Metrology and Accelerator Applications Graeme Taylor Neutron Metrology Group National Physical Laboratory, Teddington, UK Applications of Particle Accelerators.

Slides:



Advertisements
Similar presentations
Activity measurement of phosphorus-32 in the presence of pure beta-emitting impurities The CSIR Research and Innovation Conference National Metrology Laboratory.
Advertisements

Bureau International des Poids et Mesures The BIPM and the International Reference System (SIR) for activity measurements Bureau International des Poids.
A world of hope through accelerator- based science and technologies.
Unit 3 Part 2 The Periodic Table ICP Mr. Patel SWHS.
LS User’s Forum 2001 Developments in LSC Andy Pearce CIRM Date: 5th September 2001.
Presentation to: LSUF Liquid Scintillation Users Forum – Introduction – NPL Mike Woods September 2001.
NPL’s activities dosimetry for proton and ion therapy Hugo Palmans Radiation Dosimetry Team, National Physical Laboratory, Middlesex, UK
Report of the BIPM Ionizing Radiation Department José M. Los Arcos CCRI Executive Secretary IR Department Director CCRI(III) BIPM, 4-6 March.
Supported by the European Commission, contract number: Fission , and the Research.
Photon and Energy Fluence
The Nature of Molecules
Periodic Table – Filling Order
INRNE BAS NEC'2007, Varna, Bulgaria Positron annihilation versus electron cloud Angel H. Angelov Institute for Nuclear Research and Nuclear Energy.
Neutron (no charge) Hydrogen 1 Proton 1 Electron Oxygen 8 Protons 8 Neutrons 8 Electrons a. b. proton (positive charge) electron (negative charge) Copyright.
Development of the Periodic Table. Mendeleev’s Periodic Table "...if all the elements be arranged in order of their atomic weights a periodic repetition.
Metals, Nonmetals, Metalloids. Metals and Nonmetals Li 3 He 2 C6C6 N7N7 O8O8 F9F9 Ne 10 Na 11 B5B5 Be 4 H1H1 Al 13 Si 14 P 15 S 16 Cl 17 Ar 18 K 19 Ca.
Aurelian Luca (IFIN-HH, Romania) The Decay Data Evaluation Project – an international cooperation in the field of nuclear data.
Unit 4 The Periodic Table Chemistry I Mr. Patel SWHS.
CHAPTER 2: The Chemistry of Life BIO 121. Chemistry is relevant… (even if we don’t like it)
Milestones M5 and M6 Mid-Term Review, October 2013M. Silari – ARDENT overview1 M5: comparison of detector technologies (WP1) M6: choice of detector technology.
Periodic Table of Elements. gold silver helium oxygen mercury hydrogen sodium nitrogen niobium neodymium chlorine carbon.
Program of Work of the Ionizing Radiation Department José M. Los Arcos CCRI Executive Secretary IR Department Director CCRI(III) BIPM, 4-6 March.
Trends of the Periodic Table
Periodic Table Of Elements
Metals, Nonmetals, Metalloids
TECO2005WRC/PMOD Quality Management1 The World Radiometric Reference and its Quality System ISO/IEC Wolfgang Finsterle, Isabelle Rüedi, and Silvio.
The National Standard of the Radionuclides Activity Unit in Poland R. Broda, A. Chyliński, T. Radoszewski, K. Małetka, T. Terlikowska-Droździel Radioisotope.
Introductory to the English “NMS” Model The English National Measurement System (NMS) is –in short – described, as illustration of an efficient National.
s p d (n-1) f (n-2) 6767 Periodic Patterns 1s1s1s1s 2s2s2s2s 3s3s3s3s 4s4s4s4s 5s5s5s5s 6s6s6s6s 7s7s7s7s 3d3d3d3d 4d4d4d4d 5d5d5d5d 6d6d6d6d 1s1s1s1s.
Organization of The Periodic Table Mrs. Russotto.
Bellwork, Fri. Sept. 14 Which element is LEAST likely to combine with another element to form a molecule? -Chlorine (Cl), a halogen -Iron (Fe), a metal.
ARDENT Advanced Radiation Dosimetry European Network Training initiative WP1: Gas Detectors S. Rollet.
Med Phys 3A03/3AA1 Practical Health & Medical Physics Communications D.R. Chettle, with D.F. Moscu TA: Helen Moise.
Passive detectors (nuclear track detectors) – part 2: Applications for neutrons This research project has been supported by the Marie Curie Initial Training.
Modern Periodic Table Objective:
Introduction to Mineralogy Dr. Tark Hamilton Chapter 3: Lecture 7 The Chemical Basis of Minerals (sizes, shapes & directions) Camosun College GEOS 250.
International Atomic Energy Agency Roles and responsibilities for development of disposal facilities Phil Metcalf Workshop on Strategy and Methodologies.
Periodic Table Li 3 He 2 C6C6 N7N7 O8O8 F9F9 Ne 10 Na 11 B5B5 Be 4 H1H1 Al 13 Si 14 P 15 S 16 Cl 17 Ar 18 K 19 Ca 20 Sc 21 Ti 22 V 23 Cr.
Periodic Table of Elements
Chapter 6 Metals, Nonmetals, Metalloids. Metals and Nonmetals Li 3 He 2 C6C6 N7N7 O8O8 F9F9 Ne 10 Na 11 B5B5 Be 4 H1H1 Al 13 Si 14 P 15 S 16 Cl 17 Ar.
Trends of the Periodic Table. Electronegativity ElectronegativityyElectronegativityy.
Teacher Notes This PPT was revised June 10, This PPT is a review on the atomic characteristics of the four main essential elements hydrogen, carbon,
DEVELOPMENT OF THE NATIONAL INFRASTRUCTURE FOR NUCLEAR POWER IN VIETNAM DEVELOPMENT OF THE NATIONAL INFRASTRUCTURE FOR NUCLEAR POWER IN VIETNAM Vuong Huu.
UK X-FEL National Laboratory Perspective Susan Smith STFC ASTeC IoP PAB/STFC Workshop Towards a UK XFEL 16 th February 2016.
Neutron production and iodide transmutation studies using intensive beam of Dubna Phasotron Mitja Majerle Nuclear Physics Institute of CAS Řež, Czech republic.
Periodic Table Li 3 He 2 C6C6 N7N7 O8O8 F9F9 Ne 10 Na 11 B5B5 Be 4 H1H1 Al 13 Si 14 P 15 S 16 Cl 17 Ar 18 K 19 Ca 20 Sc 21 Ti 22 V 23 Cr.
Periodic Table of Elements
Consultative Committee on Ionising Radiation (CCRI) June 2016
Introduction To Chemistry
1 H 2 He 3 Li 4 Be 5 B 6 C 7 N 8 O 9 F 10 Ne 11 Na 12 Mg 13 Al 14 Si
Chemeketa Community College
Periodensystem Biomaterials Research - Manfred Maitz H He Li Be B C N
Emission of Energy by Atoms and Electron Configurations
Trends of the Periodic Table
Periodic Table Kelter, Carr, Scott, Chemistry A Wolrd of Choices 1999, page 74.
WHAT THE HECK DO I NEED TO BE ABLE TO DO?
NPL accelerator facility
Periodic Table of the Elements
4.2 IONIZATION ENERGY 4.6 TABLE 4.2 Ionization Energy of the Elements
Introduction To Chemistry
PERIODIC TABLE OF ELEMENTS
Electron Configurations
DETECTION LIMITS < 1 ppt ng/L 1-10 ppt ng/L ppt ng/L
Chemistry – Nov 20, 2018 P3 Challenge- Objective –
Edexcel Topic 1: Key concepts in chemistry
Line Spectra and the Bohr Model
Dosimetry Standards at NMIJ/AIST Ionizing Radiation Standards Group
Electron Configurations and the Periodic Table
→ Atomic radius decreases → Ionization energy increases → Electronegativity increases →
A world of hope through accelerator- based science and technologies.
Presentation transcript:

Metrology and Accelerator Applications Graeme Taylor Neutron Metrology Group National Physical Laboratory, Teddington, UK Applications of Particle Accelerators in Europe June 2015 Royal Academy of Engineering

Metrology and Accelerator Applications Graeme Taylor Neutron Metrology Group National Physical Laboratory, Teddington, UK Applications of Particle Accelerators in Europe June 2015 Royal Academy of Engineering Neutron

Scope  Brief overview of NPL  Overview of Neutron Metrology Accelerator-based facilities  Introduction to BIPM (comparability of measurements) Ionising radiation Monoenergetic neutron providers  Current / future plans for accelerators at European NMIs  1 slide on proton and ion beam dosimetry at NPL  1 slide on the 2011 EMRP bid for HE Neutron Reference Fields

The UK National Physical Laboratory

Science divisions of the National Physical Laboratory Acoustics & Ionising Radiation Analytical Science Engineering Measurement MaterialsTime, Quantum & Electromagnetics Acoustics Radiation Dosimetry Radioactivity Neutron Metrology Environmental Measurements Nanoanalysis Gas Metrology & Trace Analysis Biotechnology Engineering Measurement Services Temperature & Humidity Mass & Dimensional Optical Measurement Advanced Engineered Materials Thermal & Electrochemical Nano & Multifunctional Materials Materials Processing & Performance Electronics & Modelling Communication Technologies Quantum Detection Quantum Frequency Standards Time & Security Electrical & Instrumentation Electromagnetics

Aims and capabilities Role: Ensure measurements in the UK are consistent and to the required accuracy The Neutron Metrology Group, NMG, provides: Characterised neutron fields Traceable calibrations Type test facilities Neutron spectrometry capabilities (field mmts) Research into dosimetry techniques

Chadwick building: home of the Neutron Metrology Group Two Facilities Neutron emission rate measurement facility Low scatter irradiation facility Instrumentation Field spectrometers Microdosimeters Area and personal dosemeters

Main experimental area Low Scatter Facility: 18 m wide x 18 m high x 26 m long Used for: Monoenergetics ‘Multienergy’ Simulated fields Isotopic sources Additional facility: Thermal Pile

Van de Graaff accelerator 3.5 MV accelerator Proton & deuteron ion sources Energy width ~3 keV Beam currents: < 20 uA (LSA) ~80 uA (pile) Installed mid-1960s (modular design) Time-of-flight capability* *On a good day!

VdG control desk

Monoenergetic neutrons (ISO) energies and intensities Neutron Energy (MeV) Reaction Maximum rates at 1 m Fluence (cm -2 s -1 ) H*(10) (μSv h -1 ) Sc(p,n) 45 Ti Li(p,n) 7 Be Li(p,n) 7 Be Li(p,n) 7 Be Li(p,n) 7 Be T(p,n) 3 He T(p,n) 3 He D(d,n) 3 He T(d,n) 4 He

‘Multienergy’ facility Fluence response function of PADC personal neutron dosimeter

Thermal pile Graphite block: 2.8 m long x 1.4 m wide x 1.6 m high

Thermal column field Significant fast neutron component 2 nd Irradiation with Cd cover required Fluence rates ~4 × 10 4 cm -2 s -1 Beam area ~ 30 cm diameter Components:FastThermal Fluence 19% 81% H*(10) 69% 31% H*(10) rate of thermal field: ~1 mSv h -1

NPL simulated workplace field facility ‘Thick’ Al / Li alloy Moderation: 40 cm dia. sphere of D 2 O Max. rates at 150 cm: Fluence: 2000 cm -2 s -1 H*(10): 180 μSv h -1

Testing the Rospec in the simulated workplace field Fluence (cm -2 ) H*(10) (  Sv) NPL 1.30 x Rospec 2.01 x Ros/NPL

Global providers of monoenergetic neutrons IRMM VNIIM

Looking to the future (accelerator-based neutron metrology in Europe)  PTB Germany Approval for new Tandetron 2 MV accelerator granted Under construction by HVEE in Amersfoort/Netherlands Expected delivery Q2-Q  IRSN France Already have a 2 MV Tandetron from HVEE Off-line 2014 – 2016 for installation of 2 nd beam line for microbeam facility  NPL Discussions re: accelerator replacement at early stage

Proton and ion beam dosimetry at NPL  development of a primary standard for protons and ions based on a portable graphite calorimeter  improved measurements of the mean energy required to produce an ion pair in air for ionisation chamber dosimetry in proton and ion beams  improved measurement and simulation using Monte Carlo methods of ionisation chamber perturbation factors;  characterisation of energy dependent absorbed dose response of relative dosimeters: alanine, radiochromic film  Improved dose conversion from different materials to water  develop SQUID-based micro-calorimeter to measure ion beam microdosimetric spectra to underpin the definition of more biologically relevant quantity for radiotherapy.

2011 EMRP bid for HE Neutron Reference Fields (Failed!)  Secondary radiation produced during ion (proton / carbon) therapy consists primarily of high-energy neutrons  Characterization and calibration of dosemeters used in such fields require traceable neutron reference fields in the energy ranges under consideration (up to “a few 100 MeV”)  No metrological facilities for this purpose in Europe  Several proton / carbon ion therapy centres already in operation and more will start treatment in next few years  There is a need to provide metrological infrastructure for such reference fields and provide them to stakeholders  Proposed to develop such reference fields at existing proton therapy facilities.

The National Measurement System is the UK’s national infrastructure of measurement Laboratories, which deliver world-class measurement science and technology through four National Measurement Institutes (NMIs): LGC, NPL the National Physical Laboratory, TUV NEL The former National Engineering Laboratory, and the National Measurement Office (NMO). The National Measurement System delivers world-class measurement science & technology through these organisations

Program of Work of the Ionizing Radiation Department José M. Los Arcos CCRI Executive Secretary IR Department Director CCRI(III) BIPM, 4-6 March 2015 CCRI/15-18

Bureau International des Poids et Mesures PoW : IR priority activities  Aim of Ionizing radiation activities to provide Member States with metrological support to provide confidence in the services that the NMIs offer to their users, based on a well-defined and stable set of international reference facilities to compare and establish the equivalence or traceability of the national standards for dosimetry and radionuclide activity in health applications (radiotherapy, nuclear medicine, radiodiagnostic), nuclear industry, environmental survey and related activities.

Bureau International des Poids et Mesures PoW : Dosimetry activities IR-A1.3 High-energy dosimetry (accelerator dosimetry) Target: the BIPM.RI(I)-K6 on-going comparisons of absorbed dose to water for high-energy photon beams, using the transportable BIPM graphite calorimeter on-site at the NMIs. Scope: establishing and maintaining the long-term equivalence and traceability of absorbed dose for photons and eventual extension to electrons (see IR- A1-5 in alternative projects) in high-energy beams now used in the vast majority of radiotherapy applications. Participant NMIs: 16 1)Maintaining the transportable photon calorimeter standard to provide robust traceability for absorbed dose through on- site comparisons and characterizations of national standards, 2)Providing 4-6 BIPM.RI(I)-K6 comparisons on-site at the NMIs, 3)Continued study of long-term optimal scenario for a sustainable maintenance of BIPM.RI(I)-K6 comparisons, using the BIPM graphite calorimeter standard. IR-A1.4 Brachytherapy Target: the BIPM.RI(I)-K8 on-going comparisons of reference air kerma using two transportable transfer instruments on-site at the NMIs. Scope: establishing and maintaining the long-term equivalence of reference air kerma for HDR 192 Ir sources, and eventual extension to LDR 125 I sources, worldwide used in brachytherapy applications. Participant NMIs: 15 1)Maintaining the BIPM transfer standards (thimble and well- type chambers) for brachytherapy. 2)Providing 4 BIPM.RI(I)-K8 on-site comparisons for NMIs of reference air kerma for HDR 192 Ir sources, as adopted by the CCRI. 3)Study on the convenience and feasibility of future development of a primary standard. Proposal at CCRI-2017.

VNIIM

Program of Work of the Ionizing Radiation Department José M. Los Arcos CCRI Executive Secretary IR Department Director CCRI(III) BIPM, 4-6 March 2015 CCRI/15-18

Index o Terms of reference PoW Mission and Role of the BIPM BIPM objectives o IR priority activities Dosimetry Radionuclide measurements International coordination o Alternative activities

Bureau International des Poids et Mesures Terms of Reference “Programme of work and budget of the BIPM for the four years ” CIPM, 2015 Pending of publication by the CIPM

Bureau International des Poids et Mesures PoW : Mission and Role of the BIPM  The mission of the BIPM is: to ensure and promote the global comparability of measurements, including providing a coherent international system of units for: - Scientific discovery and innovation, - Industrial manufacturing and international trade, - Sustaining the quality of life and the global environment.  The unique role of the BIPM is based on its international and impartial character enabling it: To coordinate the realization and improvement of the world ‑ wide measurement system to ensure it delivers accurate and comparable measurement results. To undertake selected scientific and technical activities that are more efficiently carried out in its own laboratories on behalf of Member States. To promote the importance of metrology to science, industry and society, in particular through collaboration with other intergovernmental organizations and international bodies and in international forums.

Bureau International des Poids et Mesures PoW : The objectives of the BIPM  BIPM objectives: To establish and maintain appropriate reference standards for use as the basis of a limited number of key international comparisons at the highest level. To coordinate international comparisons of national measurement standards through the Consultative Committees of the CIPM; taking the role of coordinating laboratory for selected comparisons of the highest priority and undertaking the scientific work necessary to enable this to be done. To provide selected calibrations for Member States. To coordinate activities between the NMIs of Member States, such as through the CIPM MRA, and to provide technical services to support them. To liaise as required with relevant intergovernmental organizations and other international bodies both directly and through joint committees. To organize scientific meetings to identify future developments in the world-wide measurement system required to meet existing and future measurement needs in industry, science and society. To inform, through publications and meetings, the science community, the wider scientific public and decision makers on matters related to metrology and its benefits.

Bureau International des Poids et Mesures PoW : IR priority activities  Aim of Ionizing radiation activities to provide Member States with metrological support to provide confidence in the services that the NMIs offer to their users, based on a well-defined and stable set of international reference facilities to compare and establish the equivalence or traceability of the national standards for dosimetry and radionuclide activity in health applications (radiotherapy, nuclear medicine, radiodiagnostic), nuclear industry, environmental survey and related activities.

Bureau International des Poids et Mesures PoW : Dosimetry activities Project CodeProject NameDeliverables IR-A1.1 X-ray standards dosimetry Target: the BIPM.RI(I)-K2,-K3,-K7 on-going comparisons of air kerma or absorbed dose to water for low-, medium-energy and mammography, using the high- stability BIPM facilities. Scope: establishing and maintaining the long-term equivalence or traceability of NMIs for nearly 20 x-ray radiation qualities adopted by the CCRI and widely used in radiotherapy and radiodiagnostics. Participant NMIs: 25 1) Maintaining the BIPM primary standards for: - air kerma in low- (5 qualities) and medium-energy (4 qualities) x- rays, - absorbed-dose to water in medium-energy x-rays developed in (4 qualities), - air kerma for mammography (4 qualities). 2) Providing 16 comparisons (BIPM.RI(I)-K2, -K3, -K7) for NMIs that need to update their results in the KCDB, 3) Calibration and characterization of 16 NMIs standards for x-rays, on request. 4) Replacement of HV generator for low-energy x-rays, in 2016 IR-A1.2  -ray standards dosimetry Target: the BIPM.RI(I)-K1,-K4,-K5 and -K6 on-going comparisons of air kerma and/or absorbed dose to water for 60 Co and 137 Cs, using the high-stability BIPM facilities. Scope: establishing and maintaining the long-term equivalence or traceability of NMIs for 60 Co and 137 Cs beams, widely used at radiotherapy and/or radioprotection levels, and serving as reference for the calorimetric measurements in high-energy photon beams (medical accelerators). Participant NMIs: 25 1)Maintaining the BIPM primary standards for: - air kerma in 60 Co and 137 Cs beams for radiotherapy and radioprotection (BIPM.RI(I)-K1, K5), - absorbed dose to water in 60 Co beams (radiotherapy, BIPM.RI(I)-K4), - providing reference to the graphite calorimeter standard for absorbed dose to water in high-energy beams (BIPM.RI(I)- K6). 2)Providing 20 comparisons (-K1, -K4, -K5) for NMIs that need to update their results in the KCDB. 3)Characterization and calibration of 40 national standards (on request). 4)Replacement of 60 Co source in IR-A1 Dosimetry Program for international equivalence of measurements in the Health field: radiotherapy, radiodiagnostics and radioprotection

Bureau International des Poids et Mesures PoW : Dosimetry activities IR-A1.3 High-energy dosimetry (accelerator dosimetry) Target: the BIPM.RI(I)-K6 on-going comparisons of absorbed dose to water for high-energy photon beams, using the transportable BIPM graphite calorimeter on-site at the NMIs. Scope: establishing and maintaining the long-term equivalence and traceability of absorbed dose for photons and eventual extension to electrons (see IR- A1-5 in alternative projects) in high-energy beams now used in the vast majority of radiotherapy applications. Participant NMIs: 16 1)Maintaining the transportable photon calorimeter standard to provide robust traceability for absorbed dose through on- site comparisons and characterizations of national standards, 2)Providing 4-6 BIPM.RI(I)-K6 comparisons on-site at the NMIs, 3)Continued study of long-term optimal scenario for a sustainable maintenance of BIPM.RI(I)-K6 comparisons, using the BIPM graphite calorimeter standard. IR-A1.4 Brachytherapy Target: the BIPM.RI(I)-K8 on-going comparisons of reference air kerma using two transportable transfer instruments on-site at the NMIs. Scope: establishing and maintaining the long-term equivalence of reference air kerma for HDR 192 Ir sources, and eventual extension to LDR 125 I sources, worldwide used in brachytherapy applications. Participant NMIs: 15 1)Maintaining the BIPM transfer standards (thimble and well- type chambers) for brachytherapy. 2)Providing 4 BIPM.RI(I)-K8 on-site comparisons for NMIs of reference air kerma for HDR 192 Ir sources, as adopted by the CCRI. 3)Study on the convenience and feasibility of future development of a primary standard. Proposal at CCRI-2017.

Bureau International des Poids et Mesures PoW : Radionuclide activities Project CodeProject NameDeliverables IR-A2.1 International Reference System (SIR) for  emitters Target: the BIPM.RI(II)-K1 on-going comparisons of activity of solutions of  -ray emitting radionuclides, using high-stability well-type ionization chambers and 226 Ra sources. Scope: establishing and maintaining the equivalence for more than 60 different radionuclides widely used in nuclear medicine or appearing in the nuclear cycle and environmental monitoring. Participant NMIs: 25 1)Maintenance and development of SIR facility for  emitters future core comparisons 2) 40 BIPM.RI (II) – K1 bilateral ‘on demand’ comparisons as part of, covering (at least): C-11 F-18 Na-22 Na-24 Sc-46 Sc-47 Cr-51 Mn-54 Mn-56 Co-56 Co-57 Co-58 Co-60 Fe-59 Cu-64 Zn-65 Ga-67 Se-75 Kr-85 Sr-85 Y-88 Nb-95 Mo-99 Tc-99m Ru-103 Ru-106 Cd-109 Ag-110m Ag-111 In-111 Sn-113 I-123 Sb-124 Sb-125 I-125 I-131 Ba-133 Xe-133 Cs-134 Cs-137 Ce-139 Ba-140 Ce-141 Ce-144 Eu-152 Gd-153 Sm-153 Eu-154 Eu-155 Ho-166m Yb-169 Lu-177 Ta-182 Re-186 Ir-192 Au-195 Tl-201 Hg-203 Pb-203 B i-207 Rn-222 Th-228 Np-237 Am-241 Am ) Reduction of the total number of comparisons through further development of the Measurements Method Matrix (MMM) IR-A2.2 International Reference System (SIR) for pure β emitters Target: the BIPM.RI(II)-K1 on-going comparisons of activity of solutions of pure β emitters, using liquid- scintillation counting methods. Scope: establishment of equivalence for approximately 15 different radionuclides widely used in nuclear medicine, nuclear cycle and environmental monitoring. Participant NMIs: 20 1)Operation, maintenance and development of SIR facility for β emitters, implemented in , for future core comparisons 2) 20 BIPM.RI (II) – K1 bilateral comparisons covering (on demand): 3 H, 14 C, 32 P, 55 Fe, 63 Ni, 89 Sr, 90 Sr/Y, 99 Tc, 147 Pm, 204 Tl and other radionuclides demanded by NMIs. 3) Reduction of current heavy-logistics K2 comparisons to a minimum 4) Reduction of the total number of comparisons through further development of the Measurements Method Matrix (MMM) IR-A2 Radionuclides Program for international equivalence of measurements in the health, environmental and industrial fields: nuclear medicine, radiodiagnostics, PET nuclides, radiotherapy, monitoring contamination of food or environment and safe nuclear activities.

Bureau International des Poids et Mesures PoW : Radionuclide activities IR-A2.3 Extension of SIR to α emitters Target: implementation of methods for extending to  emitters the BIPM.RI(II)-K1 on-going comparisons of activity of solutions of radionuclides. Scope: establishment of equivalence for about 10 radionuclides of interest in the nuclear cycle, nuclear medicine, radiotherapy and environmental survey. Participant NMIs: 10 1)Development and Implementation of liquid scintillation methods or  -particle counting using defined solid angle detectors. 2) 10 BIPM.RI (II) – K1 bilateral comparisons, covering (on demand): 241 Am, 223 Ra, 211 At, 238 Pu, 210 Po and other radionuclides demanded by NMIs. 3)This will allow to complete (with IR-A2.1 and IR-A2.2) the frame for the most common α-, β- and  -emitters 4)Reduction of the total number of comparisons through further development of the Measurement Methods Matrix IR-A2.4 International reference facility for comparison of short-lived  -emitting radionuclides Target: the BIPM.RI(II)-K4 on-site (at NMIs) on-going comparisons of short-lived radionuclides, using the transportable transfer instrument (SIRTI). Scope: establishment of equivalence for about 10 short-lived  -emitting radionuclides of interest in nuclear medicine, PET, molecular imaging. Participant NMIs: 15 1)Maintenance and development of the SIR Transfer Instrument for on- site comparisons and extension to new radionuclides. 2) 8 BIPM.RI (II) – K4 bilateral comparisons covering (on demand): 99m Tc, 18 F, 64 Cu, 11 C, 68 Ga, 211 At, 56 Mn and other radionuclides demanded by NMIs. 3) Reduction of the total number of comparisons through further development of the Measurements Method Matrix (MMM) IR-A2.5 Reference instruments for primary measurements Target: provision of new SIR entries for improvement of KCRVs not well established, applying and developing technical skills of staff for efficient comparisons coordination. Scope: the KCRVs improvements for about 15 radionuclides as support to traceability/equivalence of radionuclide comparisons. Participant NMIs: 15 1)Maintenance and further development of 4  -  (anti)coincidence counting and TDCR LSC systems. 2)Organization of 1 CCRI comparison, for 109 Cd, and participation in 2 CCRI comparisons according to the Rolling Plan and the MMM table. 3) Establish missing KCRVs for 47 Sc, 68 Ge, 111 Ag, 140 Ba, 155 Eu, 195 Au and improve KCRVs for 24 Na, 56 Co, 123 I, 124 Sb, 125 Sb, 153 Sm, 154 Eu, 166m Ho, 177 Lu, as priorities.

Bureau International des Poids et Mesures PoW : Radionuclide activities IR-A2.6 Establishment of operational capability for low- level activity measurements of  and  emitters Target: to complete the capability of low-level activity measurements for  and  emitters. Scope: support to CCRI comparisons on environmental and reference materials programs for international cooperation. Participant NMIs: 12 1)Acquisition, Monte Carlo simulation and setup of a 4  -  NaI(Tl) well-type detector for  emitters. 2)Operational use of the existing Quantulus 1220 LSC spectrometer for  emitters. 3)Participation/organization of 1 CCRI comparison on low-level measurements of contaminated materials IR-A2.7 Development of physical backup to SIR 226 Ra sources Target: prevention of long-term obsolescence of 226 Ra sources (IR-A2.1), by implementing as replacement an electronic absolute current source. Scope: enhanced robustness of SIR in the long- term, as additional safeguard to the equivalence of more than 60  emitters widely used in nuclear medicine or appearing in the nuclear cycle and environmental monitoring. Participant (related) NMIs: 25 1)Feasibility and eventual construction and operation of an electronic current source of high stability and reproducibility. 2)Parallel operation of the electrical source and comparison of performance with the 226 Ra sources. 3)In case of positive answer to point 1) gradual replacement and elimination of 226 Ra sources used in the SIR.

Bureau International des Poids et Mesures PoW : Coordination activities CIR-A1.1 Support to CCRI Provision of CCRI Executive Secretary, general support to CC and WGs plus specifically support for: 1.Biennial CCRI and sections I, II and III meetings 2.Regular meetings of 5 working groups 3.Review of CC and RMO comparison reports before publication 4.Development of strategic plans 5.Publication of BIPM Monographies 6.Review of CC and RMO comparison reports before publication 7.Related liaisons with RMOs CIR-A1.4 Support to JCGM/WG1 - Regular meetings and Rapporteur CIR-A1.5 International scientific collaboration - International Commission on Radiation Units (ICRU) (Commissioner and sponsor of Report Committees), - International Atomic Energy Agency (IAEA) (SSLD Scientific Committee), - International Committee for Radionuclide Metrology (ICRM) (Scientific Committee and technical refereeing) COORDINATION ACTIVITIES

Bureau International des Poids et Mesures PoW : ALTERNATIVE activities Project NameDeliverables IR-A1.3.1 (alternative item) High-energy electron dosimetry (accelerator dosimetry) See IR-A1.3 in prioritised projects for details 1)Development of a calorimeter standard for high- energy electrons, with the aim of providing equivalence and traceability for absorbed dose in electron beams through comparisons and characterizations of national standards. Requires 1 additional staff and frequent accessibility to an accelerator. IR-A1.4.1 (alternative item) Brachytherapy See IR-A1.4 in prioritised projects for details 1)Extension to LDR 125I sources, to be decided by the CCRI(I) in 2015: 4 comparisons. Alternative (Not-funded) activities IR-A2.8 (alternative project) Development of the Becquerel ionization chamber Target: prevention of eventual future obsolescence (long-term) of the SIR ionization chambers (IR-A2.1), by using an optimized backup chamber. Scope: enhanced robustness of SIR in the long-term, as additional safeguard to the current equivalence of more than 60  emitters used in nuclear medicine or appearing in the nuclear cycle and environmental monitoring. Participant (related) NMIs: 25 1)Analysis of conclusions of the BqWG(II) “Realization of the Becquerel” project (design robust, highly stable and reproducible chamber), and decision making about its suitability for the BIPM SIR. 2)If relevant to the BIPM, construction of the first BIPM prototype, operation in parallel to the conventional SIR chambers and comparison of performance. 3)If not relevant, prevision of backup of the existing chambers using commercial equipment.

Bureau International des Poids et Mesures PoW : ALTERNATIVE activities IR-A4.1 (alternative project) BIPM internal service of thermometry calibrations - Internal calibration service of SPRTs and laboratory thermometers. Project CodeProject NameDeliverables IR-A2.9 (alternative project) Development of a sandwich-type coincidence counter for  -  emitters Target: new reference instrument to complete the primary measurement methods (IR-A2.5) available at the BIPM and the technical skills of staff for provision of new SIR entries and efficient comparisons coordination. Scope: comparisons of radionuclides used in nuclear medicine or appearing in the nuclear cycle and environmental monitoring. Participant (related) NMIs: 25 1)Design, construction and experimental setup. 2)Operational tests with  -  emitters. 3)Support to CCRI ( 109 Cd) and BIPM comparisons.