© ABB - 1 - 1MRS756828-08 MicroSCADA Pro LEC-LEC co-operation Asan-Baebang Integrated SA/SCADA/DMS delivery Jung-Wook Koh-KRABB/SAS Anssi Salonen-FIABB/SAS.

Slides:



Advertisements
Similar presentations
Requirements Based Evaluation of BPL for Power System Sensing, Command and Control Applications Erich W. Gunther EnerNex Corporation
Advertisements

Universal Fulfillment Organizer Leads CHT to NGOSS
Load Management System with Intermittent Power on the Grid Ruth Kemsley CEng MIMechE MIEE Econnect Ventures Ltd.
Proposed Storage Area Network Facilities For Discussion.
Khaled Mostafa, ABB Electrical Industries, Nov. 2012
A Path breaking Technology for Network Maintenance and Optimization
Frankfurt (Germany), 6-9 June 2011 Douglas Wilson Psymetrix Ltd, UK Douglas Wilson Psymetrix Ltd, UK D. Wilson – UK – Session 4 – Paper ID 0497 Connection.
Hanover-Fair 2002 IEC The world-wide standard for communication in substations HM IEC   Substation Protocols Benefits Customer.
EVD4 - The Smart eVolution Primary distribution circuit-breaker with integrated protection, control and sensors © ABB Group 15. April 2017 | Slide 1 1.
Microgrids and Infrastructure Resiliency RPI Microgrid Workshop Stuart Nachmias October 10, 2013.
Spencer Murray, Sr. Telecom Eng. Distribution Automation.
A Specific application of SCADA (Supervisory Control And Data Acquisition): Feeder Automation System for Medium Voltage Distribution Networks of Istanbul.
Substation Automation (S.A) System Project Supervisor: Stuart Wildy.
April 2004 page 1 Confidential and propietary CentraLine Portfolio c l o s e t o y o u.
Eycon Visual Supervisor
ABB LCC ECS - 1 © 2004  Industrial IT Power Management System Scope & Value Proposition Lead Competence Center Electrical Control Systems.
Connectivity Packages
© ABB Group June 10, 2015 | Slide 1 1MRS A self healing power system for the accurate fault location and zone concept T&D Smart Grids Europe 2012.
ADAM-4572 Ethernet To Modbus Solution Ethernet to Modbus Data Gateway
Industrial Systems Introducing the L90 Universal Relay Advanced transmission line protection and control High-speed current differential protection for.
MIG II DIGITAL FEEDER PROTECTION
Industrial Automation Automation Industrielle Industrielle Automation 1.5Control System Architecture Arquitectura de control Architecture de Contrôle -
SUBSTATION MODELING: PROTECTION AND AUTOMATION
Business Models and Scaling Up Successes Maintaining Interoperability By Open-Standards Design in The Power Distribution For Smarter Grid Khalid W. Darwish,
© ABB - Page 1 Long lifetime guaranteed for IEC Designed for the future... SCL ACSI APP COM.
Product choice offered by ABB Oy, Distribution Automation
G650 Generator Protection & Control System
MicroSCADA Pro in demanding Industrial Applications
MicroSCADA Pro Ordering Tool and Process
4/21/2017 MicroSCADA Pro DMS 600 Matti Kärenlampi FISUB/Österbacka.
Business Data Communications, Stallings 1 Chapter 1: Introduction William Stallings Business Data Communications 6 th Edition.
MicroSCADA Pro Partners Club 04/2007 © ABB MicroSCADA Pro Partners Club SYS Scalability Marko Viitala.
| IPV-MUX-S | IP Gateway. |2|2 | IPV-MUX-S IP Gateway Line Ports | 10/100BaseT Ethernet auto-negotiation | Fiber Optic Module, 100BaseFX |1300nm Multimode.
Frankfurt (Germany), 6-9 June 2011 V Ramesh – India – Session 1: Network components – 1096 Integrated Switching Devices (ISD) V.RAMESH ABB Limited, Nashik,
Presenter: Peter Busch
1 Monitor System Reliability alarm on demand, sag/surge, and etc. Perform Advanced Power Quality Analysis provide real-time trending. Centralized.
1 Product & Technology Quality Excellence Support American Global Products Product & Technology TeSysPort Ethernet Interface for TeSys June 5, 2007.
Medium Voltage products Energy reliability & revenue improvement Speaker: Jean-Yves Pocthier - Schneider Electric France Technical solution for improvement.
Monitoring EMS Infrastructure Ann Moore San Diego Gas & Electric September 13, 2004 EMS Users Group Meeting-St. Louis.
Frankfurt (Germany), 6-9 June 2011  Authors: Reinhard BREHMERWIEN ENERGIE Stromnetz GmbH - Austria Thomas SCHUSTERWIEN ENERGIE Stromnetz GmbH – Austria.
Unit 5 CONTROL CENTERS AND POWER SYSTEM SECURITY.
MicroSCADA Pro Ortviken upgrade & Crimea Wind Power Plant
Ordering Tool Guideline
© Copyright year ABB. All rights reserved BSE033264R0001, Industrial IT for improved productivity.
© 2006 Cisco Systems, Inc. All rights reserved.Cisco Public 1 Version 4.0 Services in a Converged WAN Accessing the WAN – Chapter 1.
Enterprise Systems Business Planning & Logistics Site Manufacturing Operations and Control Area Supervisory Control Basic Control Safety- Instrumented.
Oncor Electric Delivery Intelligent Grid at Oncor Electric Delivery SWEDE Conference Alan Bern – SCADA / Automation Manager May 1, 2008.
© 2003 ABB Group Welcome to ABB Automation !!! We are one of the most successful automation enterprises in Chuvashia Republic and in Russia ABB Automation.
Automation Presentation to KIB-TEK, Northern Cyprus (19/09/2007)
ABB Power Technologies Network Management ABB Industrial IT for Network Management.
Utility Engineers, PC.  Generation  Transmission  Distribution.
Steady State Analysis Of A Microgrid Connected To A Power System
NERC Lessons Learned Summary LLs Published in September 2015.
4/26/2017 MicroSCADA Pro SYS Mikael Molander FISUB/Österbacka.
© 2007 EMC Corporation. All rights reserved. Internet Protocol Storage Area Networks (IP SAN) Module 3.4.
E Ethernet C CAN bus P Profibus HV HV cables LV LV cables (+busbar) S Serial (RS232) Signal cable Other/Unknown Liquid or Gas Cable and/or Bus PCI-XYZ.
S V.MOUNICA 09551A0294.  To increase the distribution rate of present electric supply which is 70% to 100%.  Improving the supply to house holds without.
Welcome to High Volt Power & Control System (02717) /
Dr. Vidya Vankayala Director, Grid Modernization (604) Richard Guo
Intelligent grid expansion – RheinEnergie AG, Germany
SHORT CIRCUIT MONITORING BY USING PLC & SCADA
MicroSCADA Pro Complete Scalability
MicroSCADA Pro Substation Automation Retrofit of Substation SILS
Power distribution and UPS in a single, compact system
APIC 2009 Power and Energy Innovation Forum
Peter Erning, PSP-T11, Power Gen 2010
Substation Automation System
MicroSCADA Pro Product Training
R200 and ATS100 Presentation 01/12/2013.
Presentation transcript:

© ABB MRS MicroSCADA Pro LEC-LEC co-operation Asan-Baebang Integrated SA/SCADA/DMS delivery Jung-Wook Koh-KRABB/SAS Anssi Salonen-FIABB/SAS

© ABB Asan- Baebang integrated SA/SCDA/DMS Introduction Backround data of the Client and project What is Community Energy Supply (CES) Project Brief Scope of the Supply of ABB System Architecture Main functions System Architecture and solution for distribution network communication and automation Split of the delivery and engineerig tasks between ABB Key Challenges, Competition, & Cooperation Summary

© ABB A Energy Supplier builds a P/P & distribution network and supplies electricity & heat to restricted area such as residential area and/or commercial area. KDHC, KNHC, Gas Suppliers, etc. Power trade with KEPCO Generator: 40 – 150MW No. of Circuit Breaker on Distribution Network: 40 – 200 pcs Around 36 projects are on-going. CCPP Distribution Network CES G KEPCO S/S What is Community Energy Supply (CES)?

© ABB Integrated System Project Brief - End Client: Korea National Housing Corporation (KNHC) - Customer: Kaenam Enterprises Ltd. - Area: 3,674,385 m 2 - Population: 27,000 people / 8,700 household - Generation Capacity: 100MW - No. of Feeders and CBs: 12 Feeders / 105 CBs - The first DMS project supplied by a foreign supplier. (KDN was a mono supplier for DMS in Korea.) - The first integrated system including ECMS (S/A) and DMS.

© ABB - 5 -

© ABB Integrated System Scope of Work (1) Product List

© ABB Integrated System - System Engineering, Configuration, and Site Commissioning - Cubicles for 154KV Bus Protection, Tr. Protection, and SWYD control - Cubicle for LV, Diesel Generator, and DC/UPS - Loose relays supply for 22.9KV and 6.6KV SWGR - Cabling Fiber Optic Communication Cables - Communication Interface with FRTUs made in Korea Scope of Work (2)

© ABB ECMS System Architecture of Asan-Baebang CES (1) F/O TCP / IP Network (100Mbps) Ethernet Switch BUS Protection SWYD Control TR Protection 13.8kV,460V, D/G, UPS F/O TCP / IP Network (IEC 61850) 100Mbps OWS1OWS2EWS Event Printer Hard Copier GPS REB670 : 1EA RET670 : 3EA REF541KM : 11EA Toshiba T/L Pro. 4EA 22.9kV RET670 : 3EA REF541KB : 28EA REF541KM : 3EA REF543KB : 9EA COM for DAS Hot-Standby for ECMS & DAS · · · 6LOT · · · 3LOT TR Protection 154kV · · · 6.9kV · · · 13.8kV TR Protection & UPS · · · REF541KM : 3EA REF541KB : 12EA REF543KB : 4EA REM543BM: 23EA 4LOT REC670 : 2EA RET541AM : 2EA REF541KM : 7EA REM543CG: 1EA DMS Field Equip.

© ABB DMS DMS Field Equipment (105 X FRTUs in CBs) Communication Front End 16 pcs serial lines ….. System Architecture of Asan-Baebang CES (2) To OWS F/O DNP3.0 Network

© ABB Location Diagram of Asan-Baebang CES Location 3F Control B/D 13.8kV TR. Pro 2EA C UPS 2EA C 22.9kV TR. Pro 3EA C 480V L/C 6EA C 6.9kV SWGR 42EA 2F 1F 22.9kV GIS & SWGR 40EA 154kV 15+4 C GIS B/D2F Emer. D/G 2EA Ethernet Switch 16 lines

© ABB Control Centre hardware solutions

© ABB Field Ethernet switches and FRTU communcation

© ABB Distribution network automation- PAD switches and FRTUs

© ABB FRTU supervisory and control dialog in MicroSCADA

© ABB Commmunication princible and arrangments for FRTUs

© ABB SYS and COM arrangements

© ABB Communication arragements to FRTUs by DNP 3.0

© ABB Split of the Works between FIABB and KRABB

© ABB DMS functionality

© ABB DMS modules included to scope

© ABB DMS SCADA communication with OPC

© ABB DMS SCADA communication

© ABB DMS automatic falt location isolation  When fault occurs in network DMS analyses and locates the fault using fault detectors on FRTUs  In the next step DMS creates a sequence to isolate the faulted network and restore power not only to beginning of feeder but uses back-up connections to restore ends of the feeder  SYS 600 executes the sequence automatically monitoring success in each step (user has possibility to stop the sequence)

© ABB communication

© ABB TCP/IP adresses allocations

© ABB Integrated System - Siemens, GE, and LSIS proposed two separate systems, S/A and Korean DMS - KDN, the sole vender for DMS system, proposed DMS. - FISUB and KRABB looked for the solution together and proposed. - One system for S/A and DMS. - Communication Interface with Korean FRTU’s. - Stress technically superior and operationally better solution. - Made the client change the specification - Work split between FISUB and KRABB - Plan to extend distribution feeders – additional 56 CB’s Key Challenges, Competition, & Cooperation

© ABB Integrated System Summary Customer’s need Simplified System Field Proven System based on IEC61850 Korean FRTU should be applied Easy Extension ABB’s response ABB can supply one system for S/A and DMS No need to interface between S/A and DMS Korean Standard FRTU can be interfaced Extension is proven in KOGAS Customer’s benefits All information and operation with one system Excellent local competence Reduce the cost Easy extension – plan to extend 56 CBs