BMI I FS05 – Class 4 “Nuclear Imaging: Math” Slide 1 Biomedical Imaging I Class 5 – Radionuclide Imaging (PET, SPECT), Part 3: Attenuation and Scatter.

Slides:



Advertisements
Similar presentations
Instruments for Radiation Detection and Measurement Lab # 4.
Advertisements

What are PET basics?.
Image Reconstruction.
6: Positron Emission Tomography
Chapter 8 Planar Scintigaraphy
A New Approach to Cluster Finding and Hit Reconstruction in Cathode Pad Chambers and its Development for the Forward Muon Spectrometer of ALICE A.Zinchenko,
Buxton & District Science Discussion Medical Scanners Marge Rose 16 th November 2012.
Fysisk institutt - Rikshospitalet 1. 2 Overview Gamma camera Positron emission technology (PET) Computer tomography (CT) Proton therapy Electrical impedance.
Nuclear Medicine Spring 2009 FINAL. 2 NM Team Nuclear medicine MD Nuclear medicine MD Physicist Physicist Pharmacist Pharmacist Technologist Technologist.
Medical Imaging Mohammad Dawood Department of Computer Science University of Münster Germany.
Medical Imaging Mohammad Dawood Department of Computer Science University of Münster Germany.
Topics in Medical Physics Xiaoming Zheng, PhD. School of Dentistry and Health Sciences December 2009, Chengdu.
Imaging PET Course Layout Class + ContentDateClass Physical Principles of PET I Physical principles of MRI II Imaging applications III.
Transforming Static CT in Gated PET/CT Studies to Multiple Respiratory Phases M Dawood, F Büther, N Lang, X Jiang, KP Schäfers Department of Nuclear Medicine,
Introduction to Medical Imaging
tomos = slice, graphein = to write
PHYSICS IN NUCLEAR MEDICINE: QUANTITAITVE SPECT AND CLINICAL APPLICATIONS Kathy Willowson Department of Nuclear Medicine, Royal North Shore Hospital University.
Planar scintigraphy produces two-dimensional images of three dimensional objects. It is handicapped by the superposition of active and nonactive layers.
The content of these slides by John Galeotti, © Carnegie Mellon University (CMU), was made possible in part by NIH NLM contract# HHSN P,
Medical Image Analysis Introduction Figures come from the textbook: Medical Image Analysis, by Atam P. Dhawan, IEEE Press, 2003.
Medical Image Analysis Introduction Figures come from the textbook: Medical Image Analysis, Second Edition, by Atam P. Dhawan, IEEE Press, 2011.
Positron Emission Tomography
Supplementary Material Emission Computed Tomography
Introduction to Nuclear Medicine
MEDICAL IMAGING.
Medical Image Analysis Medical Imaging Modalities: X-Ray Imaging Figures come from the textbook: Medical Image Analysis, Second Edition, by Atam P. Dhawan,
A-LEVEL PHYSICS 15/09/ :49 Medical Physics.
Design and simulation of micro-SPECT: A small animal imaging system Freek Beekman and Brendan Vastenhouw Section tomographic reconstruction and instrumentation.
Moscow-Bavarian Joint Advanced Student School March 2006, Moscow, Russia Correction and Preprocessing Methods Veselin Dikov Moscow-Bavarian Joint.
Fundamental Limits of Positron Emission Tomography
Medical Image Analysis Dr. Mohammad Dawood Department of Computer Science University of Münster Germany.
Medical Image Analysis Image Reconstruction Figures come from the textbook: Medical Image Analysis, by Atam P. Dhawan, IEEE Press, 2003.
Interaction ionizing radiation with biological tissue. Basic dosimetry.
© Jimoid.com 2005 Imaging Basics A medical image is a 2D or 3D distribution of signals which represent properties of an object. The purpose of medical.
Single Photon Emission Computed Tomography
Professor Brian F Hutton Institute of Nuclear Medicine University College London Emission Tomography Principles and Reconstruction.
Neuroimaging Methods: Visualising the brain & its injuries Structural (brain structure) –X-rays –CT (Computer Tomography) –MRI (Magnetic Resonance Imaging)
Ultrasound, Positron Emission Tomography, and Single Photon Emission Tomography Allen T. Newton, Ph.D. PAVE 2014.
Medical Image Analysis Interaction of Electromagnetic Radiation with Matter in Medical Imaging Figures come from the textbook: Medical Image Analysis,
Introduction to Modern Medical Imaging
Nuclear Medicine: Tomographic Imaging – SPECT, SPECT-CT and PET-CT Katrina Cockburn Nuclear Medicine Physicist.
Nuclear Medicine Physics
Nuclear Medicine Principles & Technology_I
Medical applications of particle physics General characteristics of detectors (5 th Chapter) ASLI YILDIRIM.
Impact of Axial Compression for the mMR Simultaneous PET-MR Scanner Martin A Belzunce, Jim O’Doherty and Andrew J Reader King's College London, Division.
Alternative Neuroimaging Techniques PET TMS SPECT EEG
1 Nuclear Medicine SPECT and PET. 2 a good book! SR Cherry, JA Sorenson, ME Phelps Physics in Nuclear Medicine Saunders, 2012.
Interaction of x-ray photons (and gamma ray photons) with matter.
Nuclear Medicine Physics and Equipment 243 RAD 1 Dr. Abdo Mansour Assistant Professor of radiology
Nuclear Medicine Instrumentation 242 NMT 1 Dr. Abdo Mansour Assistant Professor of radiology
Chapter-4 Single-Photon emission computed tomography (SPECT)
Medical Physics.
Introduction to Medical Imaging SPECT, Introduction to Medical Imaging SPECT, PET and Lesion Detection Guy Gilboa Course
X-Ray Learning Objectives State general assumptions class makes Understand energy profile of X-ray source Duality Ideal projection X-ray imaging equation.
Medical Imaging. X-ray Radiography 2-D projection image created from difference in x-ray absorption rates between tissues 2-D projection image created.
PET Imaging Positron Emission Tomography
Introduction to Medical Imaging Week 2: X-ray and CT
Simulations in Medical Physics Y. TOUFIQUE*, R.CHERKAOUI EL MOURSLI*, M.KACI**, G.AMOROS**, *Université Mohammed V –Agdal, Faculté des Sciences de Rabat,
Chapter-5 Positron emission tomography (PET)
P.E.T. Positron Emission Tomography
Medical Imaging System BME 330 Lecture 0: Opening
Image quality and Performance Characteristics
Image quality and Performance Characteristics
Summary of the Compton-PET project
Function and Structure in
Application of Nuclear Physics
Physics of Nuclear Medicine, SPECT and PET
Tianfang Li Quantitative Reconstruction for Brain SPECT with Fan-Beam Collimators Nov. 24th, 2003 SPECT system: * Non-uniform attenuation Detector.
Function and Structure in
Assist. Prof. Dr. Ilker Ozsahin Oct
Presentation transcript:

BMI I FS05 – Class 4 “Nuclear Imaging: Math” Slide 1 Biomedical Imaging I Class 5 – Radionuclide Imaging (PET, SPECT), Part 3: Attenuation and Scatter Corrections 10/12/05

BMI I FS05 – Class 4 “Nuclear Imaging: Math” Slide 2 Recommended Reading K. Miles, P. Dawson, and M. Blomley (Eds.), Functional Computed Tomography (Isis Medical Media, Oxford, 1997). R. J. English, SPECT: Single Photon Emission Computed Tomography: A Primer (Society of Nuclear Medicine, Reston, VA, 1995). M. Reivich and A. Alavi (Eds.), Positron Emission Tomography (A. R. Liss, NY, 1985).

BMI I FS05 – Class 4 “Nuclear Imaging: Math” Slide 3 Characteristics of SPECT & PET images Low spatial resolution Dose limitations → long acquisition time Imperfect tissue selectivity Scatter effects Low SNR Dose limitations → poor counting statistics Attenuation High CNR Essentially no signal except from the administered radionuclide Post-processing operations improve SNR at the expense of spatial resolution Spatial low pass (“long pass”) filtering

BMI I FS05 – Class 4 “Nuclear Imaging: Math” Slide 4 Interplay of spatial resolution and CNR Ideal case: – No “bleeding” of signal from one location into the adjacent ones – Difference between signal arising from adjacent positions determines the contrast, and hence the CNR Reality: – Lateral spreading of image information results in lowering of high signal levels and raising of low ones – The apparent signal difference between adjacent sites is lower than in the ideal case, and so the CNR is lower

BMI I FS05 – Class 4 “Nuclear Imaging: Math” Slide 5 Attenuation Correction

BMI I FS05 – Class 4 “Nuclear Imaging: Math” Slide 6 Projection Operator f(x,y)f(x,y) x θ x s y -a a

BMI I FS05 – Class 4 “Nuclear Imaging: Math” Slide 7 Projection Operator — CT vs. ECT x–ray CT: ECT: spatial distribution of attenuation coefficient spatial distribution of radioactivity

BMI I FS05 – Class 4 “Nuclear Imaging: Math” Slide 8 X-Ray Energy & Contrast 20 keV 200 keV 2000 keV (= 2MeV) 99m Tc γ -ray photons e - -e + annihilation γ -ray photons

BMI I FS05 – Class 4 “Nuclear Imaging: Math” Slide 9 Other approaches to attenuation correction Use co-registered anatomical image (e.g., MRI, x-ray CT) to generate an estimate of the tissue µ at each location, and insert that into Eq. (2) (Slide 7) Use known-strength γ -emitting standards (e.g., 153 Gd (Webb, §2.9.2, p. 79) or 68 Ge (§ , p. 95)) in conjunction with image data collection, to estimate µ at each tissue location Iterative image reconstruction algorithms In “odd-numbered” iterations, treat µ(u,v) as known and fixed, and solve for ρ(x,y) In “even-numbered” iterations, treat ρ(x,y) as known and fixed, and solve for µ(u,v) Even more elaborate mathematical techniques, e.g., E. Y. Sidky and X. Pan, “Image reconstruction with a half–detector in single–photon emission computed tomography with nonuniform attenuation,” Optical Engineering 42(9), (2003). I. Laurette et al., “A three–dimensional ray–driven attenuation, scatter and geometric response correction technique for SPECT in inhomogeneous media,” Physics in Medicine and Biology 45, (2000). T. Kauppinen et al., “Improvement of brain perfusion SPET using iterative reconstruction with scatter and non–uniform attenuation correction,” European J. Nuclear Medicine 27(9), (2000).

BMI I FS05 – Class 4 “Nuclear Imaging: Math” Slide 10 Scatter Correction

BMI I FS05 – Class 4 “Nuclear Imaging: Math” Slide 11 Origins of scatter artifacts Accidental coincidences (PET) Compton scatter events (SPECT and PET) Can redirect photons within measurement plane, or can redirect photons arising from outside measurement plane into it (assuming ring-shaped detector array) Spatially and directionally distributed source Higher photon energy than in x-ray CT means that detector collimation is less effective More serious problem for area detectors (for whole-body imaging, for example) than for ring-shaped detector arrays

BMI I FS05 – Class 4 “Nuclear Imaging: Math” Slide 12 Inherent Dimensionality

BMI I FS05 – Class 4 “Nuclear Imaging: Math” Slide 13 Scatter correction techniques Compton scattering (SPECT & PET) Energy “sub-window” method (Webb, §2.9.2, p. 78) Extrapolation of scattered “source” strength, from image regions outside the patient’s body, to image regions within it (§ , p. 97) Accidental coincidences (PET) True but impractical: if the radius r of the detector ring is varied, the rate of true coincidences is proportional to 1/r, while the accidental coincidence rate is proportional to 1/r 2 Accidental coincidence rate for a pair of detector is proportional to the product of the overall count rates for each By increasing the delay between the timing pulses sent to each detector in a pair, can selectively detect only accidental coincidences