Octavian Sima Physics Department Bucharest University

Slides:



Advertisements
Similar presentations
Saed Dababneh. Seventh Symposium on Use of Nuclear Techniques in Environmental Studies. Yarmouk University, JORDAN. 3-5 Sept Manipulated Gamma Spectroscopy:
Advertisements

NUCP 2371 Radiation Measurements II
Stefan Roesler SC-RP/CERN on behalf of the CERN-SLAC RP Collaboration
Advanced GAmma Tracking Array
GEANT4 Simulations of TIGRESS
Simulation of X-ray Fluorescence and Application to Planetary Astrophysics A. Mantero, M. Bavdaz, A. Owens, A. Peacock, M. G. Pia IEEE NSS -- Portland,
19th July 2002, Salamanca 1 Efficiency calibration of a Germanium gamma-ray detector using GEANT4 * Dpto. Física Atómica, Molecular y Nuclear ** Dpto.
 -Ray Emission Probabilities Edgardo Browne Decay Data Evaluation Project Workshop May 12 – 14, 2008 Bucharest, Romania.
Analysis and Results 3.Gamma-ray Spectra of 134 Cs The background subtracted spectra of 605 keV and 796 keV in multiple hit events, and their coincidence.
Accelerator Physics, JU, First Semester, (Saed Dababneh). 1 Principles of Spectrometry.
Precision tests of calculated internal-conversion coefficients: the case of 134 Cs. W. E. Rockwell Cyclotron Institute, TAMU Summer 2005 Advisor: J. C.
Kirov A S, MSKCC Overview of Geant4 Use and Issues in Imaging: Emission Tomography (PET and SPECT) Assen S. Kirov Department of Medical Physics Memorial.
New precise  K measurement as a test of internal conversion theory 166 keV transition in 139 La Christine Balonek Dr. John C. Hardy, Advisor Dr. Ninel.
GAMMA RAY SPECTROSCOPY
Simulations with MEGAlib Jau-Shian Liang Department of Physics, NTHU / SSL, UCB 2007/05/15.
Qualitative, quantitative analysis and “standardless” analysis NON DESTRUCTIVE CHEMICAL ANALYSIS Notes by: Dr Ivan Gržetić, professor University of Belgrade.
Study of e + e  collisions with a hard initial state photon at BaBar Michel Davier (LAL-Orsay) for the BaBar collaboration TM.
Compton Scattering Reporter: Hui He. Outline Theory Experimental setup Experimental results (1) Calibration (2) Angular Distribution of the 137 Cs Source.
Gamma Spectroscopy HPT TVAN Technical Training
Variance reduction A primer on simplest techniques.
Gamma ray spectrum, its acquiring and analysis
Lecture 7 Analytical Quality Control
Workshop on Physics on Nuclei at Extremes, Tokyo Institute of Technology, Institute for Nuclear Research and Nuclear Energy Bulgarian Academy.
Rob Hewitt, Robyn Reist, Jason Sadowski Engineering Physics College of Engineering Student Paper Presentation Competition March 26, 2009 Supervisors: Mike.
Radiation Detection and Measurement, JU, First Semester, (Saed Dababneh). 1 Spectrum if all energy is captured in detector. Allows identification.
Decay Data in View of Complex Applications Octavian Sima Physics Department, University of Bucharest Decay Data Evaluation Project Workshop May 12 – 14,
Gamma-ray efficiency of a HPGe detector as a function of energy and geometry of energy and geometry Mohsen B. Challan Physics Department, Faculty of Education.
1 Lecture 5 Overview on the Analytical Procedures (  ) Lecture 5 Overview on the Analytical Procedures (  ) Moncef Benmansour Moncef Benmansour CNESTEN,
Introduction to MCMC and BUGS. Computational problems More parameters -> even more parameter combinations Exact computation and grid approximation become.
Precision Analysis of Electron Energy Deposition in Detectors Simulated by Geant4 M. Bati č, S. Granato, G. Hoff, M.G. Pia, G. Weidenspointner 2012 NSS-MIC.
25/07/2002G.Unal, ICHEP02 Amsterdam1 Final measurement of  ’/  by NA48 Direct CP violation in neutral kaon decays History of the  ’/  measurement by.
Accurate gamma-ray spectrometry of environmental samples: a challenge O. Sima - Bucharest University D. Arnold - PTB Braunschweig C. Dovlete - ERL Bucharest.
DDEP 2012 | C. Bisch – Study of beta shape spectra 1 Study of the shape of  spectra Development of a Si spectrometer for measurement of  spectra 
Monte carlo radiation transport simulation in dosimetry from environmental modeling to multimillion voxel human phantom Valery Taranenko Institute of Radiation.
Contributions of the University of Bucharest to the study of high energy cosmic rays in the framework of the KASCADE-Grande experiment Octavian Sima Faculty.
3/2003 Rev 1 II.3.15b – slide 1 of 19 IAEA Post Graduate Educational Course Radiation Protection and Safe Use of Radiation Sources Part IIQuantities and.
Forschungszentrum Karlsruhe in der Helmholz-Gemeinschaft Karlsruhe Institute of Technology Nuclear Data Library for Advanced Systems – Fusion Devices (FENDL-3)
Accelerator Physics, JU, First Semester, (Saed Dababneh). 1 Principles of Spectrometry.
Walid DRIDI, CEA/Saclay n_TOF Collaboration Meeting, Paris December 4-5, 2006 DAPNIA Neutron capture cross section of 234 U Walid DRIDI CEA/Saclay for.
ACADs (08-006) Covered Keywords Errors, accuracy, count rate, background, count time, equipment efficiency, sample volume, sample geometry, moisture absorption,
Gamma-induced positron lifetime and age-momentum
Spacecraft Environment & Protection Group GEANT4 Workshop, Noordwijk, Sep 1999 Radioactive Decay Process and Data P Truscott and F Lei Space Department.
DEVELOPMENT OF BETA SPECTROMETRY USING CRYOGENIC DETECTORS M. Loidl, C. Le-Bret, M. Rodrigues, X. Mougeot CEA Saclay – LIST / LNE, Laboratoire National.
G4GeneralParticleSource Class: Developed by ESA as the space radiation environment is often quite complex in energy and angular distribution, and requires.
Test Beam Simulation for ESA BepiColombo Mission Marcos Bavdaz, Alfonso Mantero, Barbara Mascialino, Petteri Nieminen, Alan Owens, Tone Peacock, Maria.
SEM- Schematic Overview. Electron Detection Tungsten Filament Electron Source.
Determination of activity of 51 Cr source on gamma radiation measurements V.V.Gorbachev, V.N.Gavrin, T.V.Ibragimova, A.V.Kalikhov, Yu.M.Malyshkin,A.A.Shikhin.
Accelerator Physics, JU, First Semester, (Saed Dababneh). 1 In the figure: Photoelectric suppressed. Single Compton (effect of crystal dimensions).
Issues on  -Decay Total Absorption Spectroscopy J.L. Tain Instituto de Física Corpuscular C.S.I.C -
26 Oct 2010PC Physics Requirements of Software from Chris R ~19 Oct. My.
ANITA workshop, Uppsala, december 2008 ANITA neutron source Monte Carlo simulations and comparison with experimental data Mitja Majerle Nuclear Physics.
00 Cooler CSB Direct or Extra Photons in d+d  0 Andrew Bacher for the CSB Cooler Collaboration ECT Trento, June 2005.
A.V. Ramayya and J.H. Hamilton Vanderbilt University.
Neutrinoless double electron capture experiment at LSM University of Muenster, Germany (Dieter Frekers et al.) Technical University of Dresden, Germany.
PMN07 Blaubeuren Segmented germanium detectors in 0νββ-decay experiments Kevin Kröninger (Max-Planck-Institut für Physik, München)
“Energy & Transmutation of Radioactive Waste“ collaboration workshop Řež, from June 4 up to June 8 1 Nuclear Physics Institute Řež Methodical comments.
Monte Carlo methods in spallation experiments Defense of the phD thesis Mitja Majerle “Phasotron” and “Energy Plus Transmutation” setups (schematic drawings)
Investigation of the proton-induced reactions on natural molybdenum.
Status of ULE-HPGe Experiment for WIMP Search in YangYang
L. Pandola INFN, Gran Sasso National Laboratories
M.I. Abbas - Alexandria University - EGYPT.
E. G. Androulakaki 1,2, G. Eleftheriou4, E. Fatsea1, M. Kokkoris1, F.K. Pappa1,2, D.L. Patiris2 , E. Skordis3, C. Tsabaris2, R. Vlastou1 1 Department of.
Gamma spectrometric measurements of uranium isotopic composition:
Sr-84 0n EC/b+ decay search with SrCl2 crystal
Lecture 4(Unit II): Gas-Filled Detector Quality Control
NAA using Kayzero: from peak areas to element concentration
Yields of Gamma Radiation of 235U
G4GeneralParticleSource Class:
Recent check of calibration across detectors
Projects by User Groups in Spain: Application to g-ray Spectrometry
Presentation transcript:

Octavian Sima Physics Department Bucharest University Coincidence-summing in Gamma-ray spectrometry. IEC 1452 Standard GESPECOR software Octavian Sima Physics Department Bucharest University IWIRAD 2005

Overview IEC 1452 standard Coincidence-summing effects GESPECOR software - decay scheme data - Monte Carlo simulation - examples Summary and conclusions IWIRAD 2005

1. IEC STANDARD 1452 (1995) Purpose: - to establish methods for the calibration and measurement of energy and  emission rate with Ge detectors and on this basis to assess the activity - to provide tests for checking that the system and the analysis are adequate Calibration and peak analysis Energy and emission rate measurement (corrections) Quality control of the spectrometry system Quality control of the analysis software Quality control of the complete system IEC 973 (1989) – Tests of Ge detectors IEC 1151 (1992) – Amplifiers and preamplifiers for detectors of ionizing radiation IEC 1342 (1995) – Multichannel analysers IWIRAD 2005

Emission rate measurement => required corrections: - count rate in the interfering background peaks - decay corrections - random summing, pile-up corrections - true coincidence-summing corrections - attenuation (self-attenuation + external) True coincidence-summing - magnitude of the effect N(E1)/N(E2) =f(distance) E1E2, E1 with coincidence, E2 without - Appendix C – principles and examples (1-st order) Nuclide identification - peak search, library data Les Annexes (A-E) sont donees uniquement a titre d’informaion IWIRAD 2005

2. Coincidence-summing effects Summing out => losses from peaks (apparent efficiency is lower than correct efficiency) Summing in => additional counts due to1+2 in the peak of 3 (apparent efficiency for 3 is higher than correct efficiency) IWIRAD 2005

Magnitude of coincidence-summing effects Enhanced in high efficiency measurement conditions => more important in present day measurements (tendency to use high efficiency) Depend on the detailed decay scheme of the nuclide (peak energy, probability of emission of other photons in cascade, energy of the cascading photons) => nuclide dependent efficiency Depend on the geometry (including surrounding materials), matrix => Difficult to evaluate: nuclear data + radiation transport IWIRAD 2005

3. GESPECOR GERMANIUM SPECTROSCOPY CORRECTION FACTORS, authors Sima, Arnold, Dovlete Realistic Monte Carlo calculation of: - self-attenuation - coincidence-summing corrections - efficiency (including non-uniform activity distribution) IWIRAD 2005

GESPECOR: coincidence-summing Nuclear data: - sources: NUCLEIDE, ENSDF (Oct. 2004) - 200 nuclides, 250 records - completely automatic evaluation - arbitrary decay scheme - based on graph theory - better than Monte Carlo simulation of the decay scheme - without the limitations of the matrix formalism - user friendly interfaces IWIRAD 2005

IWIRAD 2005

IWIRAD 2005

GESPECOR: coincidence-summing Radiation transport: - realistic Monte Carlo simulation - powerful variance reduction techniques - detailed detector description (including a complex structure of the dead layer) - detailed description of the sample (geometry, matrix) and surrounding materials User friendly interfaces IWIRAD 2005

IWIRAD 2005

IWIRAD 2005

IWIRAD 2005

GESPECOR: coincidence-summing Well-type HPGe detector (PTB, Braunschweig) Higher order effects Count-rate reduction: 6 (1275 keV), 7.5 (511 keV) Good agreement with exp. (5%)

GESPECOR: coincidence-summing Corrected efficiency vs GESPECOR: coincidence-summing Corrected efficiency vs. mono-gamma efficiency (well-type HPGe detector)

- nuclide identification problems Corrections factors for the main peaks required for activity determination, but: All features of the spectra should be correctly described (including small peaks and pure sum peaks) - peak interference - nuclide identification problems Present day tendency: completely automatic analysis of spectra => requires improvement [Arnold, Blaauw, Fazinic, Kolotov, Nucl. Instrum. Meth. A 536 (2005) 196 ] IWIRAD 2005

GESPECOR: coincidence-summing Sum peaks with X-rays (n-type HPGe) Ba-133 point source Corrections in good agreement with experimental data (PTB)

GESPECOR: coincidence-summing Sum peaks with X-rays (n-type HPGe) Ba-133 point source Corrections in good agreement with experimental data (PTB)

4. Summary and conclusions Coincidence-summing effects enhanced in present day measurements All features present in the spectra should be properly described GESPECOR is able to provide correction factors in agreement with experimental values (5% simple decay schemes, 10-15% complex decay schemes, with important higher order corrections) High quality nuclear data required, including the covariance matrix (not yet available) to satisfy the ever increasing quality requirements. IWIRAD 2005