer in Obstetrics & Gynaecology Warwick Medical School.
DOPPLER ULTRASOUND IN ASSESSMENT OFFETAL WELLBEING
Definition & Risk Factors of FGR FGR, also called IUGR is the term used to describe a fetus that has not reached its growth potential because of genetic.
Late onset IUGR managment S-Borna.MD, Perinatolgy Dep, Vali-e-Asr hospital,TUMS.
Anatomic Physiologic features cardiovascular system in infants and children. associate professor Kantemirova M.G.
Date of download: 6/3/2016 Copyright © The American College of Cardiology. All rights reserved. From: Pregnancy in Patients With Pre-Existing Cardiomyopathies.
DR NOORZADEH fellowship of perinatology Shariati hospital
In the Name of God. All women should be assessed at booking for risk factors for a SGA fetus/neonate to identify those who require increased surveillance.
Antenatal Assessment of Fetal Well-being
Middle cerebral artery peak systolic velocity: a new Doppler parameter in the assessment of growth-restricted fetus G.MARI, F HANIF, M KRUGER, et. al,.
Date of download: 7/6/2016 Copyright © The American College of Cardiology. All rights reserved. From: Manifestations of Cardiac Disease in Carotid Duplex.
Fetal Cardiac function
Doppler Evaluation in Obstetrics
Heart & Thalassemia . R.Miri,MD, Interventional Cardiologist.
Fetal cerebral blood flow and volume
Ultrasound evaluation of the RENAL ARTERIES and the kidney
“How To” record uterine artery Doppler at 11–13 weeks
Doppler Evaluation in Obstetrics
Fetal Assessment Assistant Professor, Consultant
UOG Journal Club: July 2012 Maternal hemodynamics at 11–13 weeks’ gestation and risk of pre-eclampsia A. Khalil, R. Akolekar, A. Syngelaki, M. Elkhouli.
UOG Journal Club: October 2018
Finn Lauszus, Hanne Søndergaard, Carsten Byrialsen, Ervin Kallfa
To Doppler or not to Doppler
SUMMARY OF DOPPLER PARAMETERS
Surabhi Madhwal et al. JIMG 2014;7:
Presentation transcript:

DOPPLER ULTRASOUND in Pregnancy Dr. Mohammed Abdalla Egypt, Domiat Hospital

First use of Doppler ultrasonography to study flow velocity in the fetal umbilical artery was reported in 1977 Doppler History

Fitzgerald & Drumm. Umbilical artery studies 1977BMJ Eik-Nes et al. Fetal aortic velocimetry : Dupplexscanner 1980 Lancet Campbell et al. Utero-placental circulation: Dupplex scanner 1983 Lancet Wladimiroff et al. MCA / UA PI ratio 1987 OG Kiserud et al. Ductus venosus velocimetry 1991Lancet

Basic principals Echoes from stationary tissues are the same from pulse to pulse. Echoes from moving objects exhibit slight differences in the time for the signal to be returned to the receiver. These differences can measured as phase shift from which the Doppler frequency is obtained..

T1 : time of omitted signal. T2 : time of returned signal. T2 – T1 = time difference or phase shift. shift. from phase shift the Doppler frequency is obtained. AS TIME DIFFERENCE DECREASE THE DOPPLER FREQUENCY INCREASE.

pulse repetition frequency phase shift (T2 –T1) phase shift with known beam / flow angle can calculate flow velocity. T1 T2

The time difference or phase shift are then proceeded to produce either colorflow display or a Doppler sonogram Basic Principals

 ‘Doppler frequency’ is obtained by measuring the time difference for the signal to be returned when reflected from moving scatterers.  Doppler frequency increase if: 1. flow velocity increased. 2. beam is more aligned to the direction of flow. flow. 3. higher transducer frequency is used.

(the angle q between the beam and the direction of flow becomes smaller). This is of the utmost importance in the use of Doppler ultrasound. Freq. q The angle of insonation Flow velocity Factors affecting doppler frequency

(the angle q between the beam and the direction of flow becomes smaller). This is of the utmost importance in the use of Doppler ultrasound. beam(A) is more aligned than (B) beam (A) is more aligned than (B) The beam/flow angle at (C) is almost 90° and there is a very poor Doppler signal The flow at (D) is away from the beam and there is a negative signal.

Aliasing If a second pulse is sent before the first is received, the receiver cannot discriminate between the reflected signal from both pulses and aliasing occur.

So to eliminate aliasing The pulse repetition frequency or scale is set appropriately for the flow velocities Aliasing

The volume flow in the UAs increases with advancing gestation. The high vascular impedance detected in the first trimester gradually decreases. It is attributed to growth of placental unit and increase in the number of the functioning vascular channels. Basic Principals

Uses plays a vital role in the diagnosis of fetal cardiac defects. assessment of the hemodynamic responses to fetal hypoxia and anemia. diagnosis of other non-cardiac malformations.

Blood supply provided by the ovarian and uterine arteries Uterine Arteries: main branches of the internal iliac arteries Uterine Arteries: Ascend through the lateral wall and anastomose with the ovarian arteries Blood supply provided by the ovarian and uterine arteries Uterine Arteries: main branches of the internal iliac arteries Uterine Arteries: Ascend through the lateral wall and anastomose with the ovarian arteries AnatomyAnatomy

n Spiral Arteries: connect the maternal circulation to the endometrium n Responsible for a 10 fold increase in blood flow n Spiral Arteries: connect the maternal circulation to the endometrium n Responsible for a 10 fold increase in blood flow AnatomyAnatomy n Arcuate Arteries: Run Circumferentially around the uterus n Uterus: Blood supply to anterior and posterior walls provided by the Arcuate arteries n Radial Arteries: Extend from the arcuate arteries and enter the endometrium n Arcuate Arteries: Run Circumferentially around the uterus n Uterus: Blood supply to anterior and posterior walls provided by the Arcuate arteries n Radial Arteries: Extend from the arcuate arteries and enter the endometrium

n Conversion of small muscular spiral arteries into large vascular channels transforms the uteroplacental circulation into a low-resistance-to-flow system. These have a dilated and tortuous lumen, a complete absence of muscular and elastic tissue, no continuous endothelial lining. AnatomyAnatomy

Umbilical artery doppler

Doppler indices

UMBILICAL ARTERY FLOW characteristic saw-tooth appearance of arterial flow in one direction and continuous umbilical venous blood flow in the other. Umbilical artery

FACTORS AFFECTING UMBILICAL ARTERY DOPPLER FLOW VELOCITY WAVEFORMS*

Benefit of Umbilical Artery Evaluation Less experienced operators can achieve highly reproducible results with simple, inexpensive continuous-wave equipment. Umbilical artery

The 40% of the combined fetal ventricular output is directed to the placenta by two umbilical arteries. The assessment of umbilical blood flow provides information on blood perfusion of the fetoplacental unit.. Umbilical artery

With advancing gestation, umbilical arterial Doppler waveforms demonstrate a progressive rise in the end-diastolic velocity and a decrease in the pulsatility index. Umbilical artery

Middle cerebral artery doppler

Using color flow imaging, the middle cerebral artery can be seen as a major lateral branch of the circle of Willis, running anterolaterally at the borderline between the anterior and the middle cerebral fossae The possible Doppler velocimetry sites Middle cerebral artery

The blood velocity increases with advancing gestation, and this increase is significantly associated with the decrease in PI

An early stage in fetal adaptation to hypoxemia - central redistribution of blood flow ( brain-sparing reflex) ( brain-sparing reflex) increased blood flow to protect the brain, heart, and adrenals reduced flow to the peripheral and placental circulations Middle cerebral artery

Doppler wave form of early stage of fetal hypoxemia Doppler wave form of early stage of fetal hypoxemia increased end-diastolic flow in the middle cerebral artery (lower MCA pulsatility index or resistance index) Average of both MCAs must be calculated for more precise result Average of both MCAs must be calculated for more precise result

Middle Cerebral Artery Flow velocity waveform in the fetal middle cerebral artery in a severely anemic fetus at 22 weeks (left) and in a normal fetus (right). In fetal anemia, blood velocity is increased

When the fetus is hypoxic, the cerebra arteries tend to become dilated in order to preserve the blood flow to the brain and The systolic to diastolic (A/B) ratio will decrease (due to an increase in diastolic flow) Middle Cerebral Artery

Doppler ultrasound for the fetal assessment in high-risk pregnancies (Cochrane Review). In: The Cochrane Library, Neilson JP and Alfirevic Z  Trudinger et al 1987  McParland et al 1988  Tyrrell et al 1990  Hofmeyr et al 1991  Newham et al 1991  Burke et al Studies Included In Analysis Almstrom et al 1992 Biljan et al 1992 Johnstone et al 1993 Pattison et al 1994 Nienhuis et al 1997

Doppler ultrasound for the fetal assessment in high-risk pregnancies Nearly 7000 patients were included The trials compared no Doppler ultrasound to Doppler ultrasound in high-risk pregnancy (hypertension or presumed impaired fetal growth) Meta analysis

Doppler ultrasound for the fetal assessment in high-risk pregnancies A reduction in perinatal deaths. A reduction in perinatal deaths. Fewer inductions of labour. Fewer inductions of labour. Fewer admissions to hospital. Fewer admissions to hospital. no report of adverse effects. no report of adverse effects. No difference was found for fetal distress in labour. No difference was found for fetal distress in labour. No difference in caesarean delivery. No difference in caesarean delivery. Main results

Biophysical profile for fetal assessment in high risk pregnancies When compared with conventional fetal monitoring (usually cardiotocography) biophysical profile testing showed no obvious effect (either beneficial or deleterious) on pregnancy outcome. There was an increase in the number of inductions of labour following biophysical profile in the trial. When compared with conventional fetal monitoring (usually cardiotocography) biophysical profile testing showed no obvious effect (either beneficial or deleterious) on pregnancy outcome. There was an increase in the number of inductions of labour following biophysical profile in the trial. Alfirevic Z, Neilson JP. Biophysical profile for fetal assessment in high risk pregnancies (CochraneReview). In: The Cochrane Library, 1995.