GF v03 Aug 2000 1 Gel Filtration. GF v03 Aug 2000 2 Gel filtration What is gel filtration and why use it? Some typical results Why and when to choose.

Slides:



Advertisements
Similar presentations
Gel Filtration Gel permeation chromatography Size exclusion chromatography Separation of molecules on the basis of size (and shape)
Advertisements

Introduction to Chromatography
Sample clean-up (MALDI)
BIOCHEMISTRY EXPERIMENT PProfessor: Sheng Zhao ( 赵晟 ) WWeb for lecture slides : E /QQ /MSN/gchat:
Size Exclusion Chromatography
Foundation GPC Training Course Theory. Nomenclature Gel Permeation ChromatographyGPC Size Exclusion ChromatographySEC Gel Filtration ChromatographyGFC.
Protein Purification Molecular weight Charge Solubility Affinity.
1 HPLC Lecture Mobile Phase Selection in Partition Chromatography Optimization of the mobile phase composition and polarity is vital for obtaining.
Separation of molecules and determination of there molecular weight by gel filtration chromatography. Experiment 7 BCH 333.
Chromatography for Protein purification 1
BISC 220 Lab 2 Protein Purification by Affinity Chromatography & Determination of Specific Activity.
Figure 1. Influence of sample solvent on peak shape. The sample is dissolved in buffer with (a) 0%, (b) 30%, (c) 50%, and (d) 70% acetonitrile. Sample.
Chem. 133 – 5/5 Lecture. Announcements Lab Report 2.4 due Thursday – can turn in today for reduction of late penalties Term Project Progress Report –
1. 2  A form of “partition chromatography”.  Stationary phase is a porous gelatinous matrix (in the form of beads).  Sample components enter pores.
Gel filtration Chromatography
Column Chromatography. Types of columns: 1- Gravity Columns: The mobile phase move through the stationary phase by gravity force. 2- Flash Columns (Air.
Salting out is a method of separating proteins based on the principle that proteins are less soluble at high salt concentrations. The salt concentration.
Protein Purification and Analysis Solubility of proteins important for purification: 60-80% soluble, 20-40% membrane Size of proteins varies Some proteins.
Gel Filtration Chromatography.
Ion Exchange Chromatography. Cation exchangers They contain immobilized anionic groups that bind to cations. e.g. a matrix with carboxymethyl group(CM)
In the name of god.
Chromatography Desalting and Affinity. Chromatography Technique to separate components of a mixture by passing them through a matrix. –A solvent is used.
Principles of Chromatography. Chromatography is the most powerful tool for separating & measuring the components of a complex mixture. Quantitative &
Chemistry 4010 Lab It’s all about PROTEINS… It’s all about PROTEINS…
Gel filtration chromatography y/college/voet/ /animat ed_figures/ch05/f5-6.html.
Chapter 4-1 Chromatography
High Performance Liquid Chromatography
Chromatography Separates components in mixture: Based on - polarity
Chromatographic separations Chapter 26 The “stuff” you do before you analyze a “complex” sample.
Biochemistry February Lecture Analytical & Preparative Protein Chemistry II.
AC part 1 Aug Affinity Chromatography. AC part 1 Aug What is it used for? Monoclonal and polyclonal antibodies Fusion proteins Enzymes DNA-binding.
1.1 General description - Sample dissolved in and transported by a mobile phase - Some components in sample interact more strongly with stationary phase.
LECTURE 9 CHROMATOGRAPHIC SEPARATIONS The “stuff” you do before you analyze a “complex” sample.
Protein Purification and Analysis Solubility of proteins important for purification: 60-80% soluble, 20-40% membrane Size of proteins varies Some proteins.
Factors affecting electrophoresis The electric field ·       Voltage. If the separation of the electrodes is d (cm) and the potential difference.
Proteomics The science of proteomics Applications of proteomics Proteomic methods a. protein purification b. protein sequencing c. mass spectrometry.
Proteins separation and analysis using Fast Protein Liquid Chromatography Ayelet David, Ph.D Dept. of Clinical Pharmacology.
Introduction to Chromatography. Introduction Chromatography permit the scientist to separate closely related components of complex mixtures. In all chromatographic.
Separation techniques ?. Molecules can be separated: Chemically: by charge, by action with specific reagents Physically: by solubility, by molecular weight,
HPLC.
Separation Techniques
Size Exclusion Chromatography *
Size-exclusion Chromatography prof. aza Department of Pharmacy, Andalas University STIFI Perintis, Padang STIFAR, Pekan Baru STIFI Bhakti Pertiwi, Palembang.
Protein Purification for Crystallization Dr Muhammad Imran Forman Christian College (A Chartered University) Dr Muhammad Imran Forman Christian College.
T.A Nouf Alshareef KAU-Faculty of Science- Biochemistry department Analytical biochemistry lab (Bioc 343) 2012 False colour scanning.
Precipitation.
GEL FILTRATION CHROMATOGRAPHY Size Exclusion Chromatography
Instrumental Analysis (I) HPLC Tutorial 8. Graded presentation Students in groups of 4-5 individuals are asked to prepare a presentation (weight=5% of.
Instrumental Analysis (I)  HPLC Tutorial #7 PHCMt561 – 5 th Sem. Pharm.
Purification of immunoglubin by ion exchange chromatography Bahiya Osrah
Principles of chromatography
Chromatography.
Size exclusion Chromatography
Downloaded from کروماتوگرافی CHROMATOGRAPHY Downloaded from
Tymoczko • Berg • Stryer © 2015 W. H. Freeman and Company
Bioseparation I Centrifugation. What is Bioseparation?  Purification or separation of a specific material of interest from contaminants in a manner that.
BCH BIOCHEMICAL METHODS (2 UNITS) DR AKINLOYE’S ASPECT
Lecture 2: Introduction to Chromatography and Size- Exclusion Chromatography Yaj.
Why Do We Analyze Proteins?
Chapter 4-3 Chromatography Gel Chromatography Dr Gihan Gawish.
Ion Exchange Chromatography
Gel Filtration Chromatography.
Size Exclusion Chromatography (SEC)
Biophysical Tools '04 - Chromatography
Chem. 133 – 5/4 Lecture.
Gel Filtration Chromatography.
Principle of separation of different components:
Downstream Processing
High-Performance Liquid Chromatography
High-Performance Liquid Chromatography
Presentation transcript:

GF v03 Aug Gel Filtration

GF v03 Aug Gel filtration What is gel filtration and why use it? Some typical results Why and when to choose gel filtration Model of the mechanism How to get the expected results Unexpected results and what to do about them

GF v03 Aug What is gel filtration? Gel filtration is a technique of liquid chromatography which separates molecules according to their sizes.

GF v03 Aug Simple to do Easy to understand Nothing to go wrong Gel filtration in the lab

GF v03 Aug Why use gel filtration? Some typical results Group separations: Desalting, Buffer exchange, Removing reagents Purification of proteins and peptides: complex samples, monomer/dimer Estimation size & size homogeneity

GF v03 Aug Desalting proteins Highly efficient desalting in less than 1 minute sec

GF v03 Aug Desalting proteins Desalting in a simple column aa 2 Elution volume (ml) AlbuminNaCl Column: Sample: Buffer: PD-10 HSA, 25 mg NaCl 0.5M

GF v03 Aug Desalting the sample 0 1 min Sample: His tagged protein eluted from HisTrap with 20 mM sodium phosphate, 0.5 M sodium chloride, 0.5 M imidazole, pH 7.4 Column: HiTrap Desalting 5 ml Buffer: 20 mM sodium phosphate, 0.15 M sodium chloride, pH 7.0 System: ÄKTAprime, 5 ml/min

GF v03 Aug Sample: BSA dissolved in 50 mM piperazine, 0.5 M sodium chloride, pH 6.2 Column: HiPrep 26/10 Desalting Buffer: 20 mM sodium phosphate, 0.15 M sodium chloride, pH 7.0 System:ÄKTAprime, 20 ml/min Buffer exchange using HiPrep 26/10 Desalting column

GF v03 Aug Purification of recombinant IGF-1 Column: HiLoad 16/60 Superdex 75 prep grade Sample: IGF-1, ZZ fusion protein and uncleaved material Buffer: 0.15 ammonium acetate, pH 6.0 Flow rate: 0.75 ml/min (22.5 cm/h) 1 2 Time (h) IGF-1 AU

GF v03 Aug Sample: 4 ml concentrated eluate from a HIC run containing rPhosphatase Column: HiLoad 16/60 Superdex 75 prep grade Buffer: 25 mM Tris-HCl, 0.3 M sodium chloride, 1 mM EDTA, 2 mM DTT, pH 7.4 System:ÄKTAprime, 0.5 ml/min (15 cm/h) Purification of recombinant phosphatase

12 Enzyme purification - SDS-PAGE analysis M - LMW markers 1 - Start material 2 - Pool from ion exchange 3 - Pool from HIC 4 - Pool from Superdex 75 pg 4321M M 67k 43k 30k

GF v03 Aug Separating dimer and oligomers from monomer Column: Superdex 75 HR 10/30 Sample: A special preparation of rhGH in distilled water Oligomer Monomer ime (min) Dimer T1020 V O V C 280nm A

GF v03 Aug Characterisation: Size homogeneity HiTrap Chelating 5 ml M r Superdex 200 HR 10/30

GF v03 Aug Estimating molecular size Measure elution position Calculate molecular size

GF v03 Aug Why choose gel filtration? Pros l Fastest for buffer exchange l Very gentle, high yields l Works in any buffer solution l Removes dimers and aggregates l Separates by size Cons l Limited sample volume l Poor selectivity compared with SDS-PAGE

GF v03 Aug Use in group separations l Adjusting pH, buffer type, salt concentration during sample preparation, e.g. before an assay. l Removing interfering small molecules, e.g. EDTA, Gu.HCl l Removing small reagent molecules, e.g. fluorescent labels, radioactive markers. l But not when the protein will precipitate

GF v03 Aug Use in fractionation l Excellent during the polishing stage l Removes dimers and other aggregates l Transfers protein to buffer solution ready for the next set of experiments l Not so suitable if the sample volume is large

GF v03 Aug Use for size estimation l 'Free' information l Gives an estimate of molecular size in any practically any solution l Precision is not so good

GF v03 Aug Nomenclature Gel filtration (Porath, Flodin, 1959) Size exclusion chromatography (Pedersen, 1962) Molecular sieve chromatography (Hjertén, Mosbach, 1962) Gel permeation chromatography (Moore, 1964)

GF v03 Aug Separation mechanism Qualitative model Gel structure Steric exclusion

GF v03 Aug Gel structure AGAROSE A good gel for gel filtration contains about 95% water

GF v03 Aug Gel structure Agarose Dextran A hypothetical structure for Superdex

GF v03 Aug Steric exclusion Molecules are excluded from the gel bead to different extents according to their sizes. Gel bead Very large molecules are completely excluded Very small ones get everywhere

GF v03 Aug Steric exclusion leads to early elution Molecules elute in order of size. The largest molecules come first ; the smallest ones come last.

GF v03 Aug Terms used, defined Calibration curves Selectivity and efficiency Principles of gel filtration

GF v03 Aug Terms and explanations Void volume V o Volume of the gel matrix V s Pore volume V i V o = Void volume V r = Elution volume within the separation range of the gel V i = Inner pore volume = V c - V s - V o V c = Total (geometric) volume of the column VoVo VrVr VtVt VcVc

GF v03 Aug The void volume V o VoVo VrVr Volume Concentration Elution volume for very large molecules, V o

GF v03 Aug V t and V c Volume Concentration VtVt VcVc VoVo VrVr Elution volume for very small molecules, V t Geometric volume of the gel bed, V c

GF v03 Aug The distribution coefficient, K d K d is difficult to get because V i is difficult to measure

GF v03 Aug The coefficient K av K av is easy to get and it is more useful in practice

GF v03 Aug K av for very large and very small molecules

GF v03 Aug K av should always be in the range 0 to 1 VtVt VrVr Volume Concentration Elution volume when K av = 1 Elution with K av > 1 Adsorption has occurred Elution with K av < 0 Serious problem!

GF v03 Aug The number of peaks is limited ml 0 Maximum number of peaks in RPC > ml Maximum number of peaks in gel filtration ca 15 but we are not purifying peaks!

GF v03 Aug Resolution R s Rs = 4 Rs = 0.6 Rs = 1 Resolution = Peak separation Av. peak width

GF v03 Aug Resolution depends on efficiency and selectivity High efficiency Low efficiency High selectivity Low selectivity Efficiency is a measure of peak width Selectivity is a measure of peak separation

GF v03 Aug High efficiency can compensate for low selectivity. If selectivity is high, low efficiency can be tolerated (if large peak volume is acceptable). Resolution depends on efficiency and selectivity Low selectivity High selectivity high efficiency low efficiency high efficiency low efficiency

GF v03 Aug Calibration curves Plotting the elution volume versus the logarithm of molecular mass yields a calibration curve. VrVr log Mr

GF v03 Aug Selectivity curves Plotting K av versus the logarithm of molecular mass yields the selectivity curve of the matrix. The steeper this curve, the greater the difference in elution volume for two molecules of different sizes. K av log M r  K av  log M r  K av  log M r

GF v03 Aug Constructing a selectivity curve K av 1 0 log (M r ) 1. Run standards and determine the elution volume for each. 2. Calculate K av values. 3. Plot log (M r ) for each standard against the calculated K av.

GF v03 Aug Exclusion limit K av 1 0 log (M r ) Exclusion limit All molecules bigger than this elute in the void volume

GF v03 Aug Fractionation range K av 1 0 log (M r ) Fractionation range A selectivity curve is usually fairly straight over the range Kav=0.1 to Kav=0.7

GF v03 Aug Separation ranges of modern supports 1: Superdex Peptide 2: Superdex 75 3: Superdex 200 4: Sephacryl S-100 HR 5: Sephacryl S-200 HR 6: Sephacryl S-300 HR 7: Sephacryl S-400 HR K av , ,000 1,000,000 10,000,

GF v03 Aug Increasing exclusion limit Results depend on selectivity Sephacryl S ml Sephacryl S-300 Sephacryl S-200 BSA Cyt C IgG  -L Cytidine AU 280 Better for larger proteins Better for smaller proteins Best for these proteins

GF v03 Aug Shape effects A gel has different fractionation ranges for native, globular proteins and denatured proteins in random coil Denatured proteins K av log (M r ) Native proteins

GF v03 Aug Shape effects K av 1 log (M r ) Molecules with different shapes have different selectivity curves. Linear polysaccharides Globular proteins

GF v03 Aug V ) N = 5.54 ( WhWh r N = Number of theoretical plates Test: 1% solution of acetone (about 0.5% of column volume), 0.2 AUFS at 280 nm. Alternatively use 2 M NaCl and conductivity monitor. Efficiency W h = Peak width at half peak height VrVr AU 280 2

GF v03 Aug Efficiency Efficiency depends on: Particle size of matrix Particle size distribution of matrix Packing quality of the column Sample (volume and viscosity) Flow rate

GF v03 Aug Band broadening effects To increase efficiency: Lower the flow rate Flow rate Peak width Large particles/large sample molecules Small particles/small sample molecules

GF v03 Aug Band broadening effects Flow rate Peak width Large molecules Small molecules To increase efficiency: Increase the flow rate

GF v03 Aug To increase efficiency: Use uniform beads in well packed columns Band broadening effects Flow rate Peak width Uneven packing Irregular particles Good column packing Uniform spherical particles

GF v03 Aug peak width ml/min Diffusion and the impact of flow rate on peak width Increasing flow rates lead to broad peaks for large molecules. Very low flow rates are not suitable for very small molecules as column diffusion becomes too significant. Peak width Large molecules ml/min Mass transfer Diffusion along column Eddy Diffusion Peak width Small molecules Human serum albumin (Mr 68500) Myoglobin (Mr 16900) Tyrosine (Mr 181) ml/min Peak width ml/min

GF v03 Aug Peak width depends on particle size p Superdex Peptide µm p Superdex 30 prep grade µm

GF v03 Aug Superdex and Sephadex Bed length:60 cm Sample:Mouse monoclonal cell supernatant IgG 1 Sample size:1.2 ml (1 % V c ) Flow rate:0.2 ml/min (6 cm/h), Sephadex G ml/min (50 cm/h), Superdex 200 prep grade Sephadex G-200 Superdex 200 prep grade 600 min 80 min Smaller beads can give both better resolution and shorter separation times

GF v03 Aug x Superdex ® Peptide HR 10/302 x Superdex ® Peptide HR 10/30 Resolution depends on column length Increasing column length increases resolution

GF v03 Aug Column: Superdex Peptide HR 10/30 Resolution depends on sample volume 25µl 200 µl 400 µl

GF v03 Aug Samples which are much more viscous than the eluent give very poor results even for a simple group separation. Resolution depends on sample viscosity Relative viscosity: 1.0 Relative viscosity: 4.2 Relative viscosity: 11.8 Haemoglobin and NaCl, viscosity changed by adding dextran

GF v03 Aug Recommended gels Desalting and other group separations l Sephadex G-25 Fine or Superfine grades Fractionation l Use a pre-packed column! l Superdex or Superdex prep grade l Native proteins: Superdex 200 l Recombinant proteins: Superdex 75 l Peptides: Superdex Peptide or Superdex 30

GF v03 Aug Column size Desalting and other group separations l Volume four times the expected sample volume l Length is not so important Fractionation l Volume ca times the expected sample volume l Length cm

GF v03 Aug Column packing Choose a properly designed column Prepare the gel slurry carefully Pack the column at the temperature at which it will be used Add all the slurry in one smooth movement Pack at constant pressure or constant flow rate Stabilise and equilibrate the packed bed Check the efficiency; re-pack the column if necessary A well-packed column is ESSENTIAL

GF v03 Aug Preparing and applying the sample Preparation Check the viscosity and remove nucleic acids and polysaccharides if necessay Filter or spin to remove particles Volume for desalting: up to 25% column volume Volume for fractionation: 0.5-5% column volume Application Through an adapter at the top of the column or Layering under the eluent

GF v03 Aug Increasing resolution Check the column efficiency Clean and/or re-pack Check that the separation is in the fractionation range Reduce the sample volume Reduce the flow rate Change to a gel with smaller beads Connect two columns in series

GF v03 Aug Trouble shooting Resolution and recovery See the Notes view for ideas which may be of use in answering questions on this topic

GF v03 Aug Trouble shooting Elution earlier than expected See the Notes view for ideas which may be of use in answering questions on this topic

GF v03 Aug Trouble shooting Elution later than expected See the Notes view for ideas which may be of use in answering questions on this topic